• 제목/요약/키워드: Meter Accuracy

검색결과 264건 처리시간 0.028초

오리피스 유량계와 터빈 유량계의 직관부길이와 유동안정기에 관한 연구 (A Study of Straight Pipe Length and Straightener in Orifice Meter Turbine Meter)

  • 허재영;안승희;이강진;이승준
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.265-271
    • /
    • 2000
  • Orifice meters and turbine meters are frequently used for measuring gas flow in gas industry. However, to insure the accuracy of the measurement, a certain length of the meter run at the upstream of the flow meter is required. The objective of this study is to analyze flow measurement errors of the orifice meter quantitatively for shorter lengths of the meter runs than those suggested in the standard manuals with variation of diameter ratio( $\beta$ ratio) and flow rate and also to analyze flow measurement errors of the turbine meter with and without straightener. The test results showed that the flow measurement errors of the orifice meter were inversely proportional to the diameter ratio. In other words, when the diameter ratio is 0.3 and 0.7, the measurement error is $-7.3\%$ and $-3.5\%$, respectively. the main reason of the measurement error is due to the swirl effect from the configuration of the meter run at the upstream of the flow meter. In case the length of the meter run is shorter than that suggested In the standard, the swirl effect is not removed completely and it affects the flow meter's performance. As mentioned above, the less the pipe diameter ratio, the mon the flow measurement error. It means that the swirl effect on the orifice meter increases as the $\beta$ ratio decreases.

  • PDF

자계 센서를 이용한 원격 가스 검침 시스템 (Remote gas meter-reading system using magnetic sensor)

  • 구자일
    • 대한전자공학회논문지TE
    • /
    • 제39권2호
    • /
    • pp.90-94
    • /
    • 2002
  • 본 논문은 자계센서를 이용하여 원격 가스 검침 시스템을 구현하였다. 현재까지 개발되고 있는 스캔 방식은 온도, 습도, 분진, 진동에 영향을 많이 받는다. 이런 문제점을 해결하기 위하여 본 논문은 가스의 유입량에 따라 회전하는 체인지기어의 가장자리에 영구자석을 부착하고, 계량기 몸체의 외벽에 영구자석의 자기장을 측정할 수 있는 홀 소자를 설치하였다. 체인지 기어에 의해 영구자석이 회동하여 홀 소자에 근접할 때 자기장을 검출하고, 그 검출된 신호를 카운트함으로써 가스 사용량을 검침하였다. 이 방식은 온도, 습도, 분진, 진동에 영향을 받지 않았으며, 높은 정확도를 나타내었다.

정수장에서 배출수 공정 자동화를 위한 초음파 다중빔 슬러지 농도계 개발 (Development of Ultrasonic Multi-Beam Sludge Meter For Effluent Facilities Automation)

  • 장상복;홍성택;전명근
    • 한국정보통신학회논문지
    • /
    • 제18권9호
    • /
    • pp.2313-2321
    • /
    • 2014
  • 정수장, 하수처리장, 폐수처리장의 배출수 처리공정에서 고 농도의 슬러지 선별, 이송 및 약품 투입량 조절을 위한 기준으로 슬러지 농도계가 사용되고 있다. 본 논문은 슬러지 농도계의 정도 향상과 문제점 개선을 통해 배출수 처리공정의 운영 효율화와 자동화 기반을 마련하고자 한다. 센서를 다중빔으로 설계 및 최소편차 선형평균 필터링을 적용하여 농도계의 정도 향상과 안정성을 실현하였으며, 부단수 방식의 센서 착탈 설계로 배출수 시설 운영중에도 유지관리가 가능토록 하였다. 이렇게 구현된 다중빔 방식 슬러지 농도계의 성능을 Pilot Plant를 통하여 다양하게 검증하였다.

유량측정 기기별 측정성과에 대한 실험적 비교분석 (Experimental Comparison and Analysis of Measurement Results Using Various Flow Meters)

  • 이재혁;이석호;정성원;김태웅
    • 한국습지학회지
    • /
    • 제12권1호
    • /
    • pp.95-103
    • /
    • 2010
  • 유량자료는 물의 순환과정을 규명하고 효율적인 수자원 개발 및 이수 치수 계획 등에 매우 귀중하게 이용된다. 그러나 이러한 유량자료를 확보하는데 많은 시간과 경비 등이 요구되기 때문에 주요 수위에서 유량자료는 수위-유량관계곡선식(Stage-Discharge Curve)을 개발하여 유량을 산정하고 있다. 따라서 수위-유량관계곡선식의 신뢰도는 유량자료의 품질에 절대적인 영향을 미치는 요인으로 작용된다. 수문학을 전공하고 연구하는 많은 학자들은 고품질의 유량자료를 생산하여 신뢰성 있는 곡선식을 개발하고자 유량측정 방법과 기준, 장비개발 및 개량 등에 관한 연구를 수행하고 있다. 현재 국내에서는 다양한 유량측정기기를 사용하여 유량자료를 생산하고 활용하고 있으나, 측정기기별 정확도 및 실험적 측정성과에 대한 연구자료가 미흡한 실정이다. 본 연구에서는 규격화된 콘크리트 수로에 일정한 유량을 흘려보내는 조건에서 다양한 측정기기를 이용하여 유속을 측정하였다. 그리고 이 측정성과를 이용하여 유량을 산정하고 비교분석하였다. 실험을 위해서 국내에서 일반적으로 사용되고 있는 측정기기로 프라이스 유속계(USGS Type AA Current Meter), 휴대용 유량계(Flow Meter), 초음파식 디지털 유속계(ADC), C2 유속계(C2 Small Current Meter), 플로우 트렉커(Flow Tracker), 마그네틱 유속계(Electromagnetic Current Meter) 등의 장비를 사용하여 유량을 산정하였으며, 각 기기별 산정된 유량을 비교 분석 하였다. 비교검토에 적용하고자 측정한 수심으로는 0.30 m, 0.35 m, 0.40 m, 0.45 m, 0.50 m, 0.55 m의 왕복측정 6-Case로 진행이 되었으며, 신뢰성과 정확도를 높이기 위해 도섭법으로 수면에서 0.6d 지점의 유량측정방법(1점법)을 적용하였다. USGS Type AA Current Meter, Flow Meter, ADC, C2 Small Current Meter는 유속측정기기의 검교정을 받았으므로 다른 실험유량측정치의 비교를 위한 기준값으로 사용하였다. 따라서 국내에서 널리 사용되는 측정기기(USGS Type AA Current Meter, Flow Meter, ADC, C2 Small Current Meter, Flow Tracker, Electromagnetic Current meter)별 검토 결과 평균유량 및 평균유속에 있어 프라이스 유속계를 기준으로 마그네틱 유속계 $\pm$ 10 % 이상, 플로우 트렉커 $\pm$ 10 % 미만, 휴대용 유량계, 초음파식 디지털 유속계 및 C2 유속계는 $\pm$ 5 % 미만의 차이가 있음을 확인할 수 있었다.

2종의 측색기에 의한 도재 색조 재현의 정확성 비교 (Comparison on accuracy of porcelain color reproducibility using two colorimeters)

  • 이태일;안진수;김영수;신상완
    • 대한치과보철학회지
    • /
    • 제47권3호
    • /
    • pp.348-355
    • /
    • 2009
  • 연구 목적: ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan)와 Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany)의 도재색조 재현의 정확성을 비교연구하여 보고자 함이다. 연구 재료 및 방법: ShadeEye-Ncc dental chroma meter와 Shadepilot$^{TM}$ system을 사용하여 Vitapan 3D Master shade guide의 2M2와 3M2 shade tap.을 측색하고, 이 자료를 통하여 shade guide tap. 형태로 도재시편을 제작한다. 시편제작 시 사용하는 porcelain system은 ShadeEye-Ncc dental chroma meter는 Vintage Halo Porcelain system을, Shadepilot$^{TM}$ system은 VitaOmega900 Porcelain system을 사용한다. 모델인 shade tap.과 제작된 도재시편을 spectrophotometer로 측색하고, 그 결과를 토대로하여 ${\Delta}E$를 계산하여, 두 측색기의 정확성을 비교검증하였다. 결과: 1. Shadepilot$^{TM}$ system이 ShadeEye-Ncc dental chroma meter에 비하여 더 적합한 도재색조 재현성을 나타내었다 (P <.05). 2. 모델인 Shade tap.의 shade에 따라서 도재색조 재현성에 차이를 나타내었다. 2M2 shade tap.에 비하여 3M2 shade tap.에서 더 적합한 도재색조 재현성을 나타내었다 (P <.05). 3. 두 측색기 모두에서 제작된 도재시편의 ${\Delta}E$가 평균4.44-6.14로 육안으로 구분 가능한 정도의 색조차이를 보였다. 결론: Shadepilot$^{TM}$ system이 비교적 더 정확한 도재색조 재현성을 나타낸다고 할 수 있으며, ShadeEye-Ncc dental chroma meter를 사용할 때는 치아 전체의 여러부분에서 측색을 하여 정확성을 높이는 것이 필요하리라 생각된다.

하다마드변환을 이용한 광소자 정렬용 다채널 광파워메터 (Multiple Channel Optical Power Meter for Optical Alignment using Hadamard Transform)

  • 조남원;윤태성;박진배;곽기석
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권5호
    • /
    • pp.205-215
    • /
    • 2006
  • In this paper an optical power meter using Hadamard transform, which can be used in multiple channel optical elements alignment system, is proposed. A traditional optical power meter in multiple channel optical elements alignment system is able to judge how well the elements are aligned each other by measuring optical power of the first and the last two channels with at least two detectors. It has critical drawback that the alignment accuracy per channel is dependent on the number of detectors. The proposed optical power meter can get noise reduction by the Hadamard transform based multiplexing technique. The Hadamard transform based multiplexing technique using spatial light modulators is distinguished by the best enhancement of signal-to-noise ratio (SNR) for the reconstructed signals. Moreover, the noise reduction increases with increasing the order of multiplexing, namely the number of optical element channels. The proposed system is implemented by PDLC (Polymer Dispersed Liquid Crystal) mask which is operated by electric filed and generates optimal multiplexing patterns based on the Hadamard transform and single detector. It means that we obtain not only the each channel's optical power of multiple channel elements at once but also the best enhancement of SNR with single detector. Experimental results show that the proposed optical power meter is suitable for an active optical alignment system for multiple channel optical elements.

FPGA을 이용한 초음파 오일레벨 측정기 설계 (Design of a Ultrasonic Oil Level Meter Using a FPGA)

  • 조정연;강문호
    • 전자공학회논문지
    • /
    • 제49권11호
    • /
    • pp.167-174
    • /
    • 2012
  • 본 논문에서는 자동차 변속기 오일레벨을 측정하기 위한 초음파 오일레벨 측정기를 설계하고 실험을 통하여 유용성을 보였다. 측정기에 필요한 모든 디지털 회로를 FPGA 프로젝트 IDE상에서 하나의 FPGA를 이용하여 설계하여 측정기의 단순화와 고성능화를 이루었고, 측정기 개발 시간을 줄일 수 있었다. 또한, 전원회로와 저전압 초음파 에코신호 처리를 위한 아날로그 회로를 설계하고 시뮬레이션을 행하였다. 실험을 통하여, 설계된 측정기가 약 1mm 이내의 정확도를 가짐을 확인하였다.

초음파 유량계를 통하는 기체유동의 CFD 해석 (A CFD Analysis of Gas Flow through an Ultrasonic Meter)

  • 김재형;김희동;이호준;황상윤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.998-1003
    • /
    • 2003
  • Ultrasonic flow metering(UFM) technology is being received much attention from a variety of industrial fields to exactly measure the flow rate. The UFM has much advantage over other conventional flow meter systems, since it has no moving parts, and offers good accuracy and reliability without giving any disturbances to measure the flow rate, thereby not causing pressure losses in the flow fields. In the present study, 3-dimensional, unsteady, compressible Navier-Stokes equations are solved by a finite volume scheme, based upon the second order upwind scheme for spatial derivatives and the multi-stage Runge-Kutta integral method for time derivatives. In order to simulate multi-path ultrasonic flow meter, an excited pressure signal is applied to three different locations upstream, and the pressure signals are received at three different locations downstream. The mean flow velocities are calculated by the time difference between upstream and downstream propagating pressure signals. The obtained results show that the present CFD method simulates successfully ultrasonic meter gas flow and the mean velocity measured along the chord near the wall is considerably influenced by the boundary layers.

  • PDF

실제조건에서 기준 밀도계와 가스 분석기에 의한 밀도 측정 결과 비교 (Density Measurement Comparisons of Specific Gravity Meter and Gas Chromatography in the Field)

  • 이강진;허재영;하영철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.90-96
    • /
    • 1999
  • In contracts for sales of natural gas between sellers and buyers, it is not suncient to only measure a volumetric quantity of gas in flowing conditions in metering station. Therefore the measured volumetric quantity must be converted to that of reference conditions. The density of the natural gas required in such a calculation can be measured directly or estimated from the equation of sate or any other experimental methods. The specific gravity meter is the apparatus used to measure the density of fluids under the reference conditions and it can be widely used in industrial areas, especially in massive flow rate natural gas industry. This study has been carried out in an attempt to improve measurement accuracy of natural gas flow rate calculation, providing the adequate installation and proper operation conditions of specific gravity meter. The test results are 1) the density measurement errors in case of using methane and standard gas as calibration gases are smaller than using methane and nitrogen gas, 2) the periodical calibration to maintain accurate density measurements is essential, and 3) the specific gravity meter is sensitive to changes of environmental conditions, especially environmental temperature surrounding the specific gravity meter.

  • PDF

고조파 함유전원에 의한 유도형 적산전력량계의 실험적 특성해석 (Experimental Characteristic Analysis of Induction Watthour Meter by Input Source with Harmonics)

  • 장석명;이성호;박영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.58-60
    • /
    • 1998
  • The precise measurement of consumed power during the given time is very important in the energy management aspect. Up to days, induction watthour meter has been designed for use in the alternating circuits in which the voltage and current are essentially sinusoidal. The use of switching elements in power system causes the current or voltage involving harmonics. Therefore the registration error is caused by harmonics in the equipment for measuring power. This paper presents the registration error of the induction watthour meter in the presence of harmonic distortion. The accuracy of a watthour meter on loads in which the input source is not sinusoidal is investigated. And the effects of individual harmonic are reported by experiment.

  • PDF