• Title/Summary/Keyword: Meter set

Search Result 199, Processing Time 0.029 seconds

Meter Optimal Placement in Measurement System with Phasor Measurement Unit (페이저 측정 시스템의 측정기 최적배치)

  • Kim, Jae-Hoon;Cho, Ki-Seon;Kim, Hoi-Cheol;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1195-1198
    • /
    • 1999
  • This paper presents optimal placement of minimal set of phasor measurement units(PMU's) and observability of measurement system with PMU. By using the incidence matrix symbolic method which directly assigns measurement and pseudo-measurement to incidence matrix, it is much simpler and easier to analyze observability. The optimal PMU set is found through the simulated-annealing(SA) and the direct combinational method. The cooling schedule parameter which is suitable to the property of problem to solve is specified and optimal placement is proven by presented direct combinational method. Search spaces are limited within reasonable feasible solution region to reduce a unnecessary one in the SA implementation based on global search. The proposed method presents to save CPU time and estimate state vectors based on optimal PMU set.

  • PDF

A Case Study on Energy focused Smart City, London of the UK: Based on the Framework of 'Business Model Innovation'

  • Song, Minzheong
    • International journal of advanced smart convergence
    • /
    • v.9 no.2
    • /
    • pp.8-19
    • /
    • 2020
  • We see an energy fucused smart city evolution of the UK along with the project of "Smart London Plan (SLP)." A theoretical logic of business model innovation has been discussed and a research framework of evolving energy focused smart city is formulated. The starting point is the silo system. In the second stage, the private investment in smart meters establishes a basement for next stages. As results, the UK's smart energy sector has evolved from smart meter installation through smart grid to new business models such as water-energy nexus and microgrid. Before smart meter installation of the government, the electricity system was centralized. However, after consumer engagement plan has been set to make them understand benefits that they can secure through smart meters, the customer behavior has been changed. The data analytics firm enables greater understanding of consumer behavior and it helps energy industry to be smart via controlling, securing and using that data to improve the energy system. In the third stage, distribution network operators (DNOs)' access to smart meter data has been allowed and the segmentation starts. In the fourth stage, with collaboration of Ofwat and Ofgem, it is possible to eliminate unnecessary duplication of works and reduce interest conflict between water and electricity. In the fifth stage, smart meter and grid has been integrated as an "adaptive" system and a transition from DNO to DSO is accomplished for the integrated operation. Microgrid is a prototype for an "adaptive" smart grid. Previous steps enable London to accomplish a platform leadership to support the increasing electrification of the heating and transport sector and smart home.

The Effects of Coordinative Locomotion Training Using the PNF Pattern on Walking in Patients with Spinal Cord Injury (PNF 패턴을 결합한 협응적 이동 훈련이 척수손상환자의 보행에 미치는 효과)

  • Hwang, Sang-Su;Maeng, Gwan-Cheol;Kim, Jin-In;Jung, Chang-Wook
    • PNF and Movement
    • /
    • v.14 no.2
    • /
    • pp.67-74
    • /
    • 2016
  • Purpose: The purpose of this study was to prove the effects of coordinative locomotion training (CLT) on walking speed, walking endurance, and balance for incomplete spinal cord injury patients. Methods: Ten subjects were randomly assigned to the CLT group (n = 5) and the treadmill (TM) group (n = 5). The CLT group performed PNF pattern exercise using the motions of the sprinter and skater for 30 minutes, while the TM group performed using a treadmill for 30 minutes. Both groups performed these therapeutic interventions for five days per week, for a period of four weeks. A 10 meter walking test, Berg Balance Scale (BBS), and 6 meter walking test were used for the assessment of gait speed, balance, and gait endurance. The SPSS Ver. 18.0 statistical program was used for data processing. A Wilcoxon signed rank test was used for the comparison of pre- and post-intervention performance and a Mann-Whitney test was used for comparison between the groups. The significance level for the statistical inspection was set at 0.05. Results: Both groups showed significant improvements in the 10 meter walking test, Berg Balance Scale, and 6 meter walking test (P < 0.05). Conclusion: CLT had an effect on the improvement of walking speed, walking endurance, and the balance of incomplete spinal cord injury patients. Thus, we suggest that CLT is a therapeutic intervention for incomplete spinal cord injury patients.

A Study on the characteristics Torque and rpm for Varying Oil Quantity in Hydaultic Couplings (유체커플링의 작동유체량의 변화에 대한 토크와 회전수 특성에 관한연구)

  • 박용호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.241-247
    • /
    • 1998
  • The hydraulic coupling is a kind of power transmission device combined with pump turbine and casing as its main parts. The purpose of this research is to construct an experimental test set-up and to establish an available soft ware for th characteristics of two domestically developed hydraulic couplings. The test item is torgue rpm. and slip and or efficiency characteristic in accordance with variation of oil quantity. in this case the oil quantity was varied 55%, 67% and 77% of the inside capacity of hydraulic copuling.

  • PDF

A Study on the Rotary Tidal Current in the East China Sea (동지나해 어장의 회전 조류에 관하여)

  • 김진건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.22 no.2
    • /
    • pp.1-6
    • /
    • 1986
  • Even though it is well known that the tidal current in the East China Sea rotates clockwise, few report can be found about the precise pattern of it. To furnish some information available for the stow net fishermen, the author carried out the observation over 235 semidiurnal tidal cycle to investigate the pattern of the set and the rate of tidal current in the Korean fishing section 250 and 494, by reading the current meter and by tracing the corner reflectors with radar onboard the anchored obsen'ation vessel, from May 12, 1984 through February 27, 1986. The results obtained are as follows: 1. The mean semidiurnal tidal cycle was 12 h 20 m during spring tide, and 12 h 30 m during neap tide. 2. The mean interval from the calculated time of high water until the current began to set north was 2 h 30 m and 2 h 15 m in the fishing section 250 and 494 respectively, and the mean interval from the time of low water current began to set south was about 2 h 0 m in both sections. 3. In comparison of the occupied times to vary the set from one of 8 principal bearing points to the neighboring one, the shortest was while the set varied from N to NE and S to SW in the section 250 and 494 respectively. Contrary the longest was while the set varied from SE to S and from W to NW in the section 250 and 494 respectively. 4. In comparison of the rate while the set varied from one of 8 principal bearing points to the neighboring one, the fastest was while the set varied from SE to Sand NW to N in the section 250, and E to SE and W to NW in the section 494. Contrary the slowest was while the current set to NE and S W in the section 250, and N, NE and S W in the section 494.

  • PDF

Development of device measuring very high torque via torque arm with attached load cells (로드셀과 토크암을 이용한 대용량 토크 측정장치 개발에 관한 연구)

  • Lee, Y.B.;Han, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.1
    • /
    • pp.6-10
    • /
    • 2010
  • A measurement of very high torque for track drive unit in construction equipment is usually in difficulties due to the requirement of a torque meter with high capacity, and the limitation of geometry for an experimental set-up. To improve the troublesome problem, a new device was proposed, where a torque transmitted through the torque arm can be measured by load cells attached at each torque arm. The experimental set-up of the new device was carried out in order to measure the torque values for a mechanical feedback type planetary gear box, in which the power flow circulates itself in a closed-loop. The new device enables to measure torque values of 60,000Nm. Additionally, the measured values were estimated statistically in the aspect of their repeatability and reproducibility, so that an acceptable behaviour as a measuring device can be confirmed.

  • PDF

Simultaneous Adjustment of Closed Traverse Net Considered the Observed Angle and Distance (측각과 측거를 고려한 개합트래버스망의 동시조정)

  • 이계학
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.8 no.1
    • /
    • pp.51-56
    • /
    • 1990
  • Recently, Electronic Distance Meter(EDM) is widely used for the traverse surveying and trilateration net. In this study, the closed traverse network is precisely adjusted by simultaneous adjustment of the observed angle and distance, using the Electronic Total Stations (Set 3). And also, it is examined that each kind accidental errors appear observed angles according to the observed distance and the number of repeating angle. In addition to the result, of checking between the simultaneous adjustment, the compass rule and transit rule, simultaneous adjustment in combination of the observed angle and distance is more accurate and effective than other adjustment.

  • PDF

EFFECT OF MANDIBULAR SET BACK SURGERY ON VOLUMETRIC CHANGE AND BITE FORCE OF MASSETER MUSCLE (하악전돌증환자에서 악교정수술후 저작근의 부피 및 교합력의 변화)

  • Seol, Jung-Eun;Lee, Myung-Hwan;Kim, Chang-Soo;Hong, Jong-Rak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.300-305
    • /
    • 2008
  • Purpose: The purpose of our study was to evaluate the volume of pre- and post operative masseter muscle and bite force in mandibular prognathic patients treated with SSRO with the use of the 3D CT imaging technique and occlusal force meter. Materials and methods: The study group consisted of 12 patients with mandibular prognathism (5 males and 7 females) who underwent mandibular setback surgery (BSSRO) in the Department of Oral and Maxillofacial Surgery, Samsung medical center. Bite force was measured at pre op, post op 3, 6 and 12 months by occlusal force meter(GM10, Nagano Keiki, Japan) The preoperative CT examination of subjects was performed between one month prior to operation and one year after to operation. And muscle volume was measured. Result: As compared to preoperative measurements at 1 year postoperatively the masseter & internal pterygoid muscle volume were diminished (p<0.05) The bite force steadily recovered, so at postoperatively 6 months reached the preoperative level. And at 1 year after operation, the maximum bite force was significantly greater than preoperative levels. No significant correlation was presented between masseter muscle and bite force (p>0.05), internal pterygoid muscle and bite force (p>0.05). Conclusion: In this study, the results showed that volume and bite force of the masticatory muscles decreased significantly immediate after orthognathic surgery for mandibular set-back. However, reduction of maximum bite force disappears within 6 months after surgery.

Estimation of Setting Time of Concrete Using Rubber Hardness Meter (고무경도계를 이용한 콘크리트의 응결시간 추정 가능성 분석)

  • Han, Min-Cheol;Han, In-Deok;Shin, Yong-Sub
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.358-366
    • /
    • 2019
  • The purpose of this study is to explore the possibility of estimating optimum surface finishing work time of the fresh concrete placed at the job site by applying a surface hardness test meter(Durometer). Tests are carried out by measuring and comparing the Proctor penetration resistance test and hardness test by Durometer. Correlations between Procter penetration test and hardness test by Durometer were obtained. Two different types Durometer were applied to estimate setting time. Test results indicate that the measurement of the Durometer and the test of the Proctor penetration resistance are highly correlated. When measuring the initial setting time with Durometer, initial setting time is reached when the hardness value by the type C Durometer is reached around 42HD, and when final setting is measured with the type D Durometer, the surface finishing work time limit and curing time can be estimated with 10HD of Durometer.

Development of Neutron Induced Prompt γ-ray Spectroscopy System Using 252Cf (252Cf 선원을 이용한 즉발감마선 계측시스템 구성)

  • Park, Yong-Joon;Song, Byung-Chul;Jee, Kwang-Yong
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2003
  • For the design and set-up of neutron induced prompt ${\gamma}$-ray spectroscopy system using $^{252}Cf$ neutron source, the effects of shielding and moderator materials have been examined. The $^{252}Cf$ source being used for TLD badge calibration in Korea Atomic Energy Research Institute was utilized for this preliminary experiment. The ${\gamma}$-ray background and prompt ${\gamma}$-ray spectrum of the sample containing Cl were measured using HPGe (GMX 60% relative efficiency) located at the inside of the system connected to notebook PC at the outside of the system (about 20 meter distance). The background activities of neutron and ${\gamma}$-rays were measured with neutron survey meter as well as ${\gamma}$-ray survey meters, respectively and the system was designed to minimize the activities. Prompt ${\gamma}$-ray spectrum was measured using ${\gamma}$-${\gamma}$ coincident system for reduce the background and the continuum spectrum. The optimum system was designed and set up using the experimental data obtained.