• 제목/요약/키워드: Medium power system

검색결과 501건 처리시간 0.024초

스프레이 열전달을 이용한 저온도차 스털링 엔진의 고온수 공급 유량 및 온도에 따른 기계 부하성능 실험 (Mechanical Load Performance Measurements of a Low Temperature Differential Stirling Engine with Water-Sprayed Heat Transfer according to Supply Water Flow Rates and Temperatures)

  • 심규호;정민성;이윤표;장선준
    • 한국유체기계학회 논문집
    • /
    • 제18권1호
    • /
    • pp.29-36
    • /
    • 2015
  • Recently, Stirling engines are emerging as a key device for power conversion of renewable energy or waste energy. This study develops a LTDSE(Low Temperature Differential Stirling Engine) using a water spray for higher heat transfer and performs load performance tests for various flow rates and temperatures of hot water spray for variable engine loads emulated by a mechanical friction device. Internal temperature and pressure, working frequency and inlet and outlet temperature of the supply water are measured. As a result, the increases in flow rate and temperature of hot water respectively enhance the power output, efficiency and the working frequency, while the increasing engine load leads to decreases in working frequency but increases in the pressure amplitude. Eventually, it is revealed there exists a maximum shaft power of the test engine.

프로젝트 정보관리체계 분석을 통한 중소건설업체 프로젝트 정보관리시스템 모델 제안 (Suggestion of Project Information Management System for Small & Medium Sized Construction Companies through Analysis of Information Management Structure)

  • 이태식;구자경;이상엽;김영현
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2003년도 학술대회지
    • /
    • pp.549-552
    • /
    • 2003
  • 중소건설업체는 열악한 경영상태 전문인력 부족, 기술력 부족 등의 여러 문제로 인해 그 기반이 매우 취약하다. 이린 상황에서 IMF 이후 대형건설업체들의 수주난과 경영 악화는 대형건설업체의 하도급을 수행하는 중소건설업체에도 전가됐으며, 이에 중소건설업체의 생존을 위한 전반적인 변화와 정보기술 도입을 통한 경쟁력 확보가 요구되고 있다. 본 연구는 중소건설업체의 프로젝트 관리방안 측면에서 중소건설업체의 특성과 기존 대형건설업체 및 상용 SI업체에서 개발한 정보관리 시스템을 분석하여 중소건설업체를 위한 프로젝트 정보관리체계를 구축하고 이를 관리하는 지원시스템 모델을 제안하고자 한다. 이를 통해 중소건설업체의 프로젝트 정보관리 능력을 향상 및 생산성 향상을 통한 경쟁력을 확보할 수 있을 것으로 예상된다.

  • PDF

중저속 이동체환경에서의 MIMO시스템 기반 안테나 선택과 전력할당 성능분석 (Performance Analysis for MIMO Multiuser Systems considering Selection of Transmit Antennas, Constellations and Powers in Low-to-medium Mobile Speed)

  • 유현;김진수;김종기;서명석;곽경섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.776-781
    • /
    • 2005
  • 본 논문은 수신된 채널 정보를 이용하여 각 사용자의 성상도와 전력, 송신 안테나를 선택함으로써 중저속 이동체를 위한 환경에서의 MIMO 다중 사용자 시스템에서 성능을 분석한다. 각 사용자의 성상도와 전력, 선택되는 송신 안테나는 주어진 목표 심벌 에러 확률에서 각 사용자의 정보량과 채널의 추정 정보에 따라 MMSE, V-Blast 수신기에서 요구되는 SNR이 최소화 되도록 결정한다. 또한 중저속 이동체 환경에서의 MIMO 시스템의 상향링크 채널을 통해 기지국으로부터 유저들에게 전송하는 무선 채널 정보를 안테나 선택기법으로 전력제어를 할 때 시스템 성능을 분석한다. 모의실험을 통해, 송신 안테나를 모두 사용하여 데이터를 전송하는 것보다 선택 알고리즘을 사용하여 데이터를 전송하는 것이 독립 페이딩 채널뿐만 아니라 상관 채널에서도 상당한 성능 개선이 있음을 확인 할 수 있었다.

  • PDF

Bulk Type Optical Sensor를 이용한 MV급 GIS의 전압.전류 측정 (Measurements of Voltage & Current from MV Class GIS Using a Bulk Type Optical Sensor)

  • 박정남;이석원;김영근;이한신;김영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1658-1660
    • /
    • 2004
  • Use of higher voltage and higher capacity of power systems and their equipment is leading to an increase in the size of the entire system. In order to reduce the cost of constructing a substation, it is necessary to reduce the size of equipment. So, this paper described optical sensor, which exploited the electric and magnetic potentiometer to sense the measured voltage and current of medium voltage GIS. It can be used both in measurement and in protection relays as its well linearity, rapid response, broad dynamic range, wide frequency band, no magnetic saturation, small in volume, light weight, and saft in insulation.

  • PDF

CONTROL STRATEGY OF ELECTRIC COOLANT PUMPS FOR FUEL ECONOMY IMPROVEMENT

  • CHO H.;JUNG D.;ASSANIS D. N.
    • International Journal of Automotive Technology
    • /
    • 제6권3호
    • /
    • pp.269-275
    • /
    • 2005
  • The engine cooling system for a medium duty V6, 4.5 L diesel engine was modeled with a commercial code, GT-Cool in order to investigate the effect of controllable electric pump on the cooling performance and the fuel economy. The simulation results of the cooling system model with mechanical coolant pump were validated with experimental data. Two different types of electric pumps were implemented into the cooling system model and PID control for electric pump operation was incorporated into the simulation study. Based on the simulation result with electric pump, conventional thermostat hysteresis was modified to reduce pump operation for additional improvement of fuel economy, and then the benefit of electric pumps with modified thermostat hysteresis on fuel economy was demonstrated with the simulation. The predicted result indicates that the cooling system with electric pump and modified thermostat hysteresis can reduce pump power consumption by more than $99\%$ during the FTP 74 driving cycle.

3상 SRM 구동용 4-스위치 인버터 PWM 제어 알고리즘 (Control Algorithm for 4-Switch Inverter of 3-Phase SRM)

  • 윤용호;이병국;원충연
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.303-309
    • /
    • 2009
  • Switched Reluctance Motor(SRM) has become popular for industrial application, particularly for low medium drives due to the advantages of SRM over the other ac motors: SRM can be manufactured with low cost because it has a simple structure. But, asymmetric bridge converter that generally is used for driving requires two discrete switching devices and freewheeling diodes per phase, and cause the SRM drives to be complicated and to increase the cost of overall system. Therefore, this paper suggests a new type of 4-switch converter for SRM. 4-switch converter topology is studied to provide a possibility for the realization of low cost 3-phase SRM drive system. For effective utilization of the developed system, a new current control algorithm is designed and implemented to produce the desired dynamic performance. With the developed power conversion circuit and control scheme, it is expected that the proposed system can be widely used in commercial applications with reduced system cost.

원자력발전소 배관 내부 매질이 초음파검사에 미치는 영향 평가 (Evaluation on the Effect of Ultrasonic Testing due to Internal Medium of Pipe in Nuclear Power Plant)

  • 윤병식;김용식;양승한
    • 한국압력기기공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.25-30
    • /
    • 2013
  • The periodic inspection of piping and pressure vessels welds in nuclear power plant has to provide reliable result related to weld flaws, such as location, maximum amplitude response, ultrasonic length, height and finally the nature or flaw pattern. The founded flaw in ultrasonic inspection is accepted or rejected based on these data. Specially, the amplitude of flaw response is used as basic parameter for flaw sizing and it may cause some deviation in length sizing result. Currently the ultrasonic inspections in nuclear power plant components are performed by specific inspection procedure which describing inspection technique include inspection system, calibration methodology and flaw characterizing. To perform ultrasonic inspection during in-service inspection, reference gain should be established before starting ultrasonic inspection by the requirement of ASME code. This reference gain used as basic criteria to evaluate flaw sizing. Sometimes, a little difference in establishing reference gain between calibration and field condition can lead to deviation in flaw sizing. Due to this difference, the inspection result may cause flaw sizing error. Therefore, the objective of this study is to compare and evaluate the ultrasonic amplitude difference between air filled and water filled pipe in nuclear power plant. Additionally, the accuracy of flaw sizing is estimated by comparing both conditions.

Implementation of a 35KVA Converter Base on the 3-Phase 4-Wire STATCOMs for Medium Voltage Unbalanced Systems

  • Karimi, Mohammad Hadi;Zamani, Hassan;Kanzi, Khalil;Farahani, Qasem Vasheghani
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.877-883
    • /
    • 2013
  • This paper discussed a transformer-less shunt static synchronous compensator (STATCOM) with consideration of the following aspects: fast compensation of the reactive power, harmonic cancelation and reducing the unbalancing of the 3-phase source side currents. The STATCOM control algorithm is based on the theory of instantaneous reactive power (P-Q theory). A self charging technique is proposed to regulate the dc capacitor voltage at a desired level with the use of a PI controller. In order to regulate the DC link voltage, an off-line Genetic Algorithm (GA) is used to tune the coefficients of the PI controller. This algorithm arranged these coefficients while considering the importance of three factors in the DC link voltage response: overshoot, settling time and rising time. For this investigation, the entire system including the STATCOM, network, harmonics and unbalancing load are simulated in MATLAB/SIMULINK. After that, a 35KVA STATCOM laboratory setup test including two parallel converter modules is designed and the control algorithm is executed on a TMS320F2812 controller platform.

A Zero Sequence Voltage Injection Method for Cascaded H-bridge D-STATCOM

  • Yarlagadda, Srinivasa Rao;Pathak, Mukesh Kumar
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1088-1096
    • /
    • 2017
  • Load variations on a distribution line result in voltage fluctuations at the point of common coupling (PCC). In order to keep the magnitude of the PCC voltage constant at its rated value and obtain zero voltage regulation (ZVR), a D-STATCOM is installed for voltage correction. Moreover, the ZVR mode of a D-STATCOM can also be used to balance the source current during unbalanced loading. For medium voltage and high power applications, a D-STATCOM is realized by the cascaded H-bridge topology. In the ZVR mode, the D-STATCOM may draw unbalanced current and in this process is required to handle different phase powers leading to deviations in the cluster voltages. Zero sequence voltage needs to be injected for ZVR mode, which creates circulating power among the phases of the D-STATCOM. The computed zero sequence voltage and the individual DC capacitor balancing controller help the DC cluster voltage follow the reference voltage. The effectiveness of the control scheme is verified by modeling the system in MATLAB/SIMULINK. The obtained simulations are further validated by the experimental results using a dSPACE DS1106 and five-level D-STATCOM experimental set up.

하이브리드 모델을 이용하여 중단기 태양발전량 예측 (Mid- and Short-term Power Generation Forecasting using Hybrid Model)

  • 손남례
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.715-724
    • /
    • 2023
  • Solar energy forecasting is essential for (1) power system planning, management, and operation, requiring accurate predictions. It is crucial for (2) ensuring a continuous and sustainable power supply to customers and (3) optimizing the operation and control of renewable energy systems and the electricity market. Recently, research has been focusing on developing solar energy forecasting models that can provide daily plans for power usage and production and be verified in the electricity market. In these prediction models, various data, including solar energy generation and climate data, are chosen to be utilized in the forecasting process. The most commonly used climate data (such as temperature, relative humidity, precipitation, solar radiation, and wind speed) significantly influence the fluctuations in solar energy generation based on weather conditions. Therefore, this paper proposes a hybrid forecasting model by combining the strengths of the Prophet model and the GRU model, which exhibits excellent predictive performance. The forecasting periods for solar energy generation are tested in short-term (2 days, 7 days) and medium-term (15 days, 30 days) scenarios. The experimental results demonstrate that the proposed approach outperforms the conventional Prophet model by more than twice in terms of Root Mean Square Error (RMSE) and surpasses the modified GRU model by more than 1.5 times, showcasing superior performance.