• Title/Summary/Keyword: Membrane Module

Search Result 347, Processing Time 0.026 seconds

Reduction of energy demand for UF cross-flow membranes in MBR by sponge ball cleaning

  • Issa, Mohammad;Geissen, Sven-Uwe;Vogelpohl, Alfons
    • Membrane and Water Treatment
    • /
    • v.12 no.2
    • /
    • pp.65-73
    • /
    • 2021
  • Sponge ball cleaning can generate an abrasion effect, which leads to an attractive increasing in both permeate flux and membrane rejection. The aim of this study was to investigate the influence of the daily sponge ball cleaning (SBC) on the performance of different UF cross-flow membrane modules integrated with a bioreactor. Two 1"-membrane modules and one 1/2"-membrane module were tested. The parameters measured and controlled are temperature, pH, viscosity, particle size, dissolved organic carbon (DOC), total suspended solids (TSS), and permeate flux. The permeate flux could be improved by 60%, for some modules, after 11 days of daily sponge ball cleaning at a transmembrane pressure of 350 kPa and a flow velocity of 4 m/s. Rejection values of all tested modules were improved by 10%. The highest permeate flux of 195 L/㎡.h was achieved using a 1"-membrane module with the aid of its negatively charged membrane material and the daily sponge ball cleaning. In addition, the enhancement in the permeate flux caused by daily sponge ball cleaning improved the energy specific demand for all tested modules. The negatively charged membrane showed the lowest energy specific demand of 1.31 kWh/㎥ in combination with the highest flux, which is a very competitive result.

Effect of Natural Convection Instability on Reduction of Fouling and Increasing of Critical Flux in Constant-flow Ultrafiltration (정유량 한외여과에서 자연대류 불안정성의 막오염 감소 및 임계 플럭스 증가 효과)

  • Jang, A-Rum;Nam, Sang-Won;Youm, Kyung-Ho
    • Membrane Journal
    • /
    • v.22 no.5
    • /
    • pp.332-341
    • /
    • 2012
  • We studied the effects of induction of natural convection instability flow (NCIF) according to the gravitational orientation (inclined angle) of the membrane cell on the reduction of membrane fouling in the constant-flow ultrafiltration (UF) of colloidal silica solutions. Five colloidal silica solutions with different silica size (average size = 7, 12, 22, 50 nm and 78 nm) were used as UF test solutions. The silica particles in colloidal solutions form cakes on the membrane surface thereby causing severe membrane fouling. The constant-flow UF performance according to the gravitational orientation of the membrane cell (from $0^{\circ}$ to $180^{\circ}$ inclined angle), was examined in an unstirred dead-end cell. We evaluate the effects of NCIF on the suppression of fouling formation by measuring the variation of transmembrane pressure (TMP) and the increase of critical flux by using the flux-stepping method. In the constant-flow dead-end UF for the smaller size (7, 12 nm and 22 nm) silica colloidal solutions, changing the gravitational orientation (inclined angle) of the membrane cell above the $30^{\circ}$ angle induces NCIF in the membrane module. This induced NCIF enhances back transport of the deposited silica solutes away from the membrane surface, therefore gives for the reduction of TMP. But in the constant-flow UF for the more larger size (50 nm and 78 nm) silica colloidal solutions, NCIF effects are not appearing. The critical flux is increased as increasing the module angle and decreasing the silica size. Those results show that the intesity of NCIF occurrence in membrane module is more higher as increasing the module angle and decreasing the silica size.

A Study on Dehumidification Characteristics of Housing with Shape for Pneumatic System (공압시스템 제습용 중공사막 모듈의 하우징 형태에 따른 제습효율 특성 연구)

  • Jeong, Eun-A;Lee, Kee-Yoon;Yun, So-Nam
    • Journal of Drive and Control
    • /
    • v.16 no.2
    • /
    • pp.66-71
    • /
    • 2019
  • In this study, flow analysis and dehumidification experiments were performed on hollow fiber membrane module to confirm the dehumidification characteristics for its different configurations. The CFD for the three different models was conducted using $30^{\circ}C$ temperature and 30%RH inlet humidity for quantitative analysis. Each model has different shape parameters i.e. the number of baffles. Comparison between flow analysis results and dehumidification experiment results revealed a percentage error of about 5%. The difference in relative humidity between the inlet and outlet for each model was calculated using flow analysis data. It was established that the difference in relative humidity of the inlet and outlet for the refined model with three baffles was highest among the three modeled modules of hollow fiber membrane module, i.e. around 9%.

Effect of Operating Conditions and Recovery of Water Back-washing in Spiral Wound Microfiltration Module Manufactured with PVDF Nanofibers for Water Treatment (수처리용 PVDF 나노섬유 나권형 정밀여과 모듈에서 운전조건의 영향과 물 역세척 회복)

  • Kyung, Kyu Myung;Park, Jin Yong
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.180-190
    • /
    • 2015
  • PVDF (polyvinylidene fluoride) nanofiber has the advantages such as excellent strength, chemical resistance, nontoxic, non-combustibility. Flat membranes with 0.3 and $0.4{\mu}m$ pore size respectively, were manufactured by PVDF nanofiber, and then each spiral wound module was prepared with them. A woven paper was not included in preparing the module with $0.3{\mu}m$ pore size; however, it was included the module with $0.4{\mu}m$ pore size. The permeate fluxes and rejection rates of the two modules were compared using pure water and simulation solution including kaolin and humic acid. The recovery rate and filtration resistance were calculated after water back-washing. In addition, the effect of flow rate and trans-membrane pressure on treatment efficiency and filtration resistance were investigated for the spiral wound module with $0.4{\mu}m$ pore size.

Performance Analysis of Plate-and-Frame Forward Osmosis Membrane Module for Concentrating High Salinity Wastewater (고염도 폐수 농축을 위한 평판형 정삼투막 모듈의 성능 분석)

  • Kim, Yu Chang;Lee, Sungyun;Park, Sang-Jin;Kim, Han Seok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.6
    • /
    • pp.68-74
    • /
    • 2016
  • Hydraulic fracturing of wells during oil and gas (O&G) exploration consumes large volumes of fresh water and generates larger volumes of contaminated wastewater with high salinity. It is critical to treat and reuse the O&G wastewater in a cost-effective and environmentally sound manner for sustainable industrial development and for meeting stringent regulations. Recently, forward osmosis (FO) has been examined if it is a promising solution for treatment and desalination of complex industrial streams and especially fracturing flowback and produced waters. In the present study, the performances of a plate-and-frame FO membrane element and a module (6 elements combined in series) were investigated for concentrating high TDS wastewater. An FO module has achieved up to 64 % water recovery (i.e., concentration factor of 2.76) from 10,000 ppm wastewaters and can concentrate feed streams salinities to greater than 30,500 ppm.

Preparation of Alginate Microspheres by Rotating Membrane Emulsification (회전 막유화에 의한 알지네이트 미소 구체의 제조)

  • Min, Kyoung Won;Youm, Kyung Ho
    • Membrane Journal
    • /
    • v.31 no.1
    • /
    • pp.52-60
    • /
    • 2021
  • When preparing calcium alginate microspheres using rotating membrane emulsification that rotates SPG (Shirasu porous glass) tubular membrane in the continuous phase, the optimal conditions of rotating membrane emulsification process parameters for producing monodisperse microspheres were determined. We determined the effects of process parameters of rotating membrane emulsification (the rotating speed of membrane module, the transmembrane pressure, the ratio of dispersed phase to continuous phase, the alginate concentration, the emulsifier concentration, the stabilizer concentration, the crosslinking agent concentration, and the membrane pore size) on the mean size and size distribution of alginate microspheres. As a result, the size of the microspheres decreased as the rotating speed of membrane module, the emulsifier concentration, and the crosslinking agent concentration increased among the process parameters of rotating membrane emulsification. On the contrary, as the ratio of dispersed phase to continuous phase, the transmembrane pressure, and the alginate concentration increased, the size of the microspheres increased. In the rotating membrane emulsification using an SPG membrane with a pore size of 3.2 ㎛, it was possible to finally prepare monodisperse alginate microspheres with a particle size of 4.5 ㎛ through the control of process parameters.

Characteristics of the Sinusoidal Flux Continuous Operation Mode for the Submerged Flat-sheet Membrane Module in Cutting Oil Solution (절삭유 수용액내 침지식 평막 모듈에 대한 사인파형 투과유속 연속운전 방식의 특성)

  • Won, In Hye;Chung, Kun Yong
    • Korean Chemical Engineering Research
    • /
    • v.53 no.5
    • /
    • pp.646-652
    • /
    • 2015
  • In this study transmembrane pressure (TMP) was measured with respect to permeate flux through the submerged flat sheet membrane for the emulsion and semi-synthetic cutting oil solutions. The effective area and nominal pore size of the used microfiltration membrane were $0.02m^2$ and $0.15{\mu}m$, respectively. The experiments were carried out simultaneously for run/stop (R/S) and sinusoidal flux continuous operation (SFCO) modes using two submerged membrane module in the reservoir. TMP for the case of SFCO was maintained under 60% of R/S, and the effect on TMP drop decreased as the permeate flux increased for emulsion cutting oil solution. Membrane fouling for the semisynthetic solution showing low turbidity was induced lower comparing to the emulsion solution. Also, the effect on TMP drop for SFCO decreased during long-term operation.

Development of a Parametric Design System for Membrane Structures (연성 막구조의 파라메트릭 설계 시스템 개발)

  • Choi, Hyun-chul;Lee, Si Eun;Kim, Chee Kyeong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.4
    • /
    • pp.29-36
    • /
    • 2016
  • The objective of this research is to development of a parametric design system for membrane structures. The parametric design platform for the spatial structures has been designed and implemented. Rhino3D is used as a 3D graphic kernel and Grasshopper is introduced as a parametric modeling engine. Modeling components such as structural members, loading conditions, and support conditions are developed for structural modeling of the spatial structures. The interface module with commercial structural analysis programs is implemented. An iterative generation algorithm for design alternatives is a part of the design platform. This paper also proposes a design approach for the parametric design of Spoke Wheel membrane structures. A parametric modeling component is designed and implemented. SOFiSTik is examined to interact with the design platform as the structural analysis module. The application of the developed interface is to design optimally Spoke Wheel Shaped Ductile Membrane Structure using parametric design. It is possible to obtain objective shape by controlling the parameter using a parametric modeling designed for shape finding of spoke wheel shaped ductile membrane structure. Recently, looking at the present Construction Trends, It has increased the demand of the large spatial structure. But, It requires a lot of time for Modeling design and the Structural analysis. Finally an optimization process for membrane structures is proposed.

Performance improvement of countercurrent-flow membrane gas absorption in a hollow fiber gas-liquid membrane contactor

  • Ho, Chii-Dong;Sung, Yun-Jen;Chen, Wei-Ting;Tsai, Feng-Chi
    • Membrane and Water Treatment
    • /
    • v.8 no.1
    • /
    • pp.35-50
    • /
    • 2017
  • The theoretical membrane gas absorption module treatments in a hollow fiber gas-liquid membrane contactor using Happel's free surface model were obtained under countercurrent-flow operations. The analytical solutions were obtained using the separated variable method with an orthogonal expansion technique extended in power series. The $CO_2$ concentration in the liquid absorbent, total absorption rate and absorption efficiency were calculated theoretically and experimentally with the liquid absorbent flow rate, gas feed flow rate and initial $CO_2$ concentration in the gas feed as parameters. The improvements in device performance under countercurrent-flow operations to increase the absorption efficiency in a carbon dioxide and nitrogen gas feed mixture using a pure water liquid absorbent were achieved and compared with those in the concurrent-flow operation. Both good qualitative and quantitative agreements were achieved between the experimental results and theoretical predictions for countercurrent flow in a hollow fiber gas-liquid membrane contactor with accuracy of $6.62{\times}10^{-2}{\leq}E{\leq}8.98{\times}10^{-2}$.