• 제목/요약/키워드: Medical examiners

검색결과 50건 처리시간 0.025초

Outcome of endodontic treatments performed by Brazilian undergraduate students: 3- to 8-year follow up

  • Jessica Gabriele da Rocha;Isabella Marian Lena;Jessica Lopes Trindade;Gabriela Salatino Liedke;Renata Dornelles Morgental;Carlos Alexandre Souza Bier
    • Restorative Dentistry and Endodontics
    • /
    • 제47권3호
    • /
    • pp.34.1-34.12
    • /
    • 2022
  • Objectives: This study aimed to evaluate the success rate of endodontic treatments performed by undergraduate students and the factors associated with the outcome. Materials and Methods: A follow-up of 3 to 8 years after root canal filling was carried out in 91 patients. At the follow-up visits, medical and dental history questionnaires were applied along with clinical and radiographic examinations. Data collected in the clinical exam included: the presence of pain, swelling, sinus tract, mobility, tenderness to palpation and percussion, periodontal probing profile, and type/quality of coronal restoration. Postoperative and follow-up radiographs were digitalized and analyzed by 2 trained and calibrated examiners to assess periapical healing. The treatment outcome was based on strict clinical and radiographic criteria and classified as success (absence of any clinical and radiographic sign of apical periodontitis) or failure (other combination). Logistic regression was used to investigate the impact of clinical and radiographic variables on endodontic treatment outcomes at a 5% significance level. Results: The success rate of endodontic treatments was 60.7%. The only risk factor significantly associated with failure was the presence of a periapical lesion on the postoperative radiograph (odds ratio, 3.35; 95% confidence interval, 1.17-9.54). Conclusions: The success rate of endodontic treatments performed by undergraduate students was low and was jeopardized by the presence of a periapical lesion on the postoperative radiograph.

OCS QC 프로그램을 통한 건진 센터 종양검사의 결과보고 개선 (Improvement of the Result Related to Tumor Marker Test Through the OCS QC Program)

  • 백송란;김성호;유소연;김년옥;문형호;유선희;조시만
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.185-188
    • /
    • 2009
  • 목적 : 건진센터 종양 검사가 정상범위 내에서 재검기준이 명확히 설정되어 있지 않아 검사자마다 각자의 재검기준에 따라 재검을 시행함에 따라 재검상의 편차가 크고 일괄적이지 못했다. 이를 개선하기 위해 정상치이하값에서의 재검기준을 마련하고 정상치이하인 값에서 trend 결과를 관리할 수 있는 본원 OCS QC (order communication system quality control)프로그램을 이용하여 건진 센터 종양 검사의 결과보고오류에 개선을 하고자 한다. 대상 및 방법 : 2009년 2월부터 3월까지 본원 건진 센터에서 종양 검사(AFP, CEA, CA19-9, CA125, PSA)를 실시한 환자들을 대상으로 하였다. 우선 각 검사의 정상범위에서 Inter assay CV%를 구하여 screening 기준 값을 설정하였다. OCS QC program에 진료과, 대상 검사종목, screening 기준 값을 입력하여 기준 값에 벗어난 결과는 색깔에 반전을 주었다. 1차로 5가지종양 검사를 전 결과대비 ${\pm}$ 30% 기준을 벗어난 screening 건수를 구하였고 2차로 각각의 종양 검사에 대해 전 결과 대비 AFP는 ${\pm}$ 60%, CEA와 CA19-9는 ${\pm}$50%, CA125와 PSA는 ${\pm}$40%로 기준 값을 상향조정하여 screening 건수를 구하였으며 정상치 이하에서의 재검기준도 설정하여 비교하였다. 결과 : 1차 screening 건수 백분율은 30~40%의 결과를 얻었고, 2차 screening 건수 백분율은 AFP 26.1%, CEA 18.9%, CA19-9 17.3%, CA-125 18.7%, PSA 21.0%로 평균 20%의 screening 백분율을 얻었다. 정상치 이하에서의 재검기준은 AFP 5.0이하$\leftrightarrow$10.0이상, CEA 1.0이하$\leftrightarrow$3.0이상, 2.0이하$\leftrightarrow$4.0이상, CA19-9와 CA-125 10.0이하$\leftrightarrow$30.0이상, PSA 1.0이하$\leftrightarrow$2.0이상으로 정하였으며 평균 20.4%의 screening 백분율에 재검기준을 적용시켜 실제 재검사 건수를 얻었다. 2달 동안 재검사 건수는 AFP 0건, CEA 15건, CA19-9 3건, CA-125 2건, PSA 5건이었다. 결론 : OCS QC 프로그램을 이용하여 시스템적인 재검기준을 마련함으로 검사자간 재검 실시 편차의 감소가 있었고 정상치 이하 값에서 결과보고오류에 대해 개선이 있을 것으로 사료된다.

  • PDF

의료용 초음파 프로브 상제균의 효과적인 소독법에 관한 연구 (A study on effective disinfection methods of medical ultrasound probe resident floras)

  • 윤준;김현주
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.346-354
    • /
    • 2018
  • 의료용 초음파 장치의 프로브에서 일반적으로 검사자와 피 검사자가 접촉이 가장 많은 부위 중 무작위로 3부분을 임의로 선정하여 프로브에 상제하고 있는 병원균을 검출하여 병원균의 종류와 균수를 알아보았다. 또한 검출된 병원균에 대하여 프로폴리스 추출액, 소독용 에탄올, 소독용 티슈를 이용하여 각 각 소독 후 병원균의 사멸정도를 정량적으로 알아보았다. 그 결과 선형 프로브에서는 S. aureus(32.3%), Bacillus spp.(26.1%), Micrococcus spp.(21.5%), CNS(20%)가 검출되었고, 볼록형 프로브에서는 S. aureus(26.2%), Strepto coccus(24.3%), Entero coccus(19.5%), Micrococcus spp.(15.5%), CNS(14.6%), 부채꼴 프로브에서는 S. aureus(24.1%). Micrococcus spp(24.1%), Entero coccus(20.7%), Strepto coccus(17.2%), CNS(13.8%)순으로 검출되었다. 검출된 병원균을 대상으로 소독을 위해 선정한 3가지 소독액을 이용하여 소독한 결과 소독용 에탄올의 경우 대부분의 병원균을 사멸시켰으며 최소 91.3 %에서 최대 100 %의 사멸효과로 가장 큰 소독 효과가 있는 것으로 분석되었다(P>0.05). 또한 프로폴리스 추출액과 소독용 티슈의 경우 모든 소독용 에탄올에 비해 소독효과는 낮았으나 소독효과에는 통계적으로 유의한 것으로 분석되었다(P>0.05). 실험결과를 보면 대부분의 초음파 프로브에서 다양한 병원균이 검출되었으며, 소독용 에탄올, 소독용 티슈의 소독효과가 있었으며 특히 프로폴리스 추출액을 이용한 소독도 병원균 사멸에 효과가 있는 것으로 분석되어 향 후 검사자와 피검사자의 접촉이 많은 초음파 프로브 소독 시 적용한다면 감염예방에 있어 도움이 될 것으로 사료된다.

당뇨병 환자의 혈압 일주기 리듬에 관한 조사연구 (A Study on the Circadian Blood Pressure Rhythm of Diabetic Patients)

  • 김화순;서화숙
    • 대한간호학회지
    • /
    • 제30권3호
    • /
    • pp.741-749
    • /
    • 2000
  • This study was performed to investigate the relationship between reversed circadian blood pressure and risk factors of peripheral vascular disease in non-insulin-dependent diabetes mellitus (NIDDM) subjects. The subjects in this study were 18 NIDDM patients who were hospitalized in a medical unit of an university medical center located in Incheon, Korea, between November, 1998 and March, 1999. Blood pressure was measured with a mercury sphygmomanometer by 2 trained examiners every 2 hours during 24 hours. NIDDM subjects were divided into a dipper group and non-dipper group. Dippers are defined as those who show a mean nighttime blood pressure(BP) drop of more than 10% compared with daytime BP. Non-dippers are defined as those who show a mean nighttime BP drop of less than 10%, or an elevation in BP compared with daytime BP. Daytime BP included values obtained between 6 a.m. and 10 p.m. Night time BP included values obtained between 10 p.m. and 6 a.m. Data was analyzed by SPSS/PC package. Chi-square( $^2$) test was used for the comparison of sex between The dipper group and non-dipper group. Mann-Whitney test was used for comparisons of values of the risk factors of peripheral vascular disease and the frequency of complications of diabetes between the dipper group and non-dipper group. The results are as follows. There were no significant differences in daytime systolic, diastolic, and mean blood pressures between the dipper group and non-dipper group. However, night time systolic, diastolic, and mean blood pressures in the non-dipper group were significantly nigher than those in the dipper group (p=.021). There were no differences in sex, age, body, weight, duration of diabetes, serum lipid levels, BUN and HbA1c between the two groups. On the contrary, 87.5% of non-dipper group subjects showed having hypertension, 30% of dipper group subjects showed having hypertension and this difference was statistically significant (p=.018). All of the non-dipper group subjects (N=8) showed having at least one diabetic complication. However, 40% of the dipper group subjects (N=10) showed having no diabetic complication at all and this difference was also statistically significant (p=.049). There were no significant differences in frequency of nephropathy, neuropathy and retinopathy between the dipper group and non-dipper group.

  • PDF

대동맥수술에서의 수술 중 신경계감시의 적용 (Application of Intraoperative Neurophysiological Monitoring in Aortic Surgery)

  • 장민환;채지원;임성혁
    • 대한임상검사과학회지
    • /
    • 제54권1호
    • /
    • pp.61-67
    • /
    • 2022
  • INM은 수술의 안정성을 더해주고 고위험군의 수술을 안전하게 진행할 수 있게 도움을 주고 있다. INM검사가 적용이 되는 모든 수술에서의 수술 과정과 신경학적 결손이 발생할 수 있는 과정에서 집중적으로 검사를 진행해 보다 신속하게 수술자에게 알리지 않으면 손상이 되었을 때 그에 대한 대처가 늦어서 환자에게 돌이킬 수 없는 심각한 후유증을 가져다 줄 수 있다. 대동맥류 및 대동맥 박리로 발생되는 대동맥 치환술은 개흉 및 개복술이 진행되며 심장의 혈류를 차단하는 매우 위험한 수술이다. 대동맥에서 분지되어 척수에 혈류를 공급하는 혈관들을 교체할 때 척수로 가는 혈류가 감소해 척수 허혈이 올 수 있다. 대동맥 수술에서의 INM은 겸자시에 유발전위를 이용하여 빠르게 척수 허혈이 시작되는 시점을 찾아내고 수술자에게 보고해 척수 허혈을 방지하며 심각한 합병증을 막는 중요한 역할을 수행한다. 이에 수술의 과정과 TceMEP, SSEPs의 검사 방법 및 검사 시점, 검사 기준에 대하여 작성을 하여 INM을 시행하는 검사자들에게 도움이 되고자 본문을 작성하였다. 본문으로 인해 대동맥수술에서 INM의 필요성, 대동맥 수술에서의 흐름을 파악하고 정확하고 신속한 검사를 통한 보고로 원활한 검사가 진행되길 바라는 바이다.

검시관과 응급실 간호사의 좋은 죽음에 대한 인식과 죽음에 대한 태도 (Perception of Good Death and Attitudes toward Death between ER Nurses and Coroners)

  • 한지영
    • Journal of Hospice and Palliative Care
    • /
    • 제18권1호
    • /
    • pp.16-24
    • /
    • 2015
  • 목적: 본 연구는 검시관과 응급실 간호사들의 좋은 죽음에 대한 인식과 죽음에 대한 태도를 알아보기 위한 서술적 조사연구이다. 방법: 본 연구는 전국의 검시관 44명과 일개 광역시의 응급실 간호사 56명을 대상으로 실시하였으며, 자료수집기간은 2010년 10월 1일부터 2011년 2월 28일까지 실시되었다. 결과: 좋은 죽음에 대한 대상자 전체의 평균은 4점 만점에 2.98점이었으며 응급실 간호사는 2.95점, 검시관은 3.01점으로 검시관이 다소 높았으나 통계적으로 유의한 차이는 없는 것으로 나타났다. 죽음에 대한 태도에서는 대상자 전체 평균은 4점 만점에 2.72점으로 나타났으며 응급실 간호사는 2.61점, 검시관은 2.87점으로 검시관이 높았으나 통계적으로 유의한 차이는 없는 것으로 나타났다. 일반적 특성에 따른 좋은 죽음에 대한 인식과 죽음의 태도에서는 응급실간호사와 검시관 간의 유의한 차이가 없는 것으로 나타났다. 결론: 본 연구의 결과에서 검시관과 응급실 간호사가 인지하는 좋은 죽음과 죽음의 태도에 유의한 차이가 없는 것을 확인함으로써 죽음을 직면하는 상황보다는 죽음을 받아들이는 태도가 중요함을 확인하였으며, 죽음관련 교육에 대한 대상자의 높은 요구를 충족시키기 위해 죽음관련 교육의 기회를 확대하고 일회성이 아닌 연속적인 죽음관련 교육이 필요하다.

정도관리를 위한 요침사의 화학적 보존방법 (Chemical Preservation Methods of Urine Sediment for Quality Control)

  • 조성석;김명수;신경아
    • 대한임상검사과학회지
    • /
    • 제49권4호
    • /
    • pp.359-365
    • /
    • 2017
  • 요침사 검사는 물리화학적 검사보다 정도관리의 표준화가 어려운 실정이다. 본 연구에서는 요침사 정도관리의 합리성을 위해 요침사 보존제인 글루타르알데히드로 요침사를 보존하여 실물을 통한 현미경 검사로 요침사 정도관리가 가능한지를 알아보고자 하였다. 2.5% 글루타르알데히드를 보존액으로 하여 표본을 제작하였다. 보존제를 처리한 검체는 1주일 간격으로 4주간 세포의 형태학적 변형을 확인하였고, 이후 4주간은 보존여부를 확인하였다. 요침사 슬라이드 제작 후 2개의 슬라이드를 제작하였으며, 하나는 냉장보관, 다른 하나는 실온 보관하여 검체의 형태학적 변형을 확인하였다. 글루타르알데히드는 요침사를 냉장 보관하여 8주까지 보존하는 효과가 있었으며, 슬라이드 제작 후에는 냉장 보관하여 3일까지 안정한 것으로 나타났다. 또한 보존제 처리 후 슬라이드 제작하여 검사실간, 검사자간판독을 비교한 결과 낮은 일치도를 보였다. 결론적으로 본 연구를 통해 요침사 성분을 보존할 수 있으며, 실물을 통한 정도관리 및 교육용으로 활용될 것으로 기대된다.

유방 초음파 검사에서 석회화 유발 환경에 따른 반짝 허상과 팸텀을 활용한 영상 변화에 관한 연구 (A Study on the Image Change Using Twinkle Artifact Images and Phantom according to Calcification-Inducing Environment in Breast Ultrasonography)

  • 전철민
    • 한국방사선학회논문지
    • /
    • 제17권5호
    • /
    • pp.751-759
    • /
    • 2023
  • 유방 초음파 검사는 지방형 유방에서 영상화가 어렵고 미세 석회화를 찾는 데 어려움이 있지만, 미세 석회화의 발견은 유방암 선별 검사에 매우 중요하다. 초음파의 컬러 도플러 허상 중 반짝 허상은 영상에서 주로 결석이나 석회화 같은 강한 반사체에 발생되며 이를 이용한 평가 방법이 임상적으로 사용 중이다. 본 연구는 유방 석회화 중 가장 많이 차지하는 인산칼슘을 이용한 유방 모의 팬텀을 제작하여 초음파 장비의 컬러 도플러 설정 변수인 펄스 반복 주파수, 앙상블, 퍼시스트, 월 필터, 평활화, 선밀도, 임계값에 대해 실험을 진행했고 이를 통해 유방 초음파 검사에서 반짝 허상의 대조도를 개선하는 조건과 임상에서 이를 최대한 활용하기 위한 방안을 연구하고자 하였다. 그 결과 펄스 반복 주파수가 3.6 kHz ~ 7.2 kHz 범위에서 반짝 허상이 발생하며 10.5 kHz 이상에서는 발생하지 않았다. 앙상블의 경우 낮은 조건에서는 모든 크기의 석회화에 반짝 허상이 발생하였고 임계값 설정에서는 80에서 100 조건에서만 반짝 허상이 조금 증가했으며 1 mm 크기의 석회화에서는 발생하지 않았다. 퍼시스트, 월 필터, 평활화, 선밀도 설정은 반짝 허상이 발생하긴 했으나 조건별로 증가하지는 않아 설정 변수에 큰 의미가 없었으며 반짝 허상에 가장 큰 영향을 미친 것은 펄스 반복 주파수, 앙상블, 임계값으로 나타났다. 본 연구는 검사자가 컬러 도플러 설정을 조절하여 반짝 허상을 효과적으로 증가시키는 최적의 조건을 선택하는 데 도움이 될 것으로 사료된다.

전산화단층영상검사에서 단일에너지와 이중에너지를 이용한 뼈 부피측정의 비교 (Comparison of Bone Volume Measurements Using Conventional Single and Dual Energy Computed Tomography)

  • 김영균;박상훈;김연민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.253-259
    • /
    • 2017
  • 이중에너지 전산화단층촬영으로 뼈를 검사하여 다양한 keV와 조영제 물질 억제(material suppression iodine; MSI), 물질구분(material decomposition; MD)기법을 적용하였을 때, 단일에너지 전산화단층촬영과 비교 평가함으로써 칼슘 부피의 변화를 파악하고자 하였다. 인체유사 팬톰을 이용하여 단일에너지 전산화단층촬영의 영상을 기준으로 이중에너지 전산화단층촬영의 각각 70 keV, 100 keV, 140 keV 및 70 keV-MSI와 MD 칼슘강조-물제거(material calcium weighting; MCW)와 MD 요오드강조-물제거(material iodine weighting; MIW)기법을 적용한 후, 칼슘의 부피를 Agatston score 값으로 비교 평가하였다. 인체유사 팬톰의 칼슘 부피는 keV가 증가할수록 감소하였다(p<0.05). 가장 유사한 이중에너지 전산화단층촬영 집단은 70 keV로 그 차이는 각각 갈비뼈 $35.8{\pm}12.2$, 대퇴골 $16.1{\pm}24.1$, 골반 $13.7{\pm}18.8$, 척추 $179.0{\pm}61.8$이었다. 그러나 MSI의 부피는 부위별로 각각 갈비뼈 5.55%, 대퇴골 76.34%, 골반 55.16%, 척추 87.58%가 감소하였고, MD(MCW)는 각각 갈비뼈 55.96%, 대퇴골 80.78%, 골반 69.64%, 척추 54.23%가 줄었으며, MD(MIW)는 각각 갈비뼈 83.51%, 대퇴골 87.68%, 골반 86.64%, 척추 82.62%의 차이로 감소되었다(p<0.05). 이중에너지 전산화단층촬영으로 검사 시, 뼈의 부피는 keV의 증가에 따라서 감소하게 되고 약 70 keV의 에너지 영역에서 CSCT 집단과 유사한 부피로 측정할 수 있다. 그리고 MSI와 MD의 임상기법을 적용한 부피측정은 상당한 오차가 발생하므로 유의하여 사용하여야 한다.

골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로- (Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry-)

  • 김호성;동경래;류영환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.361-370
    • /
    • 2009
  • 골밀도의 질 관리는 검사를 시행하는 방사선사들의 책임과 의무이다. 하지만 질 관리의 이해 부족과 방법의 무지로 인한 잘못된 결과는 환자에게 치명적인 오류를 범할 수 있다. 따라서 이 논문은 올바른 질 관리의 이해와 방법을 기술하여 검사자 및 환자, 의뢰의사에게 골밀도 검사의 신뢰성을 확보하는 것을 목적으로 한다. 이중 에너지 엑스선 골밀도 기기(dual energy X-ray absorptiometry, DXA)는 골밀도 측정은 정확도와 정밀도가 우수하여야 작은 골량의 변화에도 진정한 생물학적 변화를 알 수 있다. 따라서 정확도와 정밀도를 높이기 위한 수단으로 장비 및 검사자의 올바른 질 관리가 지속적으로 이루어져야 한다. 올바른 장비관리방법은 매일 아침 장비 보정 질 관리 후 제조사에서 권고하는 팬텀을 이용하여 10~25회 측정하여 평균값을 구하고 이를 기준으로 허용 범위(${\pm}1.5%$)를 지정한다. 팬텀의 측정은 검사가 있는 날에 매일 측정하거나 일주일에 3회 이상 측정하여 실제 골밀도의 값의 변화 유무를 확인하여야 한다. 또한 측정된 팬텀의 골밀도수치를 기록 한 Shewart control chart를 Rule에 따라 평가한다. 이러한 관리는 장비의 설치 및 이동 시에 반드시 행해져야 한다. 검사자 관리방법은 정밀도 측정으로 평가하는데 정밀도는 재검사하였을 때에 실제 생물학적 변화 없이 수치상의 결과 값을 똑같이 재현될 수 있는지 알아보는 것이다. 측정 방법은 골밀도 검사를 진행하면서 환자를 두번씩 30번 측정하는 방법과 세번씩 15번 측정하는 방법이 있다. 측정에서 중요한 것은 한 번 검사 후 두번째나 세번째 검사에서도 반드시 검사 테이블에서 내려왔다 다시 올라가서 검사를 해야 한다. 측정된 골밀도수치로 정밀오차를 산출하고 95% 신뢰수준으로 정밀오차에 2.77을 곱하여 최소한의 생물학적 골밀도 변화를 산출한다. 산출된 값을 최소한의 의미있는 변화라고 표현하며 이 값을 넘어섰을 경우가 진정한 생물학적 변화구간이라고 할 수 있다. 검사자의 정도관리는 처음 검사를 시작하는 경우와 장비의 이동 및 교체 시에 반드시 행해져야하며 지속적으로 이루어져야 한다. 골밀도 검사를 시행하는 방사선사의 올바른 질 관리의 수행은 장비의 수명 연장과 정확한 결과의 산출로 이어져 검사의 신뢰성 확보와 환자 및 방사선사에게 부적절한 검사로 인한 방사능 노출의 최소화에 도움을 줄 것이다.

  • PDF