Percutaneous Biliary Metallic Stent Insertion in Patients with Malignant Duodenobiliary Obstruction: Outcomes and Factors Influencing Biliary Stent Patency

  • Ji Hye Kwon;Dong Il Gwon;Jong Woo Kim;Hee Ho Chu;Jin Hyoung Kim;Gi-Young Ko;Hyun-Ki Yoon;Kyu-Bo Sung
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.695-706
    • /
    • 2020
  • Objective: To investigate the technical and clinical efficacy of the percutaneous insertion of a biliary metallic stent, and to identify the factors associated with biliary stent dysfunction in patients with malignant duodenobiliary obstruction. Materials and Methods: The medical records of 70 patients (39 men and 31 women; mean age, 63 years; range, 38-90 years) who were treated for malignant duodenobiliary obstruction at our institution between April 2007 and December 2018, were retrospectively reviewed. Variables found significant by univariate log-rank analysis (p < 0.2) were considered as suitable candidates for a multiple Cox's proportional hazard model. Results: The biliary stents were successfully placed in all 70 study patients. Biliary stent insertion with subsequent duodenal stent insertion was performed in 33 patients and duodenal stent insertion with subsequent biliary stent insertion was performed in the other 37 study subjects. The median patient survival and stent patency time were 107 days (95% confidence interval [CI], 78-135 days) and 270 days (95% CI, 95-444 days), respectively. Biliary stent dysfunction was observed in 24 (34.3%) cases. Multiple Cox's proportional hazard analysis revealed that the location of the distal biliary stent was the only independent factor affecting biliary stent patency (hazard ratio, 3.771; 95% CI, 1.157-12.283). The median biliary stent patency was significantly longer in patients in whom the distal end of the biliary stent was beyond the distal end of the duodenal stent (median, 327 days; 95% CI, 249-450 days), rather than within the duodenal stent (median, 170 days; 95% CI, 115-225 days). Conclusion: The percutaneous insertion of the biliary metallic stent appears to be a technically feasible, safe, and effective method of treating malignant duodenobiliary obstruction. In addition, a biliary stent system with a distal end located beyond the distal end of the duodenal stent will contribute towards longer stent patency in these patients.

Clinical Characteristics and Treatment Outcomes of Patients with Unresectable Cholangiocarcinoma in Thailand: Are there Differences Dependent on Stent Type?

  • Prachayakul, Varayu;Chaisayan, Suthasinee;Aswakul, Pitulak;Deesomsak, Morakod
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.529-532
    • /
    • 2013
  • Cholangiocarcinoma, though very rare in Western countries, is one of the commonest liver malignancies in Southeast Asia, especially in Thailand. More than half of the patients present with advanced stage disease. Given the poor treatment outcomes of adjuvant therapeutic options, many patients undergo only biliary drainage for palliative treatment. Clinical characteristics and treatment outcomes after biliary stenting were here analyzed for a total of 224 uresectable cholangiocarcinoma cases, 58.9% in men. The mean age was 61.5 years. Hilar involvement was the most common location. The patients underwent biliary drainage using plastic and metallic stents equally, early stent occlusion being encountered in 21.4% and 10.7%, respectively. The median survival time was 4.93 months for patients who received plastic and 5.87 months for patients who received metallic stents.

Optimal endoscopic drainage strategy for unresectable malignant hilar biliary obstruction

  • Itaru Naitoh;Tadahisa Inoue
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.135-142
    • /
    • 2023
  • Endoscopic biliary drainage strategies for managing unresectable malignant hilar biliary obstruction differ in terms of stent type, drainage area, and deployment method. However, the optimal endoscopic drainage strategy remains unclear. Uncovered self-expandable metal stents (SEMS) are the preferred type because of their higher functional success rate, longer time to recurrent biliary obstruction (RBO), and fewer cases of reintervention than plastic stents (PS). Other PS subtypes and covered SEMS, which feature a longer time to RBO than PS, can be removed during reintervention for RBO. Bilateral SEMS placement is associated with a longer time to RBO and a longer survival time than unilateral SEMS placement. Unilateral drainage is acceptable if a drainage volume of greater than 50% of the total liver volume can be achieved. In terms of deployment method, no differences were observed in clinical outcomes between side-by-side (SBS) and stent-in-stent deployment. Simultaneous SBS boasts a shorter procedure time and higher technical success rate than sequential SBS. This review of previous studies aimed to clarify the optimal endoscopic biliary drainage strategy for unresectable malignant hilar biliary obstruction.

Laser-cut-type versus braided-type covered self-expandable metallic stents for distal biliary obstruction caused by pancreatic carcinoma: a retrospective comparative cohort study

  • Koh Kitagawa;Akira Mitoro;Takahiro Ozutsumi;Masanori Furukawa;Yukihisa Fujinaga;Kenichiro Seki;Norihisa Nishimura;Yasuhiko Sawada;Kosuke Kaji;Hideto Kawaratani;Hiroaki Takaya;Kei Moriya;Tadashi Namisaki;Takemi Akahane;Hitoshi Yoshiji
    • Clinical Endoscopy
    • /
    • v.55 no.3
    • /
    • pp.434-442
    • /
    • 2022
  • Background/Aims: Covered self-expandable metallic stents (CMSs) are widely used for malignant distal biliary obstructions (MDBOs) caused by pancreatic carcinoma. This study compared the efficacy and safety of the laser-cut-type and braided-type CMSs. Methods: To palliate MDBOs caused by pancreatic carcinoma, the laser-cut-type CMSs was used from April 2014 to March 2017, and the braided-type CMSs was used from April 2017 to March 2019. The tested self-expandable metallic stents were equipped with different anti-migration systems. Results: In total, 47 patients received CMSs for MDBOs (24 laser-cut type, 23 braided-type). The time to recurrent biliary obstruction (TRBO) was significantly longer in the braided-type CMSs (p=0.0008), and the median time to stent dysfunction or patient death was 141 and 265 days in the laser-cut-type CMSs and braided-type CMSs, respectively (p=0.0023). Stent migration was the major cause of stent dysfunction in both groups, which occurred in 37.5% of the laser-cut-type CMSs and 13.0% of the braided-type CMSs. There were no differences in the survival duration between the groups. Conclusions: The TRBO was significantly longer for the braided-type CMSs with an anti-migration system than for the laser-cut-type. Stent migration tended to be less frequent with the braided-type CMSs than with the laser-cut-type CMSs.

Evaluation of the mechanical properties of current biliary selfexpandable metallic stents: axial and radial force, and axial force zero border

  • Wataru Yamagata;Toshio Fujisawa;Takashi Sasaki;Rei Ishibashi;Tomotaka Saito;Shuntaro Yoshida;Shizuka No;Kouta Inoue;Yousuke Nakai;Naoki Sasahira;Hiroyuki Isayama
    • Clinical Endoscopy
    • /
    • v.56 no.5
    • /
    • pp.633-649
    • /
    • 2023
  • Background/Aims: Mechanical properties (MPs) and axial and radial force (AF and RF) may influence the efficacy and complications of self-expandable metallic stent (SEMS) placement. We measured the MPs of various SEMSs and examined their influence on the SEMS clinical ability. Methods: We evaluated the MPs of 29 types of 10-mm SEMSs. RF was measured using a conventional measurement device. AF was measured using the conventional and new methods, and the correlation between the methods was evaluated. Results: A high correlation in AFs was observed, as measured by the new and conventional manual methods. AF and RF scatterplots divided the SEMSs into three subgroups according to structure: hook-and-cross-type (low AF and RF), cross-type (high AF and low RF), and laser-cut-type (intermediate AF and high RF). The hook-and-cross-type had the largest axial force zero border (>20°), followed by the laser-cut and cross types. Conclusions: MPs were related to stent structure. Hook-and-cross-type SEMSs had a low AF and high axial force zero border and were considered safest because they caused minimal stress on the biliary wall. However, the increase in RF must be overcome.

Biliary Self-Expandable Metal Stent Could Be Recommended as a First Treatment Modality for Immediate Refractory Post-Endoscopic Retrograde Cholangiopancreatography Bleeding

  • Sun Young Moon;Jun Heo;Min Kyu Jung;Chang Min Cho
    • Clinical Endoscopy
    • /
    • v.55 no.1
    • /
    • pp.128-135
    • /
    • 2022
  • Background/Aims: Recent reports suggest that the biliary self-expandable metallic stent (SEMS) is highly effective for maintaining hemostasis when endoscopic hemostasis fails in endoscopic retrograde cholangiopancreatography (ERCP)-related bleeding. We compared whether temporary SEMS offers better efficacy than angioembolization for refractory immediate ERCP-related bleeding. Methods: Patients who underwent SEMS placement or underwent angioembolization for bleeding control in refractory immediate ERCP-related bleeding were included in the retrospective analysis. We evaluated the hemostasis success rate, severity of bleeding, change in hemoglobin levels, amount of transfusion, and delay to the start of hemostasis. Results: A total of 27 patients with SEMS and 13 patients who underwent angioembolization were enrolled. More transfusions were needed in the angioembolization group (1.0±1.4 units vs. 2.5±2.0 units; p=0.034). SEMS failure was successfully rescued by angioembolization. The partially covered SEMS (n=23, 85.1%) was generally used, and the median stent-indwelling time was 4 days. The mean delay to the start of angioembolization was 95.2±142.9 (range, 9-491) min. Conclusions: Temporary SEMS had similar results to those of angioembolization (96.3% vs. 92.3%; p=0.588). Immediate SEMS insertion is considered a bridge treatment modality for immediate refractory ERCP-related bleeding. Angioembolization still has a role as rescue therapy when SEMS does not work effectively.

Prospective Multicenter Study of the Challenges Inherent in Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction

  • Yang, Min Jae;Kim, Jin Hong;Hwang, Jae Chul;Yoo, Byung Moo;Lee, Sang Hyub;Ryu, Ji Kon;Kim, Yong-Tae;Woo, Sang Myung;Lee, Woo Jin;Jeong, Seok;Lee, Don Haeng
    • Gut and Liver
    • /
    • v.12 no.6
    • /
    • pp.722-727
    • /
    • 2018
  • Background/Aims: Although endoscopic bilateral stent-instent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic re-intervention. This study aimed to evaluate the technical accessibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Methods: Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Results: Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases of technical success. Stent occlusion occurred in 63.2% of the patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months postoperatively, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Conclusions: Large cell-type stents for endoscopic bilateral stent-in-stent placement had acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.

Portal cavernography during endoscopic retrograde cholangiopancreatography: from bilhemia to hemobilia

  • Rawad A. Yared;Paraskevas Gkolfakis;Arnaud Lemmers;Vincent Huberty;Thierry Degrez;Jacques Deviere;Daniel Blero
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.521-526
    • /
    • 2023
  • Portobiliary fistulas are rare but may lead to life-threatening complications. Biliary plastic stent-induced portobiliary fistulas during endoscopic retrograde cholangiopancreatography have been described. Herein, we present a case of portal cavernography and recurrent hemobilia after endoscopic retrograde cholangiopancreatography in which a portobiliary fistula was detected in a patient with portal biliopathy. This likely indicates a change in clinical presentation (from bilhemia to hemobilia) after biliary drainage that was successfully treated by placement of a fully covered, self-expandable metallic stent.

Prophylactic endoscopic transpapillary gallbladder stenting to prevent acute cholecystitis induced after metallic stent placement for malignant biliary strictures: a retrospective study in Japan

  • Fumisato Kozakai;Yoshihide Kanno;Shinsuke Koshita;Takahisa Ogawa;Hiroaki Kusunose;Toshitaka Sakai;Keisuke Yonamine;Kazuaki Miyamoto;Haruka Okano;Yuto Matsuoka;Kento Hosokawa;Hidehito Sumiya;Kei Ito
    • Clinical Endoscopy
    • /
    • v.57 no.5
    • /
    • pp.647-655
    • /
    • 2024
  • Background/Aims: Endoscopic biliary drainage using self-expandable metallic stents (SEMSs) for malignant biliary strictures occasionally induces acute cholecystitis (AC). This study evaluated the efficacy of prophylactic gallbladder stents (GBS) during SEMS placement. Methods: Among 158 patients who underwent SEMS placement for malignant biliary strictures between January 2018 and March 2023, 30 patients who attempted to undergo prophylactic GBS placement before SEMS placement were included. Results: Technical success was achieved in 21 cases (70.0%). The mean diameter of the cystic duct was more significant in the successful cases (6.5 mm vs. 3.7 mm, p<0.05). Adverse events occurred for 7 patients (23.3%: acute pancreatitis in 7; non-obstructive cholangitis in 1; perforation of the cystic duct in 1 with an overlap), all of which improved with conservative treatment. No patients developed AC when the GBS placement was successful, whereas 25 of the 128 patients (19.5%) without a prophylactic GBS developed AC during the median follow-up period of 357 days (p=0.043). In the multivariable analysis, GBS placement was a significant factor in preventing AC (hazard ratio, 0.61; 95% confidence interval, 0.37-0.99; p=0.045). Conclusions: GBS may contribute to the prevention of AC after SEMS placement for malignant biliary strictures.

Efficacy of hemostasis by gastroduodenal covered metal stent placement for hemorrhagic duodenal stenosis due to pancreatobiliary cancer invasion: a retrospective study

  • Yasunari Sakamoto;Taku Sakamoto;Akihiro Ohba;Mitsuhito Sasaki;Shunsuke Kondo;Chigusa Morizane;Hideki Ueno;Yutaka Saito;Yasuaki Arai;Takuji Okusaka
    • Clinical Endoscopy
    • /
    • v.57 no.5
    • /
    • pp.628-636
    • /
    • 2024
  • Background/Aims: Advanced pancreatic and biliary tract cancers can invade the duodenum and cause duodenal hemorrhagic stenosis. This study aimed to evaluate the efficacy of covered self-expandable metal stents in the treatment of cancer-related duodenal hemorrhage with stenosis. Methods: Between January 2014 and December 2016, metal stents were placed in 51 patients with duodenal stenosis. Among these patients, a self-expandable covered metal stent was endoscopically placed in 10 patients with hemorrhagic duodenal stenosis caused by pancreatobiliary cancer progression. We retrospectively analyzed the therapeutic efficacy of the stents by evaluating the technical and clinical success rates based on successful stent placement, degree of oral intake, hemostasis, stent patency, and overall survival. Results: The technical and clinical success rates were 100%. All 10 patients achieved a gastric outlet obstruction scoring system score of three within two weeks after the procedure and had no recurrence of melena. The median stent patency duration and overall survival after stent placement were 52 days (range, 20-220 days) and 66.5 days (range, 31-220 days), respectively. Conclusions: Endoscopic placement of a covered metal stent for hemorrhagic duodenal stenosis associated with pancreatic or biliary tract cancer resulted in duodenal hemostasis, recanalization, and improved quality of life.