실시간 디지털 사지 혈류량 측정기 개발 (Development of Real Time Digital Peripheral Plethysmography)

  • 김수찬;김덕원
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.424-427
    • /
    • 1997
  • Electrical impedance plethysmography is still be one of the simplest and most convenient methods or non-invasive measurement of blood low, but it has the weak point can not do real-time measurement because of using chart-record or processing after receiving data from analog plethysmography through A/D converter. In this study. we developed hardware system composed of analog part which include auto-balancing circuit and calibration register and digital part which include 80C196KC, keypad, and LCD. we studied the algorithms or extracting parameter to calculate blood low and implemented it using general purpose micro controller.

  • PDF

휴대용 환자 감시장치의 설계 (Design of a Portable Patient Monitor)

  • 김응석;이은평;길문종;이경중;윤형로
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.407-410
    • /
    • 1997
  • In this paper, we have designed a portable patient monitor that monitors both ECG and NIBP(Non-Invasive Blood Pressure) for a patient who is bring moved around inside a hospital. System hardware consists of the one-chip microcomputer(80c251), A/D converter, ROM, RAM, LCD diplsy, two channel ECG module and NIBP module. NIBP module was calibrated to the values found in NIBP analyzer. ECG module detects QRS complex and compute heart rate. NIBP module measures the blood pressure by oscilometric method.

  • PDF

원격자동진단을 위한 ambulatory 심전도모니터링 시스템의 설계 (A Design of the Ambulatory ECG Monitoring System for the Remote Automatic Diagnosis)

  • 이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권4호
    • /
    • pp.277-284
    • /
    • 1991
  • This study describes the ambulatory ECG monitoring system for the remote autom atic diagnosis. System: tlardware is based on one chip microcomputer(80c31) and its peripherals which consists of A/D, EPROM, RAM, LCD display and two preamplifiers, Power circuits, control logic circuits. A/D converted data were differentiated and low pass filtered. The detection of QRS complex and R point were accomplished by software algorithm based on adaptive threshold computed on low pass fi:leered signal. Rhythm analysis is performed by RR interval and average RR interval. The performance of QRS detection algorithm is evaluated by using MIT/BIH data base. Using this system, the trends of the arrythmia during the long term could be saved and displayed.

  • PDF

모듈형 환자 모니터의 개발 (Development of a Module-Based Bedside Monitor for Patient Monitoring)

  • 우응제;박승훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권2호
    • /
    • pp.133-146
    • /
    • 1997
  • In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases, each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO with plethysmograph.raph.

  • PDF

LED 조명산업을 통한 융복합기술의 활성화 방안에 관한 연구 (A Study on the activation of fusion technology through LED lighting industry)

  • 허만일;유왕진
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.1-5
    • /
    • 2012
  • By using LED optical devices and improving the efficiency of optical devices as well as lighting apparatus for humans, LED lighting industry puts the purpose of manufacturing the main products related with information, electric, large-sized LCD BLU, automobile, shipbuilding, agriculture, medical treatment, environment, and telecommunications, etc. Moreover, the main products and the industrial lighting products are manufactured with fusion, as the result, LED lighting industry provides various effects as well as sources of technology based on practical use of LED technology in order to develop the industry from the perspective of the lower price, the higher efficiency, the higher function, the deeper reliance. In the future, not only the development of new LED technology but also the fusion and combination of digital IT technologies using wire-wireless communication, sensor, controller, and artificial intelligence will be expected to create new industrial fields.

TRIZ를 활용한 유아 및 노약자를 위한 안전감지시스템 개발에 관한 연구 (A Study on Development of Security Detection System for Infant, the Old and the Weak by using TRIZ)

  • 이국환;이경원
    • 반도체디스플레이기술학회지
    • /
    • 제7권1호
    • /
    • pp.59-65
    • /
    • 2008
  • There are no products, systems to manage health and detect security for infant, the old and the weak in Korea. Recently, the concerns of parents are increasing more about all of children(baby, infant, etc) because rate of birth is decreasing gradually. Also, the average span of human life is on an increasing trend according to well-being and evolution of medical treatment. Therefore, this treatise analyzed problems in managing and following-up infant, the old and the weak at present. By using TRIZ to solve problems, we devised new conceptional ideas, detail designs to manage health, detect security, cope with correspondences for them and developed the prototype and tested it. Excellent performances are proved through various field test.

  • PDF

마이크로컴퓨터를 이용한 치료방사선 선량측정 시스템의 구현 (The Implementation of A Therapy Radiation Dose Measurement System Using A Microcomputer)

  • 이동훈;권오상;홍준표;최창순;홍승홍
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.15-17
    • /
    • 1996
  • In this paper, the therapy radiation dose measurement system has been implemented by using a microcomputer after radiation was irradiated on diodes from the MM22 microtron accelerator. We have displayed 7-channel diode output values on the LCD after processing those in the 80196 MCU(Micro Computer Unit). Signal processing has been performed in the pulse mode because we can process the signal fast and use it to perform portal image by increasing a number of diode channels in the future. In order to verify the microcomputer based radiation measurement system of diodes, diode output values were compared with that of semiconductor.

  • PDF

5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구 (The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance)

  • 정해조;김희중;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제18권2호
    • /
    • pp.98-106
    • /
    • 2007
  • 2005년 6월 연세의료원 세브란스병원에서는 진단목적으로 20대의 5 mesa 화소 Totoku ME511L 평판 LCD 표시장치를 추가하여 PACS를 확장하였다. 20대의 Totoku ME511L 표시장치를 대상으로 반사, 휘도 반응, 휘도 공간 의존, 분해능, 잡음, 베일링 그레어, 그리고 색도 항목에 대하여 AAPM TG 18보고서에 기준하여 정량적인(또는 시각적인) 인수검사를 실시하였다. 측정에 사용된 장치는 색도를 측정할 수 있는 만원경식 휘도계, 조도계, 반사 측정에 필요한 빛 선원, 빛 차단 장치, 그리고 TG18 테스트 패턴들이었다. 선택된 8대의 표시장치에 대한 평균 확산 반사계수($R_d$)는 $0.019{\pm}0.02sr^{-1}$이었다. 휘도 반응 검사에서, 휘도비(LR), 최대 휘도 변이($L_{max}$), 그리고 최대 대조도 반응 변이는 각각 $550{\pm}100,\;2.0{\pm}1.9%$, 그리고 $5.8{\pm}1.8%$이었다. 휘도 균일도 검사에서, 최대 휘도 변이는 TG18-UNL10 테스트 패턴의 10% 휘도에 대하여 $14.3{\pm}5.5%$이었다. 분해능 측정은 휘도 측정법으로 수행하였으며 중심에서 퍼센트 휘도(${\Dalta}L$)는 $0.94{\pm}0.64%$이었다. 시각적인 방법의 잡음측정의 모든 경우에서, 중앙 및 주위 4사분면에서 가장 작은 것을 제외하고 15개의 모든 정사각형의 표적을 인식할 수 있었다. 글레어 비(GR)은 $12,346{\pm}1,995$이었다. 최대 색도 균일도 지표(D)는 $0.0025{\pm}0.0008$이었다. 또한 국내 실정에 적합한 진단용 표시장치의 정도관리 가이드라인 연구 결과를 제시하였다. 모든 인수검사 결과는 AAPM TG18 보고서 기준에 포함되어 진단 목적으로 사용하기에 적합하였다. 결론으로 인수검사는 표시장치가 진단에 사용하기에 적합한 성능임을 알려줄 뿐만 아니라 정도관리의 가이드라인, 최적 판독 환경, 그리고 표시장치의 교체시기를 결정하여주는 중요한 역할을 할 수 있다.

  • PDF

Comparison of different radiographic methods for the detection of the mandibular canal

  • Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제33권4호
    • /
    • pp.199-205
    • /
    • 2003
  • Purpose: To compare the visibility of the mandibular canal at the different radiographic methods such as conventional panoramic radiographs, Vimplant multi planar reformatting (MPR)-CT panoramic images, Vimplant MPR-CT paraxial images and film-based DentaScan MPR-CT images. Materials and Methods: Data of 11 mandibular dental implant patients, who had been planned treatment utilizing both panoramic and MPR-CT examination with DentaScan software (GE Medical systems, Milwaukee, USA), were used in this study. The archived axial CT data stored on CD-R discs were transferred to a personal computer with 17' LCD monitor. Paraxial and panoramic images were reconstructed using Vimplant software (CyberMed Inc., Seoul, Korea). Conventional panoramic radiographs, monitor-based Vimplant MPR-CT panoramic images, monitor-based Vimplant MPR-CT paraxial images, and film-based DentaScan MPR-CT images were evaluated for visibility of the mandibular canal at the mental foramen, 1 cm, 2 cm, and 3 cm posterior to mental foramen using the 4-point grading score. Results: Vimplant MPR-CT panoramic, paraxial, and DentaScan MPR-CT images revealed significantly clearer images than conventional panoramic radiographs. Particularly at the region 1 em posterior to mental foramen, conventional panoramic radiographs showed a markedly lower percentage of 'excellent' mandibular canal images than images produced by other modalites. Vimplant MPR-CT and DentaScan MPR-CT images did not show significant difference in visibility of the mandibular canal. Conclusion: The study results show that Vimplant and DentaScan MPR-CT imaging systems offer significantly better images of the mandibular canal than conventional panoramic radiograph.

  • PDF

응급환자 병원내 이송중의 모니터링을 위한 저전력형 휴대용 무선 ECG 시스템 개발 (Development of a Low-power Portable Wireless ECG System for Monitoring the Emergency Patient during Transfer in Hospital)

  • 장기웅;김지원;공세진;김철승;엄광문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2163-2164
    • /
    • 2006
  • It is desirable to monitor the vital signals, such as ECG, of a emergency patient during transfer in the hospital as well as in the ambulance. The purpose of this study is to develop a system which provides a real-time and wireless ECG to the medical staff nearby patient during transfer in hospital. In this context, we developed a low-power, low-cost and portable ECG system consisting of 1) ECG measurement and RF transmission module and 2) RF receiving and LCD display module. The developed system is expected to be useful in monitoring ECG of a patient during transfer in the hospital.

  • PDF