• Title/Summary/Keyword: Method

Search Result 260,678, Processing Time 0.121 seconds

Studies on the Horizontal Hanging Method in Burley Tobacco Stalk-curing (버어리종 잎담배 대말림시 수평대걸기에 관한 연구)

  • 배성국;김요태;임해건;조천준
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.19 no.1
    • /
    • pp.29-32
    • /
    • 1997
  • This study was carried out to develop a new stalk curing of the horizontal hanging method that would reduce the harvesting and curing labor, and improve its quality of cured leaf than the conventional stalk curing method in burley tobacco. The horizontal hanging stalk-curing method designed from 1988 was compared with the conventional method. The horizontal method shortened the curing Period for 7 days and reduced to 0.3%, while it occurred 9.4% in the vertical method. In the horizontal method, the quality of cured leaf improved 9%, but the contents of chemical components and physical properties were similar to those of vertical method. The labor of stalk-cut and loading in curing facility reduced 28% by the horizontal method. In harvesting and curing process, the horizontal method resulted 12% of labor saving as compared with the vertical method. Key words : horizontal hanging stalk-curing method, vertical method, stalk-curing.

  • PDF

A basic research for the probability based design of wood structures (확률 기반 목구조설계법을 위한 기초 연구)

  • Kim, Gwang-Chul
    • Journal of the Korea Furniture Society
    • /
    • v.20 no.4
    • /
    • pp.339-357
    • /
    • 2009
  • Probability based design(PBD) method is independent of construction materials and uses real material properties unlike allowable stress design(ASD) that depends on small clear specimen property, also give quantitative safety and endurance lifetime of a certain material. Moreover, almost advanced country accepted PBD method instead of ASD method. So it is urgent to convert the current ASD method into the PBD method. However, there are wholly lacking of domestic researches related to current issue, and to solve several points in ASD method and to take advantage of PBD method, the conversion from the ASD method into the PBD method is a worldwide trend. Other domestic construction codes, such as steel or concrete constructions, accept the PBD method as well. Accordingly, to introduce PBD method into wood structural design, general theory, and preliminary data and methods were reviewed. With keeping this in mind, some important contents were reviewed, sorted some points for wood structural design that have distinctions against the other construction materials. Furthermore, the history of PBD method, and statistical data and theories for the PBD method, and preliminary data of resistance and load that are two random variables for the PBD method, and finally the difference between limit state design(LSD) and load and resistance factor design(LRFD) that were two superpowers in the PBD method.

  • PDF

Comparison of In-Plane Measurement of Phase-Shifting with Time-Average Method (위상이동법과 시간평균법의 면내변위 측정 비교)

  • Kim, Kyoung-Suk;Kim, Dong-Iel;Jung, Hyun-Chul;Kang, Ki-Soo;Lee, Chan-Woo;Yang, Seung-Pil;Jarng, Soon-Suck
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.10
    • /
    • pp.53-58
    • /
    • 1999
  • Even I the Electronic Speckle Pattern Interferometry(ESPI) method that measure the strain of object within wavelength of light is less visibility than Holographic Interferometry(HI) method, the merits of application, convenience and time-save have made the method practical in industry. However, the existing ESPI methods that are based on dual-exposure, real-time and time-average method have difficulties for accurate measurement, due to irregular intensity and shake of phase. Recently, in order to solve this problem, phase shifting method have been proposed. In this method, the path of reference light in interference is shifted to make improvement in distinction and precision. But this method includes too many noise, caused by the problem of relationship between object and phase. Therefore, a method to reduce noise muse be introduced. In this paper, least square fitting method is proposed. As results, the phase-map is influenced by precise phase shifting and current of notes and speckle pattern obtained by phase shifting method is improved on the existing method driven from time-average method.

  • PDF

A Comparative Study on the Impermeability-reinforcement Performance of Old Reservoir from Injection and Deep Mixing Method through Laboratory Model Test (실내모형시험을 통한 지반혼합 및 주입공법의 노후저수지 차수 보강성능 비교 연구)

  • Song, Sang-Huwon
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.2
    • /
    • pp.45-52
    • /
    • 2022
  • Of the 17,106 domestic reservoirs(as of December 2020), 14,611 are older than 50 years, and these old reservoirs will gradually increase over time. The injection grouting method is most applied to the reinforcement method of the aging reservoir. However, the injection grouting method is not accurate in uniformity and reinforced area. An laboratory model test was conducted to evaluate the applicability of the deep mixing method, which compensated for these shortcomings, as a reservoir reinforcement method. As a result of calculating the hydraulic conductiveity for each method through the model test results, the injection grouting method was calculated as a hydraulic conductiveity value that was about 7.5 times larger than that of the deep mixing method. As a result of measuring the water level change in the laboratory model test, it was found that the water level change decreased in the injection method and deep mixing method compared to the non-reinforcement method. In addition, deep mixing method showed a water level change of about 15% based on 40 hours compared to the injection method, indicating that the water-reducing effect was superior to that of the injection method.

The Estimation of Horizontal Coefficient of Consolidation Using Velocity Method (Velocity Method를 이용한 수평압밀계수 산정에 관한 연구)

  • 김지용;천홍래;한상재;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.475-480
    • /
    • 2000
  • This study was to present the method for estimating the horizontal coefficient of consolidation by using velocity method which was based on the Barren's equation. Horizontal drainage consolidation tests, including a radial drainage consolidation test, a cylindrical consolidation test, and a large soil box test, were performed to examine its validity. Using the velocity method, horizontal coefficient of consolidation was calculated and compared with lost method, √t method, Magnan & Deroy's method, Bergado's method.

  • PDF

SPECTRAL METHOD FOR RECONSTRUCTING PHYLOGENETIC TREE

  • Paeng, Seong-Hun;Park, Chunjae
    • Communications of the Korean Mathematical Society
    • /
    • v.34 no.3
    • /
    • pp.1005-1014
    • /
    • 2019
  • A new simple method is proposed for reconstructing phylogenetic trees, which we call the spectral method. The most common distance based method is the neighbor-joining method which is based on the minimum evolution principle. The spectral method shows similar performance to the neighbor-joining method for simulated data generated by seq-gen. For real data, the spectral method shows much better performance than the neighbor-joining method. Hence it can be a complementary method for reconstructing phylogenetic trees.

How to Evaluate the Combined Dust Removal Efficiency of Fine Dust in the Dust Collector (집진기 미세먼지의 복합제진효율 평가방법)

  • Kang, Il-Seo;Lee, Young-su;Kim, Dong-Hyun
    • Journal of Digital Convergence
    • /
    • v.20 no.2
    • /
    • pp.339-344
    • /
    • 2022
  • It is about how much fine dust can be efficiently removed with respect to the electric dust collector used in factories and large facilities. The results of evaluating the fine dust removal efficiency are as follows. At 10,000 V, Efficiency method I showed 68.1 %, and Efficiency method II was 58.6 %, which was lower than that of Efficiency method I. At 5,000 V, Efficiency method I showed 57.6%, and Efficiency method II showed 51.6%, which was lower than Efficiency method I. At 2,500 V, Efficiency method I showed 50.3%, and Efficiency method II showed 24.4%, which was lower than Efficiency method I. In case of Efficiency method I, it is the efficiency calculated by using the dust concentration before and after passing through the filter. Efficiency method II calculated Efficiency method II to measure the efficiency a little more accurately in the environment where the air after the filter and the polluted air are mixed. Efficiency method II showed lower efficiency than Efficiency method I. As a result of the electrostatic precipitator test, the dust collecting performance was highest at 10,000 V, followed by 5,000 V and 2,500 V in that order.

Review on the fabrication method and characteristics of colored contact lens (칼라콘택트렌즈의 제조 - 제조방법과 특성에 대해 -)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.127-132
    • /
    • 2005
  • Beginning the use of medical order with color contact lens, recently the color contact lens wearer increases for cosmetic order in the world. The marufacture of color contact lenses was the pigment application method, the pigment inlay method, the sandwich method, the vinding method, and so on. Now in domestic, the main use of manufacture has been the binding method. In the point of the use and manufacture of the color contact lenses, the classification of color contact lenses was the tinted and the cosmetic types. However the generally coloring of color contact lenses was the stain-method and the staining was marufactured by the thin film methods.

  • PDF

Frequency-Phase Method to Measure Material Damping in a Nonlinear Range (비선형 영역에서의 재료감쇠비 측정을 위한 주파수-위상각법)

  • 우규석;조성호
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.533-540
    • /
    • 2001
  • Material damping is an important parameter to evaluate the site response by a dynamic loading. Currently the material damping of the subgrade is mainly determined by a resonant column testing. Typical methods to evaluate material damping include half-power bandwidth method and free-vibration decay method. In the large strain range, the half-power bandwidth method gives an erratic damping factor, because the method is based on the assumption of the linear behavior of a specimen. The free-vibration decay method has also limitations in that the damping factors vary with the range of cycles in calculation, and also in that the specific shear strain can not be designated for the free vibration. In this study, the frequency-phase method, which was developed to evaluate material damping of a beam simply supported, is introduced to evaluate the material damping by the resonant column testing. Also, the comparison among half-power method, free-vibration decay method and the frequency-phase method is provided for a remolded sand.

  • PDF

A Study on the Dietary Intake Survey Method Using a Cameraphone (카메라폰을 이용한 식이섭취 조사방법에 대한 연구)

  • Chang, Un-Jae;Ko, Shin-Ae
    • Korean Journal of Community Nutrition
    • /
    • v.12 no.2
    • /
    • pp.198-205
    • /
    • 2007
  • This study was conducted to investigate the validity of using a cameraphone for a dietary intake survey method. The subjects were 28 female college students. After eating a standard lunch meal which consisted of plain rice, seaweed soup, bulgogi, cucumber salad, roasted anchovy and kimchi, the quantity of dietary intake, calorie intake & nutrients intake were analyzed by weighed method, diet record method and cameraphone method by dietitian with k without cameraphone analysis training. There were no significant differences in the quantity of 6 foods intake between weighted method and cameraphone method by dietitians with camera phone analysis training. However, the quantity of seaweed soup, bulgogi & cucumber salad intake analyzed by diet record method was significantly lower than the weighed method. And the quantity of seaweed soup, bulgogi, cucumber salad, roasted anchovy and kimchi intake analyzed by the cameraphone method by dietitians without cameraphone analysis training was significantly lower than the weighed method. There were no significant differences in the calorie intake and nutrients intake between the weighted method and camera phone method by dietitians with camera-phone analysis training. However, protein, calcium, iron, phosphorous, Vitamin A, Vitamin $B_2$, Vitamin E and cholesterol intake analyzed by diet record method was significantly lower than the weighed method. And fat and Vitamin $B_2$ intake analyzed by the camera phone method by dietitians without cameraphone analysis training was significantly lower than the weighed method. Therefore, this study suggests that the use of the camerephone may be a valid and convenient method fur evaluating a dietary intake survey. However, systematic and standard education is necessary about the size and volume of dishes and angle of photo for more accurate results.