• Title/Summary/Keyword: Metal heater

Search Result 84, Processing Time 0.026 seconds

Fabrication of catalytic combustible gas sensor for hydrocarbon gas detection (탄화수소계 가스 감지용 접촉연소식 가스센서의 제조)

  • Park, Hyo-Derk;Lee, Jae-Suk;Kim, Kun-Nyun;Park, Jong-Wan;Shin, Sang-Mo
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.3
    • /
    • pp.9-15
    • /
    • 1994
  • Catalytic combustible gas sensors were fabricated by using ${\gamma}-Al_{2}O_{3}$ with large surface area and noble metal catalysts. The optimum conditions for ${\gamma}-Al_{2}O_{3}$ fabrication were investigated by DT/TGA and XRD analyses and it was found that fabricated ${\gamma}-Al_{2}O_{3}$ had superior value as surface area of $215.5m^{2}/g$. Gas sensors were manufactured and tested to inflammable gases by using Pt coil as a heater and temperature sensing part, fine ${\gamma}-Al_{2}O_{3}$ powder as a bead material and Pt, Pd noble metal powder as a catalyst. From the results, fabricated sensor showed good sensitivity to LPG and LNG of 20mV/l000ppm, 6.5mV/l000ppm respectively.

  • PDF

An Experimental Study on the Manufacturing Method and Performance of Planar Thick Film Heaters for Electric Vehicle Heating (전기자동차의 난방용 면상 후막히터의 제조방법과 성능에 관한 실험적 연구)

  • Chae-Yeol Lee;Jong-Han Im;Jae-Wook Lee;Sang-Hee Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.3
    • /
    • pp.685-692
    • /
    • 2024
  • Currently used heating elements are metal and non-metal heating elements, including various types of heaters, and resistance line heating elements have a problem of decreasing thermal efficiency over time, so to solve this problem, a planar heating element using high-purity carbon materials and oxidation-resistant inorganic compounds was applied. Through the manufacture of planar heating elements using CNT, ruthenium composite materials, and ruthenium oxide, physicochemical performance and capacity were increased, and instantaneous responsiveness was increased. Through thick film technology applicable to various base bodies, fine patterns were formed by the screening method in consideration of the fact that the performance of the heat source depends on the viscosity and pattern shape. The heating element was manufactured by thick film printing technology by mixing ruthenium oxide, CNT, Ag, etc. The characteristics of each paste were analyzed through viscosity measurement, and STS 430 was used as a base. Surface temperature and efficiency were measured by testing heaters manufactured for small wind tunnels and real-vehicle experiments. The surface temperature decreased as the air volume increased, and the optimal system boundary was found to be about 200 mm. Among the currently used heating elements, this paper manufactured a planar heating element using thick film technology to find out the relationship between air volume and temperature, and to study the surface temperature.

Gas-Flow Sensor using Optical Fiber Bragg Grating(FBG)

  • Shim, Joon-Hwan;Cho, Seok-Je;Yu, Yung-Ho;Sohn, Kyung-Rak
    • Journal of Navigation and Port Research
    • /
    • v.32 no.9
    • /
    • pp.717-722
    • /
    • 2008
  • We have proposed and demonstrated an gas-flow sensor using optical fiber bragg grating(FEG). The flow sensor has no electronics and no mechanical parts in its sensing part and the structure is th11s simple and immune to electromagnetic interference(EMI). The FEG sensor was consisted qf the sensing element and a coil heater. The metal coil was used to supply the current to the FEG. While some currents supply to the coil, the refractive index of the FEG under the coil is changed and thus the wavelength shift of fiber optic sensor was induced In this work, the wavelength shift according to flow-rate was experimentally studied and was used to evaluate the gas flow-rate in a gas tube. As a result, it was possible to measure the flow-rate in a linear range from 5 to $20{\ell}/min$ with a resolution of approximately $1{\ell}/min$ at the applied currents of 100 mA and 120 mA. The measured sensitivities were $15.3\;pm/\ell/min$ for 100 mA and $20.2\;pm/\ell/min$ for 120 mA.

Gas Sensing Characteristics and Doping Effect of $MoO_3$ Thin Films prepared by RF magnetron sputtering (RF magnetron sputtering법으로 제조한 $MoO_3$ 박막의 가스 감지 특성 및 첨가물의 영향)

  • Hwang, Jong-Taek;Jang, Gun-Eik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.460-463
    • /
    • 2002
  • $MoO_3$ thin films were deposited on electrode and heater screen-printed alumina substrates in $O_2$ atmosphere by RF reactive sputtering using Molybdenum metal target. The deposition was performed at $300^{\circ}C$ with 350W of a forward power in an $Ar-O_2$ atmosphere. The working pressure was maintained at $3{\times}10^{-2}mtorr$ and all deposited films were annealed at $500^{\circ}C$ for 5hours. To investigate gas sensing characteristics of the addition doped $MoO_3$ thin film, Co, Ni and Pt were used as adding dopants. The sensing properties were investigated in tenn of gas concentration under exposure of reducing gases such as $H_2$, $NH_3$ and CO at optimum working temperature. Co-doped $MoO_3$ thin film shows the maximum 46.8% of sensitivity in $NH_3$ and Ni-doped $MoO_3$ thin film exhibits 49.7% of sensitivity in $H_2$.

  • PDF

A Phenomenological Review on the Decision on the Cause of Ignition of Electric Iron (전기다리미의 발화원인 판정에 관한 현상학적 고찰)

  • Mun, Yong-Soo;Kong, Ha-Sung;Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.1
    • /
    • pp.43-49
    • /
    • 2009
  • This study set three kinds of situation and observed the various states such as carbonization by experimenting damages by fire of electric iron. The results of this study are as follows: The fire did not occurred when the unpowered iron over mattress and cotton shirts was com busted completely by external flame because the temperature of surface of soleplate and mattress did not reach the minimum ignition energy and when the powered electric iron over mattress and cotton shirts was left for an hour with its temperature dial set to high because the temperature of combustibles did not reach the minimum ignition energy. The fire occurred when the electric iron in which the outer box, bi-metal switch, and temperature fuse were removed over mattress and cotton shirts was powered by through heater terminal, and then the electric iron, mattress, and cotton shirts were combusted by the fallen combustibles because the temperature of combustibles reached to the minimum ignition energy with the help of active transfer of heat.

Design and fabrication of SOI $1\times2$ Asymmetric Optical Switch by Thermo-optic Effect (열광학 효과를 이용한 SOI $1\times24$ 비대칭 광스위치 설계 및 제작)

  • 박종대;서동수;박재만
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.10
    • /
    • pp.51-56
    • /
    • 2004
  • We propose and fabricate an 1${\times}$2 asymmetric optical switch by TOE using SOI wafer based on silicon which has very large TOE figure and it is a good material for optical devices. SOI wafer consists of 3 layers; upper Si layer for device(waveguide;core, n=3.5), buried oxide layer for insulator(clad, n=1.5) and Si substrate layer. We designed 1${\times}$2 asymmetric y-branched single mode optical waveguide switch by BPM simulation and metal heater by heat transfer simulation. Fabricated switch shows about 3.5 watts of power consumption and over 20dB of crosstalk between output channels.

An Experimental Investigation on the Operating Characteristics of a Reversible Loop Heat Pipe (가역 루프 히트파이프의 작동특성에 관한 실험적 연구)

  • Kim Bong-Hun;Choi Joon-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.231-239
    • /
    • 2006
  • An experimental investigation of a Reversible Loop Heat Pipe (RLHP) was conducted to determine the operating limits and performance characteristics as functions of the thermophysical parameters, the heat input, and the cooling intensity. Variations in both temperature and heat transport capacity were measured and analyzed in order to accurately evaluate the transient operating characteristics. In addition, the maximum heat transport as a function of the mean evaporator temperature, the ratio of heat transport to heater input power as a function of the mean evaporator temperature, and the overall thermal resistance as a function of the overall heat transport capacity were examined as well. Results indicated that the cooling intensity played an important role on the operating characteristics and performance limitation. The maximum heat transports corresponding to cooling intensity $72W/^{\circ}C$ and $290W/^{\circ}C$ were 446 W and 924 W, respectively. Also, observation of the startup characteristics indicated that the mean evaporator temperature should be maintained between $40^{\circ}C$ and $60^{\circ}C$, and overall thermal resistance were measured as $0.02^{\circ}C/W$.

Dehydriding Performance in a Depleted Uranium Bed (감손 우라늄 베드 수소 탈장 성능)

  • KOO, DAESEO;KIM, YEANJIN;YUN, SEI-HUN;CHUNG, HONGSUK
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.1
    • /
    • pp.22-28
    • /
    • 2016
  • It is necessary to store and supply hydrogen isotopes for Tokamak operation. A storage and delivery system (SDS) is used for storing hydrogen isotopes as a metal hydride form. We designed and fabricated a depleted uranium (DU) bed to store hydrogen isotopes. The rapid storage of hydrogen isotopes is very important not only for safety reasons but also for the economic design and operation of the SDS. The delivery rate at the desorption temperatures without the operation of a dry pump was analyzed in comparison with that with the operation of the dry pump. The effect of the initial desorption temperatures on the dehydriding of the DU without the operation of the dry pump was measured. The effect of the initial desorption temperatures on the dehydriding of DU with the operation of the dry pump was also measured and analyzed. The primary pressure on the desorption temperatures without the operation of the dry pump was analyzed in comparison with that with the operation of the dry pump. The temperature gradient of the coil heater and the primary vessel was also analyzed. Our results will be used to develop pilot scale hydrogen isotope processes. It was confirmed that dehydriding of a medium-scale DU bed has enabled without the operation of the dry pump.

Design and Performance Test of Large-Area Susceptor for the Improvement of Temperature Uniformity (온도 균일도 향상을 위한 대면적 서셉터의 설계 및 성능 시험)

  • Yang, Hac Jin;Kim, Seong Kun;Cho, Jung Kun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3714-3721
    • /
    • 2015
  • Although sheath-type heating line is generally used for susceptor heater, performance deterioration problems in temperature uniformity occurs in the case of large scale and high temperature condition. We developed new design and prototype of the susceptor using sheet metal to provide performance improvement in temperature uniformity. Temperature uniformity below 1.4% in the surface temperature condition of $450^{\circ}C$ was verified in the susceptor prototype. Also we developed Kernel regression algorithm to estimate measured temperature using temperature learning data. The reliability of the measured temperature uniformity was confirmed by comparative analysis between predicted data and measured data.

Experimental Quality Characteristics for Water Removal in Inner Flushing Oil in Process Piping of Offshore Plant (해양플랜트 프로세스 배관 내경 플러싱 오일속에서 수분제거를 위한 실험적 품질 특성)

  • Park, Chang-Soo;Sung, Ki-Young;Han, Seong Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.797-805
    • /
    • 2019
  • An important problem of offshore plant process piping is equipment accidents due to the removal of fine metal debris and foreign substances in the pipes that deliver fluids such as hydraulic oil, lubricating oil and thermal oil. Temporary flushing equipment to remove debris uses fluid equipment of centrifugal pump and gear pump to prevent equipment accident of offshore platform. The equipment manufacturer requires the shipyard to have a cleanliness rating inside the pipe to meet the international standards ISO4406 and NAS1638 quality levels to prevent damage to the equipment sold. The quality of the internal flushing of pipes conforms to the regulations suggested by the equipment manufacturer. In this paper, three types of electric heater capacity, which is a method of evaporating and removing water inside a pipe during an oil flushing process, were compared. In addition, the study was conducted to remove the flushing oil in the pipe and to improve oil quality.