• Title/Summary/Keyword: Membrane-structure

Search Result 1,470, Processing Time 1.318 seconds

Thermoelastic Behaviors of Fabric Membrane Structures

  • Roh, Jin-Ho;Lee, Han-Geol;Lee, In
    • Advanced Composite Materials
    • /
    • v.17 no.4
    • /
    • pp.319-332
    • /
    • 2008
  • The thermoelastic behaviors of an inflatable fabric membrane structure for use in a stratospheric airship envelope are experimentally and numerically investigated. Mechanical tensile properties of the membrane material at room, high, and low temperatures are measured using an $Instron^{(R)}$ universal testing machine and an $Instron^{(R)}$ thermal chamber. To characterize the nonlinear behavior of the inflated membrane structure due to wrinkling, the bending behavior of an inflated cylindrical boom made of a fabric membrane is observed at various pressure levels. Moreover, the envelope of a stratospheric airship is numerically modeled based on the thermoelastic properties of the fabric membrane obtained from experimental data, and the wrinkled deformed shape induced by a thermal load is analyzed.

DEVEOPMENT OF MEASURING SYSTEM OF MEMBRANE STRESS FOR MEMBRANE STRUCTURE (막구조물의 막장력 측정장치 개발에 관한 연구)

  • Jung, Hwan-Mok;Woo, Jae-Won;Cho, Byung-Wook;Lee, Seong-Yeun
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.171-178
    • /
    • 2008
  • This paper is concerned with the development of a measurement system using field measuring device which will give the membrane stress of the membrane structures. Up to this point, several techniques on measurement of membrane stresses has been proposed and some have been used in the fields, but accuracy of the measured stresses to be far from reliable one. Such situation has not been changed until recent days, we do not have the measurement device on which we can depend. On top of that, due to the different properties in cross directions for material of the membrane, the stress in the warp direction is different from that in the fill one. A new method is proposed to measured membrane stresses in two different direction separately, where instead of membrane stresses directly, an external force perpendicular to the membrane to be applied. A portable device can measure the applied force and the displacement. A special testing bed to be fabricated to accommodate $50cm{\times}50$ manbrane specimen which can apply 5 ton load in two orthogonal direction. A special device using push-pull gage was developed. To measure the membrane stresses in warp and fill direction separately, a different length of the tips are used. The measuring device which can called tension meter, can be calibrated on the testing bed, and optimized the length and shape of tip.

  • PDF

Cr (VI) separation by PolyHIPE membrane immobilized with Aliquat 336 by solvent-nonsolvent method

  • Chen, Jyh-Herng;Mai, Le Thi Tuyet;Hsu, Kai-Chung
    • Membrane and Water Treatment
    • /
    • v.8 no.6
    • /
    • pp.575-590
    • /
    • 2017
  • PolyHIPEs membrane prepared with styrene (St), divinylbenzene (DVB), and ethylhexyl acrylate (EHA) can yield a unique pore structure provided by large voids highly interconnected by many small window throats. With the advantageous pore structure, PolyHIPE presents a potential as a support for carrier facilitated transport membrane. Tricaprylmethylammonium chloride (Aliquat 336) can be efficiently incorporated into the PolyHIPE membrane by a two-step solvent-nonsolvent method to obtain an Aliquat 336-immobilized PolyHIPE membrane with good stability. The study of Cr (VI) transport through Aliquat 336-immobilized PolyHIPE membrane indicates that the membrane has high initial flux and maxima stripping flux ($J_f^o=15.01({\mu}mol/m^2s)$, $J_s^{max}=6.15({\mu}mol/m^2s)$). The reusability study shows that the Aliquat 336-immobilized PolyHIPE membrane can maintain high Cr(VI) recovery efficiency even after 15 cycles of operations. The developed membrane was also used in the separation of Cr (VI) from other anions (i.e., $SO_4{^{2-}}$ and $NO_3{^-}$) and other cations (i.e., Ni (II), Mg (II) and Cu (II)) with good selectivity.

역삼투막 재료

  • 김창근
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.09a
    • /
    • pp.31-55
    • /
    • 1998
  • 1. Performance of RO membrane depends on chain structure (packing density) 2. Crosslinking of main chain is essential for the high performance RO membranes 3. Various bisphenols and polyaminostyrene can be promising materials for the fabrication of RO membranes. 4. By using of blend technique of reactant, we can expect broad spectrum of RO membrane and synergetic effects in membrane performance.

  • PDF

Morphological study of synthesized PVDF membrane using different non-solvents for coagulation

  • Yadav, Meenakshi;Upadhyay, Sushant;Singh, Kailash;Chaturvedi, Tarun Kumar;Vashishtha, Manish
    • Membrane and Water Treatment
    • /
    • v.13 no.4
    • /
    • pp.173-181
    • /
    • 2022
  • Polyvinylidene fluoride (PVDF) flat sheet hydrophobic membranes were prepared using 16 wt% PVDF in Dimethyl acetamide (DMAc) by phase inversion technique for desalination application using Membrane Distillation (MD). In this work, the effect of coagulation mediums such as ethanol and water as well their synergistic behavior on the fabricated PVDF membrane morphology was studied using SEM. Moreover, other characteristics required for the membrane distillation applications namely porosity, hydrophobicity and tensile strength were measured using the gravimetric method, sessile drop method and universal testing machine respectively. It was observed that the membrane morphology paradigm shifted from the finger-like structure to the sponge-like structure on increasing the ethanol concentration in coagulant. The porosity of the fabricated membrane was under the required MD range and found to be 57.3% at 16 weight % of PVDF in DMAc solvent under a pure ethanol coagulant bath. Moreover, the top surface contact angle ranges from 85° to 115° on increasing the bath concentration from CBC 0 to CBC 100 at 16 weight % of PVDF in DMAc solvent.

Cement/PVDF hollow-fiber hybrid basement membrane: Preparation, microstructure, and separation application

  • Yabin, Zhang;Xiongfei, Du;Taotao, Zhao
    • Membrane and Water Treatment
    • /
    • v.13 no.6
    • /
    • pp.291-301
    • /
    • 2022
  • In this study, cement/PVDF hollow-fiber hybrid membranes were prepared via a mixed process of diffusion-induced phase separation and hydration. The presence of X-ray diffraction peaks of Ca(OH)2, an AFt phase, an AFm phase, and C-S-H phase confirmed the hydration reaction. Good hydrophilicity was obtained. The cross-sectional and surface morphologies of the hybrid membranes showed that an asymmetric pore structure was formed. Hydration products comprising parallel plates of Ca(OH)2, fibrous ettringite AFt, and granulated particles AFm were obtained gradually. For the hybrid membranes cured for different time, the pore-size distribution was similar but the porosity decreased because of blocking of the hydration products. In addition, the water flux decreased with hydration time, and carbon retention was 90% after 5 h of rejection treatment. Almost all the Zn2+ ions were adsorbed by the hybrid membrane. The above results proved that the obtained membrane could be alternative as basement membrane for separation application.

Analysis of Passive Cooling Effect of Membrane Shading Structure and the Tree by Field Observations in the Summer (하절기 복사환경 관측을 통한 수목과 일사차폐 막 구조물의 자연냉각효과)

  • Choi, Dong-Ho;Lee, Bu-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.137-146
    • /
    • 2007
  • This study is about the passive cooling effects of three outdoor solar shading facilities as trees, pergola with wistaria vine and membrane shading structure, which are expected to provide cool spots in the summer. Field observations of measuring thermal environment of selected facilities is executed. Thermal environment measuring was categorized as short wave radiation, long wave radiation, net radiation, globe temperature, surface temperature measured by infrared camera. Heat transfer mechanism is analyzed with overall data from field measurement. Results from this study are as below; 1) Radiation balance measured on shaded surface under membrane shading structure was 17%($86W/m^2$) of the unshaded surface radiation balance($511W/m^2$). 2) Surface temperature comparison between vegetation and membrane of the shading structure is performed at 3 o'clock in the afternoon. Surface temperature of vegetation was same as air temperature and that of membrane was $5^{\circ}C$ higher than air temperature. Vegetation transpiration is considered as the causing factor which make those differences. 3) Results from this study could be used as fundamental data for reducing heat island phenomena and continuos research on this subject would be needed.

The Term and Classification of Structure System with Non-rigid Member (연성구조시스템의 분류체계와 용어)

  • Lee, Ju-Na;Park, Sun-Woo;Kim, Seung-Deog;Park, Chan-Soo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.2 s.12
    • /
    • pp.99-105
    • /
    • 2004
  • The structure systems with non-rigid member were classified by the composition type of line and surface members. As a result of the classification, there are 1-way cable structure, cable net and radial cable net structure in the line member system. And there are pneumatic structure and suspension membrane structure in surface member system. In addition, when the line and surface members are composed together, there is the hybrid membrane system which are divided into hanging type and supported type. In this paper, the Korean terms of structure systems with non-rigid member are recommended through this classification.

  • PDF

The Development and Historical Character for Structure System with Non-rigid Member (연성구조시스템의 발달과정과 역사적 특성)

  • Lee, Ju-Na;Park, Sun-Woo;Park, Chan-Soo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.3 s.13
    • /
    • pp.93-101
    • /
    • 2004
  • Structural systems have a lot of architectural meaning concerning historical context of structural technology. Therefore, surveying constructed examples and their constructed year, the character and development of various formations of structure systems with non-rigid member were investigated. At the result, the early modem structure systems with non-rigid member were made up from the cable structures, then membrane structures have mainly used after 1970's. The early structural systems had intended to make the large scale space, after 1970's, they have been adopted into the smaller scale space structure, and cable net structure, pneumatic structure and dome typed hybrid membrane system tend to compose the larger scale spare structure.

  • PDF

Theoretical Overview of Membrane Transport (막물질 이동의 이론적 고찰)

  • Park, Young
    • Membrane Journal
    • /
    • v.3 no.3
    • /
    • pp.94-107
    • /
    • 1993
  • Many researchers have discussed how membrane performance can be enhanced through an understanding of polymer science and engineering. The understandings of transport in porous membrane are used to achieve the isolation of certain components from mixtures. Particular emphasis is placed on the applicability of membrane separations for the isolation of macromolecules[1]. An awareness of membrane structure characteristics is required for the rational design of membranes for specific and/or new applications. This understanding rests on the knowledge of fields such as polymer thermodynamics[2], polymer adsorption [3, 4], diffusion in polymers[5, 6], reaction mechanism[7], and the dynamic behavior[8, 9] of polymer in porous membrane.

  • PDF