• 제목/요약/키워드: Medium capacity

검색결과 895건 처리시간 0.037초

Utility Bounds of Joint Congestion and Medium Access Control for CSMA based Wireless Networks

  • Wang, Tao;Yao, Zheng;Zhang, Baoxian;Li, Cheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권1호
    • /
    • pp.193-214
    • /
    • 2017
  • In this paper, we study the problem of network utility maximization in a CSMA based multi-hop wireless network. Existing work in this aspect typically adopted continuous time Markov model for performance modelling, which fails to consider the channel conflict impact in actual CSMA networks. To maximize the utility of a CSMA based wireless network with channel conflict, in this paper, we first model its weighted network capacity (i.e., network capacity weighted by link queue length) and then propose a distributed link scheduling algorithm, called CSMA based Maximal-Weight Scheduling (C-MWS), to maximize the weighted network capacity. We derive the upper and lower bounds of network utility based on C-MWS. The derived bounds can help us to tune the C-MWS parameters for C-MWS to work in a distributed wireless network. Simulation results show that the joint optimization based on C-MWS can achieve near-optimal network utility when appropriate algorithm parameters are chosen and also show that the derived utility upper bound is very tight.

가변선단재하판을 이용한 양방향말뚝재하시험의 치수 효과 (A Scale-Effect of O-Cell Pile Load Test with Variable End Plate)

  • 주용선;김낙경;김웅진;박종식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.884-890
    • /
    • 2009
  • The bi-directional pile load test with variable end plate overcomes the shortcoming of the Osterberg cell test. It is possible that the ultimate bearing capacity of the bi-direction can be known by using the loading of the end plate and two step procedures. The first step is to confirming end bearing capacity with variable end plate and the second step is similar to the conventional O-cell test. In the study, To calculate ultimate capacity of bi-directional load test using model with the pile with variable end plate O-cell, operated with end plate of 3 type on sand layer according to the relative density, loose, medium and dense conditions.

  • PDF

Electrochemical Properties of Binary Electrolytes for Lithium-sulfur Batteries

  • Kim, Hyung-Sun;Jeong, Chang-Sik
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권10호
    • /
    • pp.3682-3686
    • /
    • 2011
  • The electrochemical properties of lithium-sulfur batteries with binary electrolytes based on DME and DOL, TEGDME and DOL mixed solvent containing $LiClO_4$, LiTFSI, and LiTF salts were investigated. The ionic conductivity of 1M LiTFSI and $LiClO_4$ electrolytes based on TEGDME and DOL increased as the volume ratio of DOL solvent increased, because DOL effectively reduces the viscosity of the above electrolytes medium under the same salts concentration. The first discharge capacity of lithium-sulfur batteries in the DME and DOL-based electrolyte followed this order: LiTFSI (1,000 mAh/g) > LiTF (850 mAh/g) > $LiClO_4$ (750 mAh/g). In case of the electrolyte based on TEGDME and DOL, the first discharge capacity of batteries followed this order: $LiClO_4$ (1,030 mAh/g) > LiTF (770 mAh/g) > LiTFSI (750 mAh/g). The cyclic efficiency of lithium-sulfur batteries at 1M $LiClO_4$ electrolytes is higher than that of batteries at other lithium salts-based electrolytes. Lithium-sulfur battery showed discharge capacity of 550 mAh/g until 20 cycles at all electrolytes based on DME and DOL solvent. By contrast, the discharge capacity of batteries was about 450 mAh/g at 1M LiTFSI and LiTF electrolytes based on TEGDME and DOL solvent after 20 cycles.

시스템 히트펌프의 용량조절 및 다변수 제어 특성에 관한 연구 (The Performance of Capacity Modulation and MIMO Control for System Heat Pump)

  • 송인식;주영주;정현준;강훈;김용찬;최종민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.364-369
    • /
    • 2007
  • A system heat pump provides the benefits of comfort, energy conservation and easy maintenance. Recently, the system heat pump has been employed in small and medium-sized buildings. However, the performance data and control algorithm for system heat pump are limited in literature due to complicated system parameters and operating conditions. In the present study, the performance of a system heat pump with two indoor unit is measured by varying indoor loads, EEV opening, and compressor speed. In addition, the integral optimum regulator which includes MIMO control algorithm is proposed. The capacity modulation and optimum capacity for each indoor unit can be adjusted by utilizing the EEVs opening and compressor speed. The proposed scheme shows appropriate control performance at test conditions.

  • PDF

돼지 난소내 여포의 폐쇄과정중 과립세포의 결합능의 변화 (Change of hCG Binding Capacity on the Granulosa Cell of Porcine Ovary During Follicular Atresia)

  • 장철수;이창주;윤용달;김문규
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제13권1호
    • /
    • pp.29-38
    • /
    • 1986
  • In order to study the mechanism of follicular atresia, follicles were classified into the normal groups and the atretic ones, according to the criteria with or without corpus luteum, size of follicles, vascularization, status of granulose cells and the hypertrophy of theca layers in the porcine ovary. To estimate the binding capacity of human chorionic gonadotropin (hCG) receptor on the granulosa cells during atresia, hCG were iodinated by the chloramine-T method and then purified through the column chromatography. The concentration" of hCG receptor in each group were measured by the hCG receptor binding assay. Binding capacity in large normal follicles were 1.16%, but atretic ones were 0.45%. But in medium and small follicles (below 6mm in diameter), the binding capacity in normal follicles were 0.09%, but atretic ones were 0.05%, which was lower than those of large follicles. The present ( ) that the concentrations of hCG receptors on granulosa cells is decreased when the follicles become atretic and be used as a sort of creteria for the identification of follicles atresia.

  • PDF

Bearing capacity of a Flysch rock mass from the characterization of the laboratory physical properties and the Osterberg test

  • Hernan Patino;Ruben A. Galindo
    • Computers and Concrete
    • /
    • 제33권5호
    • /
    • pp.573-594
    • /
    • 2024
  • This article presents a research study, with both laboratory and field tests, of a deep foundation in a markedly anisotropic medium. Particularly it has focused on the evaluation of the behavior of a pile, one meter in diameter, embedded in a rocky environment with difficult conditions, in the Flysch of the Spanish city of San Sebastián. To carry out the research, the site of a bridge over the Urumea River was chosen, which was supported by pre-excavated reinforced concrete piles. 4 borings were carried out, by the rotation and washing method, with continuous sampling and combined with flexible dilatometer tests. In the field, an Osterberg load test (O-cell) was performed, while in the laboratory, determinations of natural moisture, natural unit weight, uniaxial compressive strength (UCS), point load strength (PLS), compressive wave propagation velocity (Vc) and also triaxial and direct shear tests were carried out. The research results indicate the following: a) the empirical functions that correlate the UCS with the PLS are not always linear; b) for the studied Flysch it is possible to obtain empirical functions that correlate the UCS with the PLS and with the Vc; c) the bearing capacity of the studied Flysch is much greater than if it is evaluated by different load capacity theories; d) it is possible to propose an empirical function that allows evaluating the mobilized shear strength (τm), as a function of the UCS and the displacement relative of the pile (δr).

조직 메모리 제공과 개인-직무, 개인-조직 적합성이 조직성과에 미치는 영향 : 흡수역량을 매개로 (The Effect of Organizational Memory Affordance and Person-Job, Person-Organization Fit on Organizational Performances : Mediating Absorption Capacity)

  • 권재현;서영욱
    • 한국콘텐츠학회논문지
    • /
    • 제20권8호
    • /
    • pp.274-284
    • /
    • 2020
  • 4차 산업 혁명 시대에는 데이터의 효율적인 활용 수준이 그 기업의 성과에 큰 영향을 미친다. 본 연구는 조직 메모리 제공이 개인-직무 적합성과 개인-조직 적합성의 수준에 따라 조직성과에 미치는 영향을 흡수역량이 매개로 했을 때의 효과를 실증 분석하였다. 대기업, 중견기업, 중소기업 재직자 317명을 대상으로 설문데이터를 분석한 결과, 조직 메모리 제공이 충분한 조직은 개인-직무 및 개인-조직 적합성 모두 긍정적인 영향을 미쳤으며, 흡수역량도 긍정적인 영향을 미쳤다. 그리고 조직 메모리 제공은 개인-조직 적합성을 매개할 '때 흡수역량에 긍정적인 영향을 주는 것으로 확인되었다. 개인-직무 적합성과 개인-조직 적합성은 조직성과에 긍정적 영향을 미치나, 흡수역량을 매개할 경우는 개인-조직 적합만이 긍정적인 영향 관계가 나타났다. 본 연구는 흡수역량의 선행 요인으로 조직 IT 구축환경과 구성원들의 조직과 직무에 대한 인식을 종합적으로 분석하고, 조직성과에 미치는 영향을 동시에 실증함으로써 연구의 의의가 있다.

트레드밀 운동이 뇌졸중 환자의 폐기능과 보행능력에 미치는 효과 : 메타분석 (Effects of Treadmill Exercise on Pulmonary Function and Gait Capacity in Stroke Patients : A meta-analysis)

  • 조성현;최기복
    • 대한통합의학회지
    • /
    • 제8권2호
    • /
    • pp.169-185
    • /
    • 2020
  • Purpose : This study aimed to conduct a comprehensive meta-analysis to evaluate the effect size for pulmonary function and gait capacity of treadmill exercise in stroke patients. In addition, we aimed to examine the current status of treadmill interventions and compare the effect sizes of treadmill training to provide evidence-based practice for future development and application. Methods : The meta-analysis study was conducted using research articles that applied treadmill exercise to stroke patients and were published between January 2005 and February 2020. For a systematic meta-analysis, we conducted a search using the PICOS framework and selected 25 domestic stroke- and treadmill-related studies. The Comprehensive Meta-Analysis program was used to calculate the effect sizes for lung function and gait capacity (6-minute walk test and 10 m walk test). As Cohen's d has a tendency to overestimate the effect size, we used Hedge's g to increase the accuracy in computing the effect size. Results : Based on the results of the meta-analysis, the total effect size of treadmill exercise was 0.535, which was statistically significant, with a medium effect size (p<0.05). The effects of treadmill exercise in stroke patients were divided into dependent variables, namely pulmonary function (0.372) and gait capacity (0.584). In addition, for gait capacity, the effect sizes were evaluated for both the 6-minute walk test (0.756) and the 10 m walk test (0.514). Conclusion : This study provides objective evidence of the effectiveness of treadmill-based gait training programs. We hope that the results of this study will help support the development and implementation of treadmill-based gait training in stroke patients. Treadmill training is expected to improve not only pulmonary function, but also the gait capacity of stroke patients. Long-term investigations on the effects of treadmill training in stroke patients are necessary.

동결농축법을 이용한 폐수처리시스템의 에너지 효율 향상에 관한 연구 (A study on energy efficiency improvement of waste-water treatment system by freeze concentration method)

  • 김정식;임승택;오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.467-476
    • /
    • 2013
  • 동결농축법은 열역학적 효율이 높고 에너지 소비량이 작으며 처리수를 재활용할 수 있는 장점을 가지고 있다. 본 연구에서는 중소규모로 상용화 가능한 동결농축폐수처리시스템을 설계하고, 각 시스템의 에너지 소비효율과 일일처리량을 비교하여 시스템 개발방향을 제안하고자 하였다. 시스템을 완속운전시스템과 급속운전시스템으로 각각 모델링하고 해석을 통해 소비동력과 운전시간을 계산하여 비교한 다음 설계처리량에 따른 변화를 추가 검토하였다. 연구결과 급속운전시스템의 소비전력량비가 0.6 Wh/kg 만큼 다소 높으나 일일처리량은 19 % 증가하였으며, 설계처리량이 큰 시스템일수록 소비전력량비가 작아지고 일일처리량이 큰 결과를 얻었다.

Assessment of cold-formed steel screwed beam-column conections: Experimental tests and numerical simulations

  • Merve Sagiroglu Maali;Mahyar Maali;Zhiyuan Fang;Krishanu Roy
    • Steel and Composite Structures
    • /
    • 제50권5호
    • /
    • pp.515-529
    • /
    • 2024
  • Cold-formed steel (CFS) is a popular choice for construction due to its low cost, durability, sustainability, resistance to high environmental and seismic pressures, and ease of installation. The beam-column connections in residential and medium-rise structures are formed using self-drilling screws that connect two CFS channel sections and a gusset plate. In order to increase the moment capacity of these CFS screwed beam-column connections, stiffeners are often placed on the web area of each single channel. However, there is limited literature on studying the effects of stiffeners on the moment capacity of CFS screwed beam-column connections. Hence, this paper proposes a new test approach for determining the moment capacity of CFS screwed beam-column couplings. This study describes an experimental test programme consisting of eight novel experimental tests. The effect of stiffeners, beam thickness, and gusset plate thickness on the structural behaviour of CFS screwed beam-column connections is investigated. Besides, nonlinear elasto-plastic finite element (FE) models were developed and validated against experimental test data. It found that there was reasonable agreement in terms of moment capacity and failure mode prediction. From the experimental and numerical investigation, it found that the increase in gusset plate or beam thickness and the use of stiffeners have no significant effect on the structural behaviour, moment capacity, or rotational capacity of joints exhibiting the same collapse behaviour; however, the capacity or energy absorption capacities have increased in joints whose failure behaviour varies with increasing thickness or using stiffeners. Besides, the thickness change has little impact on the initial stiffness.