• 제목/요약/키워드: Membrane filtration method

검색결과 116건 처리시간 0.026초

연속공정에 의한 UF용 폴리이미드 분리막의 제조

  • 김완주;전종영;탁태문
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 춘계 총회 및 학술발표회
    • /
    • pp.45-45
    • /
    • 1995
  • Filtration, one of the most important process in the various industrials, is defined as the separation of two or more compounds from a fluid by passing the mixture refers to the separation of solid, immisible particles from liquid or gaseous mixture. Membrane filtration which is a type of filtration extends it's application further to include the separation, concentration, and filtration. The main objective of this investigation is the preparation of organic solvents-resistant polyimide membranes by using phase inversion technique and their application as a UF membrane. Specially, the dope solution was prepared from the newly developed method. The newly developed method is that the dope solution was directly prepared from the polyimide solution which was prepared by the modified one-step polymerization. The effects of the parameters for membrane preparation such as the casting solution composition and the casting conditions were investigated and the performance and chemical stabfiity of membrane are going to be tested.

  • PDF

콘택트렌즈 관리용품의 살균력 효능 검사법 비교 (Comparison of Evaluation Methods for Disinfection Efficacy of Contact Lens Care Products)

  • 성형경;변현영;김소라;박미정
    • 한국안광학회지
    • /
    • 제19권1호
    • /
    • pp.59-67
    • /
    • 2014
  • 목적: 콘택트렌즈 관리용품의 살균력 효능 검사법 기준 개발을 위하여 막여과법(Membrane filtration method)과 희석중화법(Dilution-neutralization method)의 살균력 검사 결과를 비교하고 시판되고 있는 콘택트렌즈 관리용품의 살균력을 제시하고자 하였다. 방법: 포도상구균(Staphylococcus aureus), 녹농균(Pseudomonas aeruginosa), 세라티아균(Serratia marces cens), 칸디다균(Candida albicans)을 대상으로 하여 FDA(Food and Drug Administration)기준인 막여과법과 식품의약품안전처에서 새롭게 가이드라인으로 제시할 희석중화법의 살균력 효능 결과를 비교하였으며 총 20종 다목적 용액의 살균력을 측정하였다. 결과: 살균효과가 강한 살균 성분 및 관리용품의 효능은 막여과법과 희석중화법 모두 동일한 결과를 나타냈다. 살균효과가 약한 관리용품의 경우는 막여과법 검사시에는 균이 뭉쳐있어 정확한 균 수 측정이 불가능하였으나 희석중화법 검사시는 정확한 균 수 측정이 가능해짐을 확인하였다. 또한 시판되고 있는 관리용품 중에는 살균력 기준을 통과하지 못한 제품이 존재하였으며 특히 세라티아균과 칸디다균에 대한 살균력이 약한 경우가 많았다. 결론: 막여과법에 비해 희석중화법이 소량의 샘플로 더 정확하게 균수를 측정하는 것이 가능하며 결과 확인이 빨라 살균력 효능 검사시 유용하게 사용될 수 있음을 알 수 있었다.

역세척, 여과/이완 및 사인파형 연속투과 운전방식에 따른 침지형 평막의 막간차압 (Transmembrane Pressure of Backwashing, Filtration/Relaxation and the Sinusoidal Flux Continuous Operation Modes for Submerged Plate Membrane)

  • 김재효;김은수;정건용
    • 멤브레인
    • /
    • 제29권4호
    • /
    • pp.216-222
    • /
    • 2019
  • 본 연구에서는 역세척이 가능한 평막과 MBR 하부에서 공급되는 공기 및 자연적으로 순환되는 구형 입자를 이용하여 투과 실험하였다. 활성슬러지 수용액은 MLSS 8,000 mg/L로 유지하였으며 여과/이완(FR), 이완시 역세척(FR/BW), 사인파형 연속투과 운전(SFCO) 및 사인파형 연속투과 운전 시 역세척(SFCO/BW) 방식에 따른 막간차압(TMP)을 측정하였다. 역세척 유량을 47에서 $14L/m^2{\cdot}hr$로 감소시키면, TMP가 증가하였으며 SFCO보다는 FR 방식의 TMP가 크게 증가하였다. 또한 역세척 방식이 구형입자를 이용한 세척방식보다 TMP를 더 감소시켰으며, 구형입자와 역세척 방식을 동시에 사용하면 각각의 방법보다 더 효과적임을 확인할 수 있었다.

Effects of Ultrasonic Waves on Filtration Performance and Fermentation in an Internal Membrane-Filtration Bioreactor

  • PARK, BYUNG GEON;WOO GI LEE;WEI ZHANG;YONG KEUN CHANG;HO NAM CHANG
    • Journal of Microbiology and Biotechnology
    • /
    • 제9권3호
    • /
    • pp.243-248
    • /
    • 1999
  • Ultrasonic wave technology was employed to improve filtration performance and ethanol production in a bioreactor equipped with an internal ceramic-membrane filter module. The filtration performance was found to depend on the power and the pattern of ultrasonic wave irradiation. Under the optimized conditions (irradiation time: 25 see, period: 5 min, and ultrasonic power: 60 W), the flux was improved with the periodic-pause method by 200-700% compared with the control (with no irradiation), while the improvement was only 30 to 90% without the periodic-pause method. The final ethanol concentration also increased slightly. However, in a more severe condition (irradiation time: 2.5 min, period: 5 min, and ultrasonic power: 110 W), the irradiation of ultrasonic waves was observed to disturb cell integrity and viability, and thus to decrease ethanol production.

  • PDF

Development of photocatalytic PVA/$TiO_2$ nanofiber membrane by electrospinning and its application for Air Filtration

  • Linh, Nguyen Thuy Ba;Lee, Byong-Taek
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2010년도 춘계학술발표대회
    • /
    • pp.38.1-38.1
    • /
    • 2010
  • Nanofibers have a large potential in air filtration applications. In this work, we have developed a photocatalytic polyvinyl alcohol PVA/$TiO_2$ nanofibers membrane for the treatment of air filtration by using electrospinning method. PVA were electrospun into nanofibrous membranes and $TiO_2$ nanoparticles were loaded in PVA nanofibers in various contents from 10% (w/w) to 50% (w/w). The UV-Vis spectra were conducted for testing the existence of $TiO_2$ nanoparticles in PVA fibers. SEM analysis indicated that $TiO_2$ nanoparticles were loaded on the surface of PVA fibers and dispersed linearly along the fiber direction, which originated from the effect of polarization and orientation caused by high electric field. X-ray diffraction (XRD) was used to determine the crystalline of the membrane. Tensile strength was measured to evaluate the physical properties of the membrane. Therefore, our work suggested that PVA/$TiO_2$ nanofiber membrane has a potential application in air filtration area.

  • PDF

A new method for in line electrokinetic characterization of cakes

  • Lanteri, Yannick;Ballout, Wael;Fievet, Patrick;Deon, Sebastien;Szymczyk, Anthony;Sauvade, Patrick
    • Membrane and Water Treatment
    • /
    • 제4권3호
    • /
    • pp.157-174
    • /
    • 2013
  • The present study is devoted to the validation of a new method for in line electrokinetic characterisation of deposits on membrane surfaces. This method is based upon simultaneous measurements of transversal streaming potential and permeates flux at constant pressure before and during the deposit formation. Dead-end filtration experiments were conducted with negative flat membranes forming a narrow slit channel, negative hollow fiber membranes and mono-dispersed suspensions of (negatively charged) polystyrene latex and (positively charged) melamine particles at various concentrations. It was observed that the overall streaming potential coefficient increased in absolute value with the deposited latex quantity, whereas it decreased and changed of sign during the filtration of melamine suspensions. By considering a resistance-in-series model, the streaming potential coefficient of the single deposit ($SP_d$) was deduced from the electrokinetic and hydraulic measurements. The independence of $SP_d$ with respect to growth kinetics validates the measurement method and the reliability of the proposed procedure for calculating $SP_d$. It was found that $SP_d$ levelled off much more quickly when filtration was performed through the slit channel. This different behaviour could result from a non-uniform distribution of the deposit thickness along the membrane given that the position of measuring electrodes is different between the two cells.

망간과 휴믹산에 의한 세라믹 막 오염의 제어를 위한 약품 스팀세정의 적용 (Chemically enhanced steam cleaning for the control of ceramic membrane fouling caused by manganese and humic acid)

  • 안선아;박철규;이진산;김한승
    • 상하수도학회지
    • /
    • 제35권6호
    • /
    • pp.425-436
    • /
    • 2021
  • In this study, chemically enhanced steam cleaning(CESC) was applied as a novel and efficient method for the control of organic and inorganic fouling in ceramic membrane filtration. The constant filtration regression model and the resistance in series model(RISM) were used to investigate the membrane fouling mechanisms. For total filtration, the coefficient of determination(R2) with an approximate value of 1 was obtained in the intermediate blocking model which is considered as the dominant contamination mechanism. In addition, most of the coefficient values showed similar values and this means that the complex fouling was formed during the filtration period. In the RISM, R c/R f increased about 4.37 times in chemically enhanced steam cleaning compared to physical backwashing, which implies that the internal fouling resistance was converted to cake layer resistance, so that the membrane fouling hardly to be removed by physical backwashing could be efficiently removed by chemically enhanced steam cleaning. The results of flux recovery rate showed that high-temperature steam may loosen the structure of the membrane cake layer due to the increase in diffusivity and solubility of chemicals and finally enhance the cleaning effect. As a consequence, it is expected that chemically enhanced steam cleaning can drastically improve the efficiency of membrane filtration process when the characteristics of the foulant are identified.

Industrial dairy wastewater purification by shear-enhanced membrane filtration: The effects of vibration

  • Kertesz, Szabolcs
    • Membrane and Water Treatment
    • /
    • 제5권2호
    • /
    • pp.73-86
    • /
    • 2014
  • Membrane fouling is a major challenge limiting the use of membrane applications. In this study high induced shear rates were utilized at the membrane surface in order to reduce the organic and inorganic scaling by using the torsional vibration of flat sheet membranes. The performances of a vibratory shear-enhanced processing (VSEP) system for the ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO) membrane filtration of industrial dairy wastewater were investigated. The vibration and non-vibration methods were compared with the same membrane and operational parameters during the purification of real dairy industrial process wastewater. In the initial experiments, short-term tests were carried out in which the effects of vibration amplitude, recirculation flow rate and transmembrane pressure were measured and compared. The permeate flux, turbidity, conductivity and chemical oxygen demand (COD) reduction of dairy wastewater were investigated by using UF, NF and RO membranes with vibration and non-vibration methods. In the subsequent experiments, concentration tests were also carried out. Finally, scanning electron microscopy (SEM) revealed that the vibration method gave a better performance, which can be attributed to the higher membrane shear rate, which reduces the concentration of solids at the membrane, and the transmission.

음이온성 Poly(bis[4-(3-aminophenoxy)phenyl]sulfone pyromellite)Imide Derivatives 한외여과막의 투과특성 (Influence of Ion Exchange Capacity on the Performance of Ultrafiltration Membrane Prepared from Anion Charged Poly(bis[4-(3-aminophenoxy)phenyl]sulfone pyromellite)imide Derivatives)

  • Jong-Young Jeon
    • 멤브레인
    • /
    • 제14권1호
    • /
    • pp.26-36
    • /
    • 2004
  • 상전환 방법으로 제조된 음이온 성 Poly(his[4-(3-aminophenoxy)phenyl]sulfone pyromellite)imide(ACPI) 한외여과막의 순수 투과유속과 용질 배재도 측정치로 투과성능을 연구하였다. ACPI 한외여과막의 투과성능은 캐스팅 용액의 조성과 막 제조 및 측정조건에 영향을 받았다. Bovine serum albumin (BSA) 용액을 pH 2.5-9.0 상태에서 ACPI 한외여과 막의 상대투과유속과 membrane filtration index (MFI) 측정한 결과 BSA의 등전점에서 멀어 질수록 상대투과유속은 증가하고 막 오염정도를 나타내는 MFI는 감소하였다. 또한, 친수성인 ACPI 한외여과막의 이온교환용량(IEC)이 증가할수록 상대투과유속은 증가하고, MFI는 감소하였다.

폴리설펀 한외여과막공정에서 오존의 영향 (Effect of Ozonation on Cross-flow Filtration of Polysulfone Ultrafiltration Membrane)

  • 박영규
    • 멤브레인
    • /
    • 제11권4호
    • /
    • pp.179-189
    • /
    • 2001
  • 폴리설폰 한외여과막 분리막공정을 이용하여 투과유속 상에서의 오존의 효과를 고찰하였다. 처음에는 조제한 페놀용액을 이용해 오존의 농도 10-45 mg/l·min을 가한 후에 분리막내에 막오염 제거를 목적으로 시도하였으며 이후에는 오존과 분리막이 혼합된 연속공정에서 폐수처리를 위해 오존에 의한 통일효과를 고찰하기 위해 시도하였다. 전처리 방법으로는 펜톤 산화법을 이용하여 화학응집을 시도하였고 그 결과 폐수내 용존유기물 제거에 효과가 있는 것으로 나타났다. 실험결과 오존을 이용하게 되면 투과유속이 10% 이상 증가한다는 사실이 조제수와 폐수에 공히 같게 나타났으며 오존과 과산화수소를 이용한 고도처리에서도 투과유속증가에 더욱 효과적이었다. 특히 오존을 이용한 처리수에서는 투과압력이 12% 이상 낮아지는 효과가 나타났으며 분리막 공정에 오존처리는 막오염을 거의 제거하기보다는 막오염을 제한적으로 막는 효과를 얻었다.

  • PDF