• Title/Summary/Keyword: Metal plating wastewater

Search Result 39, Processing Time 0.019 seconds

Study on Heavy Metal Desorption and Recovery of the Carbon Foam used in Industrial Plating Wastewater Treatment as Adsorbent (산업도금폐수 처리에 사용된 탄소폼 흡착소재의 중금속 탈착 및 회수에 관한 연구)

  • Lee, Da-Young;Lee, Chang-Gu;Kim, Dae-Woon;Park, Sang-Hyen;Kweon, Ji-Hyang;Lee, Sang-Hyup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.11
    • /
    • pp.627-634
    • /
    • 2016
  • We investigated the characteristics of heavy metal desorption and recovery from carbon foam after plating wastewater treatment. The heavy metal desorption depends on solution chemistry because desorption occurred in HCl and $H_2SO_4 $ solution but did not occur in distilled water. Heavy metal desorption efficiency was increased using ultrasonication with desorption solution. The higher ultrasonic power and the longer reaction time improve efficiency. The copper plating rinse solution was treated reliably by carbon foam adsorbent during 200 bed volume. The adsorbed copper was dissolved using desorption solution and recovered by DC power supply. After copper recovery, the reuse efficiency of desorption solution was 84.2%.

Evaluation of Metal Oxide Semiconductor and Electrochemical Gas Sensor Array Characterization for Measuring Wastewater Odor (폐수의 악취측정을 위한 금속산화물 반도체 및 전기화학식 가스센서 어레이 특성 평가)

  • Yim, Bongbeen;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • This study aimed to evaluate the characterization of a metal oxide semiconductor and electrochemical gas sensor array for measuring wastewater odor. The sensitivity of all gas sensors observed in sampling method by stripping was 6.7 to 20.6 times higher than that by no stripping, except sensor D (electrochemical gas sensor). The average reduction ratio of sensor signal as a function of initial dilution rate of wastewater was in the order of food plant > food waste reutilization facility > plating plant. The sensitivity of gas sensors was dependent on both the type of wastewater and the dilution rate. The sensor signals observed by the gas sensor array were correlated with the dilution factor (OU) calculated by the air dilution sensory test with several wastewater ($r^2=0.920{\sim}0.997$), except the sensor signals of sensor D measured in the plating plant wastewater. It seems likely that the gas sensor array plays a role in the evaluation of odor in wastewater and is useful tool for on-site odor monitoring in the wastewater facilities.

Preparation of Water Soluble Chitosan Blendmers and Their Application to Removal of Heavy Metal ions from Wastewater

  • Seo, Sang-Bong;Toshio Kajiuchi;Kim, Dae-In;Lee, Soon-Hong;Kim, Hak-Kil
    • Macromolecular Research
    • /
    • v.10 no.2
    • /
    • pp.103-107
    • /
    • 2002
  • High purity water soluble chitosans (WsCs) were employed as a flocculant to remove heavy metal ions from wastewater of industrial plating wastewater treatment complex. Their weight average molecular weights and polydispersities were 272,000~620,000 g/mol and 1.4~1.9 range, respectively and were readily soluble in water in the pH range of 3~11. Heavy metal ions such as chromium, iron and copper were removed well by WsCs. When WsCs was blended with either sodium N, N-diethyldithiocarbamate trihydrate (SDDC$_{T}$) or sodium salicylate (SSc), the removal efficiency was further increased primarily due to the excess amount of hydrophilic sulfonic and carboxylic groups. Especially, in the case of WsCs-SSc the remaining chromium and copper concentrations were 0.1 mg/L and 9.5 mg/L, which are 1/15 and 1/3 compared with that of pure WsCs, respectively. The former is within the acceptable limit, but the latter is not. Therefore, the effective copper flocculant remains to be studied.d.

Treatment Characteristics of Plating Wastewater Containing Freecyanide, Cyanide Complexes and Heavy Metals (II) - Effect of Aldehyde Compounds and Polysulfide - (도금폐수내 유리시안과 착염시안 및 중금속의 처리특성 (II) - aldehyde와 polysulfide첨가에 따른 영향 -)

  • Jung, Yeon-Hoon;Lee, Soo-Koo
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.4
    • /
    • pp.687-690
    • /
    • 2010
  • The objective of this study is to investigate the effect of aldehyde compounds and ploysulfide as accelerating agents on removal of heavy metals and CN in plating wastewater. As a results of the experiments, the removal efficiency of cyanide using the formaldehyde type of aldehydes was the highest at pH 9. Next types were sodium formaldehyde bisulfite addut> paraldehyde> paraformaldehyde. Also, optimum pH and dosage for treating the residual heavy metals by using polysulfide were pH 9 and 30 mg/L, respectively. The removal efficiencies of cyanide, chromium, zinc and copper were above 96.7% at optimum condition.

Technology Trends of Metal Recovery from Wastewater (폐수(廢水) 중(中) 유가금속(有價金屬) 회수기술(回收技術) 동향(動向))

  • Hwang, Young-Gil;Kil, Sang-Cheol;Kim, Jong-Heon
    • Resources Recycling
    • /
    • v.22 no.3
    • /
    • pp.91-99
    • /
    • 2013
  • Steel industry which has been accomplishes the base of our country economy, automobile and electronic industry are taking charge of the role, whose electroplating is important. Large amount of wastewater and various metal salts, including hazardous materials was generated from the electroplating pre-treatment, plating, washing and post-plating. Currently, the general wastewater follows in the environmental law and neutralization after controlling, sludge where the various metal is mixed reclaims below multiple regulative and trust it is controlling. The sludge which includes the gas price metal reclaims in the field and trust it controls. a reclamation price of land it is insufficient but and the control expense holds plentifully and it loses the gas price metal which is valuable. Consequently, The research regarding to recover a gas price metal actively from this waste water, it is advanced. A new method to recover valuable metals from electroplating wastewater synthesis of metal sulfides using topical methods utilizing iron oxidizing bacteria, reagent of sulfides and solvent extraction using an organic solvent, such as the development of the law to recover these metals and metal sulfides of wastewater using selective recovery have been studied. By using these wastewater treatment method under frequency above 95%, it has been obtained the valuable metal from the wastewater, where the metal ion of Fe, Cu, Zn and Ni complexes was mixed. As we discuss the wastewater, which has been discharged from electroplating process, it is important and will be applied to the resources of metal in the urban mine.

A study on the recovery of chromium from metal-plating wastewater with spent catalyst (폐산화철촉매에 의한 도금폐수중 크롬이온 회수에 관한 기초연구)

  • Lee Hyo Sook;Oh Yeung Soon;Lee Woo Chul
    • Resources Recycling
    • /
    • v.13 no.2
    • /
    • pp.9-15
    • /
    • 2004
  • A large tons of spent iron oxide catalyst come from the Styrene Monomer(SM) production company. It is caused to pollute the land and underground water due to the high alkali contents in the catalyst by burying them in the landfill. In order to recycle the spent catalyst, a basic study on the recovery of chromium ion from metal plating wastewater with the spent catalyst was carried out. The iron oxide catalyst adsorbed physically $Cr^{+6}$ in the lower pH 3.0, that is the isoelectric point of the spent catalyst. It was found that the iron oxide catalyst reduced the $Cr^{+6}$ into Cr+3 by the oxidation of ferrous ion into ferric ion on the surface of catalyst, and precipitated as $Cr(OH)_3$ in the higher than pH 3.0. The $Cr^{+6}$ was recovered 2.0∼2.3g/L catalyst in the range of pH 0.5∼2.0, but it was recovered 1.5 g/L catalyst at pH 3.0 of wastewater. The recovery of Cr was increased as the higher concentration in the continuous process, but the flowrates were nearly affected on the Cr recovery.

The Treatment of Cyanide by Electro-Oxidation (전기산화를 이용한 Cyanide의 처리)

  • Kim, Hong-Tae;Lee, Young-Do;Kim, Kyu-Choul;Kim, Hak-Seok;Chun, Bong-Jun;Ku, Bong-Hun
    • Journal of Environmental Science International
    • /
    • v.17 no.3
    • /
    • pp.335-342
    • /
    • 2008
  • This study based on electro-coagulation & oxidation reaction is applied to wastewater treatment. Electro-oxidation reaction is used to remove cyanide(CN) which is contained in plating wastewater. Cyanide is transferred by gases such as $NH_3,\;NO_x,\;CO_2$. Analysis result and removal efficiency of Cyanide which is contained in heavy metal wastewater of plating plant, are shown as following paragraph. In electrode arrangement experiment, removal efficiency of carbon electrode(-)/STS316L electrode(+) arrangement method is superior to carbon electrode(-)/carbon electrode(+) arrangement method. Removal efficiencies of cyanide in different HRT such as 30 min, 45 min, 60 min, 75 min and 90 min are 85.5%, 93.1%, 98.0%, 98.7% and 99.4% respectively in carbon electrode(-)/STS316L electrode(+) arrangement method. Finally we can estimate the critical point at HRT of 60 min which the variation of removal efficiency is decreased and HRT to obtain removal efficiency of less than 1 mg/LCN is minimum 90 min.

Coagulation of the Metal-Plating Wastewater using Coal Fly Ash (비산회를 이용한 도금폐수의 응집처리)

  • 연익준;김광렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.37-45
    • /
    • 2002
  • The Purpose of this study is to reduce environmental problems caused by landfill of bituminous coal fly ash emitted from the power plant and to reuse it. First of all, we experimented that Al and Si elements were extracted from fly ash and investigated that extracted Al and Si elements night use a coagulant. The extraction was carried out under various conditions ; concentration of the extraction solution, calcination temperature and calcination time. As the results, it was found that the optimum conditions of the extraction of Al and Si elements from fly ash were as follows, concentration of NaOH was 5N for both of them, calcination temperature was $700^{\circ}C$ and $600^{\circ}C$ and calcination time was 1hr and 1.5hr, respectively The extracted solution was used as a coagulant to treat the diluted metal-plating solutions which contained Pb and Cu, respectively. As the result of treatment on the diluted Pb-plating solution with 315NTU, the removal efficiency of turbidity was more than 90%, and the removal efficiency of Pb was about 80%. As for treatment of the non-turbid diluted Cu-plating solution, the removal efficiency of Cu was about 98%.

Heavy Metal Ion Adsorption Characteristics of Cuttle fish Born (갑오징어뼈를 이용한 중금속의 흡착 특성)

  • 방명렬;현근우;이광춘;박정희;김영진
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.1
    • /
    • pp.54-61
    • /
    • 2000
  • We studied the adsorption characteristics on the treatment process of heavy metal wastewater by using cuttle fish bones powder. When adding the 0.25% cuttle fish born powder in the heavy metal solution, $Fe^{3+}$ and $Pb^{2+}$ were high removed than other heavy metals as above 95%. In the solution which was adjusted to pH 5, 7 and 9, there was not observed the difference thing on the heavy metal removal rate. At test using plating wastewater treatment, adding 1%, 1.5% and 2% of the cuttle fish born powder, the heavy metal removal rate were as follows; Zn 12.5 - 37.5%, Mn 18.0 - 62.2%, Cd 36.8 -93.0%, Cu 51.4 - 97.4%, Cr 70.8 - 99.1%, Fe 87.2 - 99.3% and Pb 92.8 - 99.9%. When adding the 0.15% cuttle fish born powder and mixing for 20 minutes, the solution was happened the adsorption equability. Applied this results to the Freundlich's iso-thermal equation, we found the cuttle fish born's probability as a good adsorbent.

  • PDF

Optimization of Electrolysis Using Sacrificial Electrode for the Treatment of Electroless Nickel Plating Wastewater (희생전극을 이용한 무전해 니켈 도금 폐수의 전기분해처리 최적화)

  • Kim, Young-Shin;Jeon, Byeong-Han;Cho, Soon-Haing
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.4
    • /
    • pp.204-209
    • /
    • 2015
  • The effluent limit of nickel from electroplating wastewater has been strengthened from 5 mg/L to 3 mg/L from 2014. However, currently applied treatment process for nickel plating wastewater is unable to meet the effluent limit, most of the treatment concept conducted by treatment plant is dilution with other metal bearing wastewater. This can cause very significant impact to the environment of nickel contamination. With this connection, the feasibility test has been conducted with the use of electrolysis by using sacrificial electrodes. Experiments were conducted in synthetic and electroless nickel plating wastewater. Optimal condition of current density, pH were derived from the synthetic wastewater. It was found that the removal efficiency of nickel exceeded 94% at the operation condition of at pH 9 and the current density of $1{\sim}2mA/cm^2$. At this conditions, the iron sludge was generated very low amount. However, it was unsuccessful to meet the effluent limit by applying these treatment conditions to the real electroplating wastewater. This can be explained due to the matrix effect of other metals and anions contained real electroplating wastewater. From the result of further study, the optimal conditions for the real wastewater treatment were found out to be at pH 9, current density $6{\sim}7mA/cm^2$, for 5 minutes of operating time. At these conditions, 88% removal of nickel was achieved, which results the residual nickel concentration was below 3 mg/L.