• Title/Summary/Keyword: Medical Image Evaluation

Search Result 594, Processing Time 0.028 seconds

Analysis of Medical Image with CD-RAD Phantom (CD-RAD Phantom을 이용한 의료영상의 분석)

  • Kim, Chang-Bok;Kim, Young-Keun;Cho, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.369-369
    • /
    • 2007
  • The physical and visual evaluation of the identical X-rays are analyzed for medical image clarity with CD-RAD Phantom on this study. The method of measurement is to research CD-RAD by X-rays and to acquire images through image processing equipment, the image analyses are carried out by physical evaluation with statistical method through CD-RAD analyser program, and the visual evaluation of the identical X-rays is carried out by blind test for 20 observers. The result of it is that IQF value of the physical evaluation of Contrast-detail curve is 25 and IQF value of the visual evaluation is 30, so it is revealed that the physical evaluation is superior to the visual one. The special qualities of medical images have much importance of the transmission capacity of information to the image analyser, so it is concluded that 0비ective methods of the physical and visual analyses should be carried out side by side.

  • PDF

A Study on the Usefulness of the New Foot Oblique Projection (새로운 발 사방향 검사법의 유용성에 관한 연구)

  • Kim, Min-Suk;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.443-449
    • /
    • 2021
  • In this study, the purpose is to present the foot inclination angle for realizing an image similar to that of the existing examination method and to present the clinical usefulness of the new examination method through comparison between the existing examination method and the newly designed standing foot oblique projection. A foot phantom was used, and the magnification of the image according to the angle was quantitatively evaluated by attaching a nut to the position of the cuboid of the phantom. The internal oblique image acquired using a 30° wedge was set as the standard image. And that image was compared with the images acquired by changing the angle of the foot from 20° to 65° at intervals of 5°. Image evaluation was performed by 3 radiological technologists, and qualitative evaluation using a Likert 5-point scale for evaluation items of true oblique view and quantitative evaluation of the value obtained by measuring the diameter of a nut in each image were performed as image evaluation. For data analysis, reliability analysis between the measure and comparative analysis of the average value for each angle were performed. The qualitative evaluation score for each image was 4.5 to 5 points for most questions in the case of the standard image. And 4 points or less for most questions in the images with a foot angle of 45° or less, and an evaluation score close to the standard image was obtained in the image of 50° or more. And in the quantitative evaluation, the diameter of the nut was measured to be 9.28~9.56 mm. The qualitative evaluation showed a reliability of 0.95~1.0 and the quantitative evaluation was 0.62. As a result of comparing and analyzing the average of the quantitative and qualitative average values for each angle image, the group with the average value most similar to the standard image was images obtained at 55° and 60°, and in the post-analysis, the images of both groups were the same group as the standard image(p<0.01). As a result of this study, it was found that the angle of inclination of the foot for realizing the image most similar to the existing image in the standing foot oblique projection is 55°~60°. In addition, if this test method is applied to the clinic, it is believed that it will help prevent safety accidents such as falls during the test and improve test efficiency by minimizing the movement of patients for the test.

Performance Evaluation of Medical Image Transmission System using TH UWB-IR Technology

  • Lee, Yang-Sun;Kang, Heau-Jo
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.3
    • /
    • pp.97-100
    • /
    • 2006
  • In this paper, the transmission service for medical image is proposed via IEEE 802.15.4a on WPAN environment. Also, transmission and receiving performance of medical image using TH UWB-IR system is evaluated on indoor multi-path fading environment. On the results, the proposed scheme can solve the problem of interference from the medical equipment in same frequency band, and minimize the loss due to the indoor multi-path fading environment. Therefore, the transmission with low power usage is possible.

Clinical Evaluation for System Performance of Image Intensifiers (상강화기의 임상평가)

  • Kim, Chang-Seon;Charles R. Wilson
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.143-154
    • /
    • 1998
  • The image intensifier is the key component which determines the imaging characteristics in a fluoroscopic imaging system. A system performance program for clinical evaluation of two image intensifiers, that is simple, non-invasive and time effective, was described. Tests were grouped into three headings: x-ray generator, image quality, and collimation. For the x-ray generator, the kVp accuracy and the automatic exposure control operation were compared. Low- and high-contrast resolution measurements, and mesh pattern study belong to the image quality tests and those tests were performed for the video monitor and photospot images. For the collimation, usable field diameter and image distortion of image intensifiers were measured and quantified. The procedures and the results are hoped to be used for the clinical evaluation of system performance and/or acceptance tests for image intensifiers.

  • PDF

Study on the Present Gown of Oriental Medical Doctors in Korea (우리나라 현행 한의사 진료가운에 대한 조사연구)

  • 서옥경
    • Journal of the Korean Society of Costume
    • /
    • v.52 no.3
    • /
    • pp.139-147
    • /
    • 2002
  • This study was carried out to survey the contentment of the oriental medical doctors to the present gown which they wear. The objects were the oriental medical doctors who work for the university hospitals and the private clinics. The subjects were mainly the evaluation of the relation to the image of oriental hospital and the gown, the evaluation of the present their gowns and the evaluation on the improvement of their gowns. The collected data were analysed by the frequency, cross-table and $\chi^2$ using SPSS program. The results showed that the oriental medical doctors who work for the university hospital evaluated the difference of the image more important than those who work for the private clinics. Also the former was more than the latter on the necessity of the difference in the gowns between the western and oriental medical doctors. The oriental doctors regarded the tradition as of great importance in the improvement of their gown. More than 70% of them wanted to separate their gown for the spring-summer from that for the autumn-winter.

A Study on the Quantitative Evaluation of Medical Images by Using the Technique of Image Processing - Determination and Validation of Features - (화상처리 기술을 응용한 의료용 화상의 정량적 평가에 관한 연구 -특징량 추출 및 그 타당성 검토 -)

  • 송재욱
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.4
    • /
    • pp.619-626
    • /
    • 1998
  • This paper presents the features for quantitative evaluation of medical images based on the technique of image processing. In consideration of advice from medical doctor, 1 derive three features seemed to be strongly correlated with the degree of disease's advance. From comparison between each feature and evaluation value by medical doctor, our research shows that three features can be a useful aids in quantitative evaluation of lung's disease on chest X-ray images.

  • PDF

Side lobe free medical ultrasonic imaging with application to assessing side lobe suppression filter

  • Jeong, Mok Kun;Kwon, Sung Jae
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.355-364
    • /
    • 2018
  • When focusing using an ultrasonic transducer array, a main lobe is formed in the focal region of an ultrasound field, but side lobes also arise around the focal region due to the leakage. Since the side lobes cannot be completely eliminated in the focusing process, they are responsible for subsequent ultrasound image quality degradation. To improve ultrasound image quality, a signal processing strategy to reduce side lobes is definitely in demand. To this end, quantitative determination of main and side lobes is necessary. We propose a theoretically and actually error-free method of exactly discriminating and separately computing the main lobe and side lobe parts in ultrasound image by computer simulation. We refer to images constructed using the main and side lobe signals as the main and side lobe images, respectively. Since the main and side lobe images exactly represent their main and side lobe components, respectively, they can be used to evaluate ultrasound image quality. Defining the average brightness of the main and side lobe images, the conventional to side lobe image ratio, and the main to side lobe image ratio as image quality metrics, we can evaluate image characteristics in speckle images. The proposed method is also applied in assessing the performance of side lobe suppression filtering. We show that the proposed method may greatly aid in the evaluation of medical ultrasonic images using computer simulations, albeit lacking the use of actual experimental data.

Quantitative Evaluation of Setup Error for Whole Body Stereotactic Radiosurgery by Image Registration Technique

  • Kim, Young-Seok;Yi, Byong-Yong;Kim, Jong-Hoon;Ahn, Seung-Do;Lee, Sang-wook;Im, Ki-Chun;Park, Eun-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.103-105
    • /
    • 2002
  • Whole body stereotactic radiosurgery (WBSRS) technique is believed to be useful for the metastatic lesions as well as relatively small primary tumors in the trunk. Unlike stereotactic radiosurgery to intracranial lesion, inherent limitation on immobilization of whole body makes it difficult to achieve the reliable setup reproducibility. For this reason, it is essential to develop an objective and quantitative method of evaluating setup error for WBSRS. An evaluation technique using image registration has been developed for this purpose. Point pair image registrations with WBSRS frame coordinates were performed between two sets of CT images acquired before each treatment. Positional displacements could be determined by means of volumetric planning target volume (PTV) comparison between the reference and the registered image sets. Twenty eight sets of CT images from 19 WBSRS patients treated in Asan Medical Center have been analyzed by this method for determination of setup random error of each treatment. It is objective and clinically useful to analyze setup error quantitatively by image registration technique with WBSRS frame coordinates.

  • PDF

Digital Color Imaging Systems for Quantitative Evaluation of Skin Lesions (피부병변의 정량적 평가를 위한 디지털 컬러 영상 시스템)

  • Han, Byung-Kwan;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.195-198
    • /
    • 2007
  • In this paper, we introduce a digital cross-polarization and fluorescent color imaging system for quantitative evaluation of skin lesions. We describe the characterization of the imaging systems and the quantitative image analysis methods to show the feasibility for quantitative evaluation of skin lesions. The polarization color image was used to compute erythema and melanin index image which are useful for quantitative evaluation of pigmentation and vascular skin lesions, respectively. The fluorescent color image was used to quantitatively evaluate "sebum" and "vitiligo". In quantitative evaluation of various skin lesions, we confirmed the clinical efficacy of the imaging systems for dermatological applications. Finally, we sure that the imaging systems can be utilized as important assistant tools for the evaluation of skin lesions by providing reproducible quantitative result for widely distributed skin lesions.

Usefulness of Temporal Subtraction for The Detection of Interval Changes of Interstitial Lung Diseases on Chest Radiographs

  • Higashida, Yoshiharu;Ideguchi, Tadamitsu;Muranaka, Toru;Akazawa, Fumio;Miyajima, Ryuichi;Tabata, Nobuyuki;Ikeda, Hirotaka;Ohki, Masafumi;Toyofuku, Fukai;Doi, Kunio
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.454-456
    • /
    • 2002
  • The evaluation of interval changes between temporally sequential chest radiographs is necessary for the detection of new abnormalities or interval changes, such as pulmonary nodules and interstitial disease. For interstitial lung disease, the interval changes are very important for diagnosis and treatment. Especially, interstitial lung disease may show rapid changes in the radiographs, show changes in the entire lung field in minute detail, or show changes in multiple parts depending on the type. It is therefore difficult to have an accurate grasp of the condition of the disease only with conventional radiographs. The temporal subtraction technique which was developed at the University of Chicago, provides a subtraction image of the current warped image and the previous image. A temporal subtraction image, shows only differences and changes between the two images, can be very useful for a diagnosis of interstitial lung disease. However, the evaluation of the temporal subtraction technique for interstitial lung disease using receiver operating characteristic(ROC) studies has not been reported yet. Therefore, we have evaluated the clinical usefulness of a temporal subtraction technique for detection of interval changes of interstitial lung disease by ROC analysis.

  • PDF