• 제목/요약/키워드: Mercury measurement

검색결과 90건 처리시간 0.025초

Replacing Mercury Sphygmomanometers With Mercury-Free Sphygmomanometers for the National Health Survey in Children: Direct Comparisons Applying Two Types of Mercury-Free Sphygmomanometer

  • Sung Hye Kim;Yu-Mi Kim;Seong Heon Kim;Jinho Shin;Eun Mi Lee
    • Korean Circulation Journal
    • /
    • 제54권5호
    • /
    • pp.270-287
    • /
    • 2024
  • Background and Objectives: Blood pressure (BP) measurement using an auscultatory sphygmomanometer is recommended for diagnosing hypertension in children. As mercury sphygmomanometers (MSs) are banned owing to environmental concerns, it is crucial to determine the accuracy of mercury-free sphygmomanometers to replace them. We analyzed the accuracy of these devices to guide the National Survey selection. Methods: BP was measured thrice each with MS, auscultatory device (AD), and oscillometric device (OD) in 104 participants aged 10-18 using the National Survey data. The difference in BP was defined as the difference between MS and other devices. The BP differences, correlations, and influencing factors were analyzed. The frequencies of hypertension were also compared. Results: Systolic BP (SBP) and diastolic BP (DBP) differences between MS and AD were 0.88±3.36 mmHg and 0.63±3.95 mmHg, and those between MS and OD were 0.43±5.83 mmHg and 4.57±6.89 mmHg, respectively. The absolute error of <10 mmHg for DBP between MS and OD was 76%. The concordance correlation coefficient between MS and AD was 0.94 for SBP and 0.90 for DBP, and 0.81 and 0.67, respectively for MS and OD. Arm circumference negatively correlated with BP differences except for SBP between the MS and OD. The frequency of hypertension was not different between MS and AD but was underestimated by OD. Conclusions: AD correlated well with MS, while OD did not, especially for DBP. The superiority of AD over OD suggests AD as a possible alternative for MS in the National Survey.

혈압측정의 정확성 평가 (Evaluating the Accuracy of Blood Pressure Measurement)

  • 조성현;황정해;김은경;오병희;김창엽
    • 한국의료질향상학회지
    • /
    • 제3권1호
    • /
    • pp.94-103
    • /
    • 1996
  • Background : Blood pressure is an important indicator in diagnosis and assessing treatment of a patient. Clinical staffs use blood pressure on the assumption that measured value is accurate and reliable. However, whether measured blood pressure is accurate has been rarely investigated in Korea. Objectives : The aims of this study are to evaluate clinical staffs' knowledge and technique as well as accuracy of sphygmomanometer. Also the program to improve the measurement is developed. Methods : Seventy-three registered nurses were asked nine multiple choice questions including Korotkoff sound, cuff size, and deflation rate. Simultaneously characteristics of nurses were examined, age, working place, duration of employment and academic degree. A testing videotape(Standardizing Measurement Video-Tutored Course) was used for evaluating the accuracy of measurement. Testees were to read and record the 12 cases of blood pressure measurement, watching a falling mercury column and hearing Korotkoff sounds. After 10 minutes' education, they were again tested with the same cases. Additionally, 83 mercury sphygmomanometers were checked to find defects such as inaccurate calibration and zero setting, leaky bladder, etc. Results: For the knowledge testing correct response rate was 41.1%. They were the lowest in selecting the proper cuff size and Korotkoff sound. In examining accuracy of blood pressure with videotape, nurses had 67.7% correct response rate. The correct response rate was significantly improved by a session of education. About 23% of sphygmomanometers was without discernable defects. Conclusion : The knowledge and skill of clinical staffs along with the accuracy of equipment have to be improved. A properly designed education program would contribute to the accuracy improvement of blood pressure measurement. Also, more concerns should be given to the precision and maintenance of equipment.

  • PDF

Changes in Atmospheric Mercury Concentrations in Seoul, Korea and its Significance: A Case Study Between 1997 and 2002

  • Kim Ki-Hyun;Kim Min-Young;Hong SM
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제21권E1호
    • /
    • pp.1-11
    • /
    • 2005
  • The concentration levels of gaseous elemental mercury (GEM) in ambient air have been investigated from a monitoring station located in Yang Jae district of Seoul, Korea for a long-term period covering 1997 through 2002. The mean concentration of Hg, if computed based on its hourly measurement data for this six-year period, was $5.32\pm3.53 ng m^{-3} (N = 27,170)$. The inspection of the diurnal distribution patterns indicated the presence of notably high concentration levels during nighttime relative to daytime (e.g., the mean hourly value as high as $9 ng m^{-3}$ in winter nighttime). When divided seasonally, the highest mean of $6.12 ng m^{-3}$ was also observed during winter followed by spring, fall, and summer. The results of our analysis confirmed the relative dominance of winter (seasonally) or nighttime (diurnally), while exhibiting a complicated trend on a long-term basis. Examination of our data over a different temporal scale consistently indicated that dynamic changes in Hg concentrations occurred through time in line with changes in the strength and diversity of the source processes. It is thus acknowledged that the presence of unusually high Hg levels is the consequence of intense man-made activities, while such signatures can vary in a competitive manner.

극지환경 수은의 대기화학과 환경학적 의미 (Atmospheric Chemistry of Mercury in the Polar Regions and its Environmental Implications)

  • ;김민영;홍성민;손장호;김기현
    • 한국지구과학회지
    • /
    • 제24권5호
    • /
    • pp.420-427
    • /
    • 2003
  • 극지 환경계에서 발견되는 수은의 농도분포는 봄철 극단적인 소멸과 여름철 고농도의 발현과 같이 특이한 분포 특성을 취하는 것으로 밝혀지고 있다. 이와 같은 극지환경의 계절적 농도분포특성은 일반적으로 알려진 수은의 대기환경학적 특성과 상치되는 현상이다. 본문에서는 북극지역에서 장기간 관측된 수은의 농도자료와 이에 대비한 비교 자료 군으로 서울지역을 중심으로 장기 관측된 자료들을 동시에 이강하여, 극지역 수은분포의 특이성과 환경학적 의미를 여러 가지 관점에서 다양하게 고찰하였다.

Screen printing method로 제작된 의료용 광도전체 필름의 Tickness의 따른 X선 검출 특성 평가 (The study of X-ray detection characteristic and fabrication photoconductor film thickness for Screen printing method)

  • 이영규;윤민석;김동혁;천송이;정복동;강상식;박지군;문치웅;남상희
    • 한국방사선학회논문지
    • /
    • 제3권2호
    • /
    • pp.11-16
    • /
    • 2009
  • $HgI_2$의 경우 타 광도전체 물질(a-Se, a-Si, Ge, etc)등에 비해 X선 민감도가 우수하며, 낮은 인가전압에서 구동이 용이한 특성을 가지고 있다. 이러한 특징을 바탕으로 본 연구에서는 HgI2 (Mercury Iodide) 기반의 평판형 디지털 방사선 광도전체 필름을 두께에 따른 구현에 관한 연구를 수행하였다. 본 연구에서는 기존의 PVD(Physical Vapor Deposition)방법의 두꺼운 대면적 필름제조가 어려운 문제점을 해결하기 위해 Screen printing 방법을 사용하였다. 바인더의 종류로는 PVB (Polyvinylbutyral)와 DGME (Diethylene Glycol Monobutyl Ether)와 계면활성제 역할을 하는 DGMEA (Diethylene Glycol Monobutyl Ether Acetate)로 제작하는 바인더를 사용하여 Screen Printing법을 이용하여 각각의 다른 두께를 가지는 다결정의 HgI2 (Mercury Iodide) 필름을 제작하였다. 제작된 필름의 전기적 특성을 dark current, X-선 sensitivity와 SNR(Signal to -Noise Rate) 등을 측정하여 정량적으로 평가 하였다. 그 결과 DG계 200um의 근사하게 제작한 HgI2 (Mercury Iodide) 필름의 전기적특성이 가장 좋게 측정되었다. 얻어진 결과로 볼 때 HgI2 기반의 의료용 광도전체 필름은 기존의 a-Se(Amnorphous seleinum: a-se)를 이용한 디지털 방사선 광도전체 필름의 대체 적용에 대해 충분한 가능성을 보였다.

  • PDF

CuCl2가 담지된 V2O5-WO3/TiO2 SCR 촉매에 의한 수은 및 NOx 동시 제거에서 SO2의 영향 (Effect of SO2 on the Simultaneous Removal of Mercury and NOx over CuCl2-loaded V2O5-WO3/TiO2 SCR Catalysts)

  • 함성원
    • 청정기술
    • /
    • 제28권1호
    • /
    • pp.38-45
    • /
    • 2022
  • HCl에 의한 원소수은 산화활성을 크게 억제하는 것으로 잘 알려진 NH3가 존재하는 SCR조건에서도 CuCl2가 담지된 V2O5-WO3/TiO2 촉매는 원소수은의 산화에 우수한 활성을 나타내었다. 더구나, HCl과 함께 SO2가 반응가스에 존재할 경우에 촉매표면에 담지된 CuCl2가 CuSO4로 변환되는데도 불구하고 뛰어난 원소수은 산화활성이 유지되는 것이 확인되었다. 이는 HCl 뿐만 아니라 촉매 표면에 생성된 SO4 성분이 원소수은의 산화를 촉진시키기 때문으로 판단된다. 그러나 SO2 존재 하에서는 촉매반응 전후의 전체 수은 수지가 맞지 않는 현상이 나타나는데 특히 SO2 농도가 높을수록 심하게 나타났다. 이의 원인 파악을 위해서는 수은 종 분석 방법으로 적용된 SnCl2 수용액에서 SO2의 영향과 촉매표면에 생성되는 황산이온이 원소수은 산화에 미치는 영향에 대한 추가적인 연구가 필요하다. SO2는 NOx 제거 활성도 촉진시키는 것으로 확인되는데 이는 SO2에 의해 촉매 표면에 생성된 SO4에 의한 산점 증가가 NH3 흡착을 용이하게 하기 때문으로 판단된다. 다양한 반응조건에서 촉매 성분의 조성과 구조 변화는 XRD와 XRF로 측정하였으며 이들 측정 결과는 SO2가 본 촉매시스템에서 원소수은의 산화 활성과 NOx 제거 활성을 증진시키는 현상을 합리적으로 설명하는 근거로 제시되었다.

LED광학 시스템이 포함된 3등대형 수은조식 해상용 등명기 개량 (3rd Order Type Mercury Rotate Marine Light with LED Optical System)

  • 김영재;강대웅;이용재;정환;이종복;신경호;박광우;유성환
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2017년도 추계학술대회
    • /
    • pp.206-208
    • /
    • 2017
  • 최근 100여년이 지난 수은조식 3등대형 개량사업을 거문도 등대에서 시행하였으며 독성 있는 수은제거 및 광원의 LED화, 무중단을 대비한 2중화 시스템등을 설치하였으며 이는 국내 최초의 LED 회전식 등명기 설치 및 운용사례라고 볼 수 있다. 등명기 전체 프레임에 대한 원형 복원이 이루어졌으며 2중구조 베어링 설치와 원격제어시스템을 통해 실시간 현황파악이 가능하다. 설치후 한빛호를 통한 광학측정을 통해 유효광도 200만cd 부동광도 300cd의 광학적 성능을 확보하여 LED 광원을 사용한 국내 회전식 등명기 도입의 효율적인 가능성을 입증했다.

  • PDF