• Title/Summary/Keyword: Medical error

Search Result 1,106, Processing Time 0.029 seconds

An assessment of statistical errors of articles in the Journal of Korean Academy of Prosthodontics: Comparison between Korean version and English version (대한치과보철학회지에 게재된 논문의 통계적 오류: 국문논문과 영문논문의 비교)

  • Park, Dong-Gyu;Choi, Yong-Geun;Kim, Young-Su;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.273-285
    • /
    • 2009
  • Statement of problem: The aim of dental research is to advance scientific knowledge and leads to improvement in the treatment and prevention of dental disease. Utilizing an effective research design and adequate statistical methods are essential procedures ensuring that the results of researches are based on evidences. A research should utilize proper statistical methods without statistical errors; Otherwise, it could adversely affect clinical practice and future research. Purpose: This study was made to investigate the statistical methods used in the Journal of Korean Academy of Prosthodontics (JKAP) and then to assess them for the statistical errors. Material and methods: Among the total of 399 articles in the JKAP published from 2000 to 2006, 292 articles using statistics were reviewed. The validity of the statistical methods used in them were assessed using a checklist based on the guideline for statistical reporting in the uniform requirements for manuscripts submitted to biomedical journals by International Committee of Medical Journal Editors. The checklist consisted of three categories of statistical errors: 1) Unspecified computer statistical packages, 2) Inadequate description of statistical methods, 3) Misuse of statistical terms. Then, the results were compared between the Korean version and the English version in the JKAP. Results: Among the 212 articles using statistics in the Korean version, 115 articles (54%) and among the 80 articles using statistics in the English version, 47 articles (59%) were shown to have unspecified computer statistical packages without statistically significant difference (P = .66). Likewise, 101 articles (48%) in the Korean version and 25 articles (31%) in the English version were shown to have the inadequate description of statistical methods without statistically significant difference (P = .09). However, 114 articles (54%) in the Korean version and 19 articles (24%) in the English version were shown to have the misuse of statistical terms with statistically significant difference (P = .01). Conclusion: Some of the articles in the JKAP had inadequate statistical validity, given the statistical errors identified in this assessment. Hence, dental researchers should be more careful when it comes to describing and applying statistical methods.

The Comparative Assessment of the KVA and Dynamic Stereoacuity (동적시력(KVA)과 동적 입체시의 비교 평가)

  • Kim, Young-Cheong;Shim, Hyun-Suk;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.519-525
    • /
    • 2014
  • Purpose: On this study, we investigated the relationship between the kinetic visual acuity (KVA) and the dynamic stereoacuity and the effects of anisometropia with measuring KVA and the dynamic stereoacuity. Methods: For 63 adults (male 30, female 33), KVA and the dynamic stereoacuity were measured by using the kinetic visual acuity tester (KOWA AS-4A) and the Howard-Dolman test (H-D test) at distance 2.5 m after conducted full correction of subjects' refractive error respectly. Results: The means of KVA were $0.49{\pm}0.25$ for total subjects, $0.58{\pm}0.26$ for male, $0.40{\pm}0.22$ for female, and LogMAD (Log minimum angle of displacement) dynamic stereoacuities were $1.27{\pm}0.44$($28.44{\pm}25.03sec$ of arc) for total subjects, $1.28{\pm}0.44$($28.23{\pm}23.34sec$ of arc) for male, $1.27{\pm}0.45$($28.63{\pm}26.83sec$ of arc) for female. KVA showed a statistically significant difference between male and female (p=0.00), but dynamic stereoacuity was no significant difference (p=0.97). No significant correlation was present between KVA and dynamic stereoacuity (r=0.03). Also there were no significant differences in the dynamic stereoacuity of the three group which were classified according to the low, middle, high range of KVA (p=0.99). The anisometropia were less than 1 D and over 1 D when divided into two groups, KVA and dynamic stereoacuity showed no significant difference between each (p=0.11, p=0.99). There was no significant correlation between anisometropia and KVA (r=0.33), dynamic stereoacuity (r=0.18) but the correlation between KVA and anisometropia revealed more higer than between dynamic stereoacuity and anisometropia. Conculsions: The KVA for adults showed a significant difference between male and female and male was higher than female for KVA. The dynamic stereoacuity due to the KVA, the KVA and dynamic stereoacuity due to anisometropia were not significant differences between each and also were not great correlations.

Assessment of statistical errors of articles published in the Journal of the Korean Academy of Prosthodontics: 2006 - 2010 (대한치과보철학회지에서 볼 수 있는 통계적 오류의 고찰(2006 - 2010))

  • Kang, Dong-Wan;Seo, Yunam;Oh, Nam-Sik;Lim, Hoi-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.258-270
    • /
    • 2012
  • Purpose: Use of inappropriate statistical methods may lead to incorrect conclusions and a waste of valuable resources. The goal of this study was to assess the frequency and the types of several common statistical errors in the published articles of the Journal of the Korean Academy of Prosthodontics (JKAP) for a 5-year period. Materials and methods: Of 336 articles in the JKAP published from 2006 to 2010, 255 articles using statistics were reviewed and classified by statistical method and year. The frequency and types of the statistical methods were examined, and the statistical errors were evaluated by the appropriateness of the experimental design, assumption check, independent outcomes, proper sample size and suitable use of statistical method. Statistical guidelines were completed based on the appropriateness. Results: Of the 255 articles using statistics, 193 articles (75.9%) used inferential statistics and 153 articles used SPSS statistical software (60.0%). Of the articles using inferential statistics, the three most frequently used statistical methods were ANOVA (41.5%), t-test (20.0%), and the nonparametric method (16.9%). The average rate of statistical errors was 61.2 percent, similar to the rate reported by several studies completed for the medical journal. Conclusion: After the whole analysis of the difference among the groups, post-hoc tests for the pairwise comparisons are required. The optimal sample size calculation is an essential part of this study protocol. To minimize the occurrence of statistical errors, statistical guidelines were developed according to each statistical test procedure and will contribute to the academic improvement in the JKAP.

Comparison and Review of GBEF% on the Anterior and Right Lateral Images of Nuclear Hepatobiliary Scan (핵의학 간담도 스캔 시, 전면상과 우측 측면상에서의 담낭박출률에 대한 비교 및 고찰)

  • Lee, Eun-Byeol;Kim, Jae-Il;Do, Yong-Ho;Llm, Jung-Jin;Cho, Sung-Wook;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.92-96
    • /
    • 2018
  • Purpose In case of nuclear medical hepatobiliary scan, To quantitatively evaluate contractility of a gallbladder, gallbladder ejection fraction (GBEF%) is calculated from anterior images using fatty meal. However, when a gallbladder and other organs overlap on an anterior image, the gallbladder ejection fraction is not accurately evaluated. In order to reduce this error, the objective of our study was to figure out whether there is a significant difference in GBEF% calculated from the anterior and right lateral images. Materials and Methods After intravenous injection of 99mTc-Mebrofenin 370 MBq to randomly 50 patients who visited our hospital, we started to examine nuclear hepatobiliary scan. Using skylight(Philips, United States), we acquired anterior and right lateral image at 10 minutes, 20 minutes, 30 minutes, 60 minutes, 90minutes after injection. Using images at 60 and 90 minutes, gallbladder ejection fraction (GBEF%) was calculated from the anterior and right lateral images using JETstream workspace. For drawing more accurate ROI, CT images were referenced and 4 radiologists calculated the GBEF% in the same image and calculated the average value. We assessed whether there was a significant difference in GBEF% calculated from the anterior and right lateral images using SPSS program(Statistical Package for the Social Science, SPSS Ver.18 Inc. USA). Results About randomly 50 patients, the average value of the GBEF% calculated from the anterior image was 63.212 and the average value of the GBEF% calculated from the right lateral image was 62.666. GBEF% decreased 0.433% on the right lateral image compared with anterior image. Result of paired sample t-test, p value is over 0.05. So, there was no significant difference in GBEF% calculated from the anterior and right lateral images. Conclusion In the case that a gallbladder and other organs are not separated on an anteior image, Right lateral image would be better to acquire more accurate GBEF% than using anterior image.

Evaluation of Shielding Performance of Tungsten Containing 3D Printing Materials for High-energy Electron Radiation Therapy (고에너지 전자선 치료 시 텅스텐 함유 3D 프린팅 물질의 차폐 성능 평가)

  • Yong-In Cho;Jung-Hoon Kim;Sang-Il Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.641-649
    • /
    • 2023
  • This study compares and analyzes the performance of a shield manufactured using 3D printing technology to find out its applicability as a shield in high-energy electron beam therapy. Actual measurement and monte carlo simulations were performed to evaluate the shielding performance of 3D printing materials for high-energy electron beams. First, in order to secure reliability for the simulation, a source term evaluation was conducted by referring to the IAEA's TRS-398 recommendation. Second, to analyze the shielding performance of PLA+W (93%), a specimen was manufactured using a 3D printer, and the shielding rate by thickness according to electron beam energy was evaluated. Third, the shielding thickness required for electron beam treatment was calculated through a comparative analysis of shielding performance between PLA+W (93%) and existing shielding bodies. First, as a result of the evaluation of the source term through actual measurement and simulation, the TRS-398 recommendation was satisfied with an error of less than 1%, thereby securing the reliability of the simulation. Second, as a result of the shielding performance analysis for PLA+W (93%), 6 MeV electron beams showed a shielding rate of more than 95% at 3.12 mm, and 15 MeV electron beams showed a shielding rate of more than 90% at 10 mm thickness. Third, through simulations, comparative analysis between PLA+W (93%) materials and existing shields showed high shielding rates within the same thickness in the order of tungsten, lead, copper, PLA+W (93%), and aluminum. 6 MeV electron beams showed almost similar shielding rates at 5 mm or more and 15 MeV electron beams. Through this study in the future, it is judged that it can be used as basic data for the production and application of shielding bodies using PLA+W (93%) materials in high-energy electron beam treatment.

Analysis of the Eyeglasses Supply System for Ametropes in ROK Military (한국군 비정시자용 안경의 보급체계 분석)

  • Jin, Yong-Gab;Koo, Bon-Yeop;Lee, Woo-Chul;Yoon, Moon-Soo;Park, Jin-Tae;Lee, Hang-Seok;Lee, Kyo-Eun;Leem, Hyun-Sung;Jang, Jae-Young;Mah, Ki-Choong
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.579-588
    • /
    • 2018
  • Purpose : To analyze the eyeglasses supply system for ametropic soldiers in ROK military. Methods : We investigated and analyzed the supply system of eyeglasses for the ametropic soldiers provided by the Korean military. The refractive powers and corrected visual acuity were measured for 37 ametropic soldiers who wear insert glasses for ballistic protective and gas-masks supplied by the military based on their habitual prescriptions. Full correction of refractive error was prescribed for subjects having less than 1.0 of distance visual acuity, and comparison was held for inspecting the changes in corrected visual acuity. Suggestions were provided for solving the issues regarding current supplying system, and this study investigated the applicabilities for utilizing professional optometric manpower. Results : The new glasses supplied by army for ametropic soldiers were duplicated from the glasses they worn when entering the army. The spherical equivalent refractive powers of the conventional, ballistic protective and gas-mask insert glasses supplied for 37 ametropic soldiers were $-3.47{\pm}1.69D$, $-3.52{\pm}1.66D$ and $-3.55{\pm}1.63D$, respectively, and the spherical equivalent refractive power of full corrected glasses was $-3.79{\pm}1.66D$, which showed a significant difference(p<0.05). The distant corrected visual acuity measured at high and low contrast(logMAR) of conventional, ballistic protective and gas-mask insert glasses were $0.06{\pm}0.80$, $0.21{\pm}0.82$, $0.15{\pm}0.74$, $0.34{\pm}0.89$, $0.10{\pm}0.70$ and $0.22{\pm}0.27$, respectively, while the corrected visual acuity by full corrected glasses were increased to $0.02{\pm}1.05$, $0.10{\pm}0.07$, $0.09{\pm}0.92$, $0.26{\pm}0.10$, $0.04{\pm}1.00$ and $0.19{\pm}1.00$, respectively. There was a significant difference(p<0.05) except for the case of the low contrast corrected visual acuity of the conventional and gas-mask insert glasses. The procedure for ordering, dispensing, and supplying military glasses consists of 5 steps, and it was found that approximately two weeks or more are required to supply from the initial examination. Conclusion : The procedure of supplying the military glasses showed three issues: 1) a lack of refraction for prescription system, 2) relatively long length of time required for supplying the glasses, 3) an inaccurate power of supplied glasses. In order to solve those issues, in the short term, education is necessarily required for soldiers on the measurement of the refractive powers, and in the near future, further standard procedures for prescription of glasses as well as the securement of optometric manpower are expected.