• Title/Summary/Keyword: Metal recovery

Search Result 541, Processing Time 0.028 seconds

Hydrometallurgical Processes for the Recovery of Tungsten from Ores and Secondary Resources (원광석 및 2차 자원으로부터 텅스텐 습식 제련 기술)

  • Ahn, Hyeong Hun;Lee, Man Seung
    • Resources Recycling
    • /
    • v.27 no.6
    • /
    • pp.3-10
    • /
    • 2018
  • Tungsten is a metal with high melting point and used as a raw material for the production of super alloys. Tungsten exists as $WO{_4}^{2-}$ in alkaline solution. As solution pH decreases, polymerization reaction of $WO{_4}^{2-}$ occurs to result in the precipitation of tungstic acid. The hydrometallurgical process for the recovery of tungsten from ores or secondary resources can be classified as acid and alkaline leaching. In selecting a process for the recovery of pure tungsten from secondary resources, the nature and concentration of impurities in the secondary resources and the manufactured tungsten materials should be considered.

Study on Heavy Metal Desorption and Recovery of the Carbon Foam used in Industrial Plating Wastewater Treatment as Adsorbent (산업도금폐수 처리에 사용된 탄소폼 흡착소재의 중금속 탈착 및 회수에 관한 연구)

  • Lee, Da-Young;Lee, Chang-Gu;Kim, Dae-Woon;Park, Sang-Hyen;Kweon, Ji-Hyang;Lee, Sang-Hyup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.11
    • /
    • pp.627-634
    • /
    • 2016
  • We investigated the characteristics of heavy metal desorption and recovery from carbon foam after plating wastewater treatment. The heavy metal desorption depends on solution chemistry because desorption occurred in HCl and $H_2SO_4 $ solution but did not occur in distilled water. Heavy metal desorption efficiency was increased using ultrasonication with desorption solution. The higher ultrasonic power and the longer reaction time improve efficiency. The copper plating rinse solution was treated reliably by carbon foam adsorbent during 200 bed volume. The adsorbed copper was dissolved using desorption solution and recovered by DC power supply. After copper recovery, the reuse efficiency of desorption solution was 84.2%.

Effect of Heat Input and Interpass Temperature on the Strength and Impact Toughness of Multipass Weld Metal in 570MPa Grade Steel (570MPa급 용접구조용강 다층 용접금속의 강도 및 충격인성에 미치는 입열 및 패스간 온도의 영향)

  • Byun, Ji-Chul;Bang, Kook-Soo;Chang, Woong-Sung;Park, Chul-Gyu;Chung, Woo-Hyun
    • Journal of Welding and Joining
    • /
    • v.24 no.1
    • /
    • pp.64-70
    • /
    • 2006
  • 570MPa grade weldable steels were gas metal arc welded with various heat inputs and interpass temperatures using flux cored wires. Effects of heat input and interpass temperature on the strength and impact toughness of weld metal were investigated in terms of microstructural change, recovery of alloying elements, and the amount of reheated weld metal. Increase of heat input and interpass temperature resulted in decrease of weld metal strength. This is because of the small amount of acicular ferrite, large columnar size and low recovery of alloying elements such as manganese and silicon. In addition to the microstructural change, weld metal toughness was also influenced by the deposition sequence. It increased with an increase of the amount of reheated weld metal.

A Study on Improvement of Valuable Metals Leaching and Distribution Characteristics on Waste PCBs(Printed Circuit Boards) by Using Pulverization Process (폐 PCBs의 미분쇄 공정 적용에 따른 유가금속 분포 특성 및 금속 침출 향상에 관한 연구)

  • Han, Young-Rip;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.24 no.2
    • /
    • pp.245-251
    • /
    • 2015
  • The main objective of this study is to recovery valuable metals with metal particle size distributions in waste cell phone PCBs(Printed Circuit Boards) by means of pulverization and nitric acid process. The particle size classifier also was evaluated by specific metal contents. The PCBs were pulverized by a fine pulverizer. The particle sizes were classified by 5 different sizes which were PcS1(0.2 mm below), PcS2(0.20~0.51 mm), PcS3(0.51~1.09 mm), PcS4(1.09~2.00 mm) and PcS5(2.00 mm above). Non-magnetic metals in the grinding particles were separated by a hand magnetic. And then, Cu, Co and Ni were separated by 3M nitric acid. Particle diameter of PCBs were 0.388~0.402 mm after the fine pulverizer. The sorting coefficient were 0.403~0.481. The highest metal content in PcS1. And the bigger particle diameter, the lower the valuable metals exist. The recovery rate of the valuable metals increases in smaller particle diameter with same leaching conditions. For further work, it could improve to recovery of the valuable metals effectively by means of individual treatment, multistage leaching and different leaching solvents.

The Recovery Performance of Co, Ni, and Cu Ions Using Zeolites Synthesized from Inorganic Solid Wastes (무기물계 폐기물로 합성한 제올라이트의 코발트, 니켈, 구리 이온의 회수 성능)

  • Lee, ChangHan
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.723-728
    • /
    • 2012
  • In this study, zeolites were synthesized by a fusion and a hydrothermal methods using a coal fly ash and a waste catalyst. The recovery performance of metal ions on the structure property of synthetic zeolites was evaluated as comparing the adsorption kinetics (Lagergen 2nd order model) and isotherm (Langmuir model) of $Co^{2+},\;Ni^{2+}$, and $Cu^{2+}$ ions. The synthetic zeolites (Z-C1 and Z-W5) were similarly assigned to XRD peaks in a reagent grade Na-A zeolite (Z-WK : $Na_{12}Al_{12}Si_{12}O_{48}\;27.4H_2O$). Adsorption rates of Z-W5 and Z-C1 were in the order of $Cu^{2+}\;>\;Co^{2+}\;>\;Ni^{2+}\;and\;Ni^{2+}\;>\;Cu^{2+}\;>\;Co^{2+}$, respectively. They had influenced upon structure properties of zeolite. Selectivities of metal ions and maximum equilibrium adsorption capacities, $q_{max}$, in Z-C1 and Z-W5 were in the order of $Ni^{2+}$ (127.9 mg/g) > $Cu^{2+}$ (94.7 mg/g) > $Co^{2+}$ (82.6 mg/g) and $Cu^{2+}$ (141.3 mg/g) > $Co^{2+}$ (122.2 mg/g) > $Ni^{2+}$ (87.6 mg/g), respectively. The results show that the synthetic zeolites, Z-C1 and Z-W5, are able to recover metal ions selectively in wastewater.

Parametric study for enhanced performance of Cu and Ni electrowinning

  • Kim, Joohyun;Kim, Han S.;Bae, Sungjun
    • Membrane and Water Treatment
    • /
    • v.10 no.3
    • /
    • pp.201-206
    • /
    • 2019
  • In this study, we performed an electrowinning process for effective removal of metals (Cu and Ni) in solution and their recovery as solid forms. A complete removal of Cu and Ni (1,000 mg/L) was observed during four times recycling test, indicating that our electrowinning system can ensure the efficient metal removal with high stability and durability. In addition, we investigated effect of operation parameters (i.e., concentration of boric acid only for Ni, variation of pH, concentration of electrolyte ($H_2SO_4$), and cell voltage) on the efficiency of metal removal (Cu and Ni) during the electrowinning. The addition of boric acid significantly enhanced removal efficiency of Ni as the concentration of boric acid increased up to 10 g/L. Compared to negligible pH effect (pH 1, 2, and 4) on the Cu removal, we observed the increase in removal efficiency of Ni as the pH increased from 1 to 4. The electrolyte concentration did not significantly influence the removal of Cu and Ni in this study. We also obtained great removal rates of Cu and Ni at 2.5 V and 4.0 V, which were much faster than those at lower voltages. Finally, almost 99% of each Cu and Ni (1,000 mg/L) was selectively removed from the mixture of metals by adjusting pH and addition of boric acid after the completion of Cu removal. The findings in this study can provide a fundamental knowledge about effect of important parameters on the efficiency of metal recovery during the electrowinning.

Effects of Heat Input and Preheat/interpass Temperature on Strength and Impact Toughness of Multipass Welded Low Alloy Steel Weld Metal (다층용접한 저합금 용접금속의 강도와 인성에 미치는 입열량 및 예열/패스간 온도의 영향)

  • Bang, Kook-soo;Jung, Ho-shin;Park, Chan
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.481-487
    • /
    • 2015
  • The effects of the heat input and preheat/interpass temperatures on the tensile strength and impact toughness of multipass welded weld metal were investigated and interpreted in terms of the recovery of the alloying elements and microstructure. Increases in both the heat input and preheat/interpass temperatures decreased the tensile strength of the weld metal. A lower recovery of alloying elements, especially Mn and Si, and smaller area fraction of acicular ferrite in the weld metal were observed in higher heat input welding, resulting in a lower tensile strength. In contrast, only a microstructure difference was observed at a higher preheat/interpass temperature. The impact toughness of the weld metal gradually increased with an increase in the heat input because of the lower tensile strength. However, it decreased again when the heat input was larger than 45 kJ/cm because of the much smaller area fraction of acicular ferrite. No effect of the preheat/interpass temperature on the impact toughness was observed. The formation of a weld metal heat-affect zone showed little effect on the impact toughness of the weld metal in this experiment.

A basic study on the recovery of Ni, Cu, Fe, Zn ions from wastewater with the spent catalyst (폐산화철촉매에 의한 폐수중 Ni, Cu, Fe, Zn이온 회수에 관한 기초연구)

  • Lee Hyo Sook;Oh Yeung Soon;Lee Woo Chul
    • Resources Recycling
    • /
    • v.13 no.2
    • /
    • pp.3-8
    • /
    • 2004
  • A basic study on the recovery of heavy metals such as Zn, Ni, Cu and Fe ions from wastewater was carried out with the spent iron oxide catalyst, which was used in the Styrene Monomer(SM) production company. The heavy metals could be recovered more than 98% with the spent iron oxide catalyst. The alkaline components of the spent catalyst could be precipitated the metal ions of the wastewater as metal hydroxides at the higher pH 10.6 in Ni, pH 8.0 in Cu, pH 6.5 in Fe, pH 8.5 in Zn. But the metal ions are adsorbed physically on the surface of the spent catalyst in the range of the pH of the metal hydroxides and pH 3.0, which is the isoelectric point of the iron oxide catalyst.

Leaching of copper from waste PCBs with electro-generated chlorine -Analysis of experimental factors on the leaching by the factorial design- (전해생성염소(電解生成鹽素)에 의한 폐인쇄회로기판(廢印刷回路基板)으로부터 구리 침출(浸出) -실험계획법(實驗計劃法) 적용(適用)에 의한 침출(浸出) 영향인자(影響因子)의 분석(分析)-)

  • Kim, Eun-Young;Lee, Jae-Chun;Kim, Min-Seuk;Jung, Jin-Ki;Yoo, Kyoung-Keun
    • Resources Recycling
    • /
    • v.17 no.6
    • /
    • pp.24-33
    • /
    • 2008
  • The leaching of Cu from waste PCBs was investigated with electro-generated chlorine as an oxidant. The leaching experiments were carried out according to the design of experiments to analyze quantitatively the effect of parameters on copper leaching. From the analysis of variance (ANOVA) it was suggested that the effective parameters were current density, temperature, concentration of HCl, and the interaction between the concentration of HCl and temperature. Especially, the effect of current density was analyzed to contribute to the interpretation of result for copper leaching up to 95.7%. A multiple regression model obtained from the analysis of effective parameters explained 99% of leaching results. From the model equation, it was found that the effect of HCl concentration on copper leaching increased with temperature.