• 제목/요약/키워드: Medical image compression

검색결과 130건 처리시간 0.032초

2차원 손실 의료영상 압축

  • 김영섭
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2004년도 춘계학술대회 발표 논문집
    • /
    • pp.217-222
    • /
    • 2004
  • This paper focuses on lossy medical image compression methods for medical images that operate on two-dimensional(2D) integer wavelet transform. We offer an application of the Set Partitioning in Hierarchical Trees(SPIHT) algorithm to medical images, using a 2D wavelet decomposition and a 2D spatial dependence tree. The wavelet decomposition is accomplished with integer wavelet filters implemented with the lifting method, where careful scaling and truncations keep the integer precision small and the transform unitary. We have tested our encoder on medical images using different integer filters. Results show that our algorithm with certain filters performs as well and is sometimes better lossy coding using 2D integer wavelet transforms on medical images.

  • PDF

불균형 트리 구조를 이용한 3차원 의료 영상 압축 (3D volumetric medical image coding using unbalanced tree structure)

  • 김영섭
    • 한국산학기술학회논문지
    • /
    • 제7권4호
    • /
    • pp.567-574
    • /
    • 2006
  • 이 논문은 3차원 손실 정수 웨이브릿 변환을 이용한 손실 의료 영상 압축에 대한 방법을 보여준다. 또한 의료영상에 3차원 불균형 트리 웨이브릿 분할법과 3차원 불균형 수평단면상 의존성 트리를 이용한 불균형 트리 구조 알고리즘을 제공 한다. 그리고 3차원 웨이브릿 분할법에서 정수 웨이브릿 필터들을 이용한 리프팅 방법을 보여준다. 여러 정수 필터들과 16개의 코딩유닛 수를 이용하여 의료영상을 우리의 알고리즘으로 만든 인코더를 이용하여 테스트를 했습니다. 코딩 유닛 수 16 개를 사용하여 전에 사용 되었던 방법인 전체 영상 코딩 유닛에 비해 코딩 지연을 줄일 수 있었고, RAM의 용량도 줄일 수 있었다. 또한 불균형의 트리 구조를 사용하여 2차원을 3 레벨 이상으로 사용할 수 있어서, 부호화와 복호화에서 각 픽셀에서 트리의 길이를 마음대로 조정할 수 있는 결과가 되었다. 결론적으로 사이즈가 적은 코딩 유닛과 불균형 웨이브릿 변환을 의료 영상에 적용하여 전에 했던 코딩방법보다도 정수 필터인 I(5,3) 필터 에서는 더욱더 좋은 결과를 보여 준다.

  • PDF

관심 영역에 기반한 의료 영상 압축 (Medical Image Compression based on Region of Interest)

  • 김희숙;임숙자
    • 한국멀티미디어학회:학술대회논문집
    • /
    • 한국멀티미디어학회 2004년도 춘계학술발표대회논문집
    • /
    • pp.228-231
    • /
    • 2004
  • 의학 분야에서 의료 영상 데이터에 해당하는 컴퓨터 단층 찰영(CT. Computer Tomography), 자기 공명 영상법 (MRI : Magnetic Resonance Imaging)둥의 데이터 등이 정확하고 신속한 진단ㆍ관리를 위하여 의료 영상 데이터 중에서 관심의 대상이 되는 영역은 무손실 압축 기법을 수행하고, 그외의 지역은 움직임 보상 방식을 사용하여 압축하는 방식을 제안하고 실험하였다. 그 결과 기존의 손실 압축 기법에 비하여 더 낮은 비트율로 효율적인 압축을 수행하였다.

  • PDF

이동형 의료영상 장치를 위한 JPEG2000 영상 뷰어 개발 (Development of JPEG2000 Viewer for Mobile Image System)

  • 김새롬;정해조;강원석;이재훈;이상호;신성범;유선국;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제14권2호
    • /
    • pp.124-130
    • /
    • 2003
  • 현재, 많은 병원이 방사선과 의료영상정보를 기존의 필름형태로 판독하고, 진료하는 방식에서 PACS를 도입하여 디지털 형태로 영상을 전송, 저장, 검색, 판독하는 환경으로 변화하고 있다. 한편, PACS가 가지는 가장 큰 제한점은 휴대성의 결핍이다. 본 연구는 이동형 장치가 가지는 호스트의 이동성 및 휴대성의 장점들을 살리면서, 무선 채널 용량의 한계, 무선 링크 사용이라는 제약점들을 감안하여 의료영상을 JPEG2000 영상압축 방식으로 부호화한 후 무선 환경을 고려한 전송 패킷의 크기를 결정하고자 하였으며, 무선 통신 중 발생되는 패킷 손실에 대응하기 위한 자동 오류 수정 기능도 함께 구현하고자하였다. Window 2000 운영체계에서 의료영상을 로드하고, 데이터베이스화하며, 저장하고, 다른 네트워크와 접속, 제어가 가능한 PC급 서버를 구축하였다. 영상데이터는 무선망을 통해 전송하기 때문에 가장 높은 압축비율을 지원하면서 에너지 밀도가 높은 JPEG2000 알고리즘을 사용하여 영상을 압축하였다. 또한, 무선망 사용으로 인한 패킷 손실에 대비하여, 영상을 JPEG2000 방식으로 부호화한 후 각 블록단위로 전송하였다. PDA에서 JPEG2000 영상을 복호화 하는데 걸리는 시간은 256*256 크기의 MR 뇌영상의 경우 바로 확인할 수 있었지만, 800*790 크기의 CR 흥부 영상의 경우 약 5초 정도의 시간이 걸렸다. CDMA 1X(Code-Division Multiple Access 1st Generation) 모듈을 사용하여 영상을 전송하는 경우, 256 byte/sec정도에서는 안정된 전송 결과를 보여주었고, 1 Kbyte/sec정도의 전송의 경우 중간 중간에 패킷이 손실되는 결과를 관찰할 수 있었다. 반면 무선 랜의 경우 이보다 더 큰 패킷을 전송하더라도 문제점은 발견되지 않았다. 현재의 PACS는 유선과 무선사이의 인터페이스의 부재로 인해 유무선 연동이 되지 못하고 있다. 따라서 이동형 JPEG2000 영상 뷰어는 PACS가 가지는 문제점인 휴대성을 보완하기 위하여 개발되었다. 또한 무선망이 가지는 데이터 손실에 대하여서도 허용할 수 있는 범위에서 재전송을 가능하게 함으로서 약한 연결성을 보완하였다. 본 JPEG2000 영상 뷰어 시스템은 기존 유선상의 PACS와 이동형 장치간에 유기적인 인터페이스 역할을 하리라 기대된다.

  • PDF

의료용 초음파 스트레인 영상 시스템의 실시간 구현 (Real-Time Implementation of Medical Ultrasound Strain Imaging System)

  • 정목근;권성재;배무호
    • 비파괴검사학회지
    • /
    • 제28권2호
    • /
    • pp.101-111
    • /
    • 2008
  • 의료용 초음파 영상 시스템에서 스트레인 영상 기법은 병변 주위의 조직보다 단단한 성질을 가지는 암이나 종양을 영상화할 수 있다. 준정적인 압축(quasistatic compression) 방법을 이용하여 스트레인 영상을 얻는 방법은, 조직에 변형을 가하기 전의 초음파 신호를 기준으로 하여 변형을 가한 후에 얻어진 초음파 신호 사이의 변위를 계산하고, 이를 공간 미분하여 스트레인을 구한다. 본 논문에서 변위의 계산은 복소 기저대역 신호의 자기상관(autocorrelation)을 계산하여 위상차로부터 구하고, 위상차를 시간 혹은 거리로 변환할 때 발생하는 오차를 중심주파수 편차를 보상하여 줄였다. 조작자의 손 움직임의 영향을 줄이기 위해 모든 스캔라인의 변위를 정규화시키는 알고리즘을 적용하여 균일한 스트레인 영상을 얻었다. 제안한 스트레인 영상 기법을 초음파 영상 진단기에서 실시간 동작하도록 구현하였다.

Control of mobile robot system with wireless transmission of image information.

  • Jeong, Sang-Hoon;Kwak, Jae-Hyuk;Lim, Joon-Hong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.908-911
    • /
    • 2004
  • There are various researches on mobile robot systems. Connection method between server and client of mobile robot system is one of them. In the case of mobile robot system, when connection method between server and client is wireless than wire, applications may be expanded. Also in remote monitoring environment using mobile robot system, we are interested in an effective transmission of the image information between server and client. In this paper, Bluetooth is used for connection method between server and client. One of the major applications of Bluetooth is the cable replacement for mobile and peripheral devices. Using Bluetooth, we propose the control method of mobile robot system. Bluetooth offers fast and reliable transmissions of both voice and data over the globally available 2.4GHz ISM (Industrial, Scientific and Medical) band. It has the advantage of small size, low power and low cost. It has the disadvantage of limited range and limited bandwidth. Also in order to transfer effectively image information between remote site(server) and mobile robot system(client) using Bluetooth, we applied to MPEG-2 and MPEG-4 image compression techniques and the results are compared with each other.

  • PDF

척추성형술이 인접 척추체에 미치는 영향 (The effects of vertebroplasty on adjacent vertebra)

  • 박정수;최철현;채수원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.746-750
    • /
    • 2007
  • Vertebroplasty has drawn much attention as a medical treatment for the compression fracture of spine, which strengthens the vertebral body and corrects deformity, and relieves pain in patients by injecting bone cement. However vertebroplasty can cause fracture on adjacent vertebra due to relative stiffness change. This study involves the biomechanical evaluation of the vertebroplasty especially on adjacent vertebral body. The finite element method has been employed to analyze the patient who was treated vertebroplasty under static and dynamic loading. For this study, a three-dimentioal model of the three-level ligamentous lumbar segment ($L1{\sim}L3$)is created from medical image data (CT)and compared with the experimental results in vitro.

  • PDF

인간의 시각 특성을 이용한 의학 영상에서의 블록 코딩 방법에 관한 연구 (New Block Coding Method for the Medical Images based on Human Visual System Characteristics.)

  • 지영준;김영훈;박광석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.51-54
    • /
    • 1992
  • Recently, the Image compression methods in cooperation with Human Visual System characteristics are being investigated lively. In this study, we propose a new block coding method using i) non-linearity of HVS in the noticeable differences, ii) spatial easting effects, and iii) HVS sensitivity curve according to spatial frequencies. For vector quantization, the third scheme was dole effective than existing ones. We have applied this method on chest images and the results have shown better subjective qualities.

  • PDF

척추성형술 시술에서 요추의 생체역학적 특성 변화 (Biomechanical Property Change of Vertebral body in Vertebroplasty)

  • 이준형;전성재;채수원;이태수;서중근;박정율;김상돈;이관행
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1324-1327
    • /
    • 2003
  • The compressed fracture of spine caused by osteoporosis is one of the most frequent diseases in bone fracture. Recently the vertebroplasty has drawn much attention as a medical treatment for the compressed fracture of spine, which strengthens the vertebral body and corrects deformity, and relieves pain in patients by injecting bone cement. The finite element analysis is used to investigate the vertebroplasty quantitatively. Previous works with finite element analysis have drawbacks in their simplified models geometry of vertebral body and with material properties of bone. In this paper the exact geometry of vertebral body has been constructed from medical image data and the biomechanical property changes of vertebral body in vertebroplasty have been investigate by using three dimensional finite element analysis.

  • PDF

GPGPU를 이용한 고속 의료 볼륨 영상의 압축 복원 (Fast Medical Volume Decompression Using GPGPU)

  • 계희원
    • 한국멀티미디어학회논문지
    • /
    • 제15권5호
    • /
    • pp.624-631
    • /
    • 2012
  • 많은 의료영상 시스템에서 의료 볼륨 데이터는 압축된 형태로 저장되어 있으며, 압축된 데이터는 가시화 이전에 압축 복원을 수행해야 한다. 압축 복원은 상당한 시간이 소모되기 때문에 본 연구는 삼차원 의료영상의 고속 복원 방식을 제안한다. 제안 방법은 의료영상의 특수성에 대한 사용자 요구를 감안하여, 손실과 무손실 압축을 모두 제공하며 점진적 개선(progressive refinement) 복원 속성을 갖는다. 그리고 그래픽스처리장치(GPU)를 이용한 병렬화를 수행하여 매우 짧은 시간 내에 압축 복원이 수행된다. 마지막으로 압축 복원과 볼륨 가시화를 연계하여 선택적 압축 복원 방법이 가능하며, 이를 통하여 볼륨 압축 복원의 추가적 성능 향상을 얻었다.