• 제목/요약/키워드: Metal on metal total hip arthroplasty

검색결과 5건 처리시간 0.018초

Pseudotumor and Subsequent Implant Loosening as a Complication of Revision Total Hip Arthroplasty with Ceramic-on-Metal Bearing: A Case Report

  • Naik, Lokesh Gudda;Shon, Won Yong;Clarke, I.C.;Moon, Jun-Gyu;Mukund, Piyush;Kim, Sang-Min
    • Hip & pelvis
    • /
    • 제30권4호
    • /
    • pp.276-281
    • /
    • 2018
  • Pseudotumors are not uncommon complications after total hip arthroplasty (THA) and may occur due to differences in bearing surfaces of the head and the liner ranging from soft to hard articulation. The most common causes of pseudotumors are foreign-body reaction, hypersensitivity and wear debris. The spectrum of pseudotumor presentation following THA varies greatly-from completely asymptomatic to clear implant failure. We report a case of pseudo-tumor formation with acetabular cup aseptic loosening after revision ceramic-on-metal hip arthroplasty. The patient described herein underwent pseudotumor excision and re-revision complex arthroplasty using a trabecular metal shell and buttress with ceramic-on-polyethylene THA. Surgeons should be aware of the possibility of a pseudotumor when dealing with revisions to help prevent rapid progression of cup loosening and implant failure, and should intervene early to avoid complex arthroplasty procedures.

Recent updates for biomaterials used in total hip arthroplasty

  • Hu, Chang Yong;Yoon, Taek-Rim
    • 생체재료학회지
    • /
    • 제22권4호
    • /
    • pp.259-270
    • /
    • 2018
  • Background: Total hip arthroplasty (THA) is probably one of the most successful surgical interventions performed in medicine. Through the revolution of hip arthroplasty by principles of low friction arthroplasty was introduced by Sir John Charnley in 1960s. Thereafter, new bearing materials, fixation methods, and new designs has been improved. The main concern regarding failure of THA has been the biological response to particulate polyethylene debris generated by conventional metal on polyethylene bearing surfaces leading to osteolysis and aseptic loosening of the prosthesis. To resolve these problems, the materials of the modern THA were developed since then. Methods: A literature search strategy was conducted using various search terms in PUBMED. The highest quality articles that met the inclusion criteria and best answered the topics of focus of this review were selected. Key search terms included 'total hip arthroplasty', 'biomaterials', 'stainless steel', 'cobalt-chromium', 'titanium', 'polyethylene', and 'ceramic'. Results: The initial search retrieved 6921 articles. Thirty-two articles were selected and used in the review. Conclusion: This article introduces biomaterials used in THA and discusses various bearing materials in currentclinical use in THA as well as the newer biomaterials which may even further decrease wear and improve THA survivorship.

A FEM Analysis for Acetabular Component with Negative Poisson's Ratio in Total Hip Arthroplasty

  • 최재봉
    • 전산구조공학
    • /
    • 제8권4호
    • /
    • pp.17-23
    • /
    • 1995
  • Based on the present FEM study for negative Poisson's-ratio UHMWPE, the following conclusions seem expected. 1) Negative Poisson's-ratio UHMWPE transfers less stresses to the subchondral or peripheral iliac bone, compared to the conventional UHMWPE with Poission's-ratio. 2) Negative Poisson's-ratio cup reduces stresses in UHMWPE cup itself as well as metal backing, and subchondral bone. 3) The reduction in periacetabular mechanical stresses would significantly reduce the rate of fatigue failure and consequently reduce the incidence of aseptic loosening of the cup due to wear or bone resorption.

  • PDF

PET/CT에서의 고관절 삽입물에 의한 인공물과 Metal Artifact Reduction Algorithm의 유용성에 대한 고찰 (The Study of Usefulness of Metal Artifact Reduction Algorithm and Artifacts Caused by Metallic Hip Prosthesis on PET/CT)

  • 박민수;함준철;조용인;강천구;박훈희;임한상;이창호
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.35-43
    • /
    • 2012
  • CT를 기반으로 감쇠 보정이 시행되는 PET/CT 검사에서는 금속 삽입물에 의한 선속 경화 현상 (Beam Hardening Artifact)으로 인공물이 발생 된다. 이는 인접한 부위의 과대 혹은 과소 평가를 유발하는 감쇠 보정으로 인해 $^{18}F$-FDG의 섭취 변화를 가져오며 영상의 질과 비뇨 생식기 질환의 진단능을 저하시킨다. 따라서 본 연구에서는 PET/CT 영상의 질 향상을 위한 금속 인공물 저감 (Metal Artifact Reduction, MAR) algorithm 재구성방법의 유용성을 평가하고자 한다. 인공 고관절 삽입물에 대한 인공물을 평가하기 위해 SPECT/PET Phantom에 고관절 삽입물을 고정 하여 PET/CT를 진행했다. W/O MAR algorithm 영상과 MAR algorithm 영상에서 CT상에 나타나는 Bright streak, Dark streak, Metal과 Background의 영역에서의 표준화 섭취 계수(Standardized Uptake Value)의 변화를 분석하였다. 또한 본원에 내원한 고관절 전치환술을 시행한 15명의 환자에게서 W/O MAR algorithm과 MAR algorithm, 비 감쇠 보정 영상을 비교 평가하였다. W/O MAR algorithm 영상에서 SUV는 Bright streak 영역에서는 $0.98{\pm}0.48$ g/ml, Dark streak 영역에서는 $0.88{\pm}0.02$ g/ml, Metal 영역에는 $0.24{\pm}0.16$ g/ml, Background 영역은 $0.91{\pm}0.18$ g/ml로 측정되었다. 하지만 MAR algorithm 영상에서는 Bright streak 영역에서는 $0.88{\pm}0.49$ g/ml, Dark streak 영역은 $0.63{\pm}0.21$ g/ml, Metal 영역에서는 $0.06{\pm}0.07$ g/ml, Background는 $0.90{\pm}0.02$ g/ml로 측정되었다. MAR algorithm 적용 시 SUV가 평균적으로 감소 하였으며, W/O MAR algorithm 영상에서는 Bright streak영역에서 Background 보다 높게 측정되어 false positive uptake로 나타났으나 MAR algorithm 영상에서는 Background와 비슷한 농도와 SUV가 나타났고, false positive uptake가 관찰되지 않았다. 따라서 MAR algorithm을 적용하여 인공 고관절 삽입물 주변 조직의 과대 혹은 과소 감쇠 보정으로 인한 섭취의 증가를 줄일 수 있었다. 하지만 Dark streak 영역에서의 SUV 저하를 줄이기 위한 방안은 더욱 많은 연구가 이뤄져야 할 것이다. 고관절 삽입 인공물로 인해 발생하는 Bright streak 영역에서의 false positive uptake를 감소시키고 이와 인접해 있는 비뇨 생식기 질환에 W/O MAR algorithm과 MAR algorithm, 비 감쇠 보정 영상이 동시에 제공된다면 더욱 진단능을 향상 시킬 수 있으리라 생각된다.

  • PDF

메가볼트 에너지 전산화 단층 촬영을 이용한 치료계획의 유용성 연구 (A Study of Usefulness for Megavoltage Computed Tomography on the Radiation Treatment Planning)

  • 조정희;김주호;강현수;이종석;유병규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권4호
    • /
    • pp.369-378
    • /
    • 2010
  • 고밀도 물질의 존재에 따른 킬로볼트 및 메가볼트 에너지 전산화 단층촬영(kilovoltage & megavoltagecomputed tomography, KVCT & MVCT) 영상의 아티팩트 차이를 비교하기 위하여 Cheese 팬텀을 사용하여 KVCT와 MVCT로 얻은 영상자료를 통해 밀도변화에 따른 HU값의 변화를 비교하였다. 또한 각 영상의 sinogram 자료를 치료계획 장비에 입력 후 시행하여 치료선량에 변화 여부와 조사면내 계산값과 실측값간의 차이를 r값으로 비교분석하였으며 이에 대한 실제 환자에 적용하여 임상적용에 관한 유용성을 검정하였다. KVCT와 MVCT간에 HU값 차이는 KVCT의 밀도 3.0에서 역치를 보여 변화가 없었으나 MVCT에서는 밀도 5.0 이상도 구별하는 것을 관찰할 수 있었다. 각 방법의 Sinogram 정보를 통해 일반팬텀으로 계산한 결과 r 값이 허용오차인 1보다 낮은 비율은 KVCT와 MVCT에서 각각 94.92%, 93.87%로 큰 차이를 보이지 않았으나 고밀도팬텀을 이용해 아티팩트가 존재하는 자료를 이용한 선량계산의 결과는 KVCT와 MVCT에서 각각 88.25%와 93.77%로 다소 차이를 보였다. MVCT 이용 시에는 아티팩트가 거의 나타나지 않았고 고밀도 물질의 윤곽을 정확히 알 수 있었으며 상대적으로 선량계산의 정확성이 향상되어 척추궁 절제술 후 인공보형물이 삽입된 척추종양과 같이 결정장기와 종양이 인접한 환자에 있어서도 MVCT영상자료를 이용하여 선량 계산 시 보다 정확한 치료계획이 가능하리라 사료된다.