• 제목/요약/키워드: Membrane Integrity Test

검색결과 58건 처리시간 0.02초

Adaptation of the Hypoosmotic Swelling Test to Evaluate Membrane Integrity of Boar Spermatozoa

  • Jang, Hyun-Yong;Cheong, Hee-Tae;Hwang, Hwan-Sub;Kim, Jong-Taek;Park, Choon-Keun;Lee, Hak-Kyu;Yang, Boo-Keun
    • Reproductive and Developmental Biology
    • /
    • 제31권2호
    • /
    • pp.121-126
    • /
    • 2007
  • The objective of this study was to establish the optimal conditions for hypoosmotic swelling (HOS) test to assess the functional integrity of the membranes of boar fresh or frozen/thawed spermatozoa. When pooled semen sample was incubated for 30 min at $37^{\circ}C$ with different test solution of varied osmolarity, the highest percentage of HOS positive spermatozoa was observed in a 150 mOsmol fructose/Na-citrate solution (33.6%). Incubation time did not affect significantly the score of HOS positive spermatozoa observed in a 150 mOsmol fructose/Na-citrate solution at $37^{\circ}C$, but the osmolarity affected the score of HOS positive spermatozoa under the same condition above. Fresh semen was significantly better than frozen/thawed semen in semen parameters evaluated such as motility, viability, membrane integrity and lipid peroxidation (p<005). In the relationships of sperm parameters, motility vs viability, motility vs membrane integrity and viability vs membrane integrity were positively correlated ($0.82{\sim}0.94$) but lipid peroxidation vs other estimated factors was negatively correlated ($- 0.90{\sim}- 0.98$). Among the evaluation methods, motility vs Viability, motility vs membrane integrity and lipid peroxidation vs other estimated factors were significantly correlated (p<0.05). These results of this. study indicate that the optimal condition of HOST in boar spermatozoa is a 150 mOsmol fructose/Na-citrate solution for 30 min incubation at $37^{\circ}C$ and HOST can substitute the examination of motility, viability and lipid peroxidation.

하수재이용에서 전처리 막 손상에 의한 수질변화가 SDI에 미치는 영향평가 (Evaluation of Water Quality Change by Membrane Damage to Pretreatment Process on SDI in Wastewater Reuse)

  • 이민수;서동주;이용수;정건용
    • 멤브레인
    • /
    • 제32권4호
    • /
    • pp.253-263
    • /
    • 2022
  • 본 연구에서는 하수 재이용을 위한 역삼투막 공정에서 전처리 정밀여과막(MF) 손상에 대한 누출되는 다양한 수질변화로써 막 손상 검지 방안을 제시하였다. 이를 위하여 역삼투막 유입수질 적합성 평가지표인 SDI (silt density index)를 3에서 5의 범위 내에서 막 손상 시 검지 감도를 정량화하기 위하여 전처리 분리막이 1에서 3가닥 파단에 따라 SDI는 1.92에서 6.11까지 증가한 결과를 확인할 수 있었다. 일반적으로 3을 기준으로 역삼투막 유입수질로 설정하였을 때 분리막이 3가닥까지 파단이 되어야만 막 손상 검지가 가능하다는 것을 의미하며 역삼투막의 오염은 잠재적으로 가속화되어 효율을 저하시킬 수 있다. 또한 이때 누출되는 입자성과 유기물질에 대하여 0.45 ㎛ 이상의 크기만 걸러주는 입자계수는 입도분포별 막 파단 개수에 따라 일정한 패턴을 확인할 수 없었으며, TOC 농도는 약 2배의 변화패턴으로써 SDI와의 상관관계로써 TOC가 막 손상 수질지표로써 신뢰성이 높은 것으로 확인되었다. 수질분석결과와 더불어 USEPA에서 제시하는 막 손상 검지 방법 중 압력손실시험과 이를 기반으로 LRVDIT 모델의 적합성 평가를 한 결과 막 손상 또는 역삼투막 공정으로 유입되는 막오염물질을 신속하게 확인할 수 있는 SDI 및 TOC를 포함한 LRVDIT 모니터링과 UCL 설정을 병행해야 한다.

압력손실시험을 이용한 막 완결성 평가에서 초기압력 및 UCL 도출인자 민감도 분석 (Sensitivity Analysis of Initial Pressure and Upper Control Limit on the Pressure Decay Test for Membrane Integrity Evaluation)

  • 이주희;홍승관;허현철;이광제;최영준
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.793-800
    • /
    • 2008
  • Recently domestic drinking water industry has recognized membrane-based technology as a promising alternative for water treatment. To ensure successful application of membrane processes, the integrity of membrane systems should be maintained. According to US EPA guidance, the pressure decay test based on the bubble point theory is recommended to detect any membrane defection of which size is close to the smallest diameter of Cryptosporidium oocysts, $3{\mu}m$. Proper implementation of the pressure decay test is greatly affected by initial test pressure, and the interpretation of the test results is associated with upper control limit. This study is conducted to investigate various factors affecting determination of initial test prtessure and upper control limit, including membrane-based parameters such as pore shape correction factor, surface tension and contact angle, and system-based parameters, such as volumetric concentration factor and total volume of system. In this paper, three different hollow fibers were used to perform the pressure decay test. With identical initial test pressure applied, their pressure decay tendency were different from each other. This finding can be explained by the micro-structure disparity of those membranes which is verified by FESEM images of those membranes. More specifically, FESEM images revealed that three hollow fibers have asymmetry, deep finger, shallow finger pore shape, respectively. In addition, sensitivity analysis was conducted on five parameters mentioned above to elucidate their relation to determination of initial test pressure and upper control limit. In case of initial pressure calculation, the pore shape correction factor has the highest value of sensitivity. For upper control limit determination, system factors have greater impact compared to membrane-based parameters.

막 손상 측정을 위한 압력손실시험의 감도에 영향을 미치는 인자 (Influencing Factors on Sensitivity of Pressure Decay Test for Membrane Damage Assessment)

  • 이용수;김형수;김종오
    • 멤브레인
    • /
    • 제27권4호
    • /
    • pp.367-373
    • /
    • 2017
  • 중공사형 정밀여과(MF)와 한외여과(UF)를 포함한 가압식 막여과 시스템은 높은 수준의 병원균 제거 효율로 인해 음용수 처리에 점점 더 많이 사용되고 있다. 그러나 가압식 막여과 시스템에서 분리막의 손상으로 인한 막완결성의 문제가 발생시 병원체가 유출될 수 있으므로, 효과적인 온라인 또는 오프라인 방식의 막 완결성 모니터링 방법을 통해 수질의 안정성을 보장하여야 한다. 최근 막 완결성 시험 중 하나 인 압력손실시험(pressure decay test, PDT)이 가압식 분리막 모듈을 이용한 음용수 처리 시설에 적용되고 있다. 이 논문에서는 PDT의 기체 주입방법에 따른 세 가지 조건으로 원수 측, 여과수 측, 원수 여과수 양방향 측 세 가지 조건을 선정 후 이에 따른 감지감도를 이론값과 실험값을 적용하여 비교하였다. 실험결과 가압되는 측의 부피와 감도는 반비례함을 확인하였고, 주입부의 반대방향에 부압을 형성 시에도 감도가 증가함을 확인할 수 있다. 즉 막 손상의 감지감도는 주입되는 부분의 체적이 작아질수록, 분리막을 경계로 유입과 여과 측의 압력차가 클수록 높아짐을 알 수 있었다.

막 파단 및 공극크기에 따른 막 완결성 및 제거효율 분석 (Analysis of Membrane Integrity and Removal Efficiency Considering Membrane Defect and Pore Size)

  • 허현철;이옥재;이광제;김광호;최영준;이주희;홍승관
    • 한국물환경학회지
    • /
    • 제24권4호
    • /
    • pp.423-429
    • /
    • 2008
  • Microfiltration (MF) and ultrafiltration (UF) processes for removal of particulate materials (i.e., turbidity, microorganisms and viruses) have been used to produce drinking water with higher quality. As membrane filtration technique has become widely applied for drinking water treatment, the importance of membrane integrity test (MIT) has also been increasingly emphasized. The results of pressure decay test (PDT) were presented in the paper to monitor membrane integrity. In this paper the PDT was carried out with deliberately-defected membrane fibers to evaluate the sensitivity of PDT on membrane fiber damage. Variation of pressure decay rate and removal rate were investigated to evaluate the impact of defection (defection ratio) and pore size of membrane. The membrane integrity could be successfully monitored by the PDT. The pressure decay rate varied from $0.002{\sim}0.189kg_f/cm^2hr$ with the initial pressure ranged from 0.2 to $1.0kg_f/cm^2hr$. Higher initial pressure which provided with higher pressure decay rate was preferred to evaluate the defection of membrane fiber. As for the particle removal rate, the Log Removal Rate (LRV) of kaolin solution decreased significantly from 3.78 to 2.31 when one fiber out of 3,200 fibers was cut. The membranes with different pore size were tested to evaluate virus removal efficiency. The virus removal rate of the MF membrane ($0.1{\mu}m$) was about 30% although the poliovirus was smaller than the pore size of the MF membrane, indicating that the removal rate was much lower than Korea Water Works Association (KWWA) certificate LRV of 1.5.

Effect of Different Conditions on the Hypoosmotic Swelling Test to Evaluate Functional Integrity of Canine Spermatozoa

  • 오진영;장현용;서정수;정유성;김종택;정희태;박춘근;김정익;양부근
    • 한국동물번식학회:학술대회논문집
    • /
    • 한국동물번식학회 2004년도 춘계학술발표대회
    • /
    • pp.277-277
    • /
    • 2004
  • The purpose of this study was to investigate the effect of different conditions (osmolity, solution, incubation times, comparison of fresh and frozen/thawed semen and storage times) on the swelling of canine spermatozoa. Employing the hypoosmotic swelling test (HOST), the membrane integrity of spermatozoa in different solutions (sucrose, fructose, latose, Na-citrate, Na-citrate plus sucrose, Na-citrate plus fructose and Na-citrate plus lactose were 61.4%, 66.2%, 62.5%, 68.1%, 62.0%, 68.5% and 60.2%, respectively. (omitted)

  • PDF

막 완결성 모니터링 신뢰성 향상을 위한 손상 유형별 막 손상 감도 평가 (Evaluation of Membrane Damage Sensitivity by Defect Types for Improving Reliability of Membrane Integrity Monitoring)

  • 이용수;강하영;김형수;김종오
    • 멤브레인
    • /
    • 제27권3호
    • /
    • pp.248-254
    • /
    • 2017
  • 내염소성 원생동물인 크립토스포리디움, 지아디아 등 병원성 미생물의 제거에 대한 신뢰성을 확보하기 위해 정수처리 공정에서 막여과 시스템이 각광받고 있으며, 이러한 신뢰성을 보증하기 위해 막 완결성에 대한 연구가 중요시되고 있다. 막 완결성 시험은 크게 직접법과 간접법으로 분류되는데, 직접법 중 압력기반의 시험은 버블포인트 이론을 근간으로 병원성 미생물의 최소 크기인 $3{\mu}m$ 크기 이상을 감지할 수 있는 감도로 USEPA Guidance Manual에서 제시하고 있다. 간접법은 온라인 상태에서 연속적인 운전이 가능하다는 점에서 널리 사용되지만, 직접법에 비해 현저히 낮은 막 손상 감지 감도를 가지고 있으며, 손상 부위를 특정 지을 수 없는 한계가 있기에 이러한 감지 감도를 개선해야 할 필요가 있다. 따라서 본 연구에서는 압력 손실 시험에 의한 막 완결성 시험을 통해 막 파단 형태별, 파단 개수, 초기설정압력값에 따른 압력손실률과 LRVDIT 신뢰성 범위를 상호 비교함으로써 막 손상에 따른 감도의 결과를 정량화하여 UCL 기준을 나타내어 비교 평가하였다.

형광입자를 이용한 분리막 표면 검측과 손상 면적 추정 오차에 대한 연구 (Estimation of damage area on membrane surface by application of fluorescent particles as a surrogate)

  • 최윤경;김초아;김희준;조진우
    • 상하수도학회지
    • /
    • 제28권2호
    • /
    • pp.171-179
    • /
    • 2014
  • In this study, a novel method was proposed to test the integrity of water treatment system specifically equipped with membrane filtration process. We applied the silica particles coated with a fluorescent agent (rhodamine B isothiocyanate) as a surrogate to detect a membrane process integrity and evaluate the reliability of effluent quality in the system. Additionally, a series of experiments was conducted to evaluate the sensitivity of the method through the laboratory scale experiment. The laboratory scale experiments showed that the feasibility of application of proposed method to detect a breach or damaged part on the membrane surface. However, the sensitivity on predicting the area of a breach was significantly influenced by the testing conditions such as a concentration of surrogate, filtration flux, and detection time. The lowest error of predicting the area of breach was 3.5% at the testing condition of surrogate concentration of 80 mg/L injected with flux of $20L/m^2/hr$ for 10 minutes of detection time for the breach having the actual area of $7.069mm^2$. However, the error of estimation was increased at the small breach with area less than $0.785mm^2$. A future study will be conducted to estimate a damaged area with more accuracy and precision.

Effects of Storage in Different Commercial Semen Extenders on Sperm Motility, Viability and Membrane Integrity of Korean Native Boar Spermatozoa

  • Sa, Soo-Jin;Kim, In-Cheul;Choi, Sun-Ho;Hong, Joon-Ki;Kim, Du-Wan;Cho, Kyu-Ho;Kim, Young-Hwa;Chung, Ki-Hwa;Park, Jun-Cheol
    • 한국수정란이식학회지
    • /
    • 제28권4호
    • /
    • pp.349-353
    • /
    • 2013
  • The objective of this study was to compare the effect of semen extenders on the sperm motility, viability, acrosome integrity and functional integrity of plasma membrane (HOST: hypo-osmotic swelling test) during liquid preservation of Korean Native boar semen. In this experiment, semen was diluted in Androhep plus, Beltsville Thawing Solution (BTS), ModenaTM, Seminark and Vitasem LD. Sperm-rich fractions were collected from three Korean Native boars and sub-samples were diluted ($30{\times}10^6$ spermatozoa/ml) in different semen extenders. Semen samples were stored at $17^{\circ}C$ for 96 hours. On everyday (0, 24, 48, 72, 96 h) after storage, the sperm characteristics relevant for fertility, such as sperm motility, viability, acrosome integrity and HOST positive were evaluated. The motility of spermatozoa stored in different extenders was no significantly different among other extenders (P>0.05). Also, no difference was observed among samples processed with different extenders in the percentage of sperm viability, acrosome integrity and HOST positive. All extenders maintained a high percentage (70%) of sperm motility, viability and acrosome integrity through 96 h of storage. The result of this study show that there was no significant differences among extenders in their capacity to preserve motility, viability and membrane integrity of spermatozoa from normal, fertile Korean Native boars for 96 h of liquid preservation at $17^{\circ}C$.

형광입자를 이용한 분리막 표면 검측 방법의 파일럿 규모 플랜트 적용 (Application of fluorescent particles as a tracer to detect the membrane surface damage in a pilot scale membrane bioreactor)

  • 김초아;김희준;조진우
    • 상하수도학회지
    • /
    • 제30권1호
    • /
    • pp.33-40
    • /
    • 2016
  • In this study, a fluorescent silica nano particle is used as the surrogate for challenging test of membrane surface integrity. The particles are functionalized by a fluorescent dying agent so that as an ultraviolet light is imposed a bright fluorescent image from the particles can be taken. If a membrane surface is damaged and has a compromised part larger than the size of surrogate the fluorescent particles would pass through and contained in the permeate. An operator can directly notice whether the membrane surface is damaged or not by detecting a fluorescent image taken from the permeate. Additionally, the size of compromised part is estimated through analysing the fluorescent image in which we surmise the mass of particles included in the permeate by calculating an average RGB value of the image. The pilot scale experiments showed that this method could be applied successfully to determine if a membrane surface had a damaged parts regardless of the test condition. In the testing on the actual damaged area of $4.712mm^2$, the lowest error of estimating the damaged area was -1.32% with the surrogate concentration of 80 mg/L, flux of $40L/m^2/hr$ for 25 minutes of detection. A further study is still going on to increase the lowest detection limit and thus decrease the error of estimation.