• Title/Summary/Keyword: Membrane material

Search Result 1,081, Processing Time 0.026 seconds

Transport Coefficients across Charged Mosaic Membrane

  • Yang, Wong-Kang
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.665-667
    • /
    • 2004
  • In previous studies, charged mosaic membranes having two different fixed charges in the membrane matrix indicated unique transport behavior such as preferential material transport. In this study, the composite charged mosaic membrane endurable to mechanical pressure in practical application was investigated from the same aspect of solute and solvent transport as before. Lp and ${\omega}$ estimated by taking account of active layer thickness were satisfactorily consistent with those in mosaic membrane without reinforcement. On the other hand, the reflection coefficient s indicated the negative value that suggests preferential material transport.

Separation of Organic Liquid Mixtures using Plasma Membrane (플라즈마 멤브레인을 이용한 유기용매 혼합을 분리)

  • 김성오;박복기;김두석;박진교;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.642-644
    • /
    • 1999
  • We have prepared the plasma-polymerized membrane for pervaporation of organic-liquid mixtures by the plasma polymerization technique. Plasma polymerization techniques were utilized in the development of hydrophilic composite membranes having high hydrogen ion permeability and excellent dimensional stability. To develop an organic liquid permselective Membrane, suppressing membrane swearing as well as enhancing the solubility difference is impotant. the objectives of the present study are to disign a suitable membrane for an organic-mixture system by the control of the plasma-polymer solubility.

  • PDF

The Evaluation of Mechanical Properties and Fatigue Life for Domestic 304 Stainless Steel Used as Membrane Material in LNG Storage Tank (LNG저장탱크의 멤브레인용 국산 304 스테인리스강의 기계적성질 및 피로수명 평가)

  • Kim, Hyeong-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1644-1650
    • /
    • 2001
  • Mechanical properties of domestic 374 stainless steel have been evaluated fur membrane material used in LNG storage tank. LNG tank is operated around -162$^{\circ}C$. The temperature of membrane depends on LNG level. Accordingly, the membrane material is deteriorated by variation of liquid pressure and temperature. Tensile test and fatigue life test were performed at room temperature and -l62$^{\circ}C$ per code requirements. Especially the biaxial fatigue life test was conducted with shaped membrane sheet at a thermal strain of $\Delta$T=190$^{\circ}C$ The test results obtained with the domestic 304 stainless steel showed better properties compared to the values required by code.

A Study on Tensile Properties and Non-linear Behavior Analysis of Membrane for Stratospheric Airship Envelop (성층권 비행선용 막 재료의 인장 물성 측정 및 비선형 거동에 관한 연구)

  • Lee, Han-Geol;Roh, Jin-Ho;Lee, In;Kang, Wang-Gu;Yeom, Chan-Hong
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.103-106
    • /
    • 2005
  • The material properties of membrane for stratospheric airship is experimentally investigated. Mechanical tensile properties of the membrane material at room, high and low temperature are measured using instron with thermal chamber. Experimentaly, material non-linearity is observed at room and high temperature. In order to simulate material non-linearity caused by the uniaxial extension curve of a woven fabric, the nonlinear hyperelastic problem is considered with finite clement program of ABAQS. Numerical results are compared with experimental results.

  • PDF

An Evaluation Method on the Material Nonlinearity of the Structural Membrane (구조용 막재료의 재료 비선형성 평가기법)

  • 한상을;이승훈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.197-204
    • /
    • 2001
  • The purpose of this paper is to develope the evaluation technique to find proper elastic constants that characterize the material nonlinearity of structural membrane. The stress-strain curves of membrane material show strong nonlinearity. But generally the analysis is carried out under the assumption on material linear and geometrical nonlinear method. Because, it is very difficult to evaluate proper tangential stiffness. This paper use multi-step-linear approximation method taking the concept of effective stress for the evaluation of stiffness of membrane material, and then compare the results between linear and nonlinear analysis. Also. it shows better results than linear method

  • PDF

Membranes for the Guided Bone Regeneration

  • Lee, Sang-Woon;Kim, Seong-Gon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.6
    • /
    • pp.239-246
    • /
    • 2014
  • Many kinds of membrane have been used for the guided bone regeneration (GBR) technique. However, most membranes do not fulfill all requirements for the ideal membrane for the GBR technique. Among them, collagen membrane has been most widely used. However, its high price and weak tensile strength in wet condition are limitations for wide clinical application. Synthetic polymers have also been used for the GBR technique. Recently, silk based membrane has been considered as a membrane for the GBR technique. Despite many promising preclinical data for use of a silk membrane, clinical data regarding the silk membrane has been limited. However, silk based material has been used clinically as vessel-tie material and an electrospun silk membrane was applied successfully to patients. No adverse effect related to the silk suture has been reported. Considering that silk membrane can be provided to patients at a cheap price, its clinical application should be encouraged.

Study on Stress Transition Mechanism and Uniaxial Tensile Characteristics by Tensile Fractured Test of Clamping Part of Membrane Structures (막구조 정착부의 인장파단시험을 통한 신장특성 및 응력전달체계에 관한 연구)

  • Kim, Hee-Kyun;Jeon, Sang-Hyeon;Ha, Chang-Woo;Kim, Jae-Yeol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.3
    • /
    • pp.91-98
    • /
    • 2020
  • For form stability of membrane structures, membrane material is required to be in tension. Therefore, in planning and maintenance management, the engineer should consider enough about introduction of stress during construction and re-introduction of stress after completion. Clamping part is an important portion with the function for introducing tension into membrane materials, and the function to transmit stress to boundary structures, such as steel frames. Then, the purpose of this research is to clarify stress condition and stress transfer mechanism including clamping part of membrane structures, and to grasp the changing tendency of membrane structures with the passage of time. In this research, following previous one, we perform well-balanced evaluation by conducting tensile fractured tests of clamping part's specimens, and by measuring individually the amount of displacement of not only overall specimen's length but membrane material and clamping part. Thereby, we consider the influence the difference in the hardness of edge rope and the difference in the direction of thread affect modification and fracture load.

Change of Phase Transformation Temperature at Fabricated Membrane using Sol-gel Method

  • Cheong, Hun;Choi, Duck-Kyun;Cheong, Deock-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.10
    • /
    • pp.876-880
    • /
    • 2001
  • The supported and unsupported boehmite ($\gamma$-AlOOH) membranes were prepared using a boehmite sol. The supported membrane was consisted of a porcelain support, two intermediate $\alpha-{Al_2}{O_3}$ layers, and a top boehmite membrane. XRD patterns showed that the supported top membrane had a higher $\theta-$ to $\alpha-{Al_2}{O_3}$ transformation temperature compared to the unsupported membrane. This result was also confirmed from microstructural study of the membrane. The shift in the phase transformation temperature should be explained by difference of a stress generated in the supported top membrane due to interaction between the support layers and the top membrane.

  • PDF

Experimental Study on Enhanced Structural Properties of Sprayable Waterproofing Membrane (구조적 성능이 보강된 차수용 박층 멤브레인의 기초 물성평가)

  • Lee, Chulho;Kim, Jintae;Choi, Myung-Sik;Chang, Jun-Hee;Kang, Tae-Ho;Choi, Soon-Wook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.93-102
    • /
    • 2018
  • A sprayable waterproofing membrane which is composed of polymer-based material is relatively easy to install due to its construction method comparing with sheet-type membranes. And a sprayable waterproofing membrane has very similar material composition to the TSL which is for a permanent support. In this study, material composition of the sprayable waterproofing membrane was changed to enhance structural properties of membrane while maintaining waterproofing performance. In order to compare with a previous research for the TSL, series of tests were performed according to the performance criteria used for permanent support material (TSL) by EFNARC (2008). From the test result, the structural performance of the sprayable waterproofing membrane considered in this study showed a performance that could be used as a permanent support material.

Fabrication of Perchlorate Ion Selective PVC Membrane Electrode (과염소산 이온선택성 PVC막전극 제작)

  • 우인성;안형환;강안수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.4
    • /
    • pp.298-305
    • /
    • 1998
  • The PVC membrane electrode for measuring perchlorate ion was developed by incorporating various quaternary ammonium sallts. The effect of chemical structure, the content of active material, the kind of plasticizers, and the membrane thickness on the electrode characteristic such as the linear response range and Nernstian slope of the electrode were studied. It was obtained that the effect of the chemical structure of an active material on the electrode characteristics was improved with increasing the alkyl chain length of the quarternary ammonium salts in the ascending order of Aliquat 336P, TOAP, TDAP, and TDDAP. The optimum membrane composition was 9.09wt% of TDDAP, 30.3wt% of PVC, and 60.6wt% of plasticizer(DBP). And the optimum membrane thickness was 0.45mm at this composition. Under the above condition, the linear response range was $10^{-1}~1.2\times10^{-6}$M, and the detection limit was $5.1\times10^{-7}$M with the Nernstian slope of 57mV/decade of activity of perchlorate ion. The electrode potential was stable within the pH range from 4 to 11. The selectivity coefficient was as shown below: $SCN^->I^-NO_3^->Br^->ClO_3^->F^->Cl^->SO_4^{2-}$

  • PDF