• Title/Summary/Keyword: Membrane filtration

Search Result 649, Processing Time 0.023 seconds

Analysis of Membrane Fouling Reduction by Natural Convection Instability Flow in Membrane Filtration of Colloidal Solution: Application of Blocking Filtration Model (콜로이드 용액의 막여과에서 자연대류 불안정 흐름의 막오염 저감 효과 해석: 막힘여과 모델의 적용)

  • Kim, Ye-Ji;Youm, Kyung-Ho
    • Membrane Journal
    • /
    • v.29 no.6
    • /
    • pp.329-338
    • /
    • 2019
  • The constant-pressure and constant-flux membrane filtration experiments of alumina colloidal solution are performed to investigate defouling effect of the natural convection instability flow (NCIF) induced in membrane module. The permeate flux at constant-pressure and the transmembrane pressure (TMP) at constant-flux experiments are measured by changes the inclined angle (0, 90 and 180°) of membrane module to the gravity, and flux results are analyzed by using the blocking filtration model. NCIF are more induced as the inclined angles increased from 0° to 180°, and the maximum induced NCIF at 180° angle enhances flux to 2.8 times and reduces TMP to 85% after two-hour operation. As a result of analyzing flux data by applying the blocking filtration model, it is more reasonable to analyze them by using the intermediate blocking model within 15-minute operation time and then thereafter times by using the cake filtration model. The induced NCIF at 180° angle reduces the intermediate blocking fouling at 52% in the early operation time of 15-minute and thereafter the cake layer fouling at 93%. The main membrane fouling control mechanism of NCIF induced in membrane module is evaluated as suppressing the formation of the cake layer of particulate colloidal materials on membrane surface.

Rotating Reverse Osmosis Membrane Filtration (회전 역삼투 분리막 여과)

  • Sangho Lee;Richard M. Lueptow
    • Membrane Journal
    • /
    • v.13 no.3
    • /
    • pp.131-142
    • /
    • 2003
  • Cylindrical rotating reverse osmosis (RO) is a means of dynamic filtration that incorporates both high shear and flow instabilities to reduce membrane fouling. This article summarizes recent works on rotating RO including the physics of rotating filtration; mass - transfer and concentration polarization; theoretical and experimental analysis; and some case studies.

Influence of Ion Exchange Capacity on the Performance of Ultrafiltration Membrane Prepared from Anion Charged Poly(bis[4-(3-aminophenoxy)phenyl]sulfone pyromellite)imide Derivatives (음이온성 Poly(bis[4-(3-aminophenoxy)phenyl]sulfone pyromellite)Imide Derivatives 한외여과막의 투과특성)

  • Jong-Young Jeon
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.26-36
    • /
    • 2004
  • Ultrafiltration membranes based on anion charged poly(bis[4-(3-aminophenoxy)phenyl]sulfone pyromellite) imide derivatives (ACPI) were prepared by the phase inversion method. The polymers have good solubility in aprotic polar solvents. The composition of casting solution and the casting conditions played an important role in determining the permeation characteristics of membrane because the membrane structure could be controlled by the preparation conditions. The extent of fouling-repression was observed by the relative ratio of permeate flux ($J_t$)/pure water flux ($J_0$) and the membrane filtration index (MFI). The characteristics were measured by aqueous solution of bovine serum albumin (BSA) over a pH range of 2.5-9.0. The ACPI membrane having a hydrophilic property was less fouled than the membrane prepared from the original polyimide. With increasing the ion exchange capacity of ACPI membrane, th $\varepsilon$ relative ratio of flux was higher while the membrane filtration index was lower as compared with the original polyimide membrane. From the further away from isoelectric point of bovin serum albumin, the permeation was higher as well as the formation of fouling was more diminish. ACPI membranes having various their properties could be obtained. Further, it was proved that their permeation properties could be determined from the preparation conditions, various operating conditions, and dim $\varepsilon$ rent ion exchange capacity of anion charged polyimide derivatives.

Back Flushing Behavior of Microfiltration Membrane Fouled by Alumna Colloidal Suspensions (알루미나 현탁액에 의해 오염된 정밀여과막의 역세척 거동)

  • Nam, Suk-Tae;Han, Myeong-Jin
    • Membrane Journal
    • /
    • v.19 no.1
    • /
    • pp.34-46
    • /
    • 2009
  • Effect of backflushing on the membrane fouling for polyethylene capillary membranes was examined by measuring the flux of $Al_2O_3$ colloidal suspensions through the cross flow microfiltration. In the comparison of with and without the application of backflushing, the hydraulic resistance to permeate flow of the suspension was less with backfluslng, but the Increasing rate in permeate resistance was higher. Regardless of backflushing, the cake filtration was dominant at the initial period of filtration with backflushing, being followed by the pore blocking. And at steady state, the fouling mechanism is almost governed by the cake filtration model. On the contrary, the pore blocking preceded the cake filtration in the initial stage of the original membrane before backflushing. And irrespective of backflushing, the ratio of cake filtration to total fouling increased, compared with that fur before backflushing. For the membrane with $0.24{\mu}m$ pore size, the permeate resistance was higher than that of $0.34{\mu}m$ pore size membrane. but the ratio of cake filtration was smaller than that of large pore membrane. In comparing the ratio of each fouling component to the total fouling for the case with backflushing pore blocking was 7.8% and cake filtration was 92.2%. for the case without backflushing, total fouling was composed of 9.6% pore blocking and 90.4% cake filtration.

Industrial dairy wastewater purification by shear-enhanced membrane filtration: The effects of vibration

  • Kertesz, Szabolcs
    • Membrane and Water Treatment
    • /
    • v.5 no.2
    • /
    • pp.73-86
    • /
    • 2014
  • Membrane fouling is a major challenge limiting the use of membrane applications. In this study high induced shear rates were utilized at the membrane surface in order to reduce the organic and inorganic scaling by using the torsional vibration of flat sheet membranes. The performances of a vibratory shear-enhanced processing (VSEP) system for the ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO) membrane filtration of industrial dairy wastewater were investigated. The vibration and non-vibration methods were compared with the same membrane and operational parameters during the purification of real dairy industrial process wastewater. In the initial experiments, short-term tests were carried out in which the effects of vibration amplitude, recirculation flow rate and transmembrane pressure were measured and compared. The permeate flux, turbidity, conductivity and chemical oxygen demand (COD) reduction of dairy wastewater were investigated by using UF, NF and RO membranes with vibration and non-vibration methods. In the subsequent experiments, concentration tests were also carried out. Finally, scanning electron microscopy (SEM) revealed that the vibration method gave a better performance, which can be attributed to the higher membrane shear rate, which reduces the concentration of solids at the membrane, and the transmission.

Effective Water Treatment Process by Hollow Fiber MF Membranes; VAS(Vibrating & Stripping by Air ) Process (에너지절약형 VSA MF Membrane 수처리 시스템)

  • 김정학
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.93-116
    • /
    • 1999
  • MF membrane element was specially designed for water purification and VSA process which can solve the fouling problem. Especially VSA process is developed for the SK Chemicals' asymmetric microfiltration hollow fiber membranes. In case of outside-to-in filtration process, MF membrane element showed the excellent flux stability caused by cleaning ability of VSA process . Simultaneous back-washing with VSA consideratbly enhances cleaning efficiency. From the result the possibility of the replacement of chemical coagulation and sand filtration process with newly developed VSA process was revealed.

  • PDF

EFFECTIVE WATER TREATMENT PROCESS BY HOLLOW FIBER MEMBRANES : VAS (VIBRATING & STRIPPING BY AIR) PROCESS

  • Kim, Jeong-Hak
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.63-66
    • /
    • 1999
  • MF membrane element was specially designed for water purification and VSA process which can solve the fouling problem. Especially VSA process is developed for the SK Chemical's asymmetric microfiltration hollow fiber membranes. In case of outside-to-in filtration process, MF membrane element showed the excellent flux stability caused by cleaning ability of VSA process. Simultaneous back- washing with VSA considerably enhances cleaning efficiency. Form the result, the possibility of the replacement of chemical coagulation and sand filtration process with newly developed VSA process was revealed.

  • PDF

Filtration Performance in MSBR (Membrane-Coupled Sequencing Batch Reactor) using a Membrane for Both Filtration and Aeration (막결합형 연속회분식 생물반응조에서 여과 및 공기공급용으로 분리막을 사용할 때 공기공급이 막여과 성능에 미치는 영향)

  • Ryu, Kwan-Young;Park, Pyung-Kyu;Lee, Chung-Hak
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.337-346
    • /
    • 2005
  • An MSBR using a membrane for not only filtration but also aeration (MA-MSBR) was designed to reduce membrane fouling and to enhance water quality, and compared with an MSBR using a membrane for only filtration (BA-MSBR). COD removal efficiency of the MA-MSBR was similar to that of the BA-MSBR, but membrane performance of the MA-MSBR was better than that of the BA-MSBR. The MA-MSBR had more small particles in mixed liquor, so the specific cake resistance of flocs in the MA-MSBR was higher than that in the BA-MSBR. However, in the aerobic reaction step of the MA-MSBR, air went through membrane pores and out of the membrane surface, so cake layers on the membrane surface and a portion of organics adsorbed on membrane pores could be removed periodically. Therefore, cake resistance, $R_c$, and fouling resistance by adsorption and blocking, $R_f$, for the MA-MSBR increased more slowly than those for the BA-MSBR. Additionally, in order to compare the energy efficiency for two MSBRs, oxygen transfer efficiency and power to supply air into the reactor by a membrane module and a bubble stone diffuser were measured using deionized water. From these measurements, the transferred oxygen amount per unit energy was calculated, resulting that of MA-MSBR was slightly higher than that of BA-MSBR.