• Title/Summary/Keyword: Metering rate

Search Result 91, Processing Time 0.02 seconds

Effect of the suction plate shape on metering performance of a vacuum metering device for garlic seeds

  • Kim, Deok-Keun;Choi, Yeong-Soo;Yang, Seung-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.4
    • /
    • pp.829-844
    • /
    • 2020
  • A vacuum metering device for garlic seeds was developed, and its metering performance was tested according to the design factors. Three design factors were as follows: suction surface diameter (Edge), suction surface curvature (Type), and guide height (Guide). The suction surface curvature represents the distance between the center of the grooved suction plate and the bottom of suction plate. The metering rate and multiple metering rate were analyzed as the metering performance of the developed device with two varieties of garlic seeds: Namhae (warm region-adapted garlic) and Uiseong (cold region-adapted garlic). The best metering performance for the Namhae seeds were found with the following conditions: An Edge, Guide and Type of 40, 4, and 35 mm, respectively. In the case of the Uiseong seeds, the best conditions were as follows: An Edge, Guide and Type of 35, 4, and 30 mm, respectively. The guide height was found to be the most influential design factor on the metering performance of the metering rate and multiple rate for both Namhae seeds and Uiseong seeds. Additionally, the interaction between the area of the suction surface and the curvature of the suction surface had some effects on the multiple rate for the Uiseong seeds. It was concluded that the guide height should be 4 mm or higher so that more than 90% of the metering rate could be achieved for the tested garlic seeds with the developed metering device.

The Effect of Single-Entry Metering and Platoon Metering on Mainstream under the Same Metering Rate with Pre-timed Metering (정주기식 동일 미터링율 제어에서 차량진입방식에 따른 효과분석)

  • Kim, Sang-Gu;Ryu, Ju-Hyeon
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.3
    • /
    • pp.29-37
    • /
    • 2010
  • Ramp metering control is the most representative strategy of uninterrupted flow control and management system. Ramp metering is to adjust vehicles entering an expressway in such a way that expressway mainline maintains flow stability by regulating ramp vehicles. The effect of two metering strategies, single-entry metering and platoon metering, on mainstream under the same metering rate with pre-timed metering are analyzed by micro-simulation. Platoon metering shows lower performance than single-entry metering under the same metering rate in terms of speed, density, and delay, causes earlier breakdown than single-entry metering. It indicates that the selection of metering type has critical importance as the flow of mainline is high.

Development of An Impact-Type Seed-Metering Device for Rice-Seed Pellets (벼 펠렛 종자용 타격식 파종장치 개발)

  • 최영수;구경본;유수남
    • Journal of Biosystems Engineering
    • /
    • v.26 no.2
    • /
    • pp.115-122
    • /
    • 2001
  • An impact-type seed-metering device was developed for the planting of rice-pellets. In this study, new design of pellet-metering device focused on simplicity and precision seeding for the planting of rice-seed pellets. In addition of seed-metering device, several devices were also developed such as seed-guiding device, seed-supplying tube and furrow opener for precision pellet planting. Field test was conducted to estimate the planting performance of the developed metering device. As a cam rotates, the impact bar of the metering device pushes a rice-seed pellet so that the seed can be discharged from the seed-supplying tube in the impact-type seed-metering device. Results of the tests showed that mean seeding spacing was 12cm at the traveling speed of 1.0m/s, corresponding to a target spacing for planting of rice-seed pellets. Also, both miss-seeded rate and damaged-seed rate were less than 2.0%, indicating acceptable levels for the precision planting. The developed mechanism of the impact-type metering device can be directly applied to the design of metering devices for the precision pellet planting of other crops.

  • PDF

Development of a Metering Device for a Garlic Clove Planter

  • Choi D. K.;Cho S. C.;Park S. H.;Kim J. Y.;Kim S. H.;Kim C. K.
    • Agricultural and Biosystems Engineering
    • /
    • v.5 no.2
    • /
    • pp.45-49
    • /
    • 2004
  • Objective of the study was to develop a garlic clove metering device. The metering device consisted of a drum, a bucket and a bucket cover. A garlic clove simulator was designed to simulate motions of garlic cloves in the metering device. Simulation was performed using a multibody dynamic analysis program, RecurDyn version 5.1. Physical properties of garlic cloves such as mass and center of gravity were determined using 3D CAD modeler, IDEAS version 10.0. In order to compare the results of the simulation with actual movement of a garlic, movement of garlic clove was photographed by a high speed camera. A prototype metering device was built and tested under various metering speeds and metering guide angles. At the 12 rpm metering speed, rate of single-clove-discharge was $90.0\%$ and missing rate $1.3\%$ at $5^{\circ}$.

  • PDF

Development of a Metering Device for the Garlic Planter (마늘파종기용 배종장치 개발)

  • 최덕규;조성찬;이채식;박석호;김학진;강태경;김충길;곽태용
    • Journal of Biosystems Engineering
    • /
    • v.26 no.6
    • /
    • pp.525-534
    • /
    • 2001
  • Garlic clove planting is one of the most laborious operations in Korean farming. The garlic planting has been done manually; therefore, it requires tremendous amounts of human labor resulting in the increase of production cost. This problem necessitated the development of a garlic clove metering device fur the planter. The device was fabricated to meter a single garlic clove with a scooping bucket(29mm in diameter and 8mm in depth) designed after the image of clove's bottom shape. The lift angle of the metering plate and the magnitude of vibration were also affected the metering performance. The angle clove metering rates ranged 95.4~96.7% with the missing rate of 0.0~1.3% at the 80~85 degrees of the tilt angle and vibration level 2(1.985 m/s$^2$).

  • PDF

A Study on the Coordinated Traffic Responsive Ramp Metering Control considering Spatial Equity (공간적 형평성을 고려한 통합 감응 램프미터링 제어 연구 -고속도로 진입로 중심으로-)

  • Yoon, Jae Yong;Shin, Hyoung O;Lee, Eui Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.361-367
    • /
    • 2019
  • Ramp metering is a traffic management technique that reduces the congestion of Expressway by controlling vehicles entering the highway. It is widely used outside the country, and Korea is also operating in seven sites (Seoul Ring Expressway). Ramp metering has the advantage of reducing congestion of Expressway, but there are disadvantages, as queuing occurs because vehicles are waiting for ramp, and the ramp queue affects adjacent roads at rush hour. To solve this problem, we improved the ramp metering algorithm to reduce the metering rate more spaces on ramp and to increase the metering rate less spaces. In order to evaluate this, the combined evaluation index was used and it was found that the result satisfied the equity and efficiency at the same time.

Development of a Low -Cost and Precise Liquid Metering Device for Automatic Nutrient-Solution Control (양액 자동조제용 액제 정밀계량 장치 개발)

  • 이정훈;류관희;이규철
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1997.12a
    • /
    • pp.255-262
    • /
    • 1997
  • A low-cost and precise metering device, which is suitable to automatic mixing of nutrient-solution for hydroponic culture, was developed for small-scale growers. The metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. Those parts were controlled by personal computer with time-based odoff control method. To verify the performance of the developed metering device, the relationship between operating time and discharge was examined and the accuracy of the developed metering device was compared with commercial metering pumps. The results of this study are as follows. 1. The correlation coefficient between the flow rate and operating time was 0.9999, and the linear regression equation computed was y=21.759x, where y is the discharge(g) and x is the operating time(s). 2. The developed device has greater accuracy than commercial metering pumps in terms of the full-scale error. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3 %, $\pm$2.45 % and $\pm$1.38 % respectively. 3. Above results show developed metering device is a useful tool for nutrient-solution control system.

  • PDF

Development of an Automatic Nutrient-Solution Supply System Using Fuzzy Control (퍼지제어를 이용한 양액 자동공급 시스템 개발)

  • 황호준;류관희;조성인;이규철;김기영
    • Journal of Biosystems Engineering
    • /
    • v.23 no.4
    • /
    • pp.365-372
    • /
    • 1998
  • This study was carried out to develop a nutrient-solution mixing-and-supplying system, which used a low-cost metering device instead of expensive metering pumps and a fuzzy logic controller. A low cost and precise overflow-type metering device was developed and evaluated by testing the flow discharge for the automatic nutrient-solution mixing-and-supplying system for snail-scale hydroponic sewers. The fuzzy logic controllers, which could predict and meet the desired values of EC and supply rate of nutrient solution were developed and verified by simulation and experiment. this fuzzy logic controller, whose algorithm consists of four crisp inputs, two crisp outputs and nine rules, was developed to predict the desired value of EC and supply rate of nutrient solution and two crisp inputs, one crisp output and nine rules used to control EC to the desired values. The nutrient-solution mixing-and-supplying system showed satisfactory EC control performance with the maximum overshooting of 0.035 mS/cm and the maximum settling time of 15 minutes in case of increasing 0.7 mS/cm. also, the accuracy of the overflow-type metering device in terms of the full-scale error was 2.29% when using solenoid valve only and 0.2% when using solenoid valve and flow control valve together.

  • PDF

A Study on the Transaction Volume Calculation model for Improving the Measurement Accuracy of Hydrogen Fuelling Station (수소충전소 계량 정확도 향상을 위한 거래량 산출 모델 연구)

  • JINYEONG CHOI;HWAYOUNG LEE;SANGSIK LIM;JAEHUN LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.692-698
    • /
    • 2022
  • With the expansion of domestic hydrogen fuelling station infrastructure, it is necessary to secure reliability among hydrogen traders, and for this, technology to accurately measure hydrogen is important. In this study, 4 types of hydrogen trading volume calculation models (model 1-4) were presented to improve the accuracy of the hydrogen trading volume. In order to obtain the reference value of model 4, and experiment was conducted using a flow rate measurement equipment, and the error rate of the calculated value for each model was compared and analyzed. As a result, model 1 had the lowest metering accuracy, model 2 had the second highest metering accuracy and model 3 had the highest metering accuracy until a certain point. But after the point, model 2 had the highest metering accuracy and model 3 had the second metering accuracy.

A Study on the Flow Analysis According to Impeller Speed for City Water Supply Measuring Valve (상수도용 계량 밸브 임펠러 회전수에 따른 유동해석에 관한 연구)

  • Tea-Joon Kim;Chung-Seob Yi;Chi-Woo Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.2_2
    • /
    • pp.307-313
    • /
    • 2023
  • This study conducts the flow analysis on the basis of the impeller RPM of water metering valve. The software used for the flow analysis is STAR-CCM+. In terms of the structure of the metering valve, it has an impeller installed inside, and a metering chamber has inlet and outlet holes. The flow analysis on the water metering valve drew the following conclusions: Regarding the flow field in the valve, the impeller had the highest velocity distribution, and complex flow field was generated in the metering chamber. In particular, since the path between the inlet and outlet holes in the metering chamber and the valve body was narrow, there was a section that had flow field interference. The flow rate and flow coefficient distribution according to the impeller RPM were on the linear increase. Given that, it showed the feature of the valve used for water metering on the basis of the impeller RPM.