• Title/Summary/Keyword: Metal Chloride

Search Result 457, Processing Time 0.04 seconds

Microstructural study of polycrystalline films prepared by Ni vapor induced crystallization

  • Ahn, Kyung-Min;Lee, Kye-Ung;Ahn, Byung-Tae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.715-717
    • /
    • 2006
  • $NiCl_2$ vapor was introduced into conventional furnace to conduct vapor-induced crystallization (VIC) process. We made the metal chloride atmosphere by sublimating the $NiCl_2$ compound. The $NiCl_2$ atmosphere enhanced the crystallization of amorphous silicon thin films. As the result, polycrystalline Si film with large grain size and low metal contamination has been obtained.

  • PDF

Evaluation of the corrosion property on the welded zone of seawater pipe by A.C shielded metal arc welding (교류 피복아크 용접에 의한 해수 배관 용접부위의 부식 특성 평가)

  • Jeong, Jae-Hyun;Kim, Yun-Hae;Moon, Kyung-Man;Lee, Myeong-Hoon;Kim, Jin-Gyeong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.877-885
    • /
    • 2013
  • A seawater pipe of the engine room in the ships is being surrounded with severely corrosive environments caused by fast flowing of the seawater, containing aggressive chloride ion and high conductivity etc.. Therefore, the leakage of the seawater from its pipe have been often occurred due to its local corrosion by aggressive chloride ions. Subsequently, its leakage area is usually welded by AC shielded metal arc welding with various electrodes. In this study, when the sea water pipe is welded with several types of electrodes such as E4301, E4311, E4313 and E4316, a difference of the corrosion resistance on the welding metal zones was investigated using an electrochemical method, observing microstructure, measuring polarization behaviors and hardness. The weld metal zone welded with E4313 electrode exhibited the lowest value of hardness compared to other weld metal zones. In addition, its zone indicated also the best corrosion resistance than those of other weld metal zones. Furthermore, all of the weld metal zones revealed a relatively better corrosion resistance than those of the base metal zones. and also showed higher hardness than the base metal zones.

Chloride Diffusion in Hardened Concrete with Concrete Properties and Testing Method (콘크리트 물성 및 시험법에 따른 콘크리트 염화물 확산)

  • Yang Eun-Ik;Kim Myung-Yu;Min Seok-Hong
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.261-268
    • /
    • 2004
  • Corrosion of reinforcement is the main cause of damage and early failure of reinforced concrete structures. The corrosion is mainly progressed by the chloride ingress. In this paper, an experimental study is executed to investigate the effect of concrete properties and testing methods on the coefficients of chloride diffusion. Also, it is surveyed the relationship between total chloride and free chloride in concrete. According to this experiment results, W/C ratio and testing method affect chloride diffusion coefficient of concrete. As W/C ratio is increased, diffusion coefficient in concrete is also increased. Diffusion coefficient obtained by each testing method show the different values, respectively. The model equation of diffusion coefficient with W/C ratio is proposed.

Corrosion of Dental Au-Ag-Cu-Pd Alloys in 0.9 % Sodium Chloride Solution

  • Chiba, Atsushi;Kusayanagi, Yukiharu
    • Corrosion Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.19-22
    • /
    • 2005
  • Two Au-Ag-Cu-Pd dental casting alloys (Au:12% and 20%) used. The test solutions used 0.9 % NaCl solution (isotonic sodium chloride solution), 0.9 % NaCl solution containing 1 % lactic acid, and 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol $dm^{-3}$ $Na_2S$. The surface of two samples in three sample solutions was not natural discoloration during one year. The alloy containing 12 % gold was easily alloyed and the composition was uniform comparing with the alloy containing 20 % gold. The rest potentials have not a little effect after three months. The kinds of metals could not definitely from the oxidation and reduction waves of metal on the cyclic voltammograms. The dissolutions of gold and palladium were 12 % Au sample in the 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol $dm^{-3}$ $Na_{2}S$. The pH of solution had an affect on dissolution of copper, and sulfur ion had an affect on dissolution of silver. The copper dissolved amount from 20 % gold sample was about 26 times comparing with that of 12 % gold sample in the 0.9 % solution containing 1 % lactic acid. Corrosion products were silver chloride and copper chloride in NaCl solution, and silver sulfide and copper sulfide in NaCl solution containing $Na_{2}S$.

A Study on the Desorption Behaviors of Some Heavy Metals on Duolite GT-73 Chelating Resin

  • Kim, Sook-Young;Lee, Jae-Suk;Kim, Young-Man;Choi, Beom-Suk
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.530-534
    • /
    • 2001
  • Effect of stripping solutions on the Duolite GT-73 chelating resin for ten elements, Ag(I), Al(III), Ca(II), Cd(II), Cu(II), Fe(II), Hg(II), Mn(II), Pb(II), and Zn(II), was investigated. Relation between affinities of the metal ions and solubility products of metal sulfides was studied. The smaller the solubility product of metal sulfideis, the larger the affinitie with the ionsis. The ions which have the solubility products larger than $10^{-23}$ could be effectively desorbed with nitric acid. Complexation with chloride ion enhanced the desorption efficiencies of the ions having moderately strong affinity with the resin. The ions which have very strong affinity by the chelating resin can be desorbed by complextion with thiourea and hydrochloric acid.

  • PDF

X-ray Structure and Electrochemical Properties of Ferrocene-Substituted Metalloporphyrins

  • Kim, Jin Won;Lee, Seok U;Na, Yong Hwan;Lee, Gi Pyeong;Do, Yeong Gyu;Jeong, Se Chae
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.12
    • /
    • pp.1316-1322
    • /
    • 2001
  • Transition metal complexes of novel mono- and di-ferrocene-substituted porphyrins have been synthesized and characterized by structural and electrochemical methods. The X-ray structures of Mn(FPTTP)Cl and Mn(DFTTP)Cl showed the distorted square pyramidal coordination geometry with syn configuration of chloride and ferrocenyl substituents. The electrochemistry of ferrocene-substituted porphyrins and their metal complexes has been determined to elucidate the ${\pi}-conjugation$ effect of the porphyrin ring. The ferrocenyl group of H2FPTTP underwent a reversible one-electron transfer process at 0.30 V, indicating the good electron donating effect of the phorphyrin ring to the ferrocene substituent. The redox potential of the ferrocenyl subunit and porphyrin ring was affected by the central metal ions of the metalloporphyrins, that is, Zn(II) and Ni(II) made the oxidation of ferrocene much easier and Mn(III) made it harder. The ferrocene subunits of H2DFTTP interacted electrochemically with each other with peak splitting of 0.21 V. The strength of the electrochemical interactions between the two ferrocenyl substituents can be controlled by central metal ions of metalloporphyrins.

Response Mechanism of 5, 10, 15, 20-tetraphenyl(porphyrinato) Manganase(III) chloride-Based Ion-Selective Membranes (망간포르피린을 함유한 고분자형 이온선택성 막전극의 감응 메카니즘)

  • Hong, Young Ki;Kang, You Ra;Shin, Dae Ho;Shin, Doo Soon;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.270-278
    • /
    • 1996
  • Response mechanism for the chloride-selective membrane doped with 5, 10, 15, 20-tetraphenyl(porphyrinato)manganase(III) chloride(Mn(TPP)Cl) in PVC/DOS matrix is proposed by examining the visible spectra of the corresponding optode membrane. The visible spectra of Mn(TPP)Cl-doped membrane placed in aqueous solution show that the chloride ligand is easily replaced with water molecule. When other halogen ions, such as $F^-$, $Br^-$ and $I^-$, are added to the sample solution, they replace the water ligand, exhibiting distinctive change in the Soret band of Mn(TPP). On the other hand, bulky anions, such as SCN and salicylate, do not form a bond with the central metal. These results suggests that the potentiometric response of Mn(TPP)-based membrane results either from the ligand exchange (water with halides) at the central metal or from the counter ion exchange (chlorides with bulky lipophilic anions) around the positively charged porphyrin molecule in membrane phase. It was also noted that both hydration enthalpies of anions and their binding constants to Mn(TPP) play critical role in determining the potentiometric selectivity pattern of the membrane.

  • PDF

Evaluation of the Deicing Performance and Concrete Structure Effect with Various Deicing Chemicals (제설제 종류에 따른 융빙성능 및 콘크리트에 미치는 영향 평가에 관한 연구)

  • Lee, Byung-Duck;Yun, Byung-Sung;Lee, Joo-Kwang;Chung, Young-Hwan
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.113-123
    • /
    • 2005
  • In this study, calcium chloride$(CaCl_2)$, sodium chloride (NaCl), organic acids-containing deicer(NS 40, NS 100), mixed deicier$(NaCl\;70%+CaCl_2\;30%,\;NS\;40\;70%+CaCl_2\;30%,\;NaCl\;70%+NS\;40\;30%,\;NS\;40\;70%+NaCl\;30%)$ is investigated based on the laboratory test for deicing performance, freez-thaw resistance of concrete, and corrosion rate of metal. Test items for deicing performance were ice melting and ice penetration, freezing point depressions and eutectic point, pH, thermal properties for selected deicing chemicals as well as their compatibility with concrete and metal were experimentally investigated. As a test results, in case of the use chloride-containing deicier in area that concrete structures has subjected to freez-thaw reaction in winter season, it showed that mixed deicing chemicals with optimum ratio has desirable method than use one deicing chemicals when is consider to deicing performance and effects, corrosion of steel materials, and freez-thaw resistance of concrete. When use various deicing chemicals mixed, NS40(70%)+calcium chloride(30%) showed the best effective method.

  • PDF

Volatilization and Toxicity Control of Heavy Metal Chlorides under Combustion Conditions (연소조건에서 중금속 염화물의 휘발 및 유독성 제어)

  • 서용칠
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.4
    • /
    • pp.175-182
    • /
    • 1993
  • Volatilization of toxic heavy metals, especially, metal chlorides at elevated temperatures in oxidation conditions was observed using a thermogravimetric furnace since such metal chlorides used to be a cause for the disease of industrial workers by their toxicity and high volatile extent. Most of tested metal chloride compounds were evaporated or decomposed into gas phase at elevated temperatures ranged from 200~90$0^{\circ}C$, while CrCl$_3$ and NiC1$_2$became stable with converting into oxide forms. A kinetic model for evaporation/condensation could predict maximum evaporation flux and the calculated values were compared with real evaporation flux. The ratio of two fluxes could be explained as the fraction of impinging gas molecules to the condensing surface( $\alpha$ ) and obtained in the range of 10$^{-3}$ ~10$^{-9}$ for the experimented toxic heavy metal chlorides. This ratio might be used to define the volatile extent or toxicity of such toxic metal compounds. The schemes to avoid volatilization of toxic heavy metals Into the atmosphere were suggested as follows ; 1 ) controlling the compositions of metals and Chlorine produced substances( such as PVC ) in the treated materials using a reverse estimation from regulatory limit and characteristics of a processing facility, 2) Installation of wet type devices such as a scrubber for condensing the metal compounds.

  • PDF