• 제목/요약/키워드: Medium Filter

검색결과 274건 처리시간 0.026초

고속여과의 효과에 관한 연구 (Study of High Rate Filter.)

  • 박인규
    • 물과 미래
    • /
    • 제10권2호
    • /
    • pp.91-100
    • /
    • 1977
  • This is an experimental study to raise higher efficiency of filteration than conve ntional filteration by increasing of filteration capacity for per unit area and by extending of filteration lasting time with biflow filter system which was improved from the conventional rapid sand filteration method in the process of water purification treatment. In order to raise more efficient function of filteration and giving consideration to the filter layer at upper and lower parts of the filter, the fine sand & an thracite were used as a filter medium. Although there is some difficulty than previous fine sand in procurement, it could confirm that such filter medium (fine sand & anthracite) was more effective in the field of load, lasting time and back wash, etc. In consideration of practical effect of filteration. The raw water which was used for this experimental study was not coagulated. As a result of this experiment, the filteration volume could increase more than 2 times than that of conventional method. Besides, much more advantages could be obtained for instance, the requirement of installation area was not much and installation cost could economize. On the other hand, the following results were found. The quality of filtered water became worse as time goes by and the turbidity of filtered water was more influenced by raw water turbidity than by rate of filteration. Lasting time of filteration on change of filteration rate in the filter layer reached 2 times in comparison with previous filter basin, and until loss gead reached to 1.0 meter and 1.5 meter, the following relate formulas between lasting time and rate of filteration were formed. ($T_{1.5}=181.96V^{-0.46},\;T_{1.0}=121.31V^{-0.46}$) Even though the lasting time can be shorten in case of the increase of the filteration rate, but the lasting time was prolonged more than 2 times than of previous method. With taking aim at contribution to the development of water treatment technique, we are planning to study continuously for the future study basing on the results in this papers.

  • PDF

필터 조밀도의 영향에 의한 3단 필터 시스템의 유동특성 해석 (Analysis of Flow Characteristics of Triple Filter System by the Influence of Filter Density)

  • 손인수
    • 한국산업융합학회 논문집
    • /
    • 제26권6_2호
    • /
    • pp.1163-1169
    • /
    • 2023
  • In this study, the flow characteristics of the filter system were analyzed due to the effect of the density of the filter in the triple filter system. Flow analysis was performed as a flow passing through a porous medium. The flow characteristics of each filter system were analyzed by arranging filters with different densities in the forward flow flow and the reverse flow. The arrangement order of the triple filters was excellent in the case of forward fluid flow and in the case of higher density from the inside to the outside filter. In the reverse flow filter system, the performance of the system was the best in the case of reverse order filter arrangement. As a result of the analysis, Case II, which showed a pressure drop rate of 5.65% for forward flow, was the best in the reverse direction with a pressure drop rate of 14.25%. Considering reverse and forward flows, it was found that the optimal filter arrangement was most effective when the intermediate filter was the densest, and the inner or outer filter was less dense.

Filter membrane과 feeder세포를 이용한 벼의 원형질체 배양 (The Filter Membrane Culture Procedure with Feeder Cells in Rice Protoplast Culture)

  • LEE, Sung-Ho;SHON, Young Geol;Lee, Soo In;DAVEY Micheal R.;COCKING Edward C.;CHO, Moo Je
    • 식물조직배양학회지
    • /
    • 제24권5호
    • /
    • pp.295-303
    • /
    • 1997
  • Japonica 벼 품종 Taipei 309 성숙 종자의 배반에서 유도된 캘러스로부터 유기 시킨 세포 현탁 배양체에서 원형질체를 분리하여 filter membrane과 feeder 세포를 이용한 여러가지 조건에서 배양하였다. 이러한 조건들은 gelling agents, feeder 세포와 원형질체 밀도, feeder 세포의 종류 및 heat shock 처리 등이며 이들이 filter membrane 배양 방법에서 원형질체 평판 효율에 미치는 효과들을 조사하였다. 원형질체 평판 효율은, Lolium multiflorum을 feeder 세포로 사용하고 (10 mL의 원형질체 배양 배지당 0.5 mL pcv) 원형질체를 mL 당 $5\;\times\;10^{5}$개로 하여 Sea Plague agarose 배지에 원형질체를 배양 했을때 최고치를 얻었다. 원형질체에 heat shock 처리를 했을 때 원형질체 평판 효율은 변화가 없었다. carbohydrate source로서 sucrose로서 sucrose 대신에 maltose를 사용했을 때 식물체 재분화율이 높았으며 원형질체로부터 재분화된 이들 식물체들은 임성을 나타내었다.

  • PDF

광신호 에너지 최적화를 위한 IIR 격자형 광파이버필터 설계 (Optical IIR lattice fiber filter design for optimum of optical signal energy)

  • 이채욱;김신환
    • 전자공학회논문지B
    • /
    • 제32B권11호
    • /
    • pp.1481-1488
    • /
    • 1995
  • Due to the low loss, broadband and accurate short time delay properties of optical fiber, it has attracted as a delay medium for high speed and broad-band signal processing. In this paper, we consider the coherent optical fiber filter of IIR lattice structure, which uses coherent light sources and consists of directional couplers whose coupling coefficients are restricted between 0 and 1. Considering restrictions of directional coupler, the design formulae and condition for realibility of optical fiber filter of IIR lattice structure which makes the optimal use of optical signal energy are derived.

  • PDF

Filtration Efficiency of Electrically Charged Air Filters by a Corona Method

  • Murtadlo, Zainul Alim Ali;Joe, Yun-Haeng;Park, Seok-Hoon;Park, Hyun-Seol
    • 한국입자에어로졸학회지
    • /
    • 제15권1호
    • /
    • pp.15-25
    • /
    • 2019
  • The influences of corona charging parameters on collection efficiency and surface potential of air filters were investigated. A polypropylene filter medium was electrically charged using a corona charger, and the resulting surface potential and filtration efficiency against neutralized KCl particles were measured. The filter media was charged under different conditions of applied voltage, voltage polarity, charging time, and distance between electrodes. In addition, we considered charging both sides of the filter as well as charging one side of the filter. As a result, electrical force obtained by charged fiber affected filtration efficiency when the apply voltage strength was higher than 7 kV. Negatively charged filter had higher filtration efficiency than positively charged filter while the surface potential of the negatively charged filter was slightly lower than those of positively charged filter. Moreover, the filtration efficiency increased as the charging time of filter fiber increased and the distance between electrodes decreased. The filtration efficiency was more sensitive to changes of charging time than to those of electrode distance, and the efficiency of both sides charged filter was higher than that of single side charged filter.

제올라이트 칼럼에 의한 인공생활하수의 COD 및 BOD 제거에 관한 연구 (COD and BOD Removal of Artificial Municipal Wastewater by a Column filled with Zeolite)

  • 서정윤
    • 한국습지학회지
    • /
    • 제3권1호
    • /
    • pp.75-89
    • /
    • 2001
  • Constructed wetlands were typically cost less to build and operate, and require less energy than standard mechanical treatment technology but they have similar performance to centralized wastewater treatment plants. Therefore, they were constructed especially many in rural areas, where are small villages but not industries. Accordingly, plantless column tests were performed to investigate the possibility on using zeolite as a filter medium of constructed wetland for the wastewater treatment. $COD_{cr}$ removal efficiency was 94.63% at hydraulic load $314L/m^2{\cdot}d$ and filtering hight 100cm filled with a zeolite mixture. This zeolite mixture consisted of 1 : 1 by volume of a zeolite in the diameter range of 0.5 to 1mm to a zeolite in the diameter range of 1 to 3mm. According, hydraulic load $314L/m^2{\cdot}d$ was considered as optimal. Three zeolite mixture were used to determine the optimal mixing ratio by volume of a zeolite(A) in the diameter range of 0.5 to 1mm to a zeolite(B) in the diameter range of 1 to 3mm diameter. 1 : 3, 1 : 1 and only B in A to B by volume were tested at hydraulic load $314L/m^2{\cdot}d$ and filtering hight 100cm. $COD_{cr}$ removal efficiency was more than 89% at mixing ratios of 1 : 3 and 1 : 1 in A to B. Removal efficiency was lower at the column filled with only B. Removal efficiency was better at filter medium filled with mixing ratio 1 : 1 in A to B than with the other mixing ratios. Thus, it was found that the mixture of mixing ratio 1 : 1 in A to B was appropriate for filter medium of constructed wetland. Removal efficiency was higher in down-flow than in up-flow, and $COD_{cr}$ and BOD were removed best in 20cm filter height near feeding area.

  • PDF

측면 연마된 열확산 코어 광섬유와 외부 물질의 분산 특성 차이를 이용한 단파장 통과 필터 (A Short Wavelength Filter Based on Dissimilar Dispersive Property Between a Thermally Expanded Cored Fiber and an External Medium)

  • 김광택;이규효;신은수;황보승;손경락;김정근;이동호;송재원
    • 한국광학회지
    • /
    • 제16권6호
    • /
    • pp.494-499
    • /
    • 2005
  • 코어가 확산된 단일모드 광섬유와 외부 물질 사이의 분산 특성의 차이를 이용하여 차단 특성이 우수한 단파장 통과 필터(short-pass filter)를 구현하였다. 두 물질의 결합 방법으로 측면 연마 기법을 도입하였다. 실험 결과 소자의 대역경계 파장(band edge wavelength)은 코어의 확산 정도로 조절이 가능하였다. 일반 통신용 단일 모드 대신에 열확산 코어 확산 광섬유를 도입함으로써 더 예리한 파장응답을 얻을 수 있었다. 열광학 효과를 이용하여 경계 파장을 400nm 이상 가변 할 수 있음을 관측하였다.

Cellulomonas sp. KL-6에 의한 섬유소 분해효소의 생산 (Production of Cellulase from Cellulomonas sp. KL-6)

  • 정영건;권오진
    • Applied Biological Chemistry
    • /
    • 제38권6호
    • /
    • pp.490-495
    • /
    • 1995
  • Cellulomonas sp. KL-6 균주가 생산하는 cellulase 중 CMCase나 FPase는 세포외로 다량 분비되나 ${\beta}-glucosidase$는 cell bound form으로 존재하여 배양액에서의 생산은 극히 미약하였다. CMCase와 FPase는 배양 5일째에, ${\beta}-glucosidase$는 배양 4일째에 각각 최대생산을 나타내었다. $CaCO_3(0.1%)$가 첨가된 효소생산 최적조건에서 CMCase는 $82\;unit/m{\ell}$를, FPase는 $80\;unit/m{\ell}$를 그리고 ${\beta}-glucosidase$$1.2\;unit/m{\ell}$를 각각 생산하였고 이는 기본배지에서 보다 $60{\sim}70%$의 생산증가를 가져왔다. KL-6 균주는 lignase와 laccase의 생산은 없었다.

  • PDF

Survival of Microorganisms on Antimicrobial Filters and the Removal Efficiency of Bioaerosols in an Environmental Chamber

  • Kim, Sung Yeon;Kim, Misoon;Lee, Sunghee;Lee, JungEun;Ko, GwangPyo
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권9호
    • /
    • pp.1288-1295
    • /
    • 2012
  • Exposure to bioaerosols causes various adverse health effects including infectious and respiratory diseases, and hypersensitivity. Controlling exposure to bioaerosols is important for disease control and prevention. In this study, we evaluated the efficacies of various functional filters coated with antimicrobial chemicals in deactivating representative microorganisms on filters or as bioaerosols. Tested functional filters were coated with different chemicals that included (i) Ginkgo and sumac, (ii) Ag-apatite and guanidine phosphate, (iii) $SiO_2$, ZnO, and $Al_2O_3$, and (iv) zeolite. To evaluate the filters, we used a model ventilation system (1) to evaluate the removal efficiency of bacteria (Escherichia coli and Legionella pneumophila), bacterial spores (Bacillus subtilis spore), and viruses (MS2 bacteriophage) on various functional filters, and (2) to characterize the removal efficiency of these bioaerosols. All experiments were performed at a constant temperature of $25^{\circ}C$ and humidity of 50%. Most bacteria (excluding B. subtilis) rapidly decreased on the functional filter. Therefore, we confirmed that functional filters have antimicrobial effects. Additionally, we evaluated the removal efficiency of various bioaerosols by these filters. We used a six-jet collision nebulizer to generate microbial aerosols and introduced it into the environmental chamber. We then measured the removal efficiency of functional filters with and without a medium-efficiency filter. Most bioaerosol concentrations did not significantly decrease by the functional filter only but decreased by a combination of functional and medium-efficiency filter. In conclusion, functional filters could facilitate biological removal of various bioaerosols, but physical removal of these by functional was minimal. Proper use of chemical-coated filter materials could reduce exposure to these agents.

입자분리효율을 높이기 위한 새로운 기술 (New Technologies for Enhancing Particles Separation Efficiency in Coagulation and Filtration)

  • Kunio, Ebie;Jang, Il-Hun
    • 상하수도학회지
    • /
    • 제18권2호
    • /
    • pp.254-269
    • /
    • 2004
  • Polysilicato-iron coagulant (PSI) is receiving attention in Japan as a substitute for aluminum-based coagulants. In the first part of this article, coagulation, sedimentation and filtration experiments were carried out using kaolin clay particles as the turbidizing material and four types of PSI with various molar ratios of polysilicic acid to ferric chloride (Si/Fe ratio). Results demonstrate that use of a PSI with a high Si/Fe ratio can cause a more dramatic decrease in treated water turbidity but a higher suction time ratio (STR) than when PACl is used. However, optimization by increasing the rapid agitation strength GR is found to greatly improve the STR. In addition, the series of filtration experiments verified that optimization of GR is greatly effective in controlling rapid increases in filter head loss, and also formation of a thin aging layer in the upper part of the filter bed by slow-start filtration is effective in improving filtered water turbidity over the entire filtration process. The second part of this article describes two innovative filtration techniques to increase the particle separation efficiency; (1) coagulant-coated filter medium by enhancing the electrical potential of the surface of the filter medium, and (2) coagulant dosing in influent by controlling the electrical potential of particles entering the filter layer. From the results of the various filtration experiments using a pilot plant, these two techniques were found to be very effective to reduce the effluent water turbidity from the start to the end of a filter run. Moreover, in the filtration experiments using these two methods simultaneously, higher removal efficiency of approximately 3-log (99.7%) was realized, resulting that the finished water turbidity was accordingly reduced to 0.004mg/L.