• 제목/요약/키워드: Metal Fiber Burner

Search Result 23, Processing Time 0.042 seconds

Combustion Characteristics of Premixed Burner for Domestic Condensing Gas Boiler Using Metal Fiber and Throttle Body (Metal Fiber와 Throttle Body를 적용한 가정용 응축보일러용 예혼합 버너의 연소특성)

  • Lee, Pil Hyong;Hwang, Sang Soon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.4
    • /
    • pp.249-256
    • /
    • 2017
  • Premixed combustion has many advantages, including low CO and NOx emissions and a small combustor volume. These characteristics allow a compact design and wide application to condensing boilers with high thermal efficiencies. This study focused on the combustion characteristics in a premixed combustion burner using metal fiber and a throttle body. The results showed that a blue flame was found to be very stable at a heating load of 6,250-25,000 kcal/h when implementing the proper metal fiber, baffle plate, and throttle body. The NOx emission was less than 11 ppm under an equivalence ratio of 0.724-0.795, and the CO emission was less than 50 ppm under the same equivalence ratio. The thermal efficiency, which is a very important index when condensing a gas boiler, was observed to be above 96.3% under an equivalence ratio of 0.750.

Combustion Characteristics of HCNG Burner System with Tail Gas Addition (HCNG용 버너시스템에서 Tail Gas 첨가 시 연소특성)

  • Han, J.O.;Lee, J.S.;Kim, H.T.;Kim, S.M.;Lee, Y.C.;Kim, Y.C.;Hong, S.H.
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.2
    • /
    • pp.36-39
    • /
    • 2015
  • The combustion characteristics of metal fiber burner fueled natural gas with tail gas produced from reforming process were analyzed on the point of flame stability and excess air conditions. Also, it was analyzed the effect of energy efficiency improvement due to decrease the fuel input in reforming system by using residue gases. As a results, it was confirmed that tail gas including hydrogen, CO and $CO_2$ could be directly injected without any change of air control system in natural gas burner and also energy efficiency was increased up to 30% maintained stable combustion.

Combustion Characteristic and Stability of Flat Premixed Ceramic Burner with Different Porous Baffle Plates (평판 예혼합 세라믹 버너의 분포판 변화에 따른 연소화염특성과 안정성 분석)

  • Lee, Jae-Young;Lee, Pil-Hyong;Park, Chang-Soo;Park, Bong-Il;Hwang, Sang-Soon
    • Journal of the Korean Society of Combustion
    • /
    • v.14 no.4
    • /
    • pp.7-16
    • /
    • 2009
  • Porous metal plates (Metal fiber, muti-hole metal plate) using mainly in surface burner are known to have a corrosion and durability problem under high temperature condition. In this study, premixed flat flame with perforated ceramic tile of more durable cordierite material was examined with respect to combustion stability and emission. The flat premixed ceramic burner consists of perforated ceramic tile and various type of baffle plates to form stable surface flame. The results show that most stable flat flame is generated using baffle plate with open ratio of 0.193. In downward flat flame mode which is widely used in condensing boiler, CO is measured below 50ppm from equivalence ratio 0.755 to 0.765 and $NO_X$ is measured below 12ppm from equivalence ratio 0.75 to 0.79. It is also found that the range of blue flame in flame stability curve becomes wider with increasing heat capacity.

  • PDF

Heat Transfer Characteristics of 0.5 t/h Class Non-Furnace Boiler with a Metal Fiber Burner (금속섬유 버너를 채택한 0.5 t/h 급 무연소실 보일러의 열전달 특성)

  • Ahn, Joon;Kim, Jong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.215-220
    • /
    • 2011
  • A 0.5 t/h class non-furnace boiler has been developed with the aim of achieving a high efficiency and compactness. A metal fiber burner has been adopted so that a stable flame can be obtained. The tube banks are installed downstream of the burner. Bare tubes are used upstream, while finned tubes are installed downstream. The heat-transfer characteristics of the non-furnace boiler have been studies on the basis of the results of the numerical simulation as well as those of the experiment. Important design parameters such as the bulk temperature along the streamwise direction and the temperature of the fin tips have been evaluated using the CFD results and compared with the experimental data and the empirical correlations typically used for the design of the boiler.

The Characteristics of NOx Emission for Premixed Combustion and Flame Rapid Cooling of MFB (메탈파이버 버너의 예혼합 연소 및 화염급냉에 따른 NOx 배출 특성)

  • Kim, Hyouck-Ju;Park, Byung-Sik;Kim, Jong-Jin;Jeong, Hae-Seung
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.172-179
    • /
    • 2001
  • Experimental studies have been carried out to find out the characteristics of the heat transfer, combustion emission and noise in the boilers without any extra firing zone for complete combustion of fuel. For the experiments a burner of premixed type and some heat exchangers were designed and manufactured. Also test facilities including a data acquisition system and various measuring devices were set up in order to measure automatically the various temperatures and flow rates of water and combustion gas. Various experiments were performed to find out the heat transfer characteristics as well as combustion emission and noise. In general, the burner which has uniform holes in the burner nozzle plate generates big combustion noise . whistling. The noise reduction method is discussed in this study. Many experimental data such as noise level, the amount of pollutant emission and heat transfer rate for different combination of heat exchangers are given as comparison bases for numerical studies.

  • PDF

Conservation of a Bronze Incense Burner from Chungung-dong, Hanam (하남시 춘궁동 출토 청동현향로(靑銅懸香爐)의 제작기술과 보존처리)

  • Jeong, Subin;Park, Haksoo
    • Conservation Science in Museum
    • /
    • v.16
    • /
    • pp.32-45
    • /
    • 2015
  • The bronze incense burner, discovered in Chungung-dong, Hanam, Gyeonggi-do in 1971, is a hanging incense burner dating from the Goryeo period. The incense burner was covered with a thick layer of clay. The object was in a severely deteriorated state, affected by bronze disease which resulted in extensive corrosion. Numerous cracks were present across its surface, and some parts had been broken off. To preserve and display the bronze incense burner in a stable condition, deposits of foreign material were removed from the surface, and the weakened metal was strengthened. Cracked and broken areas were reinforced using woven glass fiber, followed by the application of epoxy resin to restore the shape. To investigate the method of production, a chemical analysis was performed, and the microstructure was examined. The chemical analysis revealed that the body of the incense burner as well as the ear, loop, lid and the knob were cast in a ternary alloy of Cu-Sn-Pb. Moreover, copper nails with high copper content were used to securely join the ear to the body of the incense burner. The microstructure was mainly α-phase, and non-intermetallic inclusions composed of Cu and S were detected.

The Flow analysis and the Flame structure of Turbulent Premixed Flat Burner (난류예혼합 플랫버너의 유동해석과 화염구조)

  • Kim, Hun-Ju;Yun, Bong-Seok;Heo, Su-Bin;Park, Jae-Min;Lee, Do-Hyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.397-405
    • /
    • 2011
  • Hydrogen energy, as part of eco-friendly alternative energy, is made mostly through reforming of fossil fuels. The turbulent premixed combustion type of metal-fiber flat burner which is recently used in industry was tested in this paper. We measured the mean temperature distributions, CO, HC, $CO_2$ and $O_2$ concentrations to observe the flame structure and flame stability in some kind of experimental conditions. And also PIV and several flow analysis methods were compared to establish the numerical analysis model. The results of this paper will be the basis of the burner design of steam reformer.

A Study on the Temperature Characteristics and Flame Stabilization of Surface Combustor using the Metal Fiber (메탈화이버를 이용한 표면연소기의 화염안정화 및 온도특성에 관한 연구)

  • Lee, Jin-Seok;Lee, Young-Hoo;Yun, Bong-Seok;Lee, Do-Hyung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.92-97
    • /
    • 2002
  • By changing the excess air ratio which affects strongly to the combustion characteristics, the flame stability range in the metal fiber burner were found and the range of the blue flame male and radiant mode were distinguished by direct photography. The results in our experiments for the flame stability zone were from a=1.4($354 KW/m^2$) to a=2.06($240 KW/m^2$), and then the blue flame mode zone was form a=1.87($266 KW/m^2$) to a=2.06($240 KW/m^2$) and the radiant mode one was form a=1.4($354 KW/m^2$) to a =1.78($278 KW/m^2$). And the flame was not fired when a is less than the lean condition a=2.45($202 KW/m^2$).

  • PDF

CFD STUDY ON THE COMBUSTION CHAMBER OF A 1 kW CLASS STIRLING ENGINE (1 KW급 LNG 스털링 엔진 연소실 수치해석)

  • Ahn, J.;Lee, Y.S.;Kim, H.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.252-257
    • /
    • 2010
  • The availability of the thermal energy has been deeply recognized recently to encourage the cascade usage of thermal energy from combustion. Within the frame work, a 1 kW class Stirling engine based cogeneration system has been proposed for a unit of a distributed energy system. The capacity has been designed to be adequate for the domestic usage, which requires high compactness as well as low emission and noised. To develop a highly efficient system with satisfying these requirements, a premixed slot flame burner has been proposed and a series of numerical simulation has been performed to establish a design tool for the combustion chamber. The thermal radiation model has been found to highly affect the computational results and a proper resolution to analyze the heat transfer characteristics of the high temperature heat exchanger. Finally, the combustion characteristics of the premixed flame with the metal fiber type burner has been studied.

  • PDF