• 제목/요약/키워드: Meter Accuracy

검색결과 264건 처리시간 0.024초

A Compact Tunable VCSEL and a Built-in Wavelength Meter for a Portable Optical Resonant Reflection Biosensor Reader

  • Ko, Hyun-Sung;Kim, Bong-Kyu;Kim, Kyung-Hyun;Huh, Chul;Kim, Wan-Joong;Hong, Jong-Cheol;Park, Seon-Hee;Yang, Seong-Seok;Jang, Ho-Jin;Sung, Gun-Yong
    • Journal of the Optical Society of Korea
    • /
    • 제14권4호
    • /
    • pp.395-402
    • /
    • 2010
  • This study reports a portable and precision photonic biosensor reader that can measure the concentration of a particular antigen using an optical resonant reflection biosensor (ORRB). To create a compact biosensor reader, a compact tunable vertical-cavity surface-emitting laser (VCSEL) and a compact built-in wavelength meter were manufactured. The wavelength stability and accuracy of the compact built-in wavelength meter were measured to be less than 0.02 nm and 0.06 nm, respectively. The tunable VCSEL emission wavelength was measured with the compact built-in wavelength meter, it has a fast sweep time (~ 10 seconds) and a wide tuning range (> 4 nm) that are sufficient for biosensor applications based on ORRB. The reflection spectrum of a plastic based ORRB chip was measured by the fabricated portable photonic biosensor reader using the VCSEL and wavelength meter. Although the reader is the size of a palmtop device, it could make a precise measurement of the peak wavelength on equal terms with a conventional bulky optical spectrometer.

도시철도 직류 전력량 계측을 위한 직류용 스마트미터링 시스템 개발 및 성능시험 (Development and Performance Test of DC Smart Metering System for the DC Power Measurement of Urban Railway)

  • 정호성;신승권;김형철;박종영
    • 전기학회논문지
    • /
    • 제63권5호
    • /
    • pp.713-718
    • /
    • 2014
  • DC urban railway power system consists of DC power network and AC power network. The DC power network supplies electric power to railway vehicles and the AC power network supplies electric power to station electric equipment. Recently, because of power consumption reduction and peak load shaving, intelligent measurement of regenerative energy and renewable energy adapted on DC urban railway is required. For this reason, DC smart metering system for DC power network shall be developed. Therefore, in this paper, DC voltage sensor, current sensor, and DC smart meter were developed and evaluated by performance test. DC voltage sensor was developed for measuring standard voltage range of DC urban railway, and DC current sensor was developed as hall effect split core type in order to install in existing system. DC smart meter possesses function of general intelligent electric power meter, such as measuring electricity and wireless communication etc. And, DC voltage sensor showed average 0.17% of measuring error for 2,000V/50mA, and current sensor showed average 0.21% of measuring error for ${\pm}2,000V/{\pm}4V$ in performance test. Also DC smart meter showed maximum 0.92% of measuring error for output of voltage sensor and current sensor. In similar environment for real DC power network, measuring error rate was under 0.5%. In conclusion, accuracy of DC smart metering system was confirmed by performance test, and more detailed performance will be verified by further real operation DC urban railway line test.

RTK-GPS에 의한 노선측량에서 이동국의 속도에 따른 정확도 분석 (Accuracy Analysis of RTK-GPS Rover Speed in Route Surveying)

  • 최병길;이형수
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 춘계학술발표회논문집
    • /
    • pp.139-144
    • /
    • 2004
  • This study aims to analyze the accuracy of rover speed change in route surveying using RTK-GPS. Route surveying methods using GPS contain Static, DGPS, and RTK-GPS. Much research of navigation system, positioning of vehicles by DGPS, and accuracy analysis by GPS surveying have already been done. From this study, it is firstly found that DGPS is suitable for car navigation and sea navigation with an error of meter scale but not good for detailed construction, designing maps and updating GIS databases. Secondly, RTK-GPS can be used for managing gas pipes, water supply and drain pipes and fiber-optic cable that are needed to be controlled in a real time basis. Thirdly, since the accuracies of route surveying by RTK-GPS and DGPS are not correctly matched with the change of rover speed, the choice of route surveying method from those two should follow the need of accuracy fidelity Further study should focus on Cycle Slip problem and coordinate change problem in tunnel and mountainous areas.

  • PDF

스마트 기기 환경에서 전력 신호 분석을 통한 프라이버시 침해 위협 (Threatening privacy by identifying appliances and the pattern of the usage from electric signal data)

  • 조재연;윤지원
    • 정보보호학회논문지
    • /
    • 제25권5호
    • /
    • pp.1001-1009
    • /
    • 2015
  • 스마트 그리드 안에서 고안된 스마트 미터는 우리가 사용하는 전력 신호를 실시간으로 데이터화해서 전력 공급단의 메인 서버로 전송한다. 이를 통해 전력 관리의 효율성은 증가한 반면, 사용자의 정보를 담은 데이터의 보안 문제가 새로운 위협으로 부상하였다. 본 논문은 스마트 미터에서 추출한 전력 데이터를 통해 가정 내 기기의 식별 및 기기별 사용패턴에 대한 추론을 보안 관점에서 해석함으로써 스마트 기기 환경에서 데이터 노출의 위협을 지적한다. 주성분분석(Principal Component Analysis)으로 데이터의 특징을 추출하였고 k-근접 이웃(k- Nearest Neighbor)분류기로 기기를 식별하고 기기상태를 추론하였으며, 검증방법으로는 10차 교차검증(10-fold Cross Validation)을 활용하였다.

특정 레벨을 검출하기 위한 2단 Magnetic Float 타입 레벨 게이지의 최적 설계에 관한 연구 (Optimal design of dual magnetic float type level gauge to detect a specific level)

  • 김동석;한재만;박관수
    • 센서학회지
    • /
    • 제17권4호
    • /
    • pp.308-316
    • /
    • 2008
  • For the measurement of liquid level in ship's cargo tank, ballast tank, fuel oil tank and fresh water tank, several types of gauge meter are used such as tubular type, magnetic float type, reflex type transparent type and welding pad type. Among them, magnetic float type gauge meter is environmental friendly device because it is free of power source and maintenance. The main obstacle of the device is relatively large error bound. In this paper, finite element method is used to design and analysis of the magnetic float type gauge meter. The operation of reed switch according to the magnetic field has been successfully described and agreed well with experimental measurement. The optimum geometry with combination of permanent magnet and reed switches are designed to achieve 98 % accuracy of fluid level.

광센서 점적계를 이용한 정맥내 주입률 조절기의 개발 (Development of an IV Infusion Rate Regulator Using Optical Drip Rate Meter)

  • 양윤석;김희찬
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.127-128
    • /
    • 1998
  • It is necessary to maintain constant intravenous (IV) infusion rate. While infusion pump is able to control infusion rate with great accuracy, its rather large size and weight make it difficult for patients to move around. The most commonly used infusion device is gravity IV infusion set with its administration chamber being clamped according to the observed drip rate. In this case it may be easier and more accurate to maintain IV rate to given value if we automate the drip-counting process and tube-clamping work by electronic devices. We calculated volume infusion rate of specific fluid using optical drip rate meter which we had developed. To regulate fluid flow rate, we equipped the rate meter which we had developed with a miniaturized clamping apparatus using DC motor. Also, we Implemented drip detection and clamp control algorithm with PIC16C73 $\mu$-controller (Microchip). This system provides user interface through LCD display and key buttons.

  • PDF

휴대용 용존산소 측정 시스템의 설계 및 제작 (Design and Fabrication of Portable Dissolved Oxygen Measurement System)

  • 장중원;이성필
    • 융합신호처리학회논문지
    • /
    • 제9권3호
    • /
    • pp.219-223
    • /
    • 2008
  • 스크린 프린트법으로 저가형 후막 용존산소 센서를 제작하고, 휴대용 용존산소 측정 시스템을 구현하였다. 전류 특성은 인가전압(바이어스 전압)을 0.7 V로 하였을 때, 응답시간도 짧고 전류 값의 변화도 가장 크다는 것을 알 수 있었다. 시스템의 구현은 MCU, 증폭단, 필터단, 전원부 및 디스플레이로 구성하였다. 용존산소 농도는 아날로그 값을 디지털로 변환하여 백분율로 표현되도록 프로그램하였다. 제작된 용존산소 측정 시스템은 표준 용액 대비 오차 ${\pm}0.5%$의 정확도 및 약 100초의 응답시간을 나타내어 고가의 상용 용존산소 센서를 대치할 수 있을 것으로 기대된다.

  • PDF

AMI 계량데이터의 검증 신뢰성 및 추정 정확도 향상을 위한 VEE 알고리즘 개선 연구 (A VEE Algorithm Improvement Research for Improving Estimation Accuracy and Verification Responsibility of The AMI Meter Data)

  • 이재관;신진호;주용재;노재구;박영배;정남준
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.557-562
    • /
    • 2016
  • 계량데이터 관리 시스템은 수용가에서 검침된 계량데이터를 수집하고 관리하는 시스템이다. 이 시스템에는 검침된 데이터의 오검침과 유효성을 판단하는 검증과 누락된 검침값이나 오검침으로 판단된 구간값을 추정하는 VEE 알고리즘이 있다. 그러나 기존의 VEE 알고리즘은 현장 데이터의 특성을 반영하지 않고 검증하고 추정하기 때문에 그만큼 신뢰성과 정확도가 낮아지는 단점이 있다. 본 논문에서는 검증 신뢰성과 추정 정확도를 향상시킬 수 있는 차세대 VEE 알고리즘을 제안한다.

비압축성 시간식 질량유량계의 특성에 관한 연구 (An experimental study of Incompressible time based mass flow controller)

  • 장영철
    • 반도체디스플레이기술학회지
    • /
    • 제7권3호
    • /
    • pp.55-58
    • /
    • 2008
  • The objective of this research is to design, manufacture and test a mass flow controller capable of measuring compressible as well as incompressible fluid flows based on a 'bucket and stop-watch' method. The basic principle behind such a system is the measurement of time, where the time taken to fill and empty a bucket of known volume is measured. This device should be able to handle fluid flows in the range of 0.1 ml/min to 10 ml/min within an accuracy of ${\pm}$1%. For the flow meter to be able to compete with established designs, it must be not only comparable in cost and robustness, but also very accurate and reliable as well.

  • PDF

Measurement of suction air amount at reciprocating engine under stationary and transient operation

  • Kubota, Yuzuru;Hayashi, Shigenobu;Kajitani, Shuichi;Sawa, Norihiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1037-1042
    • /
    • 1990
  • The air-fuel ratio of an internal combustion engine must be controlled with accuracy for the improvements of exhaust emission and fuel consumption. Therefore, it is necessary to measure the exact instantaneous amounts of fuel and suction air, so we carried out the experiments for measuring the air flow velocity in a suction pipe of an internal combustion engine using three types of instantaneous air flowmeter. The results obtained can be summarized as follows: (1) The laminar-flow type flowmeter is able to measure both the average and the instantaneous flow rate, but it is necessary to rectify the pulsating air flow in the suction pipe. (2) The a spark-discharge type flow velocity meter is able to measure the instantaneous air velocity, but it is necessary to choose the suitable electrode form and the spark character. (3) The tandem-type hot-wire flow velocity meter indicates the instantaneous flow velocity and its flow direction.

  • PDF