• Title/Summary/Keyword: Membrance

Search Result 73, Processing Time 0.018 seconds

RO Chemicals 종류 및 운영

  • Martinson, Tom
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.09a
    • /
    • pp.57-85
    • /
    • 1998
  • RO System & Membrance Support Technology Membrance Fouling -Colloidal Fouling -Scale Fouling -Biological Fouling -Chemical Fouling

  • PDF

A Strady-State One-Dimensional Analysis of an Oxygen Electrode in Stationary and Flowing Liquid (정체 및 유동액체에서 산소전극의 안정상태 일차원적 해석)

  • 김태진
    • KSBB Journal
    • /
    • v.4 no.2
    • /
    • pp.150-156
    • /
    • 1989
  • The chaacterisitics of a commercial membrance-coverd electrode in air-saturated saline solution were investigated in terms of a steadystate one-dimensional model. The electrode system miiersed in an aqueous medium consists of three layers: an external concentration boundary layer, a membrance, and an inner electrolyte layer. The membrance can be permeabld to the water and impermeable to the ionic species. In stationary midium, the water migrates from the external medium to the inner electrolyte layer until a thermodynamic equilibrium is reached. In a following midium, however, there is a reverse direction of water movement due to the hyrodynamic pressure differential until both thickness of the electrolyte layer and the membrance are equal.

  • PDF

신장근위곡세뇨관 소포를 이용한 신장독성 실험모델 개발 2.Uranyl acetate가 신장근위곡세뇨관 소포에서의 물질이동에 미치는 영향

  • 이영재;이창업;류판동;박종명;박근식
    • Toxicological Research
    • /
    • v.8 no.1
    • /
    • pp.95-107
    • /
    • 1992
  • Basolateral and brush border membrance (BLM and BBM) vesicles of renal proximal tubules were prepared from adult male New Zealand White rabbits to develop an experimental for assessment of nephrotoxicity. PAH uptakes using BLMV, and glucose and leucine uptakes using BBMV were measured in the rabbits treated uranyl acetate. In addition, urinalysis and histopathological studies were performed to investigate the correlationship with the membrance vesicle uptakes.

  • PDF

Optimal Immobilization of Penicillinase for Ion-selective Electrode

  • Hur, Moon-Hye;Kang, Hee-Jin;Min, Hye-Young;Lee, Ji-Yeun;Lee, Ki-Hyun;Ahn, Moon-Kyu
    • Archives of Pharmacal Research
    • /
    • v.20 no.1
    • /
    • pp.68-71
    • /
    • 1997
  • Penicillin sensor was prepared by immobilizing penicillinase (Pcase) on $H^{+}$-selective carboxylated poly (vinyl chloride) (PVC-COOH) membrane or cellulose filter membrane. The immobilization techniques are as follows. Pcase was immobilized with GTH on $H^{+}$-selective PVC-COOH membrane or some amount of BSA was dropped on that membrane. Another method to make immobilization is to mix type I Pcase with GTH and drop on a cellulose filter membrane. According to immobilization techniques, there were some differences in response properties of enzyme electrodes, however, all electrodes responded to Pcase-resistant penicillin derivatives. Pcase immobilized on cellulose filter membrane with $H^{+}$-selective PVC membrane eletrode was more stable and more sensitive to penicillinase-resistant penicillin derivatives than any other immobilization techniques.

  • PDF

Design of RC Plates and Shells subjected to Membrance Force and Flexural Moment (철근콘크리트 판형과 쉘의 휨과 막력을 고려한 설계)

  • 조홍진;민창식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.217-222
    • /
    • 2000
  • An iterative numerical computational algorithm is presented to design a plate or shell element subjected to membrance and flexural forces. Based on equilibrium consideration, equation for capacity of top and bottom reinforcements in two orthogonal directions have been derived. The amount of reinforcement is determined locally, I. e., for each integration point, from the equilibrium between applied and internal forces. Three cases of design are performed for slab element (used by Marti(1987)) and shell element (used by Kirscher and Collins(1986), by Polak and Vecchio(1993)) to verify the adequacy of the present design method for reinforced concrete shells. Based on nonlinear analyses performed, the analytically calculated ultimate load exceeded the design ultimate load. This shows the adequacy of the design method present in this study at least for slab and shell element case studied. To generalize the conclusion more design-analyses should be performed with different shell configurations.

  • PDF