• Title/Summary/Keyword: Method R

Search Result 15,123, Processing Time 0.051 seconds

Performance Evaluation of Barlat's and BBC Yield Criteria based on Directionalities of R-values and Yield Stresses

  • Lou, Y.;Bae, G.;Lee, C.;Park, C.;Buh, H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.277-280
    • /
    • 2009
  • This paper deals with the performance evaluation of Barlat's and BBC yield criteria by the directional variation prediction of the yield stresses and the R-values. for the evaluation of yield criteria, three kinds of Aluminum alloys and two kinds of steels were selected and their material properties are from Stoughton and Yoon's work. The experimental data required for the parameter evaluation included the uniaxial yield stresses and R-values (width-to-thickness strain ratio in uniaxial tension) measured in rolling direction, diaganol direction and the transverse direction, the equibiaxial yield stress and the R-value of equibiaxial tension. The optimization method, the Downhill Simplex method, was selected for the coefficient identification of Barlat91, Barlat97 and Barlat2000 yield criteria. Yield surface shapes, yield stress and R-value directionalities of Barlat's and BBC yield criteria were investigated and compared with the experimental data. Barlat2000 and BBC yield criteria were extremely qualified for the shape of the yield surface and the directionality of the yield stresses and the R-values.

  • PDF

Use of laser fluorescence device 'DIAGNODent$^{(R)}$' for detecting caries (레이저 우식진단기기 'DIAGNODent$^{(R)}$'의 활용)

  • Lee, Byoung-Jin
    • The Journal of the Korean dental association
    • /
    • v.49 no.8
    • /
    • pp.461-471
    • /
    • 2011
  • The detection of carious lesions is a key point to apply appropriate preventive measures or operative treatment of dental caries. A laser fluorescence device DIAGNOdent$^{(R)}$ (KaVo, Biberach, Germany) has also been shown to be of additional clinical value in the detection of initial caries. This report focus on the DIAGNOdent$^{(R)}$ for caries detection. DIAGNOdent$^{(R)}$ irradiate visible red light at a wavelength of 655 nm to elicit near-infrared fluorescence from caries lesion. This device is known as a reproducible method for caries detection, with good sensitivity and specificity especially for caries detection on occlusal and accessible smooth surfaces. DIAGNOdent$^{(R)}$ tended to be more sensitive method of detecting occlusal dentinal caries, however, showed more false-positive diagnoses than the visual inspection. So Clinician should not use the device as a clinician's primary diagnostic method and it is recommended that the device should be used in the decision-making process in relation to the diagnosis of caries as a second opinion in cases of doubt after visual inspection. The trend of modern dentistry would be a preventive approach rather than invasive treatment of the disease. This is possible only with early detection and respective preventive measures, DIAGNOdent$^{(R)}$ can help the changes.

On Relevant Ramberg-Osgood Fit to Engineering Non-Linear Fracture Mechanics Analysis (정확한 비선형 파괴역학 해석을 위한 새로운 Ramberg-Osgood 상수 결정법)

  • Kim, Yun-Jae;Huh, Nam-Su;Kim, Young-Jin;Choi, Young-Hwan;Yang, Jun-Seok
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.170-177
    • /
    • 2003
  • This paper proposes a robust method for the Ramberg-Osgood (R-O) fit to accurately estimate elastic-plastic J from engineering fracture mechanics analysis based on deformation plasticity. The proposal is based on engineering stress-strain data to determine the R-O parameters, instead of true stress-strain data. Moreover, for practical applications, the method is given not only for the case when full stress-strain data are available but also for the case when only yield and tensile strengths are available. Reliability of the proposed method for the R-O fit is validated against detailed 3-D Finite Element (FE) analyses for circumferential through-wall cracked pipes under global bending using five different materials, three stainless steels and two ferritic steels. Taking the FE J results based on incremental plasticity using actual stress-strain data as reference, the FE J results based on deformation plasticity using various R-O fits are compared with reference J values. Comparisons show that the proposed R-O fit provides more accurate J values for all cases, compared to existing methods for the R-O fit. Advantages of the proposed R-O fit in practical applications are discussed, together with its accuracy.

  • PDF

A Study on the Color Stability of Temporary Resins according to Polymerizing Methods and Staining (온성 방법에 따른 수종의 임시 수복용 레진의 착색시의 색 안정성에 관한 연구)

  • Park, Sung-Ho;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • Dental temporary resin should have adequate strength and similar esthetics as natural teeth. Recently esthetics has become a high priority in clinical dentistry. Thus the evaluation of color stability of dental temporary resin has become an important part in dental research. The purpose of this study was to evaluate the difference in color stability of 3 resins($Snap^{(R)}$, Temporary bridge $resin^{(R)}$, Trim $II^{(R)}$) according to polymerizing methods and stainning. The resins were divided into groups by 2 types of polymerizing methods ( air or pressure and heat curing) The resins were dyed with coffee, chlorhexidine and artificial saliva and then the color stability was evaluated with a spectrophotometer(CM-503i, Minolta, Japan). The results were as follows ; 1. In the color stability according to polymerizing method, pressure and heat polymerizing method was higher than air polymerizing method. 2. The color stability according to staining fluid decreased in the order of I, II, III group, there was significant difference among the groups of staining fluid. 3. The color stability according to resins decreased in the order of $Snap^{(R)}$, Trim $II^{(R)}$, Temporary Bridge $resin^{(R)}$, The $Snap^{(R)}$ resin was highest color stability, there was significant difference among the 3 resins.

  • PDF

On Relevant Ramberg-Osgood Fit to Engineering Non-Linear Fracture Mechanics Analysis (정확한 비선형 파괴역학 해석을 위한 Ramberg-Osgood 상수 결정법)

  • Huh, Nam-Su;Kim, Yun-Jae;Choi, Young-Hwan;Yang, Jun-Seok;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1571-1578
    • /
    • 2003
  • This paper proposes a robust method for the Ramberg-Osgood(R-O)fit to accurately estimate elastic-plastic J from engineering fracture mechanics analysis based on deformation plasticity. The proposal is based on engineering stress-strain data to determine the R-O parameters, instead of true stress-strain data. Moreover, for practical applications, the method is given not only for the case when full stress-strain data are available but also for the case when only yield and tensile strengths are available. Reliability of the proposed method for the R-O fit is validated against detailed 3-D Finite Element (FE) analyses for circumferential through-wall cracked pipes under global bending using five different materials, three stainless steels and two ferritic steels. Taking the FE J results based on incremental plasticity using actual stress-strain data as reference, the FE J results based on deformation plasticity using various R-O fits are compared with reference J values. Comparisons show that the proposed R-O fit provides more accurate J values for all cases, compared to existing methods for the R-O fit. Advantages of the proposed R-O fit in practical applications are discussed, together with its accuracy.

Correlation study of in vitro and in vivo test for SPF (Sun Protection Factor)

  • Jihyun, Jihyun-Bae;Sungyeon Ahn;Lee, Haekwang;Seongjoon Moon;Ihseop Chang
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.407-416
    • /
    • 2003
  • In this study, we evaluate the correlation between in vitro and in vivo determination of SPF of sunscreen products containing various ingredients depending on emulsification system. For in vitro approach, we determined SPF by the method of Diffey and Robson using an TransporeTM tape(3M Health care, USA) and SPF 290-analyzer(Optometrics Co. USA). SPF values and standard deviations are calculated and displayed after completion of the run. In vivo SPF values are determined according to KFDA (the Korea Food and Drug Administration) method in panels of Fitzpatrick's skin type II or III. We investigated the difference in SPF data of sunscreen ingredient according to emulsification system. The in vivo SPF data is high in water-in oil(W/O) emulsion than in oil-in water(O/W) emulsion samples. The difference may be due to the particular behavior in each vehicles and its presence on skin surface may produce a different sunscreen film. We obtained the corrlation coefficient between in vitro and in vivo SPF data for O/W (R-squre=0.72 )and W/O emulsion(R-squre=0.77). From these results, we suggest the improvement of methodology using Transpore$^{TM}$ tape as substrate to increase the predictability of in vitro method.d.

  • PDF

A Study on the Method to Establish an User Environment of a Requirements Management Database Using Web Access of Cradle(R) (Cradle(R)의 Web Access를 이용한 철도시스템 사양관리환경 구축방안 연구)

  • Chung, Kyung-Ryul;Park, Chul-Ho;Song, Seon-Ho;Hur, Jee-Youl
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.132-140
    • /
    • 2009
  • The Cradle(R) is specialized systems engineering tool that developed by 3SL(Structure Software System Limited) that has headquarters in U.K. and U.S.A.. It is recognized as the fastest growing Computer-Aided Systems Engineering Tool(CASE Tool). We built up requirements management database by using Cradle(R) on urban maglev program in Korea. So Cradle(R) provide a network function, is available accesses of clients in external organization that is associated on urban maglev program by the internet. However the network function of Cradle(R) require an opening of some a specific network ports and may causes a decreasing network speed. In this paper, we propose the method to establish an user environment of a requirements management database that overcome constraints on network condition.

  • PDF

A Comparison of Multivariate R-Techniques in SAS, SPSS, Minitab and S-plus (SAS, SPSS, MINITAB, 5-PLUS에서 다변량 R-기법의 비교)

  • 최용석;문희정
    • The Korean Journal of Applied Statistics
    • /
    • v.17 no.1
    • /
    • pp.153-164
    • /
    • 2004
  • In this study, we compare multivariate R-techniques in the up-to-date versions of SAS, SPSS, Minitab and S-plus. The direct input method by typing in command is considered for SAS, while the menu-driven method is considered for SPSS, Minitab and S-plus. Comparison was made in terms of input data format, input option, charts and outputs.

Enantiomeric purity test of R-(+)-alpha lipoic acid by HPLC using immobilized amylose-based chiral stationary phase

  • Le, Thi-Anh-Tuyet;Pham, Thuy-Vy;Mai, Xuan-Lan;Song, Chailin;Woo, Sungjun;Jeong, Cheolhee;Choi, Sungyoun;Phan, Thanh Dung;Kim, Kyeong Ho
    • Analytical Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • Alpha lipoic acid, an antioxidant, is widely used for treatment of various diseases. It is a racemic mixture, with R-(+)-α lipoic acid exhibiting greater potency, bioavailability, and effectiveness than those of the S-form. Thus, selective R-(+)-α lipoic acid has been recently used in various applications, necessitating the development of a method to test the enantiomeric impurity in R-(+)-α lipoic acid. We developed a simple and fast high-performance liquid chromatography method using a new immobilized amylose-based chiral column (Chiralpak IA-3). Design of experiment was applied to accurately predict the effects and interactions among various factors affecting the analytical parameters and to optimize the chromatographic conditions. This optimized method could completely separate the two enantiomer peaks with a resolution > 1.8 within a short running time (9 min). Then, the optimized method was validated according to the guidelines of the International Conference on Harmonization and applied for quantification of S-(-)-α lipoic acid in some commercial R-(+)-α lipoic acid tromethamine raw material. Our results suggested that the developed method could be used for routine quality control of R-(+)-α lipoic acid products.

Analysis of Simple Creep Stress Calculation Methods for Creep Life Assessment (크리프 수명 평가를 위한 간략 크리프 응력 산출 방법론 분석)

  • Seo, Jun Min;Lee, Han Sang;Kim, Yun Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.703-709
    • /
    • 2017
  • Creep analysis takes much more time than elastic or elastic-plastic analysis. In this study, we conducted elastic and elastic-plastic analysis and compared the results with creep analysis results. In the elastic analysis, we used primary stress, which can be classified by the $M{\alpha}-tangent$ method and stress intensities recommended in the ASME code. In the elastic-plastic analysis, we calculated the parameters recommended in the R5 code. For the FE models, a bending load, uniaxial load, and biaxial load were applied to the cross shaped welded plate, and a bending load and internal pressure were applied to the elbow pipe. To investigate the element size sensitivity, we conducted FE analysis for various element sizes for the cases where bending load was applied to the cross shaped welded plate. There was no significant difference between the creep stress and the alternative methods; however, in the $M{\alpha}-tangent$ method, the results were affected by the element size.