• Title/Summary/Keyword: Medium capacity

Search Result 897, Processing Time 0.022 seconds

Numerical study on the moment capacity of zed-section purlins under uplift loading

  • Zhu, Jue;Chen, Jian-Kang;Ren, Chong
    • Structural Engineering and Mechanics
    • /
    • v.49 no.2
    • /
    • pp.147-161
    • /
    • 2014
  • In this paper a nonlinear finite element analysis model is established for cold-formed steel zed-section purlins subjected to uplift loading. In the model, the lateral and rotational restraints provided by the sheeting to the purlin are simplified as a lateral rigid restraint imposed at the upper flange-web junction and a rotational spring restraint applied at the mid of the upper flange where the sheeting is fixed. The analyses are performed by considering both geometrical and material nonlinearities. The influences of the rotational spring stiffness and initial geometrical imperfections on the uplift loading capacity of the purlin are investigated numerically. It is found that the rotational spring stiffness has significant influence on the purlin performance. However, the influence of the initial geometric imperfections on the purlin performance is found only in purlins of medium or long length with no or low rotational spring stiffness.

Lithium-ion Stationary Battery Capacity Sizing Formula for the Establishment of Industrial Design Standard

  • Chang, Choong-koo;Sulley, Mumuni
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2561-2567
    • /
    • 2018
  • The extension of DC battery backup time in the DC power supply system of nuclear power plants (NPPs) remains a challenge. The lead-acid battery is the most popular at present. And it is generally the most popular energy storage device. However, extension of backup time requires too much space. The lithium-ion battery has high energy density and advanced gravimetric and volumetric properties. The aim of this paper is development of the sizing formula of stationary lithium-ion batteries. The ongoing research activities and related industrial standards for stationary lithium-ion batteries are reviewed. Then, the lithium-ion battery sizing calculation formular is proposed for the establishment of industrial design standard which is essential for the design of stationary batteries of nuclear power plants. An example of calculating the lithium-ion battery capacity for a medium voltage UPS is presented.

A Study to keep the Concrete Quality when pouring concurrently the Concrete with Different Mixing Ratio - Based on Gunsan D Project (배합비가 상이한 콘크리트의 혼합 타설시 품질확보에 관한 연구 -군산 D PROJECT를 중심으로-)

  • Kim, Kyung-Hoon;Lee, Sang-Hak
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.82-83
    • /
    • 2017
  • The samll-medium sized cities do not have enough infrastructure for the construction work, especially in terms of concrete supply. This research surveyed the capacity of remicon companies in Gunsan related with production and delivery. Their production capacity is bigger than the daily quantity required, however the delivery capacity is not enough to supply the daily quantity required and it is inevitable to use the several remicon using different admixture. It might cause the harm to the structure. This research studied the way to remove the quality risk when using different admixture at the same time.

  • PDF

Experience for development and capacity certification of safely relief valves (안전방출밸브 개발과 용량인증 사례)

  • Kim, Chil-Seong;No, Hui-Seon;Kim, Gang-Tae;Kim, Ji-Heon;Kim, Jong-Su
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.492-500
    • /
    • 2004
  • The purpose of this study is localization of safety relief valves fur Nuclear Service through technical development with overall design, fabrication, inspection, capacity certification test and functional qualification test of safety relief valves in accordance with KEPIC MN Code(or ASME Sec.III ). The safely relief valve is the important equipment used to protect the pressure vessel, the steam generator and the other pressure facility from overpressure by discharging the operating medium when the pressure of system is reaching the design pressure of the system. But we're depending on technology of the other country up to the present time. Because we don't have our own technologies, we have been spent the great time and money on installing and repairing safety relief valve at nuclear power plant. Therefore we have to achieve the development of safety relief valves for Nuclear Service with our own technologies.

  • PDF

Bearing Capacity of a Square Shallow Foundation with and without Geogrid Reinforcement (Geogrid보강 여부에 따른 정방형 얕은 기초의 지지력에 관한 연구)

  • 신방웅;김수삼
    • Geotechnical Engineering
    • /
    • v.10 no.3
    • /
    • pp.5-16
    • /
    • 1994
  • This paper presents a new method to improve the bearing capacity of a square shallow foundation placed on a sand layer reinforced with geogrids which shows promise for further field work. The geogrid reinforcement will be necessary in the case of machine foundation, embankments for railroads, and foundations of structures in earthquake-prone areas. The ultimate bearing capacity (UBC) for the unreinforced sand and reinforced sand has been compared. Also, the effect of length, spacing, width of reinforcement on increasing the UBC have been evaluated. Based on the present model test results, it appears that significant improvement in the UBC of medium sand can be achieved by geogrid reinforcement.

  • PDF

Studies on Performance of CO2 Water Heater by Numerical Modeling (수치적 모델링을 통한 이산화탄소 급탕기의 특성 연구)

  • Park, Han Vit;Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.20-27
    • /
    • 2013
  • Numerical modeling of $CO_2$ water heater was conducted prior to optimal design of medium and large sized $CO_2$ water heater, and the experimental test with small sized $CO_2$ water heater having heat capacity of 4 kW was completed to verify the present numerical model. The present model estimated the experimental data of COP(coefficient of performance), heating capacity, and the hot water outlet temperature within the range of 3% to 8% of mean deviation. As increase of EEV(electric expansion valve) opening area, decreasing of heating capacity and the hot water outlet temperature, and increasing of COP were found in both experimental and numerical investigation.

The Role of Technology-Transfer-Oriented Subsidies in Building Companies' Absorptive Capacity and Innovation: Evidence from Peruvian MSMEs

  • Maria Fernanda Ricalde-Chahua;Christian Fernando Libaque-Saenz
    • Asia pacific journal of information systems
    • /
    • v.33 no.2
    • /
    • pp.444-467
    • /
    • 2023
  • Micro, small, and medium-sized enterprises (MSMEs) have been acknowledged to play a key role in promoting innovation and economic development. In Peru, 99.5% of formal firms are MSMEs, thus promoting innovation in these firms could have a significant impact on the Peruvian economy. In spite of Innovate Peru's efforts, Peru is still one of the countries that invests the least in innovation, with MSMEs offering low value added. Innovate Peru has launched programs (technological missions) to improve MSMEs' innovation through technology-transfer-oriented subsidies, which may strengthen companies' absorptive capacity (AC) and thus their capabilities to identify and integrate internal and external knowledge. This study assesses the impact of these programs on MSMEs. Data were collected from 85 MSMEs that participated in Innovate Peru's technological missions between 2014 and 2016. Findings show that all the dimensions of AC have a positive impact on innovation; however, the impact of economic subsidy was found to be non-significant. Theoretical and practical implications are discussed.

DEVELOPMENT AND TESTING OF MEDIUM CAPACITY GRAIN FLOUR SEPARATOR

  • Kachru, Rajinder-P
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.966-978
    • /
    • 1993
  • A power operated 90.5 hp electric motor) grain flour separator was designed and developed for separation of grain (wheat, corn, chickpea and soybean) flour into various fractions based on the size of the particles of the product. The separator agitating mechanism, feed control, cylindrical separator unit and an eccentric mechanism. The machine was tested for wheat ( variety ; Sujata) flour separation into four fractions, viz ; semolina, Gr-I and II, flour (coarse) and white (fine) flour. Wheat samples (6.8% m.c., db) were first pearled by CIAE pearler for 15.8% bran removal . The pearled wheat grains were then milled for semolina by a burre mill. The product and machine characteristics were determined at different capacities varying from 24 kg/h to 143 kg/h. It was found that 76 kg/h capacity gave reasonably best results in terms of purity and recovery of semolina vis-a-vis the market product. The energy requirement of the machine at no-load was found to be 230 W and at load c nditions, it varied between 36.3-6.4 KJ per kg of fead seperation. The macine could be used by small flour millers small/medium size traders and retailers and other processors for making available various flour products of different particle size in the market for ready use of the consumers.

  • PDF

The Economic Comparison of EHP and GHP for Medium Capacity Air-conditioning (중용량 공조에서 EHP와 GHP의 경제성 비교)

  • Kim, Young-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.167-174
    • /
    • 2008
  • Cost related to building equipment accounts for about 85% of the life cycle cost of buildings. Therefore proper selection of air-conditioning system is important for reducing the overall cost of buildings. In this study, medium capacity EHP and GHP for air-conditioning a building with a floor area of 1,200 $m^2$ are compared economically. To consider all the factors of initial and operation costs effectively, an annual equal payment method is proposed. For the initial cost, cost of equipment, construction, installation, electric facility, financial subsidy and tax cut is considered. Cost of basic electricity, energy(electricity and gas), space charge, labor, insurance and repair is considered for the operation cost. Under the assumptions made in this study, overall cost of EHP is less than that of GHP, but this is not absolute and different outcome may result if different assumptions are made. This study is useful for those who are interested in choosing an air-conditioning system that costs less for mid-size buildings with simple calculations.

Effect of Incorporation Rate of Polyacrylamide Hydrogel on Changes in Physical Properties of Root Media (Polyacrylamide 고흡수성 수지의 혼합 비율이 상토의 물리성에 미치는 영향)

  • Wang, Hyun-Jin;Choi, Jong-Myung;Lee, Jong-Suk
    • Journal of Bio-Environment Control
    • /
    • v.14 no.3
    • /
    • pp.182-189
    • /
    • 2005
  • This research was conducted to determine physical properties of four root media, peatmoss + vermiculite (1:1, v/v; PV), peatmoss + composted rice hall (1:1, PR), peatmoss + composted saw-dust (1:1 : PS) and peatmoss + composted pine bark (1:1 PB), as influenced by incorporation rate of Stock-sorb C (STSB). Each root medium containing STSB was packed in 22 cm diameter plastic pot and the physical properties were determined at 5 weeks after packing. As incorporation rate of STSB were elevated, total porosity increased in PV, PS and PB media with statistical differences at $5{\%}$ level. Those also resulted in increase of container capacity in PS and PB media, but statistical differences were not observed in PV and PR media. Elevated incorporation rate of STSB in PV, PS and PB media resulted in increase of air space with statistical differences. Trends in air space of the three root media showed a linear as well as quadratic responses to STSB contents of media. As incorporation rate of STSB increased, more water was retained in four root media at the soil moisture tension of 4.90 kPa, 9.81 kPa, 29.4 kPa and 1.5 MPa. The amount of water retained in PS medium was the highest at the moisture tension at 29.4 kPa and 1.5 MPa followed by PB, PR and PV medium. These results indicated that elevation of incorporation rate of STSB to various root media increased moisture retention capacity, but did not increase the available water holding capacity.