• Title/Summary/Keyword: Metal primer

Search Result 67, Processing Time 0.021 seconds

Improvement of Protective Properties of Top Coatings Applied on Zinc-Rich Primer by 3-Aminopropyl-Triethoxysilan and 2-(Benzothialylthio) Succinic acid

  • Trinh, Anh Truc;To, Thi Xuan Hang;Vu, Ke Oanh;Nguyen, Tuan Dung
    • Corrosion Science and Technology
    • /
    • v.3 no.3
    • /
    • pp.107-111
    • /
    • 2004
  • Corrosion resistance of coating system consisting of zinc-rich primer (ZRP) and topcoat based on polyurethane resin with the presence of 3-aminopropyl-triethoxysilan (APS) and 2-(benzothialylthio) succinic acid (BSA) was studied by electrochemical impedance and wet adhesion. The interface metal/primer/topcoat was analyzed by scanning electronic microscopy. It was found that the presence of APS and BSA improved adhesion and barrier property of the topcoats.

THE EFFECT OF SUREACE TREATMENTS ON THE REBONDED RESIN-BONDED RETAINERS

  • Kim Sang-Pil;Kang Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.6
    • /
    • pp.590-596
    • /
    • 2002
  • The resin : metal interface is at the basis of most bonding failures in resin-bonded prosthesis. Although debonding has been a problem with adhesive fixed partial dentures, various dentists classify them as long-term restorations. The advantages of resin-bonded fixed partial dentures include minimal tooth reduction and the possibility of rebonding. if resin-bonded protheses can be easily rebounded, it is of clinical importance to know if the lutingagents rebond as well the second time as they did originally. Several retentive systems for resin-to-metal bonding have recommended. Treatments such as electrolytic etching and silicone coating, despite the good result of bond strength, have proved to be time-consuming and technique-sensitive. Therefore a simple and more reliable method is desirable. This study evaluated the effect of metal surface treatments on the rebond strength of panavia 21 cement to a nickel-chromium(Ni-Cr) alloy. The samples were received the following surface treatments : Group No.1 (control or served as the control) treatment with sandblasting with 50um aluminum oxide and ultrasonically cleaned for 10minutes in double-deionized water, Group No.2 were no surface treatments. Group No.3 were treated with metal primer. Group No.4 were treated with sandblasting as previously described, and then metal priming. From the analysis of the results, the following conclusions were drawn. 1. Sandblasting and metal priming appears to be an effective method for treatment of metal after accidental debonding. 2. Group without surface treatment had significantly lower bond strengths compared with other groups. 3. The combination of sandblasting and metal priming may not develop superior bonding strengths compared with other techniques that used the Ni-Cr alloys. 4. Combination of cohesive and adhesive failures were the most common type observed. The results support the use of sandblasting as a viable procedure when rebonding accidentally lost adhesive partial denture. We concluded that sandblasting and metal priming of metal surface before bonding could provide the adequate bond strength during rebonding of resin-bonded fixed partial denture.

A Study on the Tensile Strength between Light-cured Relining Resin and Metal Denture Base (광중합형 이장재와 금속의치상 간의 결합력에 관한 연구)

  • Park, In-Chae;Lee, Joon-Kyu;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.3
    • /
    • pp.211-220
    • /
    • 2000
  • The use of autopolymerizing-cured resin and light-cured resin for direct relining of complete and partial dentures has been popular. This investigation compared the adhesion of autopolymerizing-cured reline resin(Tokuso Rebase, Mild Rebaron) or light-cured reline resin(Mild Rebaron LC, Lighton-U) to metal base or resin base. Cylindrical samples were made from metal($Biosil^{(R)}$) or heat-cured resin(QC-20) and were prepared to produce a flat bonding surface. Cylindrical metal samples were roughened by scratch or by scratch and sandblast and were treated with primer(MR Bond) after scratch and sandblast. And then, liners were prossesed to the cylindrical metal or resin samples according to the manufacturer's recommendations so as to bond metal base or resin base. The specimens were tested in pure tension by using an Instron Univesal testing machine for the four direct reline resins. The results were as follows ; 1. In comparison with tensile bond strength of material relined on resin base or metal base, the case of resin base produced significantly higher tensile bond strength than the case of metal base. 2. Metal surface pretreatment or primer improved the tensile bond strength between the reline resin and the metal($Biosil^{(R)}$) base. 3. The tensile bond strength of Mild Rebaron LC relined on resin base or metal base were similar to those of the other reline resins.

  • PDF

A Study on the Tensile Strength between Light-cured Relining Resin and Metal Denture Base (광중합형 이장재와 금속의치상 간의 결합력에 관한 연구)

  • Park, In-Chae;Lee, Joon-Kyu;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.161-170
    • /
    • 2000
  • The use of autopolymerizing-cured resin and light-cured resin for direct relining of complete and partial dentures has been popular. This investigation compared the adhesion of autopolymerizing-cured reline resin(Tokuso Rebase, Mild Rebaron) or light-cured reline resin(Mild Rebaron LC, Lighton-U) to metal base or resin base. Cylindrical samples were made from metal($Biosil^{(R)}$) or heat-cured resin(QC-20) and were prepared to produce a flat bonding surface. Cylindrical metal samples were roughened by scratch or by scratch and sandblast and were treated with primer(MR Bond) after scratch and sandblast. And then, liners were prossesed to the cylindrical metal or resin samples according to the manufacturer's recomendations so as to bond metal base or resin base. The specimens were tested in pure tension by using an Instron Univasal testing machine for the four direct reline resins. The results were as follows ; 1. In comparison with tensile bond strength of material relined on resin base or metal base, the case of resin base produced significantly higher tensile bond strengths than the case of metal base. 2. Metal surface pretreatment or primer improved the tensile bond strength between the reline resin and the metal($Biosil^{(R)}$) base. 3. The tensile bond strengths of Mild Rebaron LC relined on resin base or metal base were similar to those of the other reline resins.

  • PDF

SHEAR BOND STRENGTH OF HEAT-CURED DENTURE BASE RESIN TO SURFACE TREATED CO-CR ALLOY WITH DIFFERENT METHODS (코발트-크롬 합금의 표면처리에 따른 열중합형 의치상용 레진과의 전단결합강도)

  • Lee, Sang-Hoon;Hwang, Sun-Hong;Moon, Hong-Seok;Lee, Keun-Woo;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.216-227
    • /
    • 2007
  • Statement of problem: For the long-term success of removable partial dentures, the bonding between metal framework and denture base resin is one of the important factors. To improve bonding between those, macro-mechanical retentive form that is included metal framework design has been generally used. However it has been known that sealing at the interface between metal framework and denture base resin is very weak, because this method uses mechanical bonding. Purpose: Many studies has been made to find a simple method which induces chemical bond, now various bonding system is applied to clinic. In this experiment, shear bond strengths of heat-cured denture base resin to the surface-treated Co-Cr alloy were measured before and after thermocycling. Chemically treated groups with Alloy $Primer^{TM}$, Super-Bond $C&B^{TM}$, and tribochemically treated group with $Rocatec^{TM}$ system were compared to the beadtreated control group. The data were analyzed with two-way ANOVA. Result: 1. Shear bond strength of bead-treated group is highest, and Alloy $Primer^{TM}$ treated group, Super-Bond $C&B^{TM}$ treated group, RocatecTM system treated group were followed. Statistically significant differences were found in each treated group(p<0.05). 2. Surface treatment and thermocycling affected shear bond strength(p<0.05), however there was no interaction between two factors(p>0.05). 3. Shear bond strengths of bead-treated group and Alloy $Primer^{TM}$ treated group showed no statistically significant difference before and after thermocycling(p>0.05), and those of Super-Bond $C&B^{TM}$ treated group and $Rocatec^{TM}$ system treated group showed statistically significant difference after thermocycling(p<0.05).

Effect of adhesive primers on bonding strength of heat cure denture base resin to cast titanium and cobalt-chromium alloy

  • Kim, Su-Sung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.41-46
    • /
    • 2009
  • STATEMENT OF PROBLEM. The poor chemical bonding of a denture base resin to cast titanium framework often introduces adhesive failure and increases microleakage. PURPOSE. This study evaluated the shear bond strengths of a heat cure denture base resin to commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy using two adhesive primers. MATERIAL AND MATHODS. Disks of commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy were cast. Specimens without the primer were also prepared and used as the controls. The shear bond strengths were measured on a screw-driven universal testing machine. RESULTS. The primers significantly(P < .05) improved the shear bond strengths of the heat cure resin to all metals. However, the specimens primed with the Alloy $primer^{(R)}$(MDP monomer) showed higher bond strength than those primed with the MR $bond^{(R)}$(MAC-10 monomer) on titanium. Only adhesive failure was observed at the metal-resin interface in the non-primed specimens, while the primed specimens showed mixed failure of adhesive and cohesive failure. CONCLUSIONS. The use of appropriate adhesive metal primers makes it possible not only to eliminate the need for surface preparation of the metal framework before applying the heat cure resins, but also reduce the need for retentive devices on the metal substructure. In particular, the Alloy $primer^{(R)}$, which contains the phosphoric acid monomer, MDP, might be clinically more acceptable for bonding a heat cure resin to titanium than a MR $bond^{(R)}$, which contains the carboxylic acid monomer, MAC-10.

Development for Finishing Method of Concrete Structures Applying Metal Spraying System (금속용사 시스템을 이용한 콘크리트 구조물의 마감공법 개발)

  • 이한승
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1225-1228
    • /
    • 2001
  • The purpose of this study is to develop for finishing method of concrete structures applying metal spraying system. In the experiments, the pull out tests were conducted using the specimen which was applied by various surface treatment of concrete substrate. As a result, it was confirmed that the adhesion strength of metal spray was effected by surface condition of concrete and the construction of primer or the coarse surface agent to the concrete substrate is very effective to the new finishing method of concrete for the metal spraying system.

  • PDF

A STUDY ON THE ADHESION OF A SOFT LINER CONTAINING 4-META TO THE BASE METAL ALLOY AND ITS VISCOELASTIC PROPERTY

  • Park Hyun-Joo;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.732-746
    • /
    • 2003
  • Statement of problem. Soft lining materials, also referred to as tissue conditioning materials, tissue heating materials, relining materials, soft liners or tissue conditioners, were first introduced to dentistry by a plastic manufacturer in 1959. Since the introduction of the materials to the dental field, their material properties have been continually improved through the effort of many researchers. Soft lining materials have become widely accepted, particularly by prosthodontists, because of their numerous clinical advantages and ease of manipulation. Unfortunately, few reports have been issued upon the topic of increasing the bond strength between the base metal alloy used in cast denture bases and PMMA soft liner modified with 4-META, nor upon the pattern of debonding and material change in wet environment like a intra oral situation. Purpose. The purposes of this study were comparing the bond strength between base metal alloy used for the cast denture bases and PMMA soft liner modified with 4-META, and describing the pattern of debonding and material property change in wet environment like the intraoral situation. Material and Methods. This study consisted of four experiments: 1. The in vitro measurement of shear bond strength of the adhesive soft liner. 2. The in vitro measurement of shear bond strength of the adhesive soft liner after 2 weeks of aging. 3. A comparison of debonding patterns. 4. An evaluation the Relation time of modified soft liner. The soft liner used in this study was commercially available as Coe-soft (GC America.IL.,USA), which is provided in forms of powder and liquid. This is a PMMA soft liner commonly used in dental clinics. The metal primer used in this study was 4-META containing primer packed in Meta fast denture base resin (Sun Medical Co., Osaka, Japan). The specimens were formed in a single lap joint desist which is useful for evaluating the apparent shear bond strength of adhesively bonded metal plate by tensile loading. Using the $20{\times}20mm$ transparent grid, percent area of adhesive soft liner remaining on the shear area was calculated to classify the debonding patterns. To evaluate the change of the initial flow of the modified adhesive soft liner, the gelation time was measured with an oscillating rheometer (Haake RS150W/ TC50, Haake Co., Germany). It was a stress control and parallel plate type with the diameter of 35mm. Conclusion. Within the conditions and limitations of this study, the following conclusions were drawn as follows. 1. There was significant increase of bond strength in the 5% 4-META, 10% 4-META containing groups and in the primer coated groups versus the control group(P<0.05). 2. After 2 weeks of aging, no significant increase in bond strength was found except for the group containing 10% 4-META (P<0.05). 3. The gelation times of the modified soft liner were 9.3 minutes for the 5% 4-META containing liner and 11.5 minutes for the 10% 4-META liner. 4. The debonding patterns of the 4-META containing group after 2 weeks of aging were similar to those of immediaely after preparation, but the debonding pattern of the primer group showed more adhesive failure after 2 weeks of aging.

COMPARATIVE STUDY OF SHEAR BOND STRENGTH BETWEEN CP-TI/CO-CR ALLOY AND COMPOSITE RESINS

  • Yoon, Se-Hee;Pae, Ahran;Lee, Seok-Hyung;Lee, Ho-Rim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.805-814
    • /
    • 2007
  • Statement of problem. Composite resin-veneered metal restorations can be used as an alternative to porcelain-fused-metal restorations. But, because of the relatively low bond strength of veneering composite to metal framework, various surface treatment methods have been introduced to improve the bond strength. Purpose. The object of this study was to compare the shear bond strength of different combinations of each of the two bonding systems and each of the two composite veneering resins to cp-Ti/Co-Cr alloy. Material and methods. Two resin bonding systems (metal conditioner containing MEPS monomer, tribochemical silicoating system) and two composite resins (Gradia, Sinfony) were tested on cp-Ti and Co-Cr alloy. Then, according to manufacturers' instructions, resin bonding systems and composite resins were applied. All test specimens were divided into four groups for each alloy; I) sandblast + Metal Primer II + Gradia (MG), II) sandblast + Metal Primer II + Sinfony (MS), III) Rocatec + Gradia (RG), IV) Rocatec + Sinfony (RS). The shear bond strength was determined using a universal testing machine and all data were statistically analyzed with Mann-Whitney test and Kruskal-Wallis test at the significance level of 0.05. Results. The mean (standard deviations) of shear bond strength according to the combinations of two bonding systems and two composite resins to cp-Ti arranged from 16.44 MPa to 17.07 MPa and the shear bond strength to Co-Cr alloy ranged from 16.26 MPa to 17.70 MPa. The result shows that the difference were not statistically significant. Conclusion. The shear bond strengths of composite resins to both cast cp-Ti and Co-Cr alloy were not significantly different between the metal conditioner and the tribochemical silicoating system. And no differences in bond strength were found between cp-Ti and Co-Cr alloy.

A STUDY ON THE SHEAR BOND STRENGTH BETWEEN NONPRECIOUS METAL SURFACE AND RESIN CEMENT ACCORDING TO THE VARIOUS SURFACE TREATMENT METHODS (다양한 표면 처리 방법에 따른 비귀금속과 접착성 레진간의 결합력에 관한 연구)

  • Ryu Young-Ryeol;Lim Ju-Hwan;Cho In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.2
    • /
    • pp.157-170
    • /
    • 2001
  • The bond strength is the most important factor in establishing long-term success of resin-retained fixed prostheses. So, various surface treatment methods have been introduced to improve the bond strength of metal surface and bonding resin till now This study was performed to compare the effect of silicoating with that of metal primer and analyze the correlation between treatment time of sandblasting and the bond strength, so that meant to find more effective surface treatment method that could enhance the bond strength of resin-retained fixed prostheses. The surfaces of all specimens made of $Verabond^{(R)}$ alloys were air abraded with $250{\mu}m\;Al_2O_3$ according to treatment time of sandblasting and they were subdivided to be treated with only sandblasting(S group), silicoating following sandblasting(SS group) and metal primer application after sandblasting(SM group). Then pairs of metal specimens (${\phi}10mm{\times}h\;2mm,\;{\phi}6{\times}h\;2mm$) were bonded with Super bond $C&B^{(R)}$. The specimens were stored in $38^{\circ}C$ water for 48 hours and shear bond strength was measured using the universal testing machine. The results were as follows, 1. In the comparison of shear bond strength according to treatment time of sandblasting, bond strength was increased in the order of 0', 15', 30', 45', 60' group. 0' group had significantly lower value than any other, while 0', 15' group were significantly different with 30', 45', 60' group(p<0.05). 2. In the comparison of shear bond strength according surface treatment methods, bond strength was increased in the order of S group. SS group and SM group. S group was significantly different with SS group and SM group(p<0.05). 3. Observing the mode of bond failure. 0', 15' group showed only adhesive failure, and 30', 45', 60' group did mostly adhesive & cohesive failure in S group. In SS group and SM group, all other groups except 0', 15' group showed mostly cohesive failure. From the above results, it is considered that sandblasting should be treated for more than 30 seconds, and metal primer be more effective and available clinically than silicoater system which is complicate, technique-sensitive and time-consuming method, when nonprecious metal surface is planning be treated with in order enhance the bond strength of resin-retained fixed prostheses.

  • PDF