• 제목/요약/키워드: Medical Ultrasound

검색결과 851건 처리시간 0.03초

Magnetic Resonance-Guided Focused Ultrasound in Neurosurgery: Taking Lessons from the Past to Inform the Future

  • Jung, Na Young;Chang, Jin Woo
    • Journal of Korean Medical Science
    • /
    • 제33권44호
    • /
    • pp.279.1-279.16
    • /
    • 2018
  • Magnetic resonance-guided focused ultrasound (MRgFUS) is a new emerging neurosurgical procedure applied in a wide range of clinical fields. It can generate high-intensity energy at the focal zone in deep body areas without requiring incision of soft tissues. Although the effectiveness of the focused ultrasound technique had not been recognized because of the skull being a main barrier in the transmission of acoustic energy, the development of hemispheric distribution of ultrasound transducer phased arrays has solved this issue and enabled the performance of true transcranial procedures. Advanced imaging technologies such as magnetic resonance thermometry could enhance the safety of MRgFUS. The current clinical applications of MRgFUS in neurosurgery involve stereotactic ablative treatments for patients with essential tremor, Parkinson's disease, obsessive-compulsive disorder, major depressive disorder, or neuropathic pain. Other potential treatment candidates being examined in ongoing clinical trials include brain tumors, Alzheimer's disease, and epilepsy, based on MRgFUS abilities of thermal ablation and opening the blood-brain barrier. With the development of ultrasound technology to overcome the limitations, MRgFUS is gradually expanding the therapeutic field for intractable neurological disorders and serving as a trail for a promising future in noninvasive and safe neurosurgical care.

인체 삽입형 인공 의료 기구물 기계적 결함 모니터링을 위한 초음파 시스템 및 계측 기술 연구 (Research on Ultrasound System and Measurement Technology for Mechanical Defect Monitoring of Human-inserted Artificial Medical Devices)

  • 윤상연;이문환;황재윤
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.470-473
    • /
    • 2021
  • 본 연구에서는 인공 관절치환술 시 삽입되는 라이너의 잔존 두께 측정과 비구컵과의 결합 상태를 판별 할 수 있는 생체 삽입형 보철물 두께 측정 시스템 개발을 위한 생체 삽입형 초음파 변환자의 개발, 잔존 두께측정 알고리즘 및 최적화된 초음파 운용 방법에 대한 연구를 진행했다. 세부적으로, 비슷한 민감도와 대역폭을 갖는 8MHz 와 20MHz의 중심주파수를 갖는 초음파 변환자를 제작하여 상용 폴리에틸렌 재질의 인공 고관절 라이너의 다양한 두께를 측정함으로써 신호대잡음비와 축방향 해상도 비교 분석을 진행하여 체내 초음파 운용 방식 최적화 연구를 진행하였다.

  • PDF

Dexamethasone or Dexmedetomidine as Local Anesthetic Adjuvants for Ultrasound-guided Axillary Brachial Plexus Blocks with Nerve Stimulation

  • Lee, Myeong Jong;Koo, Dae Jeong;Choi, Yu Sun;Lee, Kyu Chang;Kim, Hye Young
    • The Korean Journal of Pain
    • /
    • 제29권1호
    • /
    • pp.29-33
    • /
    • 2016
  • Background: The purpose of this study was to evaluate the effect of dexamethasone or dexmedetomidine added to ropivacaine on the onset and duration of ultrasound-guided axillary brachial plexus blocks (BPB). Methods: Fifty-one ASA physical status I-II patients with elective forearm and hand surgery under axillary brachial plexus blocks were randomly allocated to receive 20 ml of 0.5% ropivacaine with 2 ml of isotonic saline (C group, n = 17), 20 ml of 0.5% ropivacaine with 2 ml (10 mg) of dexamethasone (D group, n = 17) or 20 ml of 0.5% ropivacaine with 2 ml ($100{\mu}g$) of dexmedetomidine (DM group, n = 17). A nerve stimulation technique with ultrasound was used in all patients. The onset time and duration of sensory blocks were assessed. Results: The duration of the sensory block was extended in group D and group DX compared with group C (P < 0.05), but there was no significant difference between group D and group DX. However, there were no significant differences in onset time in all three groups. Conclusions: Dexamethasone 10 mg and dexmedetomidine $100{\mu}g$ were equally effective in extending the duration of ropivacaine in ultrasound-guided axillary BPB with nerve stimulation. However, neither drug has significantly effects the onset time.

Ultrasound Score to Select Subcentimeter-sized Thyroid Nodules Requiring Ultrasound-guided Fine Needle Aspiration Biopsy in Eastern China

  • Cheng, Pu;Chen, En-Dong;Zheng, Hua-Min;He, Qiu-Xiang;Li, Quan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권8호
    • /
    • pp.4689-4692
    • /
    • 2013
  • Ultrasound-guided fine needle aspiration biopsy (FNAB) is a costly diagnostic item with a low yield in identifying the tiny proportion of nodules that actually represent malignant disease. Our aim through this study was to obtain an ultrasound (US) score for selecting subcentimeter-sized thyroid nodules requiring FNAB in eastern China. Some 248 patients for a total of 270 thyroid nodules less than 1 cm in diameter underwent FNAB and subsequent surgery from January 2006 to March 2012 at our hospital. The clinicopathological and US data from all the nodules were analyzed retrospectively. An US score was developed on the basis of independent predictive factors for malignancy. Irregular shape, hypoechogenicity, no well-defined margin, presence of calcifications and ratio between antero-posterior and transversal diameters (AP/TR) ${\geq}1$ were independent predictive factors for malignancy on logistic regression analysis. US score were statistically significant, with ${\leq}2$ favoring benignancy with an 80.3% sensitivity and a 72.7% specificity. US score is useful for differentiating between malignant and benign subcentimeter-sized thyroid nodules. We suggest FNAB for nodules when the US score is higher than 2.

Ultrasound-guided erector spinae plane block for pain management after gastrectomy: a randomized, single-blinded, controlled trial

  • Jeong, Heejoon;Choi, Ji Won;Sim, Woo Seog;Kim, Duk Kyung;Bang, Yu Jeong;Park, Soyoon;Yeo, Hyean;Kim, Hara
    • The Korean Journal of Pain
    • /
    • 제35권3호
    • /
    • pp.303-310
    • /
    • 2022
  • Background: Open gastrectomy causes severe postoperative pain. Therefore, we investigated the opioid-sparing effect of the ultrasound-guided bilateral erector spinae plane block (ESPB) after open gastrectomy. Methods: Adult patients undergoing open gastrectomy were randomly assigned to either the ESPB group (ESPB + fentanyl based intravenous patient-controlled analgesia [IV-PCA]) or a control group (fentanyl based IV-PCA only). The primary outcome was total fentanyl equivalent consumption during the first 24 hour postoperatively. Secondary outcomes were pain intensities using a numeric rating scale at the post-anesthesia care unit (PACU) and at 3, 6, 12, and 24 hour postoperatively, and the amount of fentanyl equivalent consumption during the PACU stay and at 3, 6, and 12 hour postoperatively, and the time to the first request for rescue analgesia. Results: Fifty-eight patients were included in the analysis. There was no significant difference in total fentanyl equivalent consumption during the first 24 hour postoperatively between the two groups (P = 0.471). Pain intensities were not significantly different between the groups except during the PACU stay and 3 hour postoperatively (P < 0.001, for both). Time to the first rescue analgesia in the ward was longer in the ESPB group than the control group (P = 0.045). Conclusions: Ultrasound-guided ESPB did not decrease total fentanyl equivalent consumption during the first 24 hour after open gastrectomy. It only reduced postoperative pain intensity until 3 hour postoperatively compared with the control group. Ultrasound-guided single-shot ESPB cannot provide an efficient opioid-sparing effect after open gastrectomy.

Malignant Pleural Mesothelioma Diagnosed by Endobronchial Ultrasound- Guided Transbronchial Needle Aspiration

  • Kang, Byungju;Kim, Mi Ae;Lee, Bo Young;Yoon, Hwan;Oh, Dong Kyu;Hwang, Hee Sang;Choi, Changmin
    • Tuberculosis and Respiratory Diseases
    • /
    • 제74권2호
    • /
    • pp.74-78
    • /
    • 2013
  • A 61-year-old woman came to the hospital with dyspnea and pleural effusion on chest radiography. She underwent repeated thoracentesis, transbronchial lung biopsy, bronchoalveolar lavage, and thoracoscopic pleural biopsy with talc pleurodesis, but diagnosis of her was uncertain. Positron emission tomography showed multiple lymphadenopathies, so she underwent endobronchial ultrasound-guided transbronchial needle aspiration of mediastinal lymph nodes. Here, we report a case of malignant pleural mesothelioma that was eventually diagnosed by endobronchial ultrasound-guided transbronchial needle aspiration. This is an unusual and first case in Korea.

초음파 치료 시 초음파 세기 변화에 따른 생리적 효과 연구 (A Study of Ultrasound Rehabilitation Therapy: Physiological Effects by Change of Ultrasound Intensity)

  • 김성민;이만표;최병철;최상혁;배하석;정회승;박성윤
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권1호
    • /
    • pp.40-45
    • /
    • 2008
  • Therapeutic ultrasound which is developed for rehabilitation therapy have already been used for healing joint contracture, synechia, acute and chronic inflammatory diseases. Medical devices for pain-relief and healing using therapeutic ultrasound are actively being developed. This study measured the change of PTT with the transmitted ultrasound through the human body to find out the increase of compliance of blood vessels. Measurement method of PTT in this study is employed as useful ways to acquire physiological information of patients in the clinical case in order to measure the change of mechanical characteristics of blood vessels. This study confirmed the PTT change of rehabilitation patients through the thermal effects of ultrasound by using PTT and also found that it is possible to increase PTT by adjusting the warm water and ultrasound. The increase of PTT means the decrease of the pulse wave velocity from the cardiovascular system to the peripheral arteries. The physiological effects occurred using the warm water and ultrasound.

An Efficient Focusing Method for High Resolution Ultrasound Imaging

  • Kim Kang-Sik
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권1호
    • /
    • pp.22-29
    • /
    • 2006
  • This paper proposes an efficient array beamforming method using spatial matched filtering for ultrasound imaging. In the proposed method, ultrasound waves are transmitted from an array subaperture with fixed transmit focus as in conventional array imaging. At receive, radio frequency (RF) echo signals from each receive channel are passed through a spatial matched filter that is constructed based on the system transmit-receive spatial impulse response. The filtered echo signals are then summed. The filter remaps and spatially registers the acoustic energy from each element so that the pulse-echo impulse response of the summed output is focused with acceptably low side lobes. Analytical beam pattern analysis and simulation results using a linear array show that the proposed spatial filtering method can provide more improved spatial resolution and contrast-to-noise ratio (CNR) compared with conventional dynamic receive focusing (DRF) method by implementing two-way dynamically focused beam pattern throughout the field.

초음파 영상 특성을 이용한 실시간 초음파 영역 추출방법 (Real-time Ultrasound Contexts Segmentation Based on Ultrasound Image Characteristic)

  • 최성진;이민우
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권5호
    • /
    • pp.179-188
    • /
    • 2019
  • In ultrasound telemedicine, it is important to reduce the size of the data by compressing the ultrasound image when sending it. Ultrasound images can be divided into image context and other information consisting of patient ID, date, and several letters. Between them, ultrasound context is very important information for diagnosis and should be securely preserved as much as possible. In several previous papers, ultrasound compression methods were proposed to compress ultrasound context and other information into different compression parameters. This ultrasound compression method minimized the loss of ultrasound context while greatly compressing other information. This paper proposed the method of automatic segmentation of ultrasound context to overcome the limitation of the previously described ultrasound compression method. This algorithm was designed to robust for various ultrasound device and to enable real-time operation to maintain the benefits of ultrasound imaging machine. The operation time of extracting ultrasound context through the proposed segmentation method was measured, and it took 311.11 ms. In order to optimize the algorithm, the ultrasound context was segmented with down sampled input image. When the resolution of the input image was reduced by half, the computational time was 126.84 ms. When the resolution was reduced by one-third, it took 45.83 ms to segment the ultrasound context. As a result, we verified through experiments that the proposed method works in real time.

초음파실 표면의 세균 오염평가 (Bacterial Contamination of Surfaces in an Ultrasound Room)

  • 김희정;최유진;이창래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.231-237
    • /
    • 2021
  • The ongoing coronavirus disease 2019 (COVID-19) pandemic has highlighted the importance of hospital hygiene and infection control in hospital settings. To raise hygiene awareness among ultrasound technicians, we evaluated the hygiene status of an ultrasound room, in comparison with that of objects used in daily life. Using the swab method, the following surfaces were examined: eight surfaces in the ultrasound room including the ultrasound probes (convex, linear, sector, 3D), ultrasound track ball, ultrasound keyboard, ultrasound gel (sealed and in use) and pillow as well as four surfaces of everyday objects including subway handles, common computer keyboards, common computer mouse, and cell phones. The streak plate technique was used for inoculation into media, which was observed for the formation of bacterial colonies following incubation for 24 h. Six bacterial strains were detected from objects used in the ultrasound room, including methicillin-resistant Staphylococcus aureus. Four strains of bacteria were detected on surfaces of everyday objects. The equipment and accessories used in an ultrasound room can act as vehicles for infecting patients. Establishment of standardized hygiene protocols and periodic training of the staff are recommended to avoid cross-infection.