• Title/Summary/Keyword: Method detection limits

Search Result 589, Processing Time 0.026 seconds

A Study on Intrusion Alert Redustion Method for IDS Management (침입탐지 시스템 관리를 위한 침입경보 축약기법 적용에 관한 연구)

  • Kim, Seok-Hun;Jeong, Jin-Young;Song, Jung-Gil
    • Convergence Security Journal
    • /
    • v.5 no.4
    • /
    • pp.1-6
    • /
    • 2005
  • Today the malicious approach and information threat against a network system increase and, the demage about this spread to persnal user from company. The product which provides only unit security function like an infiltration detection system and an infiltration interception system reached the limits about the composition infiltration which is being turn out dispersion anger and intelligence anger Necessity of integrated security civil official is raising its head using various security product about infiltration detection, confrontation and reverse tracking of hacker. Because of the quantity to be many analysis of the event which is transmitted from the various security product and infiltration alarm, analysis is difficult. So server is becoming the charge of their side. Consequently the dissertation will research the method to axis infiltration alarm data to solve like this problem.

  • PDF

Simultaneous Determination of Tar Color Additives in Cold Syrups by Ion Pair-high Performance Liquid Chromatography (이온쌍-고성능 액체크로마토그래피에 의한 감기약 시럽에서 타르색소 첨가물의 동시분석)

  • Jin, Jing-Yu;Huang, Hu;Lee, Beom-Gyu;Lee, Won-Jae
    • KSBB Journal
    • /
    • v.25 no.5
    • /
    • pp.459-465
    • /
    • 2010
  • A simple and efficient analytical method for the simultaneous determination of seven tar color additives was developed using ion pair high performance liquid chromatography. The conditions for HPLC analysis were as follows: column, ${\mu}$-Bondapak C18 (10 ${\mu}m$, 300 ${\times}$ 3.9 mm i.d.); gradient mobile phase, 0.025 mol/L ammonium acetate (containing 0.01 mol/L tetrabutylammonium bromide)-acetonitrile-methanol (65:25:10) as a mobile for fraction A and 0.025 mol/L ammonium acetate (containing 0.01 mol/L tetrabutylammonium bromide)-acetonitrilemethanol (40:50:10) as a mobile for fraction B; flow rate, 1.0 mL/ min; detection wavelength, 254/520/620 nm. We could attain to the detection limits as 0.01~0.05 ${\mu}$g/mL (254 nm) and 0.005~0.01 ${\mu}$g/mL (520 nm) for six red tar color additives, and 0.05 ${\mu}$g/mL (254 nm) and 0.002 ${\mu}$g/mL (620 nm) for Fast green FCF. This analytical method was applicable to determine the tar color additives contained in several commercial cold syrups.

Molecularly Imprinted Solid-Phase Extraction for Determination of Enrofloxacin and Ciprofloxacin in Chicken Muscle

  • Yan, Hong-Yuan;Row, Kyung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.1173-1178
    • /
    • 2008
  • A simple and sensitive high-performance liquid chromatographic method was developed for the simultaneous identification of enrofloxacin and its active metabolite ciprofloxacin in chicken muscle. Norflorxacin imprinted polymers synthesized in water-containing systems show high selectivity to enrofloxacin and ciprofloxacin in an aqueous environment. Using these water-compatible imprinted polymers as selective adsorbents in the solid-phase extraction of enrofloxacin and ciprofloxacin from chicken samples, the remaining biological matrix could be quickly washed out from the imprinted column while enrofloxacin and ciprofloxacin were selectively retained and enriched. Analytical separation was performed on a $C_{18}$ column using acetonitrile-water as a mobile phase and fluorescence detection. Good linearity was obtained from 0.8 to 500 ng/g (r > 0.998) with relative standard deviation of less than 3.9%. The mean recoveries of enrofloxacin and ciprofloxacin from chicken muscle were 80.6-94.5% and 77.8-91.8% at three different concentrations. The limits of determinations based on S/N=3 were 0.07 ng/g and 0.09 ng/g, which are below the maximum residue limits established in many countries.

Capillary Electrochromatography with Liquid Crystal Crown Ether Modified Hybrid Silica Monolith for Analysis of Imidacloprid and Carbendazim in Tomatoes

  • Wang, Mingming;Feng, Rui;Shen, Jing;Chen, Hao;Zeng, Zhaorui
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2224-2228
    • /
    • 2012
  • This study describes the ability of capillary electrochromatography (CEC) for the determination of imidacloprid and carbendazim in tomato samples. A novel liquid crystal crown ether modified hybrid silica monolithic column was synthesized, characterized and developed as separation column for the first time. Baseline separation of imidacloprid and carbendazim could be achieved using a mobile phase containing 90% (v/v) 20 mmol/L phosphate buffer (pH 7.0) and 10% (v/v) acetonitrile. The matrix matched calibration curves were linear with correlation coefficient $r^2$ > 0.9998 in the range of 0.20-10.00 mg/L. The limits of detection for imidacloprid and carbendazim were 0.061 and 0.15 mg/kg, respectively, which were below the maximum residue limits established by the European Union as well as Codex Alimentarius. Average recoveries for imidacloprid and carbendazim varied from 101.6-108.0% with relative standard deviations lower than 6.3%. This method was applied to the analysis of tomatoes collected from local markets.

Simultaneous Analysis of Pesticides in Aqueous Sample by HF-LPME (HF-LPME를 이용한 수용액 시료 내 농약의 동시 분석)

  • Nam, Jang-Woo;Lee, Kang-Jin;Myung, Seung-Woon
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.5
    • /
    • pp.583-590
    • /
    • 2012
  • The HF (Hollow fiber) extraction method was optimized to analysis seven species of pesticides in aqueous sample and analyzing samples by GC/MS. Hollow fiber extraction showed good efficiency when it was conducted under these conditions: organic solvent was toluene and agitation speed was 1200 rpm. The 15% concentration of NaCl was optimized when it was experimented between 5% and 25%. The equilibrium time was determined at 15 minutes. The pH 5 showed the best effect on the extraction efficiency. The linearities of calibration curves of seven species were good with correlation of regression ($r^2$) over 0.995 when they were experimented over a concentration range of $5{\mu}g/L$ to $50{\mu}g/L$. The analytical data exhibited the detection of limits (LODs) range of $0.37{\mu}g/L$ to $1.23{\mu}g/L$ and the limit of quantification (LOQs) range of $1.19{\mu}g/L$ to $3.91{\mu}g/L$. The optimized HF-LPME extraction method provides a simple and effective preparation and requires small amount of organic solvents and samples compared to conventional pre-treatment methods.

Rapid detection and quantification of porcine circovirus type 2 (PCV 2) DNA in Real-time PCR (Real-time PCR을 이용한 돼지써코바이러스 감염증 진단법 연구)

  • Kim, Eun-Gyeong;Hwang, Bo-Won;Lee, Jong-Min;Son, Byeong-Guk;Park, Ho-Jung;Kim, Tho-Kyoung
    • Korean Journal of Veterinary Service
    • /
    • v.32 no.4
    • /
    • pp.299-306
    • /
    • 2009
  • Assay for the detection and quantification of porcine circovirus type 2 (PCV 2) with the real-time PCR were developed. TaqMan probe real-time using a set of primer/probe was developed for detection of PCV 2. In this study we applied real-time PCR assay to 320 samples, collected from pig farms. In 151 of 320 samples, PCV 2 DNA was detected by conventional PCR assay. All samples positive for PCV 2 DNA in conventional PCR assay were also positive in Real-time PCR assay, but 69 of 169 samples that tested negative for PCV 2 DNA in conventional assay were tested positive in TaqMan probe real-time PCR assay. The test of TaqMan probe real-time PCR resulted in detection and quantification limits of 101 copies per sample. TaqMan probe real-time PCR assay increased the number of samples in which PCV 2 was detected by 21%. TaqMan probe real-time PCR assay is very efficient method in contrast to the conventinal PCR, becoming increasingly important method for gene analysis.

Analytical Method of Polybrominated Biphenyl Ethers(PBDEs) in Environmental Samples (환경시료 중 폴리브롬화비페닐에테르(Polybrominated Biphenyl Ethers) 분석법)

  • Kim, T.S.;Hwang, S.Y.;Shin, S.K.
    • Analytical Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.346-359
    • /
    • 2002
  • The brominated flame retardants (BFRs) are one of the unregulated pollutants in Korea, which is recently highlighted the new pollutants of environmental contamination. In this study, the previous research papers related the BFRs were surveyed, and the analytical methods of BFRs were established. The results are followed; The 40 kinds of PBDEs standards were used to establish the analytical methods to perform the experiments of recoveries and detection limits in water and soil. The detection limits of PBDEs using GC/MS represented 5.0~10.0 pg/L for water and 0.5~2.0 ng/g for soil samples. The average recoveries of water samples were 89~98% with ethylacetate, n-hexane and dichloromethane, and 89~103% in combined solvent with n-hexane and acetone. In soxhlet extraction, the higher recoveries obtained the acetone:n-hexane(1:1) comparing with acetone:dichloromethane(1:1).

Method for the Analysis of Polybrominated Biphenyls(PBBs) in Environmental Samples (환경시료 중 폴리브롬화비페닐(Polybrominated Biphenyls) 분석법)

  • Shin, S.K.;Kim, T.S.;Hwang, S.Y.;Lee, W.S.;Chung, Y.H.;Na, J.G.
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.300-316
    • /
    • 2002
  • The extraction methods of PBBs from environmental samples by soxhlet extraction for solid phase and liquid-liquid extraction for liquid phase were compared. After extraction, silicagel and florisil as column clean up methods were used for the comparison of cleanup efficiency with different solvent system. Also, the analytical instruments were used GC/MSD. The 22 kinds of PBBs standards were used to establish the analytical methods to perform the experiments of recoveries and detection limits in water and soil. The detection limits of PBBs represented 5~10 ng/L for water and 0.5~3.5 ng/g for soil samples, respectively. The recoveries of water samples represented 96~107% in n-hexane, dichloromethane and toluene for water, and 60~80% in combined solvent with n-hexane and acetone. The recoveries of soil sample were surveyed 67~97% in soxhlet extraction and 64~76% in ultrasonic extraction with selected solvents.

Establishment of withdrawal time and analysis of tiamulin residue in tissues of orally dosed broiler chickens (육계의 조직 중 티아물린의 잔류 분석 및 휴약기간 설정 연구)

  • Woo H. Kim;Jun Young Kim;Kwang Il Park;Yeung Bae Jin;Suk Kim;Hu-Jang Lee
    • Korean Journal of Veterinary Research
    • /
    • v.63 no.3
    • /
    • pp.23.1-23.9
    • /
    • 2023
  • This study was conducted to investigate tiamulin (TML) residues in the edible tissues of orally dosed broiler chickens and to re-establish the withdrawal time (WT). Thirty-six healthy Ross broiler chickens were administered 0.5 (TML-1) and 2.5 kg (TML-2) per ton feed, respectively, of the drug containing TML 78 g/kg for 10 days. Twenty-four tissue samples were collected from 6 chickens in each of the TML-1 and TML-2 groups on 0, 1, 3, and 5 days after drug administration, respectively. The residual concentrations of TML were measured using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The correlation coefficient of the calibration curves was 0.9978 to 0.9998, and the limits of detection and the limits of quantification (LOQ) were in the range of 0.03 to 0.06, and 0.1 to 0.2 ㎍/kg, respectively. Recoveries ranged between 89.0% to 116.7%, and the coefficients of variation were less than 13.9%. After the drug administration, TML in the TML-1 and TML-2 groups was detected above the LOQ in 1 and 6 samples of liver, respectively, at day 0, and in 1 liver sample from both groups on day one. At 3 days after administration, TML was detected below the LOQ in all samples of TML-1 and TML-2. The calculated WT of TML in both TML-1 and TML-2 using the WT calculation program WT 1.4 was 0 days. In conclusion, the developed analytical method is suitable for detection, and the calculated WT of TML in poultry edible tissues is shorter than the current recommended WT of 7 days for TML in broiler chickens.

Determination of Methoxyfenozide Residues in Water and Soil by Liquid Chromatography: Evaluation of its Environmental Fate Under Laboratory Conditions

  • Choi, Jeong-Heui;Mamun, M.I.R.;Shin, Eun-Ho;Kim, Hee-Kwon;El-Aty, A.M. Abd;Shim, Jae-Han
    • Toxicological Research
    • /
    • v.24 no.3
    • /
    • pp.207-212
    • /
    • 2008
  • Pesticide residues play several key roles as environmental and food pollutants and it is crucial to develop a method for the rapid determination of pesticide residues in environments. In this study, a simple, effective, and sensitive method has been developed for the quantitative analysis of methoxyfenozide in water and soil when kept under laboratory conditions. The content of methoxyfenozide in water and soil was analyzed by first purifying the compound through liquid-liquid extraction and partitioning followed by florisil gel filtration. Upon the completion of the purification step the residual levels were monitored through high performance liquid chromatography(HPLC) using a UV absorbance detector. The average recoveries of methoxyfenozide from three replicates spiked at two different concentrations and were ranged from 83.5% to 110.3% and from 98.1% to 102.8% in water and soil, respectively. The limits of detection(LODs) and limits of quantitation(LOQs) were 0.004 vs. 0.012 ppm and 0.008 vs. 0.024 ppm, respectively. The method was successfully applied to evaluate the behavioral fate of a 21% wettable powder(WP) methoxyfenozide throughout the course of 14 days. A first-order model was found to accurately fit the dissipation of methoxyfenozide in water with and a $DT_{50}$ value of 3.03 days was calculated from the fit. This result indicates that methoxyfenozide dissipates rapidly and does not accumulate in water.