• 제목/요약/키워드: Metallic prosthesis

검색결과 15건 처리시간 0.019초

Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating

  • Bacchi, Atais;Regalin, Alexandre;Bhering, Claudia Lopes Brilhante;Alessandretti, Rodrigo;Spazzin, Aloisio Oro
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.375-379
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at $10^6$ cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). RESULTS. The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). CONCLUSION. The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

관상동맥질환 치료를 위한 생체흡수형스텐트의 개발 동향 (The Developing Trend in Bioresorbable Stent for Treatment of Coronary Artery Disease)

  • 정경원;김태훈;나재운;박준규
    • 공업화학
    • /
    • 제29권5호
    • /
    • pp.497-502
    • /
    • 2018
  • 협심증, 심근경색과 같은 관상동맥 질환은 급속도로 증가하고 있다. 관상동맥 질환은 콜레스테롤과 칼슘과 같은 플라크들이 혈관벽에 흡착되어 발생한다. 심혈관 중재시술은 풍선 카테터와 금속스텐트를 이용하여 좁아진 관상동맥혈관을 확장시키는 비수술적 시술방법이다. 금속재질의 스텐트는 관상동맥질환에 의한 사망자를 감소시키는데 효과적이었지만 영구적으로 혈관에 금속재질 스텐트가 이식되어 있기 때문에 지속적인 염증과 후기 혈전증 등이 발생되었다. 따라서, 스텐트와 같은 영구적 보철물에 의한 합병증과 재협착 등을 해결하기 위한 생체 흡수성 혈관 지지체의 개발은 급속도로 증가되고 있다. 이 리뷰에서는 생체흡수형스텐트의 성공적인 개발을 위한 동향에 대해서 논하고자 한다.

Feasibility of Improving the Accuracy of Dose Calculation Using Hybrid Computed Tomography Images: A Phantom Study

  • Jeon, Hosang;Kim, Dong Woon;Joo, Ji Hyeon;Ki, Yongkan;Kim, Wontaek;Park, Dahl;Nam, Jiho;Kim, Dong Hyeon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권1호
    • /
    • pp.18-24
    • /
    • 2021
  • Purpose: Kilovoltage computed tomography (kV-CT) is essential for radiation treatment planning. However, kV-CT images are significantly distorted by artifacts when a metallic prosthesis is present in the patient's body. Thus, the accuracies of target delineation and treatment dose calculation are inevitably lowered. We evaluated the accuracy of the calculated doses using an image restoration method with hybrid CT, which was introduced in our previous study. Methods: A cylindrical phantom containing four metals, namely, silver, copper, tin, and tungsten, was scanned using kV-CT and megavoltage CT to produce hybrid CT images. We created six verification plans for three head and neck patients on kV-CT and hybrid CT images of the phantom and calculated their doses. The actual doses were measured with film patches during beam delivery using tomotherapy. We used the gamma evaluation method to compare dose distribution between kV-CT and hybrid CT with three gamma criteria, namely, 3%/3 mm, 2%/2 mm, and 1%/1 mm. Results: The gamma pass rates decreased as the gamma criteria were strengthened, and the pass rate of hybrid CT was higher than that of kV-CT in all cases. When the 1%/1 mm criterion was used, the difference in gamma pass rates between them was up to 13%p. Conclusions: According to our findings, we expect that the use of hybrid CT can be a suitable approach to avoid the effect of severe metal artifacts on the accuracy of dose calculation and contouring.

듀얼에너지 CT(kvp switching)의 임상 적용: MAR(Metal Artifact Reduction) 알고리즘의 적용 (Clinical Apply of Dual Energy CT (kVp switching) : A Novel Approach for MAR(Metal Artifact Reduction) Method)

  • 김명성;정종성;김명구
    • Journal of Radiation Protection and Research
    • /
    • 제36권2호
    • /
    • pp.79-85
    • /
    • 2011
  • 본 논고의 목적은 듀얼 에너지 시스템의 금속 인공물 감약 (MAR) 기법을 팬텀과 환자를 대상으로 적용하여보고 그 유용성에 대해서 알아보고자 한다. 사용한 장비는 GE사(社)의 750HD CT이고 AW 4.5 볼륨 share 4 워크스테이션에서 영상 분석을 하였다. 팬텀으로는 victoreen사(社)의 사람 모형 흉부팬텀을 사용하였고 사람 대상은 2010년 12월 20일부터 2011년 2월 10일까지 금속물질이 삽입된 환자 25명을 대상으로 목 부위와 복부 부위에 MAR 알고리즘을 적용하였다. 사용한 파라미터는 복부검사의 경우 GSI-4Body-Large 0.9 sec 40 mm이고 목 부위에서는 GSI-3Body-Medium 0.5 sec 40 mm를 선택하여 시행하였다. 영상시험은 국립암센터 CT영상실에서 기본적으로 시행하고 있는 프로토콜에 MAR 옵션을 적용하여 동일하게 시행하였다. 영상분석은 MAR기법을 적용한 영상과 적용하지 않은 영상에서 검은색 인공물과 줄무늬 인공물이 있는 부위에 관심부위 (ROI)를 설정한 후 hounsfield unit(HU)과 노이즈를 이용한 정량적 평가를 하였고 임상 경험이 풍부한 의사와 방사선사가 CT영상에 대한 평가를 하여 MAR 알고리즘에 대한 유용성을 비교하였다. 환자 대상 시험 결과 MAR 알고리즘을 적용함으로서 금속 인공물이 있는 부위에서의 검은색 인공물(금속이 있는 부위) 과 줄무늬 인공물이 있는 영상에서 HU의 p값이 각각 p=0.01과 p=0.04를 보였지만 금속 인공물의 영향에서 벗어난 부위에서의 노이즈는 오히려 증가하는 모습을 보였다(p=0.05). 그리고 그 외의 영상(금속이 있는 부위에서 1 cm 떨어진 단면 영상) 에서 검은색 인공물과 줄무늬 인공물 부위의 HU와 노이즈의 p값에 대해서는 통계적 유의성은 만족하지 못하였지만 대체적으로 MAR알고리즘을 적용함으로서 금속인공물 발생이 감약 되는 결과를 보였다. 결론적으로 금속 물질이 삽입된 환자의 경우에 MAR 알고리즘을 적용함으로서 조직의 선예도가 적용하지 안했을 때보다 증가하였고 검은색 인공물 발생 또한 개선되는 모습을 보였다.

컴퓨터단층촬영검사에서 고관절 삽입물에 의한 영상평가 (Image Evaluation by Metallic Hip Prosthesis in Computed Tomography Examination)

  • 민병인;임인철
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.281-288
    • /
    • 2022
  • 본 연구에서는 고관절에 금속삽입물(Metal implant)이 삽입되어 있는 환자를 대상으로 일반적인 CT검사(Before MAR) 영상과 MAR을 사용하여 얻어진(After MAR) 영상을 4개의 알고리즘(Soft, Standard, Detail, Bone)에 적용하여 Noise, SNR, CNR을 비교 분석하여 정량적 평가로 최적의 알고리즘을 알아보고자 하였다. 분석방법으로는 4개의 알고리즘으로 재구성한 영상에 이미지 분석과 영역 및 픽셀값을 계산할 수 있는 Image J 프로그램을 사용하였다. Noise, SNR, CNR을 구하기 위해 측정부위를 영상에서 금속삽입물이 가장 인접해 있는 Bone(궁둥뼈, ischium)을 지정하여 HU mean값과 HU SD값을 구하고 배경잡음(Background)은 주위 근육으로 하였다. 관심영역(region of interest, ROI)은 뼈의 크기를 감안하여 동일하게 15×15 mm로 지정하였으며 SNR과 CNR의 값은 주어진 식에 의거하여 산출하였다. 결과적으로 노이즈는 After MAR, Soft 알고리즘에서 노이즈가 가장 낮게 나타났으며, SNR, CNR은 Before MAR, Soft 알고리즘이 가장 높게 나타났다. 따라서 Soft 알고리즘이 고관절 금속삽입술 CT에 가장 적절한 알고리즘으로 판단된다.