• Title/Summary/Keyword: Medium pressure UV lamp

Search Result 16, Processing Time 0.026 seconds

Assessment of Advanced Oxidation Processes using Low and Medium-Pressure Lamps with H2O2 for Reclamation of Biologically Treated Wastewater Effluents (하수 2차 처리수 재이용을 위한 저압 및 중압 고도산화시스템의 성능평가)

  • Ahn, Kyu-Hong;An, Seok;Maeng, Seung-Kyu;Kim, Ki-Pal;Hong, Joon-Seok;Jung, Min-Woo;Kweon, Ji-Hyang;Ahmed, Zubair
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.542-549
    • /
    • 2003
  • In the present study, the feasibility of $UV/H_2O_2$ systems was investigated using low and medium-pressure lamps on biologically treated wastewater effluents for secondary effluent reclamation. Two types of UV lamps were used as the light sources (a 39-W low-pressure mercury lamp and a 350-W medium-pressure mercury lamp). The results from these UV systems showed that the removal of organic compounds could be achieved in the contact time of longer than 30min (i.e., low UV doses). Efficiencies of color removal and disinfection were far better than those of organic matters measured as TOC, DOC and $TCOD_{cr}$. In the low-pressure lamp UV system, it has been found that DOC and color removals were 60.9 and 86.2% with 50mg/L of $H_2O_2$ and contact times of 30 minute, respectively. Whereas, with the medium-pressure lamp UV system, TOC, DOC and color removal were 27.1, 5.6 and 95% with 14.3mg/L of $H_2O_2$ and 14 minute of contact times, respectively. Both systems could be applied for the reclamation of secondary effluent treated with biological treatment processes.

Development of an Ultra-Violet Lamp and a Ballast for Ship's Ballast Water Treatment (선박평형수 처리용 자외선 램프 및 안정기 개발)

  • Cheon, Sang-Gyu;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.675-681
    • /
    • 2011
  • In this paper, we dealt with the design and fabrication of a medium pressure ultra-violet (UV) lamp and a magnetic ballast which are main components for ballast water treatment systems (BWTS). To acquire an optimal discharge condition of UV lamp, electrical and optical characteristics depending on the argon gas volume and the amount of mercury were experimentally analyzed. Rated voltage, current and power consumption of a prototype lamp were 490 [V], 8.6 [A] and 4.0 [kW], respectively. UV intensity of the lamp was 15 [%] higher than that of an equivalent lamp which is used in a BWTS. The magnetic ballast was designed in a UI core type through theoretical analysis and simulation. The open voltage and the rated power consumption of the ballast were 920 [V] and 8.5 [kVA] respectively. The disinfection efficacy which is carried out in a BWTS equipped with the UV lamp and magnetic ballast was over 99.99 [%], and this satisfy the IMO regulations.

Disinfection Efficiency of Medium Pressure UV Lamp on Major Bacteria in Sand Filtered Water (사여과수에 존재하는 우점세균의 중압 자외선 램프 소독능)

  • Ahn, Seoung-Koo;Yang, Yoon-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.12
    • /
    • pp.1141-1146
    • /
    • 2010
  • Isolated the heterotrophic aerobic bacteria in sandfiltered water on NA and TSBA solid medium, selected 8 dominant species and identified by Sherlock System. Each samples are irradiated 0, 5, 16, 40 and $60\;mJ/cm^2$ using on CBD (Collimated Beam Device) Medium Pressure UV lamp after these identified bacterium did liquid culture how to make $10^6{\sim}10^7\;cells/mL$ suspended in dilution water. Then cultured bacteria are estimated inactivation rate on plate media. Identified Gram positive group are Bacillus Subtilus, Bacillus megaterium, Rhodococcus erythropolis and Microbacterium laevaniformans; Gram negative group are Pseudomonas vesicularis, Pseudomonas pseudoflava, Alcaligenes paradoxus and Zooglea ramigera. These isolation of bacterium are more stronger reference strain and high resistance of MP UV irradiation, Besides Gram negative bacterium are more sensitive Gram positive bacterium on MP UV dose. Now we are estimating to $60{\sim}100\;mJ/cm^2$ MP UV dose for efficient disinfection in water treatment plant.

Removal of Tetracycline Antibiotics Using UV and UV/H2O2 Systems in Water (UV 및 UV/H2O2 시스템을 이용한 수중의 Tetracycline계 항생물질 제거)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Jang, Seong-Ho;Kim, Han-Soo;Hong, Soon-Heon;Park, Woo-Sik;Song, Young-Chae
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1359-1366
    • /
    • 2014
  • Seven tetracycline classes of antibiotics were treated using ultraviolet (UV) and $UV/H_2O_2$ oxidation. Two different UV lamps were used for the UV and $UV/H_2O_2$ oxidation. The performance of the UV oxidation was different depending on the lamp type. The medium pressure lamp showed better performance than the low pressure lamp. Combining the low pressure lamp with hydrogen peroxide ($H_2O_2$) improved the removal performance substantially. The by-products formation of tetracycline by UV and $UV/H_2O_2$ were investigated. The protonated form ($[1+H]^+$) of tetracycline was m/z 445, reacted to yield almost exclusively two oxidation by-products by UV and $UV/H_2O_2$ oxidation. Their protonated forms of by-products were m/z 461 and m/z 477. The structures of tetracycline's by-products in UV and $UV/H_2O_2$ system were similar.

A Study on the Development of an Energy Saving Ballast Water Treatment Device (I) (에너지 절감형 평형수 처리장치 개발에 관한 연구 (I))

  • Park, Dae-Won;Kil, Gyung-Suk;Choi, Yong-Ki;Choi, Chul-Young;Chang, Ji-Ho;Cheon, Sang-Gyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.880-886
    • /
    • 2010
  • In this paper, we studied the application of low pressure ultra-violet (UV) lamps for the development of an energy saving ship's ballast water treat (BWT) device. We proposed the optimal arrangement of UV lamps by analyzing the energy radiated from medium- and low-pressure UV lamps. Based on the experimental results, we manufactured a disinfection chamber which is composed of low-pressure UV lamps. The rated power and the treatment capacity of the chamber are 216 [W] and 10 [$m^3$/h], respectively. This can replace a disinfection chamber treated by two 2 [kW] medium pressure lamps. The disinfection performance, however the power consumption is about one-eighteen compare to the medium pressure UV lamp, is over 94 [%] for bacteria, 93 [%] for zooplankton, and 94 [%] for phytoplankton. Therefore, it would be possible to develop an energy saving BWT device in a low capacity below 100 [$m^3$/h].

Removal of Total Organic Carbon and Micropollutants in Tertiary Treated Sewage by Medium Pressure UV/H2O2 (중압 자외선과 과산화수소 공정을 이용한 하수 3차 처리수중 총유기탄소와 미량오염물질 제거)

  • Lee, Jai-Yeop;Kim, Ilho
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.4
    • /
    • pp.314-321
    • /
    • 2020
  • This study evaluated the applicability of UV-AOP process using medium-pressure UV lamp and H2O2 to remove TOC and emerging micropollutants in the effluent from a sewage treatment plant. The UV lamp with higher output(1.6~8.0 kW) showed slightly higher amount of power in removing TOC of 1 mg/L(0.09 kWh/mg/L~0.11 kWh/mg/L), however it was found that there was no significant difference for each cases. In addition, under the condition that the H2O2 concentration is sufficient, as the power consumption of the UV lamp increases, the unit TOC removal concentration per unit H2O2 decomposition concentration also increases, resulting in effective removal of TOC. The removal rate of 7 new trace contaminants, such as antibiotics by the UV-AOP tested, was at least 89.4%, and the ability to remove the emerging micro pollutants in the process was very effective. But, it was judged that it could not be excluded that the probablity of transforming to oxidated by-product in the case of a low TOC removal efficiency. Depending on the operating conditions of the UV and H2O2 processes, a higher BOD concentration is found in the treated water than in the influent, and it is necessary to review the UV power and proper injection conditions of H2O2 to maintain the BOD concentration increase below a certain level.

Behavior of Organic Matter, Chlorine Residual and Disinfection By-Products (DBPs) Formation during UV Treatment of Wastewater Treatment Plant Effluents (하수처리장 방류수의 UV 처리시 유기물질, 잔류염소 및 소독부산물 생성 거동)

  • Han, Jihee;Sohn, Jinsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.1
    • /
    • pp.61-72
    • /
    • 2014
  • Study on effluent organic matter (EfOM) characteristic and removal efficiency is required, because EfOM is important in regard to the stability of effluents reuse, quality issues of artificial recharge and water conservation of aqueous system. UV technology is widely used in wastewater treatment. Many reports have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on EfOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics. The high intensity of pulsed UV would mineralize EfOM itself as well as change the characteristics of EfOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of EfOM. The objective of this study is to investigate the effect on EfOM, chlorine residual, and chlorinated DBPs formation with low pressure and pulsed UV treatment. The removal of organic matter through low pressure UV treatment is insignificant effect. Pulsed UV treatment effectively removes/transforms EfOM. As a result, the chlorine consumption is changed and chlorine DBPs formation is decreased. However, excessive UV treatment caused problems of increasing chlorine consumption and generating unknown by-products.

Behavior of Natural Organic Matter(NOM), Chlorine Residual, and Disinfection By-Products(DBPs) Formation in Pulsed UV Treated Water (Pulsed UV 처리수에서의 자연유기물질, 잔류염소 및 소독부산물 생성 거동)

  • Sohn, Jinsik;Han, Jihee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.5
    • /
    • pp.685-692
    • /
    • 2012
  • UV technology is widely used in water and wastewater treatment. Many researches have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on NOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics such as NOM. Pulsed UV treatment using UV flash lamp can be operated in the pulsed mode with much greater peak intensity. The pulse duration is typically in microseconds, whereas the interval between pulses is in the order of milliseconds. The high intensity of pulsed UV would mineralize NOM itself as well as change the characteristics of NOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of NOM. The objective of this study is to investigate the effect on NOM, chlorine residual, and chlorinated DBPs formation with pulsed UV treatment.

Investigation of Potential Photoreactivation of Pseudomonas aeruginosa after LP or MP UV Irradiation (저압 및 중압 자외선 조사에 의해 불활성화된 Pseudomonas aeruginosa의 광회복능 조사)

  • Mun, Sung-Min;Cho, Min;Yoon, Je-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.5
    • /
    • pp.755-761
    • /
    • 2006
  • Recently, there is growing interest in ultraviolet (UV) irradiation as a disinfection technic in drinking water production due to its effectiveness to inactivate microorganisms such as Crytosporidium parvum without forming disinfection byproducts. However, UV disinfection is known for its drawback such as photoreactivation. Despite many works concerning the photoreactivation, most of works were focused on indicator or non pathogenic microorganisms. The objective of this study is to examine the photoreactivation of Pseudomonas aeruginosa which is an opportunistic pathogen as UV radiation by LP and MP UV lamp was applied. The result showed that P. aeruginosa had high photo repair efficiency regardless of the type of UV irradiation. Both of the effective log repair values of LP and MP UV irradiation were found approximately 2.6 log. In addition, photo repaired P. aeruginosa was not significantly different in forming biofilm in comparison with non treated P. aeruginosa.