• Title/Summary/Keyword: Method detection limits

Search Result 596, Processing Time 0.027 seconds

Simultaneous Determination of Paeoniflorin and Glycyrrhizin in Sayuk-san by HPLC/DAD

  • Lee, Mi-Kyeong;Lee, Ki-Yong;Kim, Seung-Hyun;Jeon, Min-Ji;Cho, Jung-Hee;Oh, Mi-Hyun;Baek, Ju-Hyun;Kim, Hyo-Jin;Sung, Sang-Hyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.23-27
    • /
    • 2009
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of marker constituents, paeoniflorin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Sayuk-san (SYS). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, $4.6mm\;I.D.{\times}150mm$) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 mL/min. The diode-array UV/vis detector (DAD) was used for the detection and the wavelength for quantification was set at 230 nm. The presence of paeoniflorin and glycyrrhizin in this decoction was ascertained by retention time, spiking with each authentic standard and UV spectrum. All two compounds showed good linearity ($r^2$>0.996) in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 7.3% and the limits of detection (LOD) were less than 55.7 ng. The mean recovery of each compound was $102.3{\sim}111.1%$ with R.S.D. values less than 4.6%. This method was successfully applied to the determination of contents of paeoniflorin and glycyrrhizin in three commercial products of SYS. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial SYS products.

Chemical Derivatization of Catecholamines for Gas Chromatography-Mass Spectrometry

  • Park, Sun-Young;Kang, Bo-Xin;Li, Quing;Kim, Hoon-Sik;Lee, Jun-Gae;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.7
    • /
    • pp.1497-1504
    • /
    • 2009
  • GC/MS analysis of catecholamines (CAs) in biological sample may produce poor reproducible quantitaion when chemical derivatization is used as the technique to form a volatile derivative. Significant quantities of the side products can be formed from CAs with primary amine during the derivatization reaction under un-optimized conditions. We have tested various chemical derivatization techniques in an attempt to find an optimum derivatization method that will reduce side product formation, enable to separate several catecholamine derivatives in GC chromatogram, and obtain significant improvement of detection sensitivity in GC/MS analysis. Whereas several derivatization techniques such as trimethylsilylation (TMS), trifluoroacylation (TFA), and two step derivatization methods were active, selective derivatization to form O-TMS, N-heptafluorobutylacyl (HFBA) derivative using N-methyl-N-(trimethylsilyl)-trifluoroacetamide (MSTFA) and N-methyl-bis(heptafluorobutyramide) (MBHFBA) reagents was found to be the most effective method. Moreover, this derivative formed by selective derivatization could provide sufficient sensitivity and peak separation as well as produce higher mass ion as base peak to use selected ion in SIM mode. Calibration curves based on the use of an isotopically labeled internal standard show good linearity over the range assayed, 1 ~ 5000 ng/mL, with correlation coefficients of > 0.996. The detection limits of the method ranged from 0.2 to 5.0 ppb for the different CAs studied. The developed method will be applied to the analysis of various CAs in biological sample, combined with appropriate sample pretreatment.

Loop-Mediated Isothermal Amplification Assay Targeting the femA Gene for Rapid Detection of Staphylococcus aureus from Clinical and Food Samples

  • Zhao, Xihong;Li, Yanmei;Park, Myoungsu;Wang, Jun;Zhang, Youhong;He, Xiaowei;Forghani, Fereidoun;Wang, Li;Yu, Guangchao;Oh, Deog-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.2
    • /
    • pp.246-250
    • /
    • 2013
  • In this study, a loop-mediated isothermal amplification (LAMP) method to rapidly detect Staphylococcus aureus strains was developed and evaluated by extensively applying a large number of S. aureus isolates from clinical and food samples. Six primers were specially designed for recognizing eight distinct sequences on the species-specific femA gene of S. aureus. The detection limits were 100 fg DNA/tube and $10^4$ CFU/ml. The LAMP assay was applied to 432 S. aureus strains isolated from 118 clinical and 314 food samples. Total detection rates for the LAMP and polymerase chain reaction assays were 98.4% (306/311) and 89.4% (278/311), respectively.

Detection and Quantification of Fusarium oxysporum f. sp. niveum Race 1 in Plants and Soil by Real-time PCR

  • Zhong, Xin;Yang, Yang;Zhao, Jing;Gong, Binbin;Li, Jingrui;Wu, Xiaolei;Gao, Hongbo;Lu, Guiyun
    • The Plant Pathology Journal
    • /
    • v.38 no.3
    • /
    • pp.229-238
    • /
    • 2022
  • Fusarium wilt caused by Fusarium oxysporum f. sp. niveum (Fon) is the most serious soil-borne disease in the world and has become the main limiting factor of watermelon production. Reliable and quick detection and quantification of Fon are essential in the early stages of infection for control of watermelon Fusarium wilt. Traditional detection and identification tests are laborious and cannot efficiently quantify Fon isolates. In this work, a real-time polymerase chain reaction (PCR) assay has been described to accurately identify and quantify Fon in watermelon plants and soil. The FONRT-18 specific primer set which was designed based on identified specific sequence amplified a specific 172 bp band from Fon and no amplification from the other formae speciales of Fusarium oxysporum tested. The detection limits with primers were 1.26 pg/µl genomic DNA of Fon, 0.2 pg/ng total plant DNA in inoculated plant, and 50 conidia/g soil. The PCR assay could also evaluate the relationships between the disease index and Fon DNA quantity in watermelon plants and soil. The assay was further used to estimate the Fon content in soil after disinfection with CaCN2. The real-time PCR method is rapid, accurate and reliable for monitoring and quantification analysis of Fon in watermelon plants and soil. It can be applied to the study of disease diagnosis, plant-pathogen interactions, and effective management.

Analytical Method Validation of (-)Epicatechin gallate in Penthorum chinense Pursh Extract using HPLC

  • Kwon, Jin Gwan;Jung, Yeon Woo;Seo, Changon;Hong, Seong Su;Lee, Ji Eun;Shin, Hyun Tak;Jung, Su Young;Choi, Chun Whan;Kim, Jin Kyu
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.04a
    • /
    • pp.100-100
    • /
    • 2019
  • This study attempted to establish a High Performance Liquid Chromatography (HPLC) analysis method for the determination of (-)-epicatechin gallate as a part of the quality control for the development of functional cosmetic materials from Penthorum chinense Pursh extracts. HPLC was performed on a Unison US-C18 column ($4.6{\times}250mm$, $5{\mu}m$) with a gradient elution of 0.05% (v/v) trifluoroacetic acid (TFA) and methyl alcohol at a flow rate of 1.0 mL/min at $30^{\circ}C$. The analyte was detected at 280 nm. The HPLC method was performed in accordance with the International Conference on Harmonization (ICH) guideline (version 4, 2005) of analytical procedures with respect to specificity, precision, accuracy, and linearity. The limits of detection and quantitation were 0.11 and 0.33 mg/mL, respectively. Calibration curves showed good linearity (r2 > 0.9999), and the precision of analysis was satisfied (less than 0.6%). Recoveries of quantified compounds ranged from 99.51 to 101.92%. This result indicates that the established HPLC method is very useful for the determination of marker compound in P. chinense Pursh extracts.

  • PDF

Development and Validation of a Unique HPLC-ELSD Method for Analysis of 1-Deoxynojirimycin Derived from Silkworms (누에에 함유된 1-Deoxynojirimycin의 분석을 위한 HPLC-ELSD 분석법 밸리데이션)

  • Hyejin Cho;Sullim Lee;Myoung-Sook Shin;Joohwan Lee;Sanghyun Lee
    • Korean Journal of Pharmacognosy
    • /
    • v.54 no.1
    • /
    • pp.38-43
    • /
    • 2023
  • A simple and accurate assay was developed for the quantitative analysis of 1-deoxynojirimycin (1-DNJ) derived from the silkworm (Bombyx mori). Normal-phase high-performance liquid chromatography coupled with an evaporative light scattering detector (HPLC-ELSD) and a hydrophilic interaction liquid chromatography column was used. Various parameters were applied to optimize the analysis method. The limits of detection and quantification of 1-DNJ were 2.97 × 10-3 and 9.00 × 10-3 mg/mL, respectively. The calibration curve showed good linearity results. The concentration range and the r2 value were 0.0625-1.0 mg/mL and 0.9997, respectively. The accuracy test demonstrated a significantly high recovery rate (89.95-103.22%). The relative standard deviation was ≤ 1.00%. Thus, a method for the accurate identification and quantitative analysis of 1-DNJ in silkworms was developed. Moreover, in this procedure, the process of derivatization of 1-DNJ, which was required in previous experiments, could be eliminated. This technique may be actively utilized for the development of pharmaceuticals and health functional foods using 1-DNJ.

Determination of Residual Erythromycin Antibiotic in Fishery Products by Liquid Chromatography-electrospray Ionization Mass Spectrometry (LC-MS/MS를 이용한 어류 및 갑각류의 잔류 Erythromycin 항생제 분석)

  • Jo, Mi-Ra;Mok, Jong-Soo;Lee, Doo-Seog;Kim, Min-Jung;Kim, Poong-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.1
    • /
    • pp.15-19
    • /
    • 2009
  • A simple and sensitive method for erythromycin quantification by liquid chromatography electrospray mass spectrometry (LC-MS/MS) in fishery products was developed. Samples were extracted by liquid-liquid extraction using 70% acetonitrile. Lipids were removed by acetonitrile saturated hexane. LC separation was performed on a Shiseido UG C-18 column ($150\;mm{\times}2.0\;mm$ internal diameter.) with a gradient system of 0.2% acetic acid-acetonitrile containing 0.2% acetic acid as a mobile phase at flow rate of 0.2 mL/min. The mass spectrometer was operated in selected reaction monitoring with positive electro-spray interface. Transitions were monitored a m/z $734{\to}577$ and $734{\to}158$, with m/z $734{\to}577$ chosen for quantification. Recovery of erythromycin from fish and shrimp fortified at the 10 ng/mL, 50 ng/mL and 100 ng/mL were 91.6-109.4%, 84.4-111.2% and 98.8-109.6% with high precision, respectively. Limits of quantification and limits of detection of erythromycin in both fish and shrimp were 10.0 ng/mL and 1.0 ng/mL, respectively. This analysis method for erythromycin has been proposed for registration in the Korean Official Methods of Food Analysis and has been utilized for fishery products analysis by the Korea Food and Drug Adminstration and the National Fisheries Products Quality Inspection Service.

Water-Soluble Vitamins Contents in Seafood-Based Dishes (수산물 조리 식품에 함유된 수용성 비타민 함량)

  • Kim, Naeun;Kim, Younghwa
    • The Korean Journal of Food And Nutrition
    • /
    • v.33 no.4
    • /
    • pp.390-398
    • /
    • 2020
  • The purpose of this study was to determine the contents of water-soluble vitamins B1 (thiamine), B2 (riboflavin), B3 (niacin) and B12 (cyanocobalamin) in seafood-based dishes by using the high-performance liquid chromatography with the ultra violet and fluorescence detector. The vitamin B1, B2, B3 and B12 contents were analyzed in 29 seafood-based dishes. The method validation was performed on the method to determine the linearity, accuracy, limits of quantification, limits of detection and precision for vitamin B1, B2, B3 and B12. An excellent linearity range (R2=0.999~1.000) in the calibration curve for the water-soluble vitamins was observed. All analytical methods for the water-soluble vitamins showed the acceptable accuracy (89.4~119.7% recovery) and the precision (0.6~4.8% repeatability and 1.0~4.2% reproducibility). The highest content of vitamin B1 was 2.646 mg/100 g in the kkongchi-jorim, and the highest contents of vitamin B2, B3 and B12 were 0.370 mg/100 g, 10.971 mg/100 g, and 17.193 ㎍/100 g, respectively, in the kkongchi-gui. Our results provide reliable data on the contents of the water-soluble vitamins of seafood-based dishes in Korea.

Simultaneous Determination of Six Bioactive Components in Guibi-tang by HPLC-DAD (HPLC-DAD를 이용한 귀비탕 중 6종 생리활성 물질의 동시분석법 확립)

  • Yang, Hye-Jin;Weon, Jin-Bae;Ma, Jin-Yeul;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.41 no.4
    • /
    • pp.313-318
    • /
    • 2010
  • Guibi-tang, a traditional herbal medicine, is used for anti-oxidant, anti-osteoporosis, hemostasis and gastroprotection. To develop an analysis method of simultaneous determination of six compounds, swertisin, decursinol, glycyrrhizin, 6-gingerol, costunolide and decursin in Guibi-tang, a high performance liquid chromatography was used with diode array detector. Six bioactive components were separated on a SHISEIDO $C_{18}$ column ($5\;{\mu}m$, 4.6 mm I.D.${\times}$250 mm) with column temperature $30^{\circ}C$. The gradient elution was composed of water with 0.1% trifluoroacetic acid (TFA) and acetonitrile. UV wavelength was set at 230 nm, 254 nm and 330 nm, respectively. Calibration curve showed good linear regression ($R^2$ > 0.9999). The limits of detection (LOD) and the limits of quantification (LOQ) ranged in 0.03 - 0.23 ${\mu}g/ml$ and 0.08 - $0.70\;{\mu}g/ml$, respectively. The RSD values of intra- and inter-day test were in the range of 0.03 ~ 0.96% and 0.01 ~ 1.46%, respectively. The evaluated results of accuracy test were varied from 92.28% ~ 105.14% with RSD < 1.60%. In conclusion, this developed simultaneous determination method was accuracy and sensitive to the quality evaluation of Guibi-tang.

Analysis of the Marker Compounds in Sagunja-tang by LC-ESI-MS (LC-ESI-MS에 의한 사군자탕의 지표성분 분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.50 no.1
    • /
    • pp.65-71
    • /
    • 2019
  • One of the oriental medicine prescriptions, Sagunja-tang consists of four herbal medicines (Ginseng Radix, Poria Sclerotium, Atractylodis Rhizoma Alba, and Glycyrrhiziae Radix et Rhizoma) and has been used as a medicine to enhance tonify the function of spleen and stomach in Korea. In this study, we conducted simultaneous analysis of the 9 marker components, liquiritin apioside, liquiritin, ginsenoside Rg1, liquiritigenin, ginsenoside Rb1, glycyrrhizin, atractylenolide III, atractylenolide II, and atractylenolide I in Sagunja-tang using a liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS). Marker compounds were separated on a Waters Acquity UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, 1.7 mm) and the column was maintained at $45^{\circ}C$. The mobile phase consists of 0.1% (v/v) aqueous formic acid and acetonitrile with gradient condition. The LC-MS analysis was performed using a Waters ACQUITY TQD LC-MS/MS system with multiple reaction monitoring (MRM) method in the positive and negative modes. The calibration curves of the nine marker components showed good linearity with coefficient of determination ${\geq}0.9984$ within tested range. The limits of detection and limits of quantification values were 0.27-2.42 ng/mL and 0.81-7.27 ng/mL, respectively. The concentrations of tested 9 analytes in the lyophilized Sagunja-tang sample using the established LC-ESI-MS/MS MRM method were detected up to 16.593 mg/g. These results can be useful as a basic data for the quality control of an oriental medicine prescriptions.