• Title/Summary/Keyword: Meter set

Search Result 199, Processing Time 0.023 seconds

Isochronism of Feet in English Fixed Meter on Durational Measurement in Reading (영시 정형률의 음보 유형별 음향 분석을 통한 등시성연구)

  • Shin, Dong-Il
    • Proceedings of the KSPS conference
    • /
    • 2004.05a
    • /
    • pp.257-260
    • /
    • 2004
  • This study aims to define the isochronism of English feet. 275 feet, which consist of 66 lines of 13 poems written by 12 modem poets(The Poet Speaks, 1982), were used for analysis of durational measurement. To assess the average value of a foot, the study is, first, to set up a way of measuring the duration of each foot on its types in English meter. Secondly, with the measurement of the average duration of feet in modern poets' English poetries through Praat (version 4.119, 2003), it clarifies the foot isochronism in the fixed meter. With the two ways of measuring the isochronism, it clarifies the fact the foot isochronism permits the difference scope of the perceptive gap of 555.4-974.5msec. per foot in case of iambic meters in English poetry.

  • PDF

Effective thermal conductivity of the phase change material with metal scrap (금속스크랩이 혼합된 상변화물질의 유효열전도율)

  • 김시범;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.923-928
    • /
    • 1986
  • A set of measurements has been made for the thermal conductivity of the pure paraffin in liquid and solid phases and for the effective thermal conductivity of the paraffin with metal scrap with the aid of the heat flux meter. Ther thermopile-type heat flux meter has been designed by steady state method and the functional relation between the temperature difference of both sides and heat flux has been obtained. The measured values of thermal conductivity are compared with the existing data for the pure paraffin and with the predicated values from the suggested model in which only one empirical constant is contained. The comparison within ten percent of the volume fraction of the metal scrap in the paraffin is satisfactory.

Study on the Calibration System of Flow Meters in Partly Filled Pipes (비만관 유량계 교정 시스템 구축에 관한 연구)

  • Yoo Sung-Ho;Lee Dong-Rak;Lee Min-Soo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.4 s.37
    • /
    • pp.7-12
    • /
    • 2006
  • Flow meters in partly filled pipes are set up and run in Korea nowadays, but there are no standard calibration procedures for the flow meters in accordance with ' ISO/IEC 17025. The standard calibration procedure based on the standard calibration procedures for flow meter in closed conduits and the technical notes of flow meter's makers ' is developed. The measurement uncertainty of the calibration for the flow meter in partly filled pipes is evaluated.

A study on torque measuring technique for track drive unit of earthmoving equipment with very large capacity (대형 건설장비용 주행유닛의 토크 측정기술에 관한 연구)

  • Lee, Yong-Bum;Han, Seung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.4
    • /
    • pp.97-103
    • /
    • 2009
  • Since a demand for an extensive range of earthmoving equipment like a hydraulic excavator with a capacity of 85tons has been asked in construction fields, a performance of its track drive unit has to be verified experimentally. Among the verification of the performances, a torque measurement is at issue, in which a torque meter is utilized widely. However, the very large scaled torque meter is necessary when a discharged torque from the track drive unit is increased significantly. In addition, the price for experimental set-up of a torque meter is too high due to its limitation of the geometry such as long length, and a break down in operation occurs frequently. In this study, to measure a high torque up to 200,000Nm, a new technique was proposed as an alternative of conventional measurement by using a torque meter. The new technique enables to measure the high torque stably in a compact space via a torque arm and two load cells. The experimental results showed a propriety of the proposed torque measuring technique for a track drive unit with very large capacity.

  • PDF

Ultrasound Probe Contamination Classification using ATP Meter (ATP meter를 이용한 초음파 탐촉자의 오염도 분류)

  • Ha, Myeong-Jin;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.43 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, the contamination level was measured using an ATP meter using adenosine triphosphate bioluminescent material to find effective infection control to compensate for the disadvantages of the microbial culture method used for hygiene control of ultrasound probe. The convex probes were selected from six ultrasound probe in the hospital, and the samples were taken in real time before and after cleaning to check the contamination of the probe. In order to classify the pollution degree using the APT meter was classified by category. A total of 78 samples were collected from the ultrasound probe. When the pollution levels before and after cleaning were classified by category, 76.6% of the samples were classified into category 3·4 before cleaning, but they decreased to 23.3% after cleaning. 13.3% before cleaning was in category 1, but increased to 43.3% after cleaning. By classifying the pollution level, it was confirmed that the pollution level was significantly reduced by category. Until now, there was no suitable criterion for determining the contamination level by using ATP meter in medical machines where sample area is small and reused. In this study, criteria for each category were set to measure the contamination level of ATP meter suitable for small sample area such as ultrasound probe, so that contamination level could be determined in real time at the site. Therefore, it is considered that hygiene management for ultrasound probe can be more actively performed.

The statistical analysis for cognizance on the Chinese oriental medical doctor of the pulse meter-analyzer (중의사의 맥진기 인식에 대한 통계 분석 연구)

  • Kim, Gyeong-Cheol;Kim, Jong-Hwan;Shin, Woo-Jin;Lee, Hai-Woong;Park, Ju-Yeon;Hong, Sang-Min;Doo, Seung-Hee;Kang, Hee-Jung;Yingri, Zhao
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.13 no.2
    • /
    • pp.88-116
    • /
    • 2009
  • Background : EBM (the evidence based medicine) is the direction of the development for oriental medicine. The pulse meter-analyzer is the important part to standardize the pulse diagnosis. When we set up the direction of the study on the pulse meter-analyzer, the awereness about the pulse meter and analyzer of the clinical oriental medical doctors as consumers is very important. Objectives : In order to prepare for the mutual study and the export strategy on the pulse meter-analyzer of Korea and China, the attitude of the study and the grasp of the awereness about the pulse meter-analyzer of the Chinese medical doctors are very important. Methods : We developed the several items as the important factor of the development of the pulse meter and analyzer. They were translated by chinese medical doctor. The investigation for demend was conducted during 3 months in Guangzhou City, Guangdong Province, China. The results of the investigation was done the statistical method of frequency analysis, Chi-squared test, correspondence analysis. Results : The most important differentiation of symptom is the symptom of JANG-BU(臟腑). The method of the utility in the pulse diagnosis is Chon-Gu (寸口) pulse diagnosis and the research on Chon-Kwan-Cheok(寸關尺) is the most important measurement factor. And the typical the old pulse is the little-fine weak pulse. The pulse meter-analyzer is most suitable to the diagnosis of the hypertension and the arteriosclerosis. Conclusion : The development of the pulse analyzer including the requests of Korean and Chinese medical doctors is very important. Specially the researches on the influence factors of the traditional diagnosis and the environment of the measurement are important for developing the pulse analyze.

  • PDF

Study on the Preparation and Properties of 1-Step Twisted NylonYarns (1-Step 연사공정 적용 나일론 연사물의 제조 및 특성 연구)

  • Lee, Jun Young;Jeon, Jae Woo;Park, Dong Kyu;Seo, Young Ho;Im, Young Min;Oh, Tae Hwan
    • Textile Coloration and Finishing
    • /
    • v.31 no.4
    • /
    • pp.332-340
    • /
    • 2019
  • Due to the change in lifestyle, new sensible materials for sportswear and outdoor are needed. This study is conducted in order to obtain the data for sensible materials through nylon twist process. 1-step nylon twisting machine was used to set the optimum twist process. DSC measurements of twisted nylon yarn showed crystallization temperatures around 170℃ and melting temperatures around 220℃. Nylon 40D/13F DTY and Nylon 50D/48F DTY showed optimal results at 160℃, 1,500 T/M(Turns per meter), and Nylon 70D/68F DTY at 160℃, 1,200 T/M(Turns per meter) after 1-step twist process. Also, Nylon 40D/13F DTY was confirmed to have inter-layer property deviation of ±5 percent.

Development of an IV Infusion Rate Regulator Using Optical Drip Rate Meter (광센서 점적계를 이용한 정맥내 주입률 조절기의 개발)

  • Yang, Y.S.;Kim, H.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.127-128
    • /
    • 1998
  • It is necessary to maintain constant intravenous (IV) infusion rate. While infusion pump is able to control infusion rate with great accuracy, its rather large size and weight make it difficult for patients to move around. The most commonly used infusion device is gravity IV infusion set with its administration chamber being clamped according to the observed drip rate. In this case it may be easier and more accurate to maintain IV rate to given value if we automate the drip-counting process and tube-clamping work by electronic devices. We calculated volume infusion rate of specific fluid using optical drip rate meter which we had developed. To regulate fluid flow rate, we equipped the rate meter which we had developed with a miniaturized clamping apparatus using DC motor. Also, we Implemented drip detection and clamp control algorithm with PIC16C73 $\mu$-controller (Microchip). This system provides user interface through LCD display and key buttons.

  • PDF

Constraints of English Poetic Meter (영시 정형율의 제약들 - Iambic을 중심으로 -)

  • Sohn Ilkwon
    • MALSORI
    • /
    • no.42
    • /
    • pp.71-88
    • /
    • 2001
  • This study is on the constraints of English Poetic Meter. In English poems, the metrical pattern doesn't always match the linguistic stress on the lines. These mismatches are found differently among the poets. The peaks mismatched with the weak metrical position are divided into the two ways according as they are adjacent to the boundary of a phonological domain or not. PAF and $^*UV$] are suggested for the mismatched peak which are not adjacent to the boundary of a phonological domain ; $^*Peak$] and BT for the mismatched peak which are adjacent to the boundary of a phonological domain. For the lexical stress mismatched with the weak metrical position, $^*W{\;}{\Rightarrow}{\;}Strength$ is set up by the concept of the strong syllable. $MPS{\;}{\Rightarrow}{\;}\Phi_{max}$ for the metrical position size can replace the resolution which is used to control the number of syllables in English poems. These constraints show the different hierarchies among the poets.

  • PDF

Measurement of Environmental Radiation according to Altitude above Sea Level in National Park (국립공원의 해발고도에 따른 환경방사선 측정)

  • Ji, Tae-Jeong;Lee, In-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.12
    • /
    • pp.694-701
    • /
    • 2012
  • This study set put to measure the environmental radiation for mountainous regions of National Parks where Integrated Environmental Radiation Monitoring Network is not installed. For the measurement method, the space dose was classified at 1 meter high from the surface and the index dose at the surface. The measured radiation energy measured gamma, alpha and beta rays. For selection of national parks, we selected 10 national parks which are within the same distribution in the southern part and central part of the nation. For measurement equipment, INTERCEPTOR$^{TM}$(Thermo, USA, 2006) was used for gamma rays. As for the results of the measurements, for the space gamma dose, a high level was measured at a sea level of 500 meter in national parks with an altitude of less than 1,000 meter. It was found that the value was more than $0.23{\mu}Svh^{-1}$ especially in Bukhan Mountain, Gyeryong Mountain and Wolchul Mountain. In national parks with an altitude of more than 1,000 meter, $1.77{\mu}Svh^{-1}$ was measured at 1,500 meter at Seorak Mountain. Therefore, this is 10 times greater than the background standard dose. The national parks were there were no significant changes in dose were Naejang Mountain, Sobaek and Jiri Mountains. For the measurement of the index dose, a high dose level was measured at middle altitudes of 500 meter and 1,000 meter. For measurement according to the composition types of crust, high doses were recorded at national parks composed of rocks and a lower environmental radiation level was measured at Hanra Mountain where volcanic activities have occurred.