• Title/Summary/Keyword: Medical linear accelerator

Search Result 244, Processing Time 0.022 seconds

Analysis of Dose Delivery Error in Conformal Arc Therapy Depending on Target Positions and Arc Trajectories (동적조형회전조사 시 표적종양의 위치변위와 조사반경의 변화에 따른 선량전달 오류분석)

  • Kang, Min-Young;Lee, Bo-Ram;Kim, You-Hyun;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • The aim of the study is to analyze the dose delivery error depending on the depth variation according to target positions and arc trajectories by comparing the simulated treatment planning with the actual dose delivery in conformal arc therapy. We simulated the conformal arc treatment planning with the three target positions (center, 2.5 cm, and 5 cm in the phantom). For the experiments, IMRT body phantom (I’mRT Phantom, Wellhofer Dosimetry, Germany) was used for treatment planning with CT (Computed Tomography, Light speed 16, GE, USA). The simulated treatment plans were established by three different target positions using treatment planning system (Eclipse, ver. 6.5, VMS, Palo Alto, USA). The radiochromic film (Gafchromic EBT2, ISP, Wayne, USA) and dose analysis software (OmniPro-IMRT, ver. 1.4, Wellhofer Dosimetry, Germany) were used for the measurement of the planned arc delivery using 6 MV photon beam from linear accelerator (CL21EX, VMS, Palo Alto, USA). Gamma index (DD: 3%, DTA: 2 mm) histogram and dose profile were evaluated for a quantitative analysis. The dose distributions surrounded by targets were also compared with each plans and measurements by conformity index (CI), and homogeneity index (HI). The area covered by 100% isodose line was compared to the whole target area. The results for the 5 cm-shifted target plan show that 23.8%, 35.6%, and 37% for multiple conformal arc therapy (MCAT), single conformal arc therapy (SCAT), and multiple static beam therapy, respectively. In the 2.5 cm-shifted target plan, it was shown that 61%, 21.5%, and 14.2%, while in case of center-located target, 70.5%, 14.1%, and 36.3% for MCAT, SCAT, and multiple static beam therapy, respectively. The values were resulted by most superior in the MCAT, except the case of the 5 cm-shifted target. In the analysis of gamma index histogram, it was resulted of 37.1, 27.3, 29.2 in the SCAT, while 9.2, 8.4, 10.3 in the MCAT, for the target positions of center, shifted 2.5 cm and 5 cm, respectively. The fail proportions of the SCAT were 2.8 to 4 times as compared to those of the MCAT. In conclusion, dose delivery error could be occurred depending on the target positions and arc trajectories. Hence, if the target were located in the biased position, the accurate dose delivery could be performed through the optimization of depth according to arc trajectory.

Dose distribution at junctional area for head and neck radiotherapy (두경부 방사선치료시 접합 조사면의 선량분포)

  • 김정기;김기환;오영기;김진기;정동혁;신교철;양광모;조문준;박인규
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.161-169
    • /
    • 2001
  • For the head and neck radiotherapy, the technique of half beam using independent collimator is very useful to avoid overlapping of fields particularly when the lateral neck fields are placed adjacent to anterior supraclavicular field. Also abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom and the dose distribution at beam center of 2 half beams further examined according to depths(0 cm, 1.5 cm, 3 cm, 5 cm) for single anterior half beam and anterior/posterior half beam. The dose distribution to the junction line between photon and electron fields was also measured. For the single anterior half beam, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 88%, 93% and 95% of open beam, respectively. In the anterior/posterior half beams, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 92%, 93% and 95% of open beam, respectively At the junction line between photon and electron fields, hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to 6% of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was 4.5-30% of reference dose in the electron field. With above results, we concluded that when using electron beam or independent jaw for head and neck radiotherapy, the hot and cold dose area should be considered as critical point.

  • PDF

Effect of Fractionated X-ray Irradiation on Sprouted Barley Growth and Chlorophyll Concentration (X선의 분할조사가 새싹보리 생장과 클로로필 농도에 미치는 영향)

  • In Suck Park;Won-Jeong Lee;Sang-Bok Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1171-1178
    • /
    • 2023
  • In study, we investigated changes on growth and chlorophyll concentration on sprouted barley by fractionated X-ray irradiation (FXI). Group was divided into the control group (CG), 1-time irradiation group (30 Gy once), 2-time irradiation group (15 Gy 2 times), and 3-time irradiation group (10 Gy 3 times), and 20 grains were used per group. Experimental group (EG) was exposed by using linear accelerator (Clinac IS, VERIAN, USA), by 6 MV X-ray, SSD 100 cm, 18×10 cm2, 600 MU/min. Length was measured every day until 9th day, and chlorophyl was analyzed using spectrophotometer(uv-1800, shimadzu, japan) in 9th day. Data analysis was performed the One-way ANOVA using SPSS ver 26.0(Chicago, IL, USA). In the pre-germination irradiation group (Pre-GIG), the CG had greater length than the EG on all measurement days, and as the number of FXI increased, the length became shorter. In the post-germination irradiation group (Post-GIG), the length of the CG was statistically significantly greater than that of the EG on all measurement days, and as the number of FXI increased, the length also became longer. The chlorophyll concentration was higher in the Post-GIG than in the Pre-GIG, and chlorophyll concentrations of EG was higher in the Pre-GIG than in the CG, as well as and Post-GIG. In addition, the smaller the number of FXI, the higher the chlorophyll concentration in both groups. FXI was found to affect the growth and chlorophyll concentration of sprouted barley.

Compare to Evaluate the Imaging dose of MVCT and CBCT (Tomotherapy MVCT와 Linac CBCT의 Imaging dose 비교평가)

  • Yoon, Bo Reum;Hong, Mi Lan;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.83-89
    • /
    • 2014
  • Purpose : In case of the intensity modulated radiation therapy (IMRT) using Tomotherapy and linear accelerator (Linac), it was to compare and to evaluate the imaging dose of MVCT and CBCT that were performed daily for the correct set up of the patient. Materials and Methods : The human body model Phantom (Anderson rando Phantom, USA) was divided into the three parts as Head, Thorax, pelvis, and after GafChromic EBT3 film cut to the size of $0.5{\times}0.5cm2$.in the center of the recording area were situated on the ant, post, left, and right surface of the phantom and 2cm in depth from the ant, post, left, right, and center surface of the phantom, the surface dose and inner dose were measured repeatedly three times, respectively, using the tomotherapy (Hi Art) and the OBI of NovalisTx. The measured film calculated the output value by RIP version6.0 and then the average value of the dose was calculated by the one-way analysis of variance. Results : Using the human body model phantom, the results of MVCT and CBCT performance were that measurements of MVCT inner dose were showed $15.43cGy{\pm}6.05$ in the head, $16.62cGy{\pm}3.08$ in the thorax, $16.81cGy{\pm}5.24$ in the pelvis, and measurements of CBCT inner dose were showed $13.28{\pm}3.68$ in the head, from $13.66{\pm}4.04$ in the thorax, $15.52{\pm}3.52$ in the pelvis. The measurements of surface dose were showed in case of MVCT performance, $11.64{\pm}4.05$ in the head, $12.16{\pm}4.38$ in the thorax, $12.05{\pm}2.71$ in the pelvis, and in case of CBCT performance, $14.59{\pm}3.51$ in the head, $15.82{\pm}2.89$ in the thorax, $17.48{\pm}2.80$ in the pelvis, respectively. Conclusion : In case of Inner dose, the MVCT using MV energy showed higher than the CBCT using kV energy at 1.16 times in the head, at 1.22 times in the thorax, at 1.08 times in the pelvis, and in case of surface dose, the CBCT was higher than MVCT, at 1.25 times in the head, at 1.30 times in the thorax, at 1.45 times in the pelvis. Imaging dose was a small amount compared to the therapeutic dose but it was thought to affect partially to normal tissue because it was done in daily schedule. However, IMRT treatment was necessarily parallel with the IGRT treatment through the image-guide to minimize errors between planned and actual treatment. Thus, to minimize imaging dose that the patients receive, when planning the treatment, it should be set up a treatment plan considering imaging dose, or it must be performed by minimizing the scan range when shooting MVCT.

The Effect of External Radiation Therapy in Management of Malignant Obstructive Jaundice due to Porta Hepatis Metastasis from Stomach Cancer (위암의 간문맥 전이로 발생한 악성 폐쇄성 황달에 대한 외부 방사선치료 효과)

  • Yang, Kwang-Mo;Kim, Joon-Hee;Kim, Chul-Soo;Suh, Hyun-Suk;Kim, Re-Hwe
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.339-348
    • /
    • 1995
  • Purpose : Since 1983, authors have conducted a study to evaluate the effect of external radiation therapy and to determine affected factors in management of the patients with malignant obstructive jaundice due to porta hepatis metastasis from stomach cancer. Materials and Methods : Thirty two patients with malignant obstructive jaundice due to porta hepatis metastasis from gastric cancer were presented. We have analysed 23 patients who were treated with external radiation therapy of more than 3000cGy. The radiation dose, disease extent at developement of jaundice, total bilirubin levels before radiation therapy, differentiation of histology, combind treatment, intent of primary surgery, initial stage of gastric cancer were analyzed to determine affected factors in radiation therapy. External radiation therapy was delivered with a daily dose of 180-300cGy, 5 times a week fractionation using 4 MeV linear accelerator. The radiation field included the porta hepatis with tumor mass by the abdominal ultrasonography or CT scan. In twenty three patients received more than 3000cGy, total irradiation dose was ranged from 3000cGy to 5480cGy, median 3770cGy. Among 23 patients, 13 patients were delivered more than equivalant dose of TDF 65(4140cGy/23fx). Results : Among 23 patients, complete, partial and no response were observed in 13, 5, 5 patients, respectively. The median survival for all patients was 5 momths. The significant prolongation of median survival was observed in complete responders(11 months) as compared to partial and no responders(5 months, 5 months respectively) Out of 13 patients with complete response, 6 patients lived more than a year Among 13 patients receiving more than 4140cGy equivalent dose, complete, partial and no response were observed in 10, 2 and 1 patients, respectively. The median survival for all these patients was 9.5 months. The median survival for complete responders(10/13) was 11.5 months. Among 10 patients receiving less than 4140cGy equivalent dose, complete, partial and no response were observed in 3, 3, 4 patients, respetively. The median survival for all these patients was 4.3 months Therefore, the radiation dose affected the results of treatment. For the complete response with prolongation of survival duration, at least 4140cGy equivalant dose should be delivered to porta hepatis. In evaluation of the disease extent, 7 patients of 13 complete responders showed localized disease in porta hepatis or peripancreatic area, but all patients with partial and no response showed wide extensive disease or persistant disease of primary gastric cancer. Therefore. the patients with the localized disease were the higher probability of complete response and long term survival. This study suggested that the radiation dose and the disease extent at developement of jaundice affected in radiation therapy for malignant obstructive jaundice. There were no serious complications related to external radiation therapy. Conclusion : External radiation therapy only could achieve the palliative effect in the patients with malignant obstructive jaundice due to porta hepatis metastasis from stomach cancer. This study suggested that the prolongation of survival duration could be achived in complete responders and radiation dose, extent of disease affected the results of treatment of malignant obstructive jaundice.

  • PDF

Neoadjuvant Chemotherapy and Radiotherapy in Locally Advanced Hypopharyngeal Cancer (국소 진행된 하인두암의 선행 항암화학요법 후 방사선치료)

  • Kim Suzy;Wu Hong-Gyun;Heo Dae-Seog;Park Charn I1
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.244-250
    • /
    • 2000
  • Purpose : To see the relationship between the response to chemotherapy and the final outcome of neoadiuvant chemotherapy and radiotherapy in patients with mocanry advanced hypopharyngeal cancer. Methods and Materials :A retrospective analysis was done for thirty-two patients with locally advanced hypopharyngeal cancer treated in the Seoul National University Hospital with neoadiuvant chemotherapy and radiotherapy from August 1979 to July 1997. The patients were treated with Co-60 teletherapy unit or 4MV or 6MV photon beam produced by linear accelerator. Daily fractionation was 1.75 to 2 Gy, delivered five times a week. Total dose ranged from 60.8 Gy to 73.8 Gy. Twenty-nine patients received continuous infusion of cisplatin and 5-FU. Other patients were treated with cisplatin combined with bleomycin or vinblastin. Twenty-four (75$\%$) patients received all three prescribed cycles of chemotherapy delivered three weeks apart. Six patients received two cycles, and two patients received only one cycle. Results :The overall 2-year and 5-year survival rates are 65.6$\%$ and 43.0$\%$, respectively. 5-year local control rate is 34$\%$. Organ preservation for more than five years is achieved in 12 patients (38$\%$). After neoadjuvant chemotherapy, 24 patients achieved more than partial remission (PR): the response rate was 75$\%$ (24/32). Five patients had complete remission (CR), 19 patients PR, and 8 patients no response (NR). Among the 19 patients who had PR to chemotherapy, 8 patients achieved CR after radiotherapy. Among the 8 non-responders to chemotherapy, 2 patients achieved CR, and 6 patients achieved PR after radiotherapy. There was no non-responder after radiotherapy. The overall survival rates were 60$\%$ for CR to chemotherapy group, 35.1$\%$ for PR to chemotherapy group, and 50$\%$ for NR to chemotherapy group, respectively (p=0.93). There were significant difference in five-year overall survival rates between the patients with CR and PR after neoadjuvant chemotherapy and radiotherapy (73.3$\%$ vs. 14.7$\%$, p<0.01). The prognostic factor affecting overall survival was the response to overall treatment (CR vs. PR, p<0.01). Conclusion :In this study, there were only five patients who achieved CR after neoadiuvant chemotherapy. Therefore the difference of overall survival rates between CR and PR to chemotherapy group was not statistically significant. Only the response to chemo-radiotherapy was the most important prognostic factor. There needs to be more effort to improve CR rate of neoadjuvant chemotherapy and consideration for future use of concurrent chemoradiotherapy.

  • PDF

Comparison of Experimental and Radiation Therapy Planning (RTP) Dose Distributions on Air Cavity (공동(air cavity)의 존재 시 실험적 선량분포와 치료계획상의 선량분포 비교)

  • Kim, Yon-Lae;Suh, Tae-Suk;Ko, Shin-Gwan;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.261-268
    • /
    • 2010
  • This study is compared that the dose distribution by experimentation and radiation therapy planning (RTP) when the air cavity region was treated high energy photon. The dose measurements were performed with a 6 MV photon beam of linear accelerator. The polystyrene and self made acyl phantom were similar to tissue density of the human body. A parallel plate chamber was connected to an electrometer. The measurement setup was SCD (Source Chamber Distance) 100 cm and the distance of surface from air cavity was 3 cm. Absorbed dose of interface were measured by area and height. The percent depth dose were measured presence and absence of air cavity, depth according to a ratio of field size and air cavity size. The dose distribution on planning was expressed to do the inhomogeneity correction. As the area of air cavity was increased, the absorbed dose were gradually reduced. It was slightly increased, when the height of air cavity was changed from 0 cm to 0.5 cm. After the point, dose was decreased. In case of presence of air cavity, dose after distal air cavity interface was more great than absence of air cavity. The rebuild up by field size and area of air cavity occurred for field size, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$ and $6{\times}6\;cm^2$, with fixed on area of air cavity, $5{\times}5\;cm^2$. But it didn't occur at $10{\times}10\;cm^2$ field size. On the contrary, the field size was fixed on $5{\times}5\;cm^2$, rebuild up occurred in area of air cavity, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$. but, it did not occur for air cavity, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$. All of the radiation therapy planning were not occurred rebuild up. It was required to pay attention to treat tumor in air cavity because the dose distribution of planning was different from the dose distribution of patient.

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.

Expression of Cell Cycle Related Genes in HL60 Cells Undergoing Apoptosis by X-irradiation (HL60 세포주에서 방사선 조사에 의한 Apoptosis와 세포 주기 관련 유전자의 발현 변화)

  • Kim, Jin-Hee;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.377-388
    • /
    • 1998
  • Purpose : To evaluate changes in expression of cell cycle related genes during apoptosis induced in HL60 cells by X-irradiation to understand molecular biologic aspects in mechanism of radiation therapy. Material and Methods : HL-60 cell line (promyelocytic leukemia cell line) was grown in culture media and irradiated with 8 Gr by linear accelerator (6 MV X-ray). At various times after irradiation, ranging from 3 to 48 hours were analyzed apoptotic DNA fragmentation assay for apoptosis and by western blot analysis and semi-quantitative RT-PCR for expression of cell cycle related genes (cyclin A, cyclin B, cyclin C, cyclin Dl, cyclin E, cdc2, CDK2, CDK4, $p16^{INK4a}$, $p21^{WAF1}$, $p27^{KIP1}$, E2F, PCNA and Rb). Results : X-irradiation (8 Gy) induced apoptosis in HL-60 cell line. Cycline A protein increased after reaching its peak 48 h after radiation delivery and cyclin E, E2F, CDK2 and RB protein increased then decreased after radiation. Radiation induced up-regulation of the expression of E2F is due to mostly increase of Phosphorylated retinoblastoma proteins (ppRb). Cyclin Dl, PCNA, CDC2, CDK4 and $p16^{INK4a}$ protein underwent no significant change at any times after irradiation. There was not detected $p21^{WAF1}$ and $p27^{KIP1}$ protein. Cyclin A, B, C mRNA decreased immediately after radiation and then increased at 12 h after radiation. Cyclin Dl mRNA increased immediately and then decreased at 48 h after radiation. After radiation, cyclin E mRNA decreased with the lapse of time. CDK2 mRNA decreased at 3h and increased at eh after radiation. CDK4 mRNA rapidly increased at 6 to 12 h after radiation. There was no change of expression of $p16^{INK4a}$ and not detected in expressin of $p21^{WAF1}$ and $p27^{KIP1}$ mRNA. Conclusion : We suggest that entry into S phase may contribute to apoptosis of HL60 cells induced by irradiation. Increase of ppRb and decrease of pRb protein are related with radiation induced auoptosis of HL60 cells and tosis of HL60 cells induced by irradiation. Increase of ppRb and decrease of PRb protein are related with radiation induced apoptosis of HL60 cells and this may be associated with induction of E2F and cyclinE/CDK2. These results support that $p21^{WAF1}$ and $p27^{KIP1}$ are not related with radiation induced-apoptosis.

  • PDF

Effects for Growth and Chlorophyll in Old-barley and New-barley Seed exposed by X-ray (X-선이 묵은보리 씨앗과 햇보리 씨앗의 생장과 클로로필 농도에 미치는 영향)

  • Sang-Bok, Jeong;Sun-Cheol, Jeong;Mo-Kwon, Lee;Yun-Ho, Choi;Kang-Un, Byun;Su-Ah, Yu;Sang-Eun, Han;Jun-Beom, Heo;Wan-Sik, Shin;Won-Jeong, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.149-156
    • /
    • 2023
  • The purpose of this study is to compare of growth and chlorophyl between old-barley seed (OBS, 2019) and New-barley seed (NBS, 2020) exposed by X-ray. After germination the OBS and NBS, experimental group was exposed by 30 Gy X-ray using linear accelerator (Clinac IS, VERIAN, USA), by 6 MV X-ray, SSD 100 cm, 18 × 10 cm2, 600 MU/min. Length was measured every day until 9th day, and chlorophyl was analyzed using spectrophotometer(uv-1800, shimadzu, japan) after measuring weight in 9th day. Data analysis was performed the Independent T-test using SPSS ver 26.0(Chicago, IL, USA). NBS grow more faster than OBS in control group, but OBS grow more faster than NBS in experimental group. Length of control group was longer significantly every day than that of experimental group in OBS. NBS weighted more than OBS in control group, but OBS weighted more than NBS in experimental group. In comparing chlorophyl density, NBS high more than OBS in control group as well as experimental group. Growth and weight of OBS was effected more those than NBS by X-ray, but NBS in chlorophyl by X-ray. It is expected to be used as basic data for future X-ray research in barley seed.