• Title/Summary/Keyword: Membrane filtration

Search Result 649, Processing Time 0.029 seconds

Expression and Purification of Toll-like Receptor 9 Cytoplasmic Domain in Pichia patoris (Pichia pastoris로부터 Toll-like Receptor 9의 세포 내 도메인 단백질의 발현과 순수분리 정제)

  • Lee Kyun-Young;Lee Kon-Ho
    • Journal of Plant Biotechnology
    • /
    • v.32 no.4
    • /
    • pp.269-273
    • /
    • 2005
  • Toll-like receptors (TLR) are important components of innate immunity in the defense against pathogens. TLRs recognize pathogen-associated common molecular patterns. TLRs are similar to the receptors involved in defense responses in plants. TLR protein is a type 1 membrane protein, consisting of an extracellular domain containing leucine-rich repeats and a cytoplasmic domain. The cytoplasmic domain delivers ligand recognition signals that result in production of anti-microbial agents. The cytoplasmic domain (amino acid 858-1032) of toll-like receptor 9 has been expressed using methylotrophic yeast Pichia pastoris. The protein expression was confirmed by Western-blot, N-terminal sequencing and MALDl-TOF mass spectrometry. The proteins have been purified by nickel affinity, cation exchange and gel-filtration chromatography.

Change in Cell Size and Buoyant Density of Pseudomonas diminuta in Response to Osmotic Shocks

  • Lee, So-Hee;Cho, Yu-Ree;Choi, Yong-Jin;Kim, Chan-Wha
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.2
    • /
    • pp.326-328
    • /
    • 2001
  • Pseudomonas diminuta (ATCC 19146) has been typically used in the bacterial challenge test for validation of the sterilizing filtration process. Cell size is critical for determining the retention characteristics of membrane filters with pore-size of $0.2{\mu}m$. The changes of cell sizes after osmotic shocks at 150, 260, 500, and 700 mosM were measured by a particle size analyzer and the changes of their buoyant densities were analyzed with a Percoll gradient. The results indicated that there were no significant differences when cells were cultured in 260 mosM medium and osmotically shocked at 500 and 700 mosM. However, the osmotically shocked cells at 150 mosM showed a 38% increase of the cell size compared to the cells at 260 mosM. From these study, we concluded that the worst case condition for validation of a sterilizing filter would be 500 mosM, not because of changes in the cell size, but due to decrease in cell viability under those conditions.

  • PDF

Assessment of microbial quality in household water tanks in Dubai, United Arab Emirates

  • Khan, Munawwar Ali;AlMadani, Asma Mohammad Abdulrahman Ahmad
    • Environmental Engineering Research
    • /
    • v.22 no.1
    • /
    • pp.55-60
    • /
    • 2017
  • Provision of safe, accessible, and good water quality in the community is an important step towards reducing various waterborne illnesses. However, improving the quality of water should include spreading awareness to the public regarding the importance of cleaning their household water tanks. The aim of this study was to investigate the microbial quality of water of household water tanks in Dubai. The water samples from household water tanks were collected from forty houses, and a questionnaire was given to the residents to determine the history of the water tanks. The membrane filtration technique was used to quantify heterotrophic and total coliform bacteria on plate count agar and the violet red bile agar respectively. The overall results of this study have shown that 18 out of total 40 household water tanks contained different types of bacteria concentration level beyond local and widely accepted international standards. The overall results of this study indicated that there is a lack of awareness among residents regarding the importance of maintaining proper sanitation and hygiene of the household water tanks.

A Study on the Treatment of Secondary Effluent by ${\gamma}-ray$ Irradiation ($\gamma$-선의 조사를 이용한 하수처리장 방류수 처리에 관한 연구)

  • 이면주;정영도;박순달
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.2
    • /
    • pp.106-114
    • /
    • 1998
  • This study was carried out for the purpose of industrial reuse of effluent released from activated sludge unit by $\gamma $-ray irradiation technique. The dissolved organic carbon in the effluent of an activated sludge unit is mostly refractory or inert material which are difficult to be degraded by micro organism. The effluent generated from activated sludge unit was irradiated with Co$^{60}$ $\gamma $-ray under condition of air bubbling. The effects of irradiation on the pH, COD, TOC, color, molecular weight distribution were investigated by membrane filtration and u.v.-spectrum analysis. With increasing dose, the TOC was decreased smoothly. The COD was increased at lower dose, while the COD was decreased at higher dose. The TOC and COD, however, were decreased smoothly when TiO$_{2}$ was added to the solution. It was thought that the differential decreasing trend of COD and TOC in according to the absence or presence of TiO$_{2}$ was due to the molecular weight distribution shifted from group of higher molecular weight to group of lower one which are more easy to be decomposed. The removal efficiency of color was 71.5% and it was increased to 85.7% when TiO$_{2}$ was added to the solution. The $\gamma $-ray irradiation was effective on the production of chlorine.

  • PDF

Evaluate the Metal Fiber's Electrical Character and Applicance removal of Ion Derivatives (Metal Fiber의 전기적 특성 평가와 이온제거 Filter로의 응용)

  • Lee, Jin-Sung;Kim, Jun-Hyung;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.265-265
    • /
    • 2010
  • 일반적으로 중금속이나 질산성 질소와 같은 이온성 물질들은 사람의 건강이나 생태계에 좋지 않은 영향을 미칠 수 있다. 이들 오염물질들은 그 종류에 따라 건강에 피해를 주는 정도에 차이가 있지만 안전한 생태환경을 유지하기 위해서는 이들 물질들을 효과적으로 처리할 수 있는 필터가 필요하다. 전극 필터에 최대한 많은 이온들을 흡착시키기 위해서는 전극의 비표면적을 높이는 것이 매우 중요하다. Metal Fiber Filter의 제작과 제작된 Filter의 전기적 특성과 비표면적 향상, 고정성 및 통전성, 축전용량과 전기흡착 및 탈착 경향을 관찰하기 위해 3전극 시스템을 이용하여 Cyclic Voltammetry(CV)와 Chrono-amperometry(CA)를 측정하고 표면의 기공 구조를 관찰하기 위해 주사전자현미경 (SEM;Scanning Electron Microscope)을 이용하여 전극에 생성된 미세 기공의 크기 및 크기 분포를 측정한다. 또한 제작된 Filter 전극을 이용하여 전기장 하에서 수질 속에 있는 질산성이온의 선택적 제거 효율을 측정하여 보고, 측정된 데이터 값을 통해 Metal Fiber Filter의 전기적 특성과 중금속이나 질산성 이온 물질들을 선택적으로 제거할 수 있는 Filter 전극 설계 근거를 제시하고자 한다.

  • PDF

A column study of effect of filter media on the performance of sand filter

  • Kim, Tae-hoon;Oh, Heekyong;Eom, Jungyeol;Park, ChulHwi
    • Membrane and Water Treatment
    • /
    • v.11 no.4
    • /
    • pp.247-255
    • /
    • 2020
  • Sand filter is a key unit process for particle removal in water purification treatments. Its long-standing use is due to on-site customized retrofit. Proper selection of filter media is one of the retrofit approaches to improve filter performance. This study described a series of controlled laboratory column tests and examined the effects of media property on filtration and backwash. When sand media of 0.51 mm in effective size was replaced by sand of 0.60 mm, the filter run increased up to 5 times in the given bed depth. The change of media property required an increase of backwash rate by 0.05 m/min to satisfy the requirement of bed expansion, more than 20%. When the anthracite was changed with lower effective size and uniformity coefficient, correlation with sand in the filter bed could be satisfied within the permissible error between media and bulk characteristics. Besides, this selection resulted in a well-stratified configuration of media layers after bed expansion. The column study showed that the correlation of property between the dual media had a significant effect on the filter productivity and backwash interval.

Coliform Regrowth and Injured Coliforms in Public Water Supply (수돗물에서의 대장균군 재생장과 손상 대장균군)

  • 박성주;조재창;김상종
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.50-57
    • /
    • 1994
  • Densities of total and injured coliforms in treated water( TW ) and three tap water salt pies( Taps Kl, K2 and K3) of Ku- eui water treatment plant and one tap water sample( Tap T) of Tuk- do water treatment plant were measured 23 times from 1991 to 1992. Coliform regrowth in the water distribution system occurred three times during the study period. When the regrowth episode occurred, injured coliforms were always but total coliforms were not always detected in treated water. Mean densities of total coliforms in TW, and Taps Kl, K2, K3 and T were 0.8, 2.3, 1.9, 1.4 and 2.1 cfu/100mℓ by membrane filtration method using m- TF agar and those of injured coliforms were 3.4, 2.8, 2.5, 2.7 and 2.9 c1u/100mℓ using mondo- LES agar. The injury rates of TW and Taps Kl, K2, K3 and T were 89.5,77.4,67.9, 82.8 and 75.9%, respectively. The high injury rate of coliform bacteria in Seoul water supply can cause regrowth problems in distribution systems due to the repair of injured cells under an appropriate condition. It is recommended the injured coliforms should be measured in drinking water since they can lead to a significant underestimation of total coliforms and result in an inaccurate evaluation of the potential health risks.

  • PDF

Wastewater Treatment Process Study for Used Diaper Recycling (사용 후 기저귀 재활용을 위한 폐수처리방안 연구)

  • Kim, Kyung Shin;Lee, Ho Sun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.2
    • /
    • pp.24-33
    • /
    • 2015
  • This study aims to suggest wastewater treatment options for diaper recycling by identifying characteristic analysis of wastewater from diaper recycling process and efficiency evaluation of wastewater treatment units. The wastewater characteristic analysis showed that the concentration of organic pollutants and ionic materials were very high comparing to seawater. Through the investigation of similar wastewater treatment, six treatment units were identified to reduce pollutants. It is found UF(ultra-filtration), DAF(dissolved air flotation), fenton oxidation, electro-coagulation and chemical-coagulation are effective in reducing organic pollutants while membrane system and ion exchanger are effective in reducing ionic materials. Even though the target of water quality should be secured in terms of managing organic pollutants level, the application of treatment unit for reducing ionic material needs lots of considerations. This result suggests that reuse of pulping wastewater after controlling organic pollutants is better than direct discharge of pulping wastewater. To select the appropriate wastewater treatment unit, an economic analysis about operation condition, wastewater flow, cost, efficiency should be considered.

Comparison and application method of seawater desalination pre-treatment process (해수담수화 전처리공정 비교 및 적용 방법)

  • Lim, Hwankyu;Kim, Seunghyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.6
    • /
    • pp.437-446
    • /
    • 2019
  • Reverse osmosis seawater desalination facilities can extend the cleaning cycle and replacement time of the reverse osmosis membrane by pretreatment process. Selection of pretreatment process depends on water quality. It was attempted in this study to select approriate pretreatment process for the Masan bay, which was high in particles and organic content. For this purpose, performances of pretreatment processes such as filter adsorber (FA), pore controllable fiber (PCF), and ultrafiltration (UF) were compared based on the silt density index (SDI). The SDI value of the filtrate should be less than 3. The study results showed that UF can produce the filtrate quality satisfying the requirement. However, the transmembrane pressure (TMP) of UF increased quickly, reaching 0.6 bar within 4 days. In order to secure stable operation, FA and PCF were combined with UF. The study results showed that combination of PCF and UF was able to extend the filtration duration (more than 2 months) until to reach TMP of 0.6 bar.

Purification and Characterization of Adenosine deaminase from Aspergillus oryzae (Aspergillus oryzae에서 Adenosine Deaminase의 정제와 특성)

  • Choi, Hye-Seon
    • Korean Journal of Microbiology
    • /
    • v.31 no.1
    • /
    • pp.54-62
    • /
    • 1993
  • Intracellular adenosine deaminase (ADA) from Aspergillus oryzae was purified using ammonium sulfate fractionation, a DEAE-Sephadex A-50 anion exchange chromatography, an ultrafiltration using a PM 10 membrane and two times of Sephadex G-100 gel filtration chromatography. The enzyme was purified 151 fold with a 9% recovery. Purified enzyme gave a single protein band with a molecular weight of 105,000 delton. The enzyme was reasonably stable. The enzyme activity was kept even after 1 hr incubation at 55.deg.C, but decreased significantly at 60.deg.C. The pH optimum was found to be from 6.5 to 7.5. Among tested compounds, the substrate activity was found with adenosine, adenine arainofuranoside, formymcin A, 2'-deoxyadenosine, 3'-deoxyadenosine, 2', 3'-isopropylidene adenosine, 2,6-diaminopurine deoxyriboside, .betha.-nicotinamide adenine dinucleotide (reduced form), 6-chloropurine riboside, 2'-adenine monophosphate (AMP), 3'-AMP and 5'-AMP. The values of Km of adenosine and 2'-deoxyadenosine were calculated to be 500 and .$710\mu$m, respectively. ADA was sensitivite to $Zn^{2+}$, $^Cu{2+}$ and $Fe^{3+}$, p-chloromercuribenzoate and mersalyl acid inactivated the enzyme. The activity of enzyme was not changed when ADA was incubated with dithiothreititol, 2-mercaptoethanol, N-ethylmaleimide, iodoacetic acid and iodoacetamide.

  • PDF