Dynamic Fracture Testing of Welding part of Nuclear Piping by Using Normalization Method (정규화법을 이용한 원전배관 용접부의 동하중 파괴저항시험)

  • Huh, Yong;Cho, Sung-Keun;Park, Jae-Sil;Seok, Chang-Sung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.262-267
    • /
    • 2004
  • The unloading compliance method is the most commonly used method to evaluate the fracture resistance characteristics of a material. In dynamic loading condition, the direct current potential drop(DCPD) method has been used because the unloading compliance method can not be applied due to the discontinuity of loading. However, even in the dynamic test using DCPD method, there is a problem that the voltage drops sharply on the initiation of crack. For the reason metioned above, the normalization method was suggested on ASTM E 1820 which is revised recently, as a new method to evaluate the dynamic fracture resistance characteristic. The nomalization method can be used to obtain a fracture resistance curve directly from a load-load line displacement. In this study, we obtained two fracture resistance curves from static test of welding part of nuclear piping both by unloading compliance and nomalization method. The two curves were almost same each other, so the adaptability of the nomalization method has been proved. We conducted a dynamic fracture resistance test for the same material. The fracture resistance curve from the dynamic test was obtained by normalization method and compared to that of the static test result.

  • PDF

A bibliographic study of 'the four method of conducting the Qi(氣)' out of Synthetic reinforcing method (종합보사수기법중(綜合補瀉手技法中) 행기(行氣) 사법(四法)의 문헌적(文獻的) 고찰(考察))

  • Park Hui-Su;Kim Gyeong-Sik
    • Journal of Oriental Neuropsychiatry
    • /
    • v.3 no.2
    • /
    • pp.97-106
    • /
    • 1992
  • The literature which was written about manual technique of 'Four method of conducting the Qi(氣)'suggest the following results. 1. Four method of conducting the Qi(氣) is a total method based on the basic manual method, lifing and thrusting, twisting and rotating(捻轉), timing the insertion and withdrawal(呼吸) ect. 2) Cheongryongphami method(靑龍擺尾法) come to understanding channels and conducting and Qi(氣), Paekhoyodu method(白虎搖頭法) using a channels understanding and Qi(氣) introducing, Changkuthamhyeol method(蒼龜探穴法) using a channels understanding, Ceokpongyeongweon method(赤鳳迎源法) using a collaterals understanding. 3) Cheongryongphami(靑龍擺尾) and Changkuthamhyeol method(蒼龜探穴法) were used on disease like insufficiency symptom-complex(盧證), Paekhoyodu(白虎搖頭) and Ceokpongyeongweon method(赤鳳迎源法) were used on excessivess symptom-complex(實證) of pathogenic factors selectively. But all of them often used on C.V.A. 4) The Yang Channel's points, under the elbow and knee point, are often used as points which are used in "Four method of conducting the Qi(氣), and the Yin, Ren(任) Du(督) channels are used less than the former. 5) The manual techniques of 'Four method of conducting the Qi(氣)' are often used in clinically. "Four method of conducting the Qi(氣)"has been studies as above, but there weren't a lot of literature which is about total manual technique of acupuncture. So there is a need study about it.

  • PDF

Improvement Of Address Voltage Margin for Slope Overlapped Scan Method in AC-PDP (AC-PDP 어드레스 전압마진 개선을 위한 Slope Overlapped Scan Method 구현)

  • Kim, Tae-Gyun;Lim, Beong-Ha;Lee, Dong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.460-461
    • /
    • 2008
  • A new AC-PDP driving method was proposed to reduce the address period. The overlapped scan method can reduce the address period. However, this method has a narrow address voltage margin compared with conventional scan method in this paper, Slope overlapped scan method is presented. The proposed new overlapped scan method allows wider address voltage margin than conventional overlapped scan method.

  • PDF

FETM을 이용한 다자유도 회전체 시스템의 진동해석

  • 김승현;김영배
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.818-821
    • /
    • 1995
  • A MDOF vibration analysis of the rotor is performed using combined modeling of transfer matrix method and finite element method(FETM). The method combines the advantages of both matrix. Each rotor is modelled using transfer matrix method and treated one element or several ones. The finite element method is applied in composing a system matrix and finding roots. The method used in this is more efficient than conventional finite element method in saving calculation time and provides good results in complex MDOF rotor model.

  • PDF

The Mixed Finite Element Analysis for Saturated Porous Media using FETI Method

  • Lee, Kyung-Jae;Tak, Moon-Ho;Park, Tae-Hyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.6
    • /
    • pp.693-702
    • /
    • 2010
  • In this paper, FETI(Finite Element Tearing and Interconnecting) method is introduced in order to improve numerical efficiency of Staggered method. The porous media theory, the Staggered method and the FETI method are briefly introduced in this paper. In addition, we account for the MPI(Message Passing Interface) library for parallel analysis, and the proposed combined Staggered method with FETI method. Finally Lagrange multipliers and CG(Conjugate Gradient) algorithm to solve decomposed domain are proposed, and then the proposed method is verified to be numerically efficient by MPI library.

A Comparison of Sampling and Analytical Methods for Airborne Isocyanates (공기중 이소시아네이트류의 측정 및 분석방법에 관한 비교연구)

  • 변혜정;윤충식;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.2
    • /
    • pp.32-42
    • /
    • 1996
  • This study was performed to evaluate accuracy and precision of filter method and impinger method for analyzin airborne isocyanates in mixture (2, 6-TDI, HDI, 2, 4-TDI, MDI). Filter method was performed using the OSHA Method 42 and impinger method using the NIOSH Method 5521. The samples were analyzed by high performance liquid chromatography-ultraviolet detector (HPLC-UVD). After the optimum operating conditions for each method were investigated, samples with various concentration levels were quantified at the conditions. The precision was expressed by the pooled coefficient of variation(C.V.) and the accuracy by overall accuracy. The results are summarized as follows: 1. The optimum condition of filter method was determined at 35/65 ACN/buffer (0.01 M ammonium acetate) in mobile phase. And in case of impinger method, it was at 30/70 ACN/buffer(0.2 M sodium acetate). The effect of concentrations of acetate on the separation of the peaks was not significant, but, the effect of ACN/buffer ratio was significant. 2. The correlation coefficients for the two methods were above 0.9 in all isocyanate compounds. Average recovery efficiencies for 2, 6-TDI, HDI, 2, 4-TDI and MDI in filter method were 92.4%, 102.6%, 87.3% and 101.0%, respectively. Those in impinger method were 106.6%, 106.7%, 99.0% and 103.6%, respectively. As a result, the recovery efficiency of impinger method was higher than those of filter method in analyzing isocyanate compounds. 3. The pooled coefficients of variations of the methods were slightly higher than expected. The overall accuracies of the methods were within $\pm 25%$ for each isocyanate compound. Since these results satisfy NIOSH criteria, the accuracy of the experiment is appropriate. 4. As seen above, impinger method is more efficient than filter method. But, there are many disadvantages in impinger method. Therefore, solid sorbent such as a glass fiber filter must be developed in order to have the high efficiency not less than that of impinger method in the future.

  • PDF

A Study of change of oral health state score from gingivitis patients using toothbrushing method (칫솔질 방법에 따른 치은염 환자의 구강건강상태지수 변화)

  • Jeong, Hyun-Ja;Kim, Hye-Jin;Jeong, Ae-Hwa
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.4
    • /
    • pp.595-602
    • /
    • 2011
  • Objectives : This study purpose were the effect of toothbrushing for decreasing halitosis for gingivitis and periodontitis patients. Methods : The university staffs were examined oral condition and analysised a change of oral health state score after using 3 types of toothbrushing. Results : The results were as followed : OHI-S shows that the decreasing effect takes place in the M. bass method and Tooth pick method, but shows no differences by each method. GI for Self test method shows decreasing effect after 2nd week during education while the M. bass method and Tooth pick method shows after 1st week during education. The M. bass method shows much greater effect of halitosis amongst 3 kind of method. PI for Self test method and Tooth pick method show decreasing effect. Decreasing effect during education shows until 2nd week by 3 kind of method, but it shows no differences after 3rd week. VSC(ppb) for M. bass method and Tooth pick method show decreasing effect. Decreasing effect during education shows after 3rd week by 3 kind of method, but it shows no differences until 2nd week. PHP for Self test method, M. bass method and Tooth pick method show decreasing effect after 2nd week during education. But, there is no differences of decreasing effect by among 3 kind of method. Conclusions : This study reports that it is necessary to carry outt further studies on the improvement of oral health management of adults based on the development of oral health education.

A Study on the River Discharge Measurement Techniques (하천유량 측정기법에 관한 연구)

  • 김성원;지홍기
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.793-801
    • /
    • 1998
  • In this study, the Dilution Method is used to measure river discharge through the hydraulic model test. the dilution method is divided into Constant-Rate-Infection Method and Slug-Injection Method in the river discharge measurement techniques. When the dilution method is applied in the hydraulic model flume, it is analyzed that the estimated error of constant-rate-injection method is less than that of the slug-in-jection method, and the result shows that floodflow analysis is more efficient than lowflow analysis as compared observed discharge with calculated discharge. The result of statistical error analysis shows that the constant-rate-injection method is appropriate technique for the measurement of the river discharge. Therefore, the dilution method among the river discharge measurement techniques can be applied for the river basin which can't be measured with current meter or unsteady-flow regime in the urban-small drainage or hydraulic structure equipment area and can be obtained more exact results than any other discharge measurement techniques.

  • PDF

Hybrid method for design of IPM type BLDC Motor to reduce cogging torque (IPM type BLDC 전동기의 코깅토크 저감을 위한 Hybrid 최적설계)

  • Hwang, Hyu-Yun;Rhee, Sang-Bong;Kwon, Byung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.74-76
    • /
    • 2007
  • A hybrid optimization method is proposed for cogging torque reducing in BLDC motor. The proposed hybrid optimization method comprises a response surface method (RSM) and a gradient search method (GSM). The RSM is effective and global method in optimization problem but having large approximation error. The GSM is accurate and fast search method for optimal solution but having local behavior. To reduce approximation error and computation time a hybrid method (RSM+GSM) is proposed method. To illustrate the effectiveness of the proposed method, a comparison between conventional RSM and the proposed hybrid method is made. A simulation results verify that the hybrid method can achieve favorable design performance.

  • PDF

Novel Frame Interpolation Method for High Image Quality LCDs

  • Itoh, Goh;Mishima, Nao
    • Journal of Information Display
    • /
    • v.5 no.3
    • /
    • pp.1-7
    • /
    • 2004
  • We developed a novel frame interpolation method to interpolate a frame between two successive original frames. Using this method, we are able to apply a double-rate driving method instead of an impulse driving method where a black frame is inserted between two successive original frames. The double-rate driving method enables amelioration of the motion blur of LCDs caused by the characteristics of human vision without reducing the luminosity of the whole screen. The image quality of the double-rate driving method was also found to be better than that of an impulse driving method using our motion picture simulator and an actual panel. Our initial model of our frame interpolation method consists of motion estimation with a maximum matching pixel count estimation function, an area segmentation technique, and motion compensation with variable segmentation threshold. Although salt and pepper noise remained in a portion of an object mainly due to inaccuracy of motion estimation, we verified the validity of our method and the possibility of improvement in hold-type motion blurring.