• Title/Summary/Keyword: Medical Information Platform

Search Result 185, Processing Time 0.045 seconds

A Study on Neuroactive Response Measurement Platform using Mechano Sensor (Mechano sensor를 이용한 신경자극반응 측정 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.198-201
    • /
    • 2012
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls. The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation, Train-of-four, and Double Burst Stimulation in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF

A Study on Neuroactive Response Sensing Platform after Injection of Muscular Relaxants (근 이완제 투여에 따른 신경 자극 반응 감지 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.331-334
    • /
    • 2011
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls.The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation(STS), Train-of-four(TOF), and Double Burst Stimulation(DBS) in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF

The Design and Implementation of AR Collaboration Service Platform for Technical Support in Industrial Sites (산업 현장의 기술 지원 AR 협업 서비스 플랫폼 설계 및 구현)

  • Han, Seongil;Lee, Daesik;You, Youngmo;Lee, Sangyoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.17 no.4
    • /
    • pp.1-11
    • /
    • 2021
  • In this paper, we explain the purpose of building a mobile app called "ARnetView" that can use the AR(augmented Reality)based calling function and AR based content creation function, and as well as an AR based data center that can share AR based video streaming and AR based contents on smartphones and tablet devices. For the AR(Augmented Reality) based data center implement, we have developed a mobile application and implemented a service system including an AR(augmented Reality) based calling function and AR based content production and AR based video streaming functions for real-time communication to connect a field technician and an expert so that the expert can see and discuss the situation in the field and technician and experts, they can draw digital annotation on mobile screen that accurately stick to 3D physical objects, allowing the expert to guide the technician step by step. In result, it provides a remote technical collaboration environment between field technician and expert. In addition, AR(Augmented Reality) collaboration service Platform was designed and implemented to increase work speed, efficiency, and utilization of advanced technicians, improve continuous productivity of equipment and facilities, maximize equipment and facility utilization, and strengthen industrial competitiveness. Therefore, through this, the AR collaboration service Platform can be applied to the industrial field, the medical field, and the entertainment/education field.

Design of A Downlink Power Control Scheme in Unequal Error Protection Multi-Code CDMA Mobile Medicine System

  • Lin, Chin-Feng;Lee, Hsin-Wang;Hung, Shih-Ii;Li, Ching-Yi
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.335-338
    • /
    • 2005
  • In this paper, we propose a downlink power control scheme to apply in the unequal error protection multi-code CDMA mobile medicine system. The mobile medicine system contains (i) blood pressure and body temperature measurement value, (ii) ECG medical signals measured by the electrocardiogram device, (iii) mobile patient's history, (iv) G.729 audio signal, MPEG-4 CCD sensor video signal, and JPEG2000 medical image. By the help of the multi-code CDMA spread spectrum communication system with downlink power control scheme and unequal error protection strategy, it is possible to transmit mobile medicine media and meet the quality of service. Numerical analysis and simulation results show that the system is a well transmission platform in mobile medicine.

  • PDF

Implementation of multi-channel IPCC platform for RBAC based CRM service (RBAC기반의 CRM 서비스를 위한 멀티 채널 IPCC 플랫폼 구현)

  • Ha, Eunsil
    • Journal of Digital Contents Society
    • /
    • v.19 no.9
    • /
    • pp.1751-1758
    • /
    • 2018
  • An integrated medical information system that integrates systems consisting of different environments centered on hospital information systems should be provided as a system that prioritizes the improvement of the quality of medical services, customer satisfaction, and patient safety. The RBAC-based medical information system is granted the access right according to task type, role, and rules. Through this, it is possible to use SMS channel, medical reservation and cancellation, customized statistics, and CRM / EMR interworking service using multi-channel to enable communication service without help of counselor and reduce the default rate of reservation patient, Operational improvement services can be extended to medical staff, patients and their families, as well as expanding to important decisions for patients.

Internet Based Telemedicine & Distance education System

  • Kim, Seok-Soo;Park, Cil-Cheol
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2001.06a
    • /
    • pp.373-377
    • /
    • 2001
  • The telemedicine & distance education system that this paper suggests has been designed on the CTE(Collaborative Telemedicine & distance Education) framework, which is an integrated multimedia environment. This is a CBM-based collaborative telemedicine & distance education type, different from the conventional doctor based general practice, and is an integrated multimedia telemedicine & distance education system capable of many application developments using information super highway. This paper presents the content regarding electronic medical examination chart and data treatment for efficient medical examination and prompt treatment by realizing mutual conversation type remote medical examination system among 3 parties(patient, doctor, pharmacist) on internet base. And, The implementation of this new teaming system should be designed with multimedia application development platform base which is interfaced with computer engineering, computer network technology, CSCW (Computer-Supported Cooperative Work) technology, and education engineering.

  • PDF

Complications in Microsuspension Laryngoscopy (현수 후두미세수술과 관련된 합병증)

  • Son, Hee-Young;Woo, Seung-Hoon;Kim, Jin-Pyeong
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.1
    • /
    • pp.23-29
    • /
    • 2011
  • Laryngomicrosurgery is common procedure applying to benign laryngeal lesion. Suspension of the laryngoscope is a vital component of Laryngomicrosurgery. Suspension laryngoscopy allows for bimanual surgery and a stable operating platform. Little information is known about oropharyngeal & vocal fold complications of suspension laryngoscopy. Because laryngomicrosurgery is dependent upon suspension laryngoscopy, surgeons should fully understand the risks of suspension laryngoscopy to properly educate and care for patients undergoing suspension laryngoscopy. That is problem to allow otolaryngologist is embarrassing, for voice restoration surgery are not satisfied with the results. The authors reviewed mechanical and phonological complications after laryngomicrosurgery.

  • PDF

Analysis on the Effects of the Lower Extremities Muscle Activation during Muscular Strength Training on an Unstable Platform with Magneto-Rheological Dampers (MR 댐퍼를 적용한 불안정판에서 하지 근력 훈련이 근 활성도에 미치는 영향 분석)

  • Choi, Y.J.;Piao, Y.J.;Kwon, T.K.;Kim, D.W.;Kim, J.J.;Kim, N.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.5
    • /
    • pp.636-646
    • /
    • 2007
  • Adequate postural control depends on the spatial and temporal integration of vestibular, visual, and somatosensory information. Especially, the musculoskeletal function is essential to maintain the postural control. The experimental studies was performed on the muscular activities in the lower extremities during maintaining and moving exercises on an unstable platform with Magneto Rheological(MR) dampers. The unstable platform of the developed system was controlled by electric currents to the MR dampers. A subject executed the maintaining and moving exercises which are presented through the display monitor. The electromyographies of the eight muscles in lower extremities were recorded and analyzed in the time and the frequency domain: the muscles of interest were rectus femoris(RF), biceps femoris(BF), tensor fasciae latae(TFL), vastus lateralis(VL), vastus medialis(VM), gastrocnemius(Ga), tibialis anterior(TA), Soleus(So). The experimental results showed that the muscular activities differed in the four moving exercises and the nine maintaining exercises. For the anterior-posterior pattern, the TA showed highest activities; for the left-right pattern, the TFL; for the 45, $-45^{\circ}$ pattern, the TFL and TA. Also, the rate of the increase in the muscular activities were affected by the condition of the unstable platform with MR dampers for the maintaining and moving exercises. The experimental results suggest that the choice of different maintaining and moving exercises could selectively train different muscles in various intensity. Futhermore, the findings suggested that the training using this system can improve the ability of postural control.

A Study on the Tele-medicine Robot System with Face to Face Interaction

  • Shin, Dae Seob
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.293-301
    • /
    • 2020
  • Consultation with the patient and doctor is very important in the examination. However, if the consultation cannot be done directly, such as corona virus, it is difficult for the doctor to determine the patient's condition more accurately. Recently, an image counseling system has been developed based on the Internet, but in the case of heart disease, remote medical counseling cannot be performed because it is not possible to stethoscope the heart sounds remotely. In order to solve this problem, it is necessary to develop an interactive mobile robot capable of remote medical consultation, and a doctor and a patient should be able to set a planting sound during consultation and transmit it in real time. In this paper, we developed a robot that can remotely control a medical counseling robot to move to a hospital room where patients are hospitalized, and to consult a patient in the room remotely from a doctor's office. A remote medical imaging stethoscope system for real-time heart sound transmission is presented. The proposed system is a kind of P2P communication that transmits video information, audio information, and control signal independently through webRTC platform, so that there is no data loss. Consults and sees doctors in real time and finds it more effective than traditional methods for patient security. The system implemented in this paper will be able to perform remote medical care in the place where the spread of diseases between humans like the recent corona 19 as well as the remote medical care of heart disease patients in the future.

Design of Mobile Telemedicine System using RFID based on Embedded Linux (임베디드 리눅스 환경에서 RFID 기반의 Mobile Telemedicine System 구현)

  • Yun, Chan-Young
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.05a
    • /
    • pp.479-482
    • /
    • 2006
  • Mobile Telemedicine uses common technologies that provide a conduit for information exchange between physicians nurses and patients. In addition to patient records, medical professionals will obtain vital signs and other reference data through Ubiquitous Sensor networks(USN). In this paper about a design and implementation of RFID reader platform that received RFID tag information from patients tags, transmit the data to SBC(Single board computer) based on Intel PXA255 ARM CPU and SBC transmit the data to MySQL server in hospital using by Wireless Internet. his system that based on Embedded Linux is composed of RFID module, ARM processor, RS-232 interface, and Wireless LAN. This paper also provides a brief overview and concept of RFID reader, and proposes the design and implementations of the RFID reader platform used QT and MySQL based on Embedded Linux.

  • PDF