• Title/Summary/Keyword: Mercury(II)

Search Result 119, Processing Time 0.023 seconds

Studies on Components of Sarcodon aspratus(II) (능이의 성분(成分)에 관한 연구(硏究)(제(第)2보(報)))

  • Park, Wan-Hee
    • The Korean Journal of Mycology
    • /
    • v.11 no.4
    • /
    • pp.159-162
    • /
    • 1983
  • The dried carpophores of Sarcodon aspratus were examined for mineral elements and a protein-polysacccharide. Calcium, iron, zinc, magnesium, manganese, copper, lead, cadmium and mercury were detected in that order of contents by atomic absorption spectrometry and automatic mercury analysis. The protein-polysaccharide fraction extracted from the carpophore was found to contain 31.5% protein and 52.8% polysaccharide. The fraction showed no antitumor activity against sarcoma 180 implanted in mice.

  • PDF

Biosorption of Hg(II) ions from synthetic wastewater using a novel biocarbon technology

  • Singanan, Malairajan
    • Environmental Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.33-39
    • /
    • 2015
  • Mercury is a toxic pollutants present in different types of industrial effluents and is responsible for environmental pollution. Removal of Hg(II) ions from synthetic wastewater was studied using the activated biocarbon produced from the leaves of Tridax procumbens (Asteraceae). The particle size of the biocarbon (BC) is in the range of $100-120{\mu}m$. The effects of initial metal ion concentration, pH, contact time, and amount of biocarbon on the biosorption process were studied at temperature of $28{\pm}2^{\circ}C$. Batch experimental studies showed that an equilibrium time of 160 min was required for the maximum removal of Hg(II) at the optimized biocarbon dose of 2.5 g per 100 mL of synthetic wastewater. The optimum pH required for maximum removal (96.5%) of Hg(II) ions was found to be 5.5. The biosorption of metal ions onto activated biocarbon surface is probably via an ion exchange mechanism. The biocarbon can be regenerated with minimum loss. Further, it can be reused without any chemical activation. The findings of the research suggested that, the biocarbon produced from cost effective renewable resources can be utilized for the treatment of industrial wastewater.

A Pyrenylboronic Acid-based Fluorescence Sensor for Highly Efficient Detection of Mercury(II) Ions (효율적인 수은이온 검출을 위한 피렌-보론산 기반의 형광센서 개발)

  • Lee, Seung Yeob;Lee, Seoung Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.2
    • /
    • pp.201-207
    • /
    • 2020
  • A new chemosensor based on a self-assembled system has been devised to detect Hg2+ions efficiently. We demonstrated that the amphiphilic building blocks consisting of pyrene and boronic acid (1) aggregate in aqueous solutions and provide an outstanding sensing platform for sensitive detection. The self-assembled 1 exhibited high selectivity and sensitivity for Hg2+ion detection via fluorescence quenching, where the Hg2+ion detection ensued from a fast transmetallation of 1. The Stern-Volmer (SV) quenching constant for its fluorescence quenching by Hg2+ions was approximately 1.58 × 108 M-1. In addition, self-assembled 1 exhibited excellent sensing abilities at nano-molar concentration levels when tap water and freshwater samples were contaminated with of Hg2+ ions.

Preparation and Characterization of a Surface Renewable Solid State Hg/HgO Reference Electrode Utilizing Gold Amalgam

  • Kim, Won;Park, Jong-Man
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.439-442
    • /
    • 2007
  • A solid state Hg(Au)/HgO reference electrode was prepared utilizing gold amalgam solid particles. Solid fine powder of the gold amalgam was prepared by chemical reduction of Au(III) with NaBH4 followed by reduction of Hg(II) in the presence of gold fine particles. The solid content in the suspension of the gold amalgam particles and fine mercury oxide particles in DMF containing PVC was precipitated by the addition of a large amount of water to give solid Hg(Au)/HgO/PVC mixture. After drying, the mixture was pressure-molded to a physically stable Hg(Au)/HgO composite reference electrode material. The electrochemical characteristics of the electrode as a reference electrode were very similar to an ordinary Hg/HgO reference electrode. The electrode material can be molded and fabricated in any desired shape and size. The surface can be renewed by a simple polishing process whenever contaminated or deactivated. The applicability of the electrode in the electrochemical detection of carbohydrates after anion exchange separation was evaluated.

MERCURY LEAKAGE TO SALIVA AFTER AMALGAM FILLING (아말감 충전후(充塡後) 수은(水銀)의 타액내(唾液內) 누출(漏出)에 관(關)한 연구(硏究))

  • Kim, Soo-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.1 no.1
    • /
    • pp.8-10
    • /
    • 1975
  • This study is to determine or detect deposition of mercury particles emitted from dental amalgam fillings. Amalgam fillings were carried out routinely on the dogs' teeth. (CIV cavities) Mercury which contains about 200${\mu}Ci$ of $^{197}Hg$ was employed on this purpose in each cavity. Radioactivity was measured by means of well type scintillation counter from saliva and mucous membrane of surrounding tissue. The C. P. M. value from the saliva was highest, mucous membrane was moderate and least on blood and fecs, as shown table on I. II. III. IV. 1. C.P. Mvalue from Saliva reveals 114 to 135 (lowest and highest) throughout the measuring period until 41 hours. 2. From blood samples no significant value was found. 3. CPM value from feces at2nd day and 4th day was about 90. 4. The highest and lowest CPMvalue from marginal gingiva was 465 and 209 respectively. Palatine showed 281 and 189, esophagus 179 and 165, and pulp from experiment tooth 190 and 104 respectively.

  • PDF

Synthesis of a New Hexadendates Schiff's Base and Its Application in the Fabrication of a Highly Selective Mercury(II) Sensor

  • Ganjali, M.R.;Norouzi, P.;Alizadeh, T.;Salavati-Niasari, M.
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.1
    • /
    • pp.68-72
    • /
    • 2007
  • A new PVC membrane potentiometric sensor that is highly selective to Hg2+ ions was prepared, using bis(2-hydroxybenzophenone) butane-2,3-dihydrazone (HBBD) as an excellent hexadendates neutral carrier. The sensor works satisfactorily in the concentration range of 1.0 × 10-6 to 1.0 × 10-1 mol L-1 (detection limit 4 × 10-7 mol L-1) with a Nernstian slope of 29.7 mV per decade. This electrode showed a fast response time (~8 s) and was used for at least 12 weeks without any divergence. The sensor exhibits good Hg2+ selectivity for a broad range of common alkali, alkaline earth, transition and heavy metal ions (lithium, sodium, potassium, magnesium, calcium, copper, nickel, cobalt, zinc, cadmium, lead and lanthanum). The electrode response is pH independent in the range of 1.5-4.0. Furthermore, the developed sensor was successfully used as an indicator electrode in the potentiometric titration of mercury ions with potassium iodide and the direct determination of mercury in some binary and ternary mixtures.

Effect of High Pressure on Polarographic Parameters of Metal Complex Ion (金屬錯이온의 폴라로그래피的 파라미터에 미치는 壓力의 影響)

  • Heung Lark Lee;Zun Ung Bae;Jong Hoon Yun
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.444-451
    • /
    • 1987
  • The dependence of polarographic parameters on the pressure for the reduction of copper(II), cadmium(II), and zinc(II) complex ions with ethylenediamine, propylenediamine, and diethylenetriamine has been studied. In this study the dropping mercury electrode, the mercury pool electrode, and helix type of platinum wire were used as the working, the reference, and the auxilary electrode, respectively. With increasing the pressure from 1 atmosphere to 1,500 atmospheres, the reduction half-wave potentials of metal complex ions are shifted to the negative values and the diffusion currents become considerably larger, in keeping with the theory on the change of the physical properties of the electrolytic solution such as the density, the viscosity, the dielectric constant, and the electrical conductance, etc. The slope values of the logarithmic plot are increased with increasing the pressure, which indicates the more irreversible reduction. The temperature coefficients of diffusion current observed over the range of the temperature from 25$^{\circ}$C to 35$^{\circ}$C are about two percentage with increasing the pressure, therefore the polarographic reduction under the high pressure is controlled by diffusion. The linear relationships between diffusion current and concentration of metal complex ions are established over all pressure range.

  • PDF