• Title/Summary/Keyword: Medical Information Platform

Search Result 185, Processing Time 0.024 seconds

Efforts to Improve the E-Learning Center of the Korean Society of Radiology: Survey on User Experience and Satisfaction (대한영상의학회 이러닝 센터 발전을 위한 노력: 대한영상의학회 회원 설문조사)

  • Yong Eun Chung;Hyun Cheol Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1259-1272
    • /
    • 2022
  • Purpose As part of ongoing efforts to improve the current e-learning center, a survey was conducted regarding user experience and satisfaction to identify areas of improvement. Materials and Methods Radiologists (n = 454/617) and radiology residents (n = 163/617) of the Korean Society of Radiology were asked to answer a survey via email. The questionnaire asked for basic user information as well as user experiences relating to the e-learning center, such as workplace, frequency of use, overall satisfaction levels, reasons for satisfaction or dissatisfaction, and other suggestions for improvement. Results Annual members and all members of the e-learning center reported above average satisfaction levels of 67% and 42%, respectively. Approximately 30% of respondents viewed e-learning center lectures more than 5 times a month, with residents having a particularly high usage frequency. There was a high demand for additional lectures covering more diverse specialties (e-learning for annual members only: n = 28/97, e-learning for all members: n = 72/166), a smoother and more convenient searching platform/interface (n = 37/97 and n = 58/166, respectively), and regular content updates. In addition, many of the members suggested the addition of user-friendly functions such as playback speed control, a way to save viewing history, as well as requests for improved system stability. Conclusion Based on survey results, the educational committee plans to continue its efforts to improve the e-learning center by increasing the quality and quantity of available lectures, and increasing technical support to improve the stability and convenience of the e-learning digital system.

A novel method for determining dose distribution on panoramic reconstruction computed tomography images from radiotherapy computed tomography

  • Hiroyuki Okamoto;Madoka Sakuramachi;Wakako Yatsuoka;Takao Ueno;Kouji Katsura;Naoya Murakami;Satoshi Nakamura;Kotaro Iijima;Takahito Chiba;Hiroki Nakayama;Yasunori Shuto;Yuki Takano;Yuta Kobayashi;Hironori Kishida;Yuka Urago;Masato Nishitani;Shuka Nishina;Koushin Arai;Hiroshi Igaki
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.129-137
    • /
    • 2024
  • Purpose: Patients with head and neck cancer (HNC) who undergo dental procedures during radiotherapy (RT) face an increased risk of developing osteoradionecrosis (ORN). Accordingly, new tools must be developed to extract critical information regarding the dose delivered to the teeth and mandible. This article proposes a novel approach for visualizing 3-dimensional planned dose distributions on panoramic reconstruction computed tomography (pCT) images. Materials and Methods: Four patients with HNC who underwent volumetric modulated arc therapy were included. One patient experienced ORN and required the extraction of teeth after RT. In the study approach, the dental arch curve (DAC) was defined using an open-source platform. Subsequently, pCT images and dose distributions were generated based on the new coordinate system. All teeth and mandibles were delineated on both the original CT and pCT images. To evaluate the consistency of dose metrics, the Mann-Whitney U test and Student t-test were employed. Results: A total of 61 teeth and 4 mandibles were evaluated. The correlation coefficient between the 2 methods was 0.999, and no statistically significant difference was observed (P>0.05). This method facilitated a straightforward and intuitive understanding of the delivered dose. In 1 patient, ORN corresponded to the region of the root and the gum receiving a high dosage (approximately 70 Gy). Conclusion: The proposed method particularly benefits dentists involved in the management of patients with HNC. It enables the visualization of a 3-dimensional dose distribution in the teeth and mandible on pCT, enhancing the understanding of the dose delivered during RT.

Error Analysis of Delivered Dose Reconstruction Using Cone-beam CT and MLC Log Data (콘빔 CT 및 MLC 로그데이터를 이용한 전달 선량 재구성 시 오차 분석)

  • Cheong, Kwang-Ho;Park, So-Ah;Kang, Sei-Kwon;Hwang, Tae-Jin;Lee, Me-Yeon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.332-339
    • /
    • 2010
  • We aimed to setup an adaptive radiation therapy platform using cone-beam CT (CBCT) and multileaf collimator (MLC) log data and also intended to analyze a trend of dose calculation errors during the procedure based on a phantom study. We took CT and CBCT images of Catphan-600 (The Phantom Laboratory, USA) phantom, and made a simple step-and-shoot intensity-modulated radiation therapy (IMRT) plan based on the CT. Original plan doses were recalculated based on the CT ($CT_{plan}$) and the CBCT ($CBCT_{plan}$). Delivered monitor unit weights and leaves-positions during beam delivery for each MLC segment were extracted from the MLC log data then we reconstructed delivered doses based on the CT ($CT_{recon}$) and CBCT ($CBCT_{recon}$) respectively using the extracted information. Dose calculation errors were evaluated by two-dimensional dose discrepancies ($CT_{plan}$ was the benchmark), gamma index and dose-volume histograms (DVHs). From the dose differences and DVHs, it was estimated that the delivered dose was slightly greater than the planned dose; however, it was insignificant. Gamma index result showed that dose calculation error on CBCT using planned or reconstructed data were relatively greater than CT based calculation. In addition, there were significant discrepancies on the edge of each beam while those were less than errors due to inconsistency of CT and CBCT. $CBCT_{recon}$ showed coupled effects of above two kinds of errors; however, total error was decreased even though overall uncertainty for the evaluation of delivered dose on the CBCT was increased. Therefore, it is necessary to evaluate dose calculation errors separately as a setup error, dose calculation error due to CBCT image quality and reconstructed dose error which is actually what we want to know.

A Study on the Application of Block Chain Technology on EVMS (EVMS 업무의 블록체인 기술 적용 방안 연구)

  • Kim, Il-Han;Kwon, Sun-Dong
    • Management & Information Systems Review
    • /
    • v.39 no.2
    • /
    • pp.39-60
    • /
    • 2020
  • Block chain technology is one of the core elements for realizing the 4th industrial revolution, and many efforts have been made by government and companies to provide services based on block chain technology. In this study we analyzed the benefits of block chain technology for EVMS and designed EVMS block chain platform with increased data security and work efficiency for project management data, which are important assets in monitoring progress, foreseeing future events, and managing post-completion. We did the case studies on the benefits of block chain technology and then conducted the survey study on security, reliability, and efficiency of block chain technology, targeting 18 block chain experts and project developers. And then, we interviewed EVMS system operator on the compatibility between block chain technology and EVM Systems. The result of the case studies showed that block chain technology can be applied to financial, logistic, medical, and public services to simplify the insurance claim process and to improve reliability by distributing transaction data storage and applying security·encryption features. Also, our research on the characteristics and necessity of block chain technology in EVMS revealed the improvability of security, reliability, and efficiency of management and distribution of EVMS data. Finally, we designed a network model, a block structure, and a consensus algorithm model and combined them to construct a conceptual block chain model for EVM system. This study has the following contribution. First, we reviewed that the block chain technology is suitable for application in the defense sector and proposed a conceptual model. Second, the effect that can be obtained by applying block chain technology to EVMS was derived, and the possibility of improving the existing business process was derived.

Future Development Strategies for KODISA Journals: Overview of 2016 and Strategic Plans for the Future (KODISA 학술지 성장전략: 2016 개관 및 미래 성장개요)

  • Hwang, Hee-Joong;Lee, Jung-Wan;Youn, Myoung-Kil;Kim, Dong-Ho;Lee, Jong-Ho;Shin, Dong-Jin;Kim, Byung-Goo;Kim, Tae-Joong;Lee, Yong-Ki;Kim, Wan-Ki
    • Journal of Distribution Science
    • /
    • v.15 no.5
    • /
    • pp.75-83
    • /
    • 2017
  • Purpose - With the rise of the fourth industrial revolution, it has converged with the existing industrial revolution to give shape to increased accessibility of knowledge and information. As a result, it has become easier for scholars to actively persue and compile research in various fields. This current study aims to focus and assess the current standing of KODISA: the Journal of Distribution Science (JDS), International Journal of Industrial Distribution & Business(IJIDB), the East Asian Journal of Business Management (EAJBM), the Journal of Asian Finance, Economics and Business (JAFEB) in a rapidly evolving era. Novel strategies for creating the future vision of KODISA 2020 will also be examined. Research design, data, and methodology - The current research will analyze published journals of KODISA in order to offer a vision for the KODISA 2020 future. In part 1, this paper will observe the current address of the KODISA journal and its overview of past achievements. Next, part 2 will discuss the activities that will be needed for journals of KODISA, JDS, IJIDB, EAJBM, JAFEB to branch out internationally and significant journals will be statistically analyzed in part 3. The last part 4 will offer strategies for the continued growth of KODISA and visions for KODISA 2020. Results - Among the KODISA publications, IJIDB was second, JDS was 23rd (in economic publications of 54 journals), and EAJBM was 22nd (out of 79 publications in management field journals). This shows the high quality of the KODISA publication journals. According to 2016 publication analysis, JDS, IJIDB, etc. each had 157 publications, 15 publications, 16 publications, and 28 publications. In the case of JDS, it showed an increase of 14% compared to last year. Additionally, JAFEB showed a significant increase of 68%. This shows that compared to other journals, it had a higher rate of paper submission. IJIDB and EAJBM did not show any significant increases. In JDS, it showed many studies related to the distribution, management of distribution, and consumer behavior. In order to increase the status of the KODISA journal to a SCI status, many more international conferences will open to increase its international recognition levels. Second, the systematic functions of the journal will be developed further to increase its stability. Third, future graduate schools will open to foster future potential leaders in this field and build a platform for innovators and leaders. Conclusions - In KODISA, JDS was first published in 1999, and has been registered in SCOPUS February 2017. Other sister publications within the KODISA are preparing for SCOPUS registration as well. KODISA journals will prepare to be an innovative journal for 2020 and the future beyond.