• 제목/요약/키워드: Metal Bump Direct Bonding

검색결과 3건 처리시간 0.019초

금속(Au)범프의 횡초음파 접합 조건 연구 (Study of Metal(Au) Bump for Transverse Ultrasonic Bonding)

  • 지명구;송춘삼;김주현;김종형
    • Journal of Welding and Joining
    • /
    • 제29권1호
    • /
    • pp.52-58
    • /
    • 2011
  • In this paper, the direct bonding process between FPCB and HPCB was studied. By using an ultrasonic horn which is mounted on the ultrasonic bonding machine, it is alternatively possible to bond the gold pads attached on the FPCB and HPCB at room temperature without an adhesive like ACA or NCA. The process condition for obtaining more bonding strength than 0.6 Kgf, which is commercially required, was carried out as 40 kHz of frequency, 0.6 MPa of bonding pressure and 2 second of bonding time. The peel off test was performed for evaluating bonding strength which results in more than 0.8 Kgf.

횡 초음파를 이용한 차세대 플렉시블 디스플레이 모듈 저온 접합 공정 연구 (Study of a Low-Temperature Bonding Process for a Next-Generation Flexible Display Module Using Transverse Ultrasound)

  • 지명구;송춘삼;김주현;김종형
    • 대한기계학회논문집A
    • /
    • 제36권4호
    • /
    • pp.395-403
    • /
    • 2012
  • 오늘날 접합시 열에 의한 재료 손상과 접착제(ACA, NCA) 이용으로 부품간의 정렬이 문제가 되고있다. 따라서, 본 논문은 FPCB 와 HPCB 금속(Au) PAD를 직접 접합하였다. 이때 박막인 재료에 손상을 입히는 열, 부품간의 정렬에 문제가 되는 접착제(ACA, NCA)를 사용하지 않고 상온에서 접합을 하였다. 접합시 초음파 혼을 이용하여 접합을 하였으며, 초음파혼은 40kHz이다. 공정 조건은 접합압력 0.60MPa, 접합시간 0.5, 1.0, 1.5, 2.0sec이다. 또한, 산업에서 요구하는 접합강도는 필강도 테스트 결과값으로 0.60Kgf 이상이며, 본 실험에서는 접합강도가 0.80MPa 이상이 나왔다. 이로서, 열에 의한 재료 손상과, 접 착제(ACA, NCA)에 의한 정렬 문제를 해결하였다. 그리고 산업산업에서 바로 적용하고 생산할 수 있는 FPCB, HPCB 시료 제작을 하였다.