• Title/Summary/Keyword: Meter-in circuit

Search Result 81, Processing Time 0.023 seconds

Characterics of Meter-In / Meter-Out Circuits to pneumatic System (공압회로에서 미터인 회로와 미터아웃 회로의 특성 비교)

  • 박재범;염만오
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.446-450
    • /
    • 2002
  • Pneumatic system has been mainly used as main equipment for actuation and control of compressed air force in manufacturing industry, pneumatic circuit for the most part is used in Meter-Out circuit. Meter-Out circuit method is Flow Control Valve to fit in exhaust part of cylinder port. In the reverse, Meter-In circuit is Flow Control Valve to fit in input part of cylinder port. This study examines the dynamic characteristics comparison of Meter-In and Meter-Out Circuits in the pneumatic circuits. The results of the experimental research are obtained to the followings: i ) System Response is Meter-In Circuit more than Meter-Out one before cushion zone. ii) we conjectured that the collision of piston and head cover is ease to collide Meter-In Circuit more than Meter-Out one at the stroke end part.

  • PDF

The Effects of Dynamic Viscosity and Load od Hydraulic Oil on Pressures (유압유의 동점도와 부하변화에 따른 압력의 영향)

  • 박주석;김일수;손준식;안영호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.573-576
    • /
    • 1995
  • The realization by many industrial countries that manufacturing is a critical ingredient for attaining economic strength and stability has led to the development of automated systems which were proviously considered as gimmicks. The adaptive skill of the human operator is now being simulated and reproduced by computer that have become more powerful and less expensive. The work presented in this paper forms an investigation of the effects of dynamic viscosity and load of hydraulic oil an pressures with three different circuit(meter-in, meter-out and bleed off). The experimental results showed that pressures increase with an increase in dynamic viscosity and load in bleed off circuit, but there is no variation of pressure in meter-In meter-out circuit.

  • PDF

Design and Fabrication of Digital Water Meter Using a Variable Capacitor (가변 콘덴서를 이용한 디지털 수도미터의 설계 및 제작)

  • Park, Keun-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.3
    • /
    • pp.141-146
    • /
    • 2016
  • The AMR(automatic meter reading) system has been increasingly and widely used for its efficient and intelligent management, which is a technology that automatically collects consumption data from a water meter or energy metering device. The digital meter instead of the mechanical meter should be used in the system. Up to now, various types of sensor to measure the water flow rate have been used in the digital water meter, for example, reed switch, photo IR approximate sensor, ultrasonic sensor, electromagnetic sensor, etc. In this paper, a new sensing technology, where a variable capacitor and digital circuit were used for sensing the water flow rate, was proposed. The circuit was designed and verified by Pspice simulation. And a PCB board for the circuit was fabricated. After then, a prototype of digital water meter using a variable capacitor to measure the water flow rate was fabricated. The function tests of the fabricated digital water meter were performed, and it was found that the meter worked properly. Since the new technology has much better properties in terms of cost and power consumption compared to conventional technologies, it should be one of the major digital water meter technologies in the future.

Study on the High Sensitive Three Phase Power Factor Meter and Relay (고감도 삼상력률계전기에 관한 연구)

  • 박정후
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.16 no.1
    • /
    • pp.43-47
    • /
    • 1980
  • The author designed and tested the high sensitive three-phase power factor meter and relay circuit, and dealt with the circuit to detect the phase of the current and the voltage. An operational amplifier comparator circuit and two single-phase transformers are used to control and detect the phase angle between the current and the voltage. The results obtained are as follows: 1. Converting the sine wave input current into the constant amplitude rectangular wave form by using a transistor chopper circuit, the power factor can be measured precisely over the load current of 0.08 A. 2. Using the moving coil type current meter, the power factor meter can be read in uniform . scale all over the range. 3. Using the three-phase power factor meter, the power factor relay which works at any power factor can be made.

  • PDF

The effects of Load of Hydraulic Oil on Hydraulic Mechanism (유압유 부하가 유압기계에 미치는 영향)

  • 박주석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.72-74
    • /
    • 1998
  • The adaptive skill of the human operator is now being simulated and reproduced by computer that have become more powerful and less expensive. This paper is concerned with an investigation of the effects of dynamic load of hydraulic oil on pressures with three different circuit(meter-in, meter-out and bleed-off). The experimental results showed that pressures increase with an increase in dynamic load in bleed-off circuit, but there is no variation of pressure in meter-in and meter-out circuits.

  • PDF

A Study on the Improvement of Test and Diagnosis Device for Audio Frequency Track Circuit (가청주파수 궤도회로의 진단 및 시험 장비 개선에 대한 연구)

  • Kang, Jang-Kyu;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.147-155
    • /
    • 2010
  • We studied on performance improvement of TTM(TI21 Test Meter) that is test and diagnosis devices for jointless audio frequency track circuit on Korean electric railway TI21 standard. Upgraded devices is AD-TTM(Advanced TI21 Test Meter). This can measure alternating frequency USB(Upper signal band) and LSB(Lower signal band). In the audio frequency track circuit, ${\pm}17[Hz]$ of nominal frequency are demodulated and supplied to track relay through AND gate. It is important that measurement function which is error between USB and LSB. Need of AD-TTM will stand out in the electric railway system because this is simple and accurate rather than the former device.

Measurements of X-Ray and Gamma Ray Dosse Rate by the Silicon P-N Junction Diode (Silicon P-N Junction Diode에 대한 X-Ray 및 Gamma-Ray 의 Dose Ratec 측정)

  • 정만영;김덕진
    • 전기의세계
    • /
    • v.13 no.3
    • /
    • pp.13-20
    • /
    • 1964
  • The measurements of X-ray and Gamma-ray Dose Rate have been successfully made by measuring the short circuit current of the Silicon P-N Junction Diode being irradiated. The short circuit current flows when a silicon P-N Junction Diode is irradiated by X-ray of Gammaray radiations due to photovoltaic effect. A brief analysis is given in order to verify the proportionality of a short circuit current to the Dose Rate. Using this method, measurements of X-ray Dose Rate were carried out in the range of 0.05-1600 r/m successfully. The calibration was made by comparing with Victoreen condenser r-meter. Some advantages in this Dose Rate meter over a condenser r-meter were found. One can measure a continous variation of X-ray Dose Rate with this rate meter at the control console of X-ray device.

  • PDF

Effects of Task-Oriented Circuit Class Training on Improves Performance of Locomotor in Disabled Persons after Stroke (과제-지향 순회 훈련이 뇌졸중 장애인의 이동 능력에 미치는 효과)

  • Kim, Soo-Min
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.447-454
    • /
    • 2011
  • Purpose : The purpose of this study was to identify the effects of circuit class training on the performance of locomotor tasks in chronic stroke. Methods : The study included 45 patients with chronic stroke randomly divided into experimetal group and control group. Both groups participated in exercise classes three times a week for 8weeks. The experimental group had 10 workstation of circuit class designed to improve walking. The control group practiced fitness exercises by equipment in health center. Walking performance was assessed by measuring walking speed(timed 10-meter walk and TUG), GAITRite analysis and peak vertical ground reaction force through the affected foot during walking. Results : The experimental group demonstrated significant improvement(p<.05) compared with the control group in 10-meter walking and vertical ground reaction force after training. The experimental group showed significant improvements in the walking velocity and cadence by GAITRite system(p<.05). Conclusion : Task- oriented circuit class training leads to improvements in locomotor function in chronic stroke. Further studies are necessary to occur in usual environments to improve walking performance.

Simulations and Circuit Layouts of HTS Rapid Single Flux Quantum 1-bit A/D Converter by using XIC Tools (XIC tools을 사용한 고온 초전도 Rapid Single Flux Quantum 1-bit A/D Converter의 Simulation과 회로 Layout)

  • 남두우;홍희송;정구락;강준희
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.131-134
    • /
    • 2002
  • In this work, we have developed a systematic way of utilizing the basic design tools for superconductive electronics. This include WRSPICE, XIC, margin program, and L-meter. Since the high performance analog-to- digital converter can be built with Rapid Single Flux Quantum (RSFQ) logic circuits the development of superconductive analog-to-digital converter has attracted a lot of interests as one of the most prospective area of the application of Josephson Junction technology. One of the main advantages in using Rapid Single Flux Quantum logic in the analog-to-digital converter is the low voltage output from the Josephson junction switching, and hence the high resolution. To design an 1-bit analog-digital converter, first we have used XIC tool to compose a circuit schematic, and then studied the operational principle of the circuit with WRSPICE tool. Through this process, we obtained the proper circuit diagram of an 1-bit analog-digital converter circuit. Based on this circuit we performed margin calculations of the designed circuits and optimized circuit parameters. The optimized circuit was laid out as a mask drawing. Inductance values of the circuit layout were calculated with L-meter. Circuit inductors were adjusted according to these calculations and the final layout was obtained.

  • PDF

Transistorized counting-rate meter (트랜지스터 계수율계)

  • 정만영;박계영
    • 전기의세계
    • /
    • v.15 no.4
    • /
    • pp.18-21
    • /
    • 1966
  • A transistorized counting-rate meter was designed by substituting one of diodes in the ordinary diode pumping circuit by the Darling's constant current source. Its circuit is so simple and stable that it is proper to use as a part of portable radiation detectors. Maximum readable counting rate is well above 100 kc/s and the linearity is very good. Output deviations due to the variations of embient temperatures are less than 5% in the temperatures from 20.deg. C to 40.deg. C.

  • PDF