• 제목/요약/키워드: Metal Loss

검색결과 818건 처리시간 0.027초

오일공급 방향에 따른 타원형 베어링 손실 및 온도 특성 (Effect of Oil Supply Direction on Power Loss and Bearing Temperature of Elliptical Bearing)

  • 방경보;최용훈;조용주
    • Tribology and Lubricants
    • /
    • 제34권4호
    • /
    • pp.138-145
    • /
    • 2018
  • Elliptical bearings are widely used for large steam turbines owing to their excellent load carrying capacity and good dynamic stability. Power loss in bearings is an extremely important parameter, especially for high turbine capacities. Optimization of operation conditions and design variables such as bearing clearance and bearing length can reduce the power loss in elliptical bearings. Although changes in the oil supply method have served to increase the efficiency of the tilting pad journal bearing, it has not explicitly improved elliptical bearings. In this study, we verify the static characteristics of an elliptical bearing by changing the direction of oil supply. We evaluate the bearing power loss and bearing metal temperature, and compare the bearing performance and reliability in different test cases. The direction of oil supply is $90^{\circ}$ (9 o'clock) and $270^{\circ}$ (3 o'clock) when the rotor rotates in a counterclockwise direction. We use an elliptical bearing with an inner diameter and active length of 220.30 and 110.00 mm, respectively. Bearing power loss and bearing metal temperatures are measured and evaluated by rotor rotational speed, oil flow rate, and bearing load. The results reveal a 20 reduction in the power loss when the direction of oil supply is 90. Furthermore, the oil film on the upper part of the bearing has a high temperature when the direction of oil supply is $90^{\circ}$. In contrast, when the direction of oil supply is $270^{\circ}$, the oil film on the upper part of the bearing is relatively cold.

컴퓨터를 이용한 회주철의 탕구방안 설계에 관한 연구 (A study on the computed aided gating design in gray cast iron)

  • 최정길;김동옥
    • 한국주조공학회지
    • /
    • 제6권1호
    • /
    • pp.27-35
    • /
    • 1986
  • The gating design of gray cast iron was programmed in a Personal computer. By this program, casting test was done. The results obtained are as follows. 1. Gating design that can calculate the velocity of metal flow and size in each gate section by knowing the loss coefficient caused by friction loss and bend loss was programmed. 2. In the test casting, the gating ratio was changed into 1.1:1.3:1, 1:2:2, 1:4:4. And sound casting, free of sand washing defect, was obtained at the velocity of 35.5cm/sec in ingate.

  • PDF

낙동강 수계 표층 퇴적물의 중금속 분포와 오염도 (Distribution and Pollution of Heavy metals in Surface sediments from Nakdong River)

  • 김신;김주언;이권철;이규열;전혜린;유재정;이인정;안정민
    • 한국환경과학회지
    • /
    • 제24권8호
    • /
    • pp.969-980
    • /
    • 2015
  • In order to certificate the distribution and pollution of heavy metal of surface sediments in Nakdong River were collected and analyzed for grain size, water content, ignition loss and heavy metal content. Surface sediments mainly composed of sand(avg. 94.6%) and water content and ignition loss were 20.46%, 1.53% on average. Grain size were relatively fine and organic matter content were relatively high in the Hoichun and Sunakdonggang. Most of heavy metal content(Zn > Cr > Pb > Ni > Cu > Hg) in the Deokcheongang and Sunakdonggang were higher than the other streams. The Igeo were non polluted(less than 0) in all streams and the EF were relatively high in the small stream and PLI were non polluted(less than 1). In addition, organic matter, heavy metal content and pollution were highly correlation with grain size. Surface sediments in study area, heavy metal pollution of the Sunakdonggang were relatively high compared to the other stream but these results were not serious pollution that exceed the sediment pollution evaluation standard of river and lake in Korea and pollution levels adversely affected the majority of benthos were not.

치과용 자석부착장치의 물리적, 생물학적 특성에 관한 연구 (A STUDY ON THE PHYSICAL PROPERTIES AND BIOLOGICAL CHARACTERISTICS OF DENTAL MAGNETIC ATTACHMENTS)

  • 임용식;김영수;김창회;김용호
    • 대한치과보철학회지
    • /
    • 제37권1호
    • /
    • pp.1-22
    • /
    • 1999
  • In order to investigate various physical and biological properties of dental magnetic attachments studies on retentive characteristics, corrosion properties, cytotoxicity of different magnetic systems for dental applications were done. For the study of retentive characteristics changes of retentive force by increasing air gap, wear properties of various attachment systems and loss of magnetic force by heat treatment were measured. Forte study of corrosion property of magnet covering metal electrochemical corrosion was done in artificial saliva and 0.9% NaCl solution between $-1,000mV_{SCE}\;and\;+1,000mV_{SCE}$. Anodic polarization curves are obtained about 6 types of samples and 2 types of solution. Corroded surfaces were examined with metallurgical microscope, scanning electron microscope and surface profilometer. For the study of cytotoxicity of magnetic attachment and its field cell growth and agar overlay test were done. The results of this study were as follows. 1. In Magnetic attachments using closed circuit retentive force at zero air gap was greater than magnets using open circuit, but decrease of retentive force by increasing air gap was also greater than open systems. 2. After 40,000 cycles of wear test all mechanical attachment resulted in varing degree of retention loss but in magnetic attachments no loss of retentive force was observed. 3. The magnetic attachment using Neodymium magnet showed early loss of retentive force about $200^{\circ}C$ but attachment using Samarium magnet showed some resistance to heat treatment and complete retention loss was observed about $500^{\circ}C$. The keeper was not influenced by heat treatment in retention. 4. In electrochemical corrosion test Dyna magnetic attachment covering metal showed the highiest corrosion resistance and Shiner magnet covering metal showed the least corrosion resistance and examination of corroded surface with metallurgical microscope, scanning electron micro-scope and surface profilometer also showed same results with anodic polarization corves. 5. The result of cell culture tests on the magnet covered with metal showed least recognizable cytotoxicity.

  • PDF

Metal Powder를 이용한 PWM 컨버터 입력단 AG리액터 개발 (A Development of AC Reactor for PWM Converter using the Metal Powder)

  • 이근호;하경호;김영균;이지영;홍정표;이진기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.619-621
    • /
    • 2002
  • In this paper, AC reactor for PWM converter using the metal powder is introduced. Metal powder AC reactor was developed to substitute conventional iron core typed AC reactor in the PWM converter application. The characteristics of the metal powder AC reactor are analyzed and tested. A new reactor has reduced switching noise and loss.

  • PDF

Compressive Properties of Amorphous Metal Fiber Reinforced Concrete Exposed to high Temperature

  • Lee, Jun-Cheol;Kim, Wha-Jung;Lee, Chang-Joon
    • 한국건축시공학회지
    • /
    • 제12권2호
    • /
    • pp.183-193
    • /
    • 2012
  • Compressive property of high strength concrete with amorphous metal fibers subject to high temperature has been investigated. The measure of this investigation includes explosive spalling, weight loss, residual compressive strength, strain at peak stress, elastic modulus, and residual energy absorption capacity after exposure to $400^{\circ}C$, $600^{\circ}C$and $800^{\circ}C$. In addition to the amorphous metal fiber, two other types of fibers (polypropylene fiber and hooked-end steel fiber) were also included in this investigation for comparison. The experimental program was conducted with high strength concrete using several combinations of the fiber types. The testing result shows that the concrete with amorphous metal fibers plus polypropylene fibers shows a superior behavior than those using other combination or single fiber type ingredient.

금속 섬유 필터층을 이용한 미세 분진 집진 성능 관찰 (Examination of Dust Trapping Mechanism in a Metal Fiber Filter-bed)

  • 이경미;조영민
    • 한국대기환경학회지
    • /
    • 제20권3호
    • /
    • pp.361-369
    • /
    • 2004
  • A metal fiber bed has seldom been applied to the practical filtration process despite its excellent mechanical and chemical stability. The filter-bed used in this work was highly porous with open structure, of which apparent porosity was 80 ∼ 90%. Although pressure loss across the filter-bed was very low, separation efficiency was found to be quite high. This paper focuses on the basic filtration mechanisms of a metal filter-bed and a thin ceramic filter from fly ash for reference. The experimental parameters were face velocity, dust loading and porosity of filter-bed. Pressure drop increased with increasing face velocity and dust feeding load for both filters. It also showed that dust particles deposited in the deep flow path, finally resulting in clogging the pore channels. It thereby indicates that the dominating mechanism of the metal filter-bed would be depth filtration. Meanwhile, the thin fly ash composite filters trapped the aerated dust mainly on the surface of the filter medium, so that the instantaneously formed dust layer might cause a steep increase of pressure drop across the filtration system.

금속 DPF를 이용한 입자상물질의 저감효율에 관한 연구 (PM Reduction Efficiency using Metal Type DPF)

  • 나완용
    • 한국자동차공학회논문집
    • /
    • 제21권5호
    • /
    • pp.176-180
    • /
    • 2013
  • After-treatment apparatus ceramic DPF (diesel particulate filter) have been applied to reduce harmful particulate matters(PM) among emissions from diesel engines so far, but they are easy to be fragile and weak in thermal shock. This research aims to investigate a metal type filter which is superior in mechanical strength and heat conduction rate and is beneficial economically in manufacturing. Basic performance of metal DPF such asloading test, temperature gradient test, thermal shock test, heat resistant test and back pressure was carried out. And then their experimental data provided key informations in designing and manufacturing such as detailed structures of metal mesh filter. Also diesel engine and vehicle of 2957cc displacement was tested under lug-down 3 mode and CVS-75 mode. PM reduction efficiency was 54.5% using metal DPF without loss of performance and fuel consumption.

알루미늄 발포금속의 유효열전도도와 침투율의 측정 (Measurement of effective thermal conductivity and permeability on aluminum foam metal)

  • 백진욱;강병하;김서영;현재민
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.185-192
    • /
    • 1999
  • Effective thermal conductivities and pressure-drop-related properties of aluminum foam metals have been measured. The effects of porosity and cell size in the aluminum foam metal are investigated in detail. The porosity of the foam metal, considered in the present study, varies from 0.89 to 0.96 and the cell size from 0.65㎜ to 2.5㎜. The effective thermal conductivity is evaluated by comparing the temperature gradient of the foam metal with that of the thermal conductivity-known material. The pressure drop in the foam metal is measured by a highly precise electric manometer while air is flowing through the aluminum foam metal in the channel. The results obtained indicate that the effective thermal conductivities are found to be increased with a decrease in the porosity while the effective thermal conductivities ire little affected by the cell size at a fixed porosity. However, the pressure drop is strongly affected by the cell size as well as the porosity. It is seen that the pressure drop is increased as the cell size becomes smaller, as expected. The minimum pressure drop is obtained in the porosity 0.94 at a fixed cell size. A new correlation of the pressure drop is proposed based on the permeability and Ergun's coefficient for the aluminum foam metal.

  • PDF