• Title/Summary/Keyword: Medical Engineering

Search Result 8,937, Processing Time 0.04 seconds

Evaluation of Gene Expression Changes of Serotonin Receptors, 5-HT3AR and 5-HT2AR as Main Stress Factors in Breast Cancer Patients

  • Hejazi, Seyed Hesam;Ahangari, Ghasem;Pornour, Majid;Deezagi, Abdolkhaleagh;Aminzadeh, Saeed;Ahmadkhaniha, Hamid Reza;Akbari, Mohamad Esmail
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4455-4458
    • /
    • 2014
  • Breast cancer is a serious and potentially lethal multi-factor disease among 40-50 aged women in both developed and developing countries. Also, various studies have pointed to roles of neurotransmitters like serotonin in development of cancers, through action on various types of receptors. This study was conducted to evaluate serotonin receptor (5HT2AR and 5HT3AR) genes expression in peripheral blood mononuclear cells (PBMCs) of breast cancer patients in comparison with the healthy people and in the MCF7 cell line. Peripheral blood samples were obtained from 30 patients and 30 healthy individuals. Total RNA was extracted from PBMCs and MCF-7 cells. and 5HT2AR and 5HT3AR were detected by RT-PCR techniques. Finally, serotonin receptor gene expression variation in breast cancer patients and MCF-7 cells were determined by real time-PCR. This latter indicated significant promotion in expression of 5HT3AR and 5HT2AR in PBMCs in breast cancer patients but expression of 5HT2AR in the MCF-7 cell line was significantly decreased. In conclusion, after performing complimentary tests, determine of gene expression changes in serotonin receptors (5HT2AR and 5HT3AR) may be useful as a new approach in treatment of breast cancer based on use of antagonists.

Modeling and Simulation of Scheduling Medical Materials Using Graph Model for Complex Rescue

  • Lv, Ming;Zheng, Jingchen;Tong, Qingying;Chen, Jinhong;Liu, Haoting;Gao, Yun
    • Journal of Information Processing Systems
    • /
    • v.13 no.5
    • /
    • pp.1243-1258
    • /
    • 2017
  • A new medical materials scheduling system and its modeling method for the complex rescue are presented. Different from other similar system, first both the BeiDou Satellite Communication System (BSCS) and the Special Fiber-optic Communication Network (SFCN) are used to collect the rescue requirements and the location information of disaster areas. Then all these messages will be displayed in a special medical software terminal. After that the bipartite graph models are utilized to compute the optimal scheduling of medical materials. Finally, all these results will be transmitted back by the BSCS and the SFCN again to implement a fast guidance of medical rescue. The sole drug scheduling issue, the multiple drugs scheduling issue, and the backup-scheme selection issue are all utilized: the Kuhn-Munkres algorithm is used to realize the optimal matching of sole drug scheduling issue, the spectral clustering-based method is employed to calculate the optimal distribution of multiple drugs scheduling issue, and the similarity metric of neighboring matrix is utilized to realize the estimation of backup-scheme selection issue of medical materials. Many simulation analysis experiments and applications have proved the correctness of proposed technique and system.

Development of the second Telemetry and the External Management System for Total Artificial Heart (인공심장용 2차 무선정보전달장치와 외부 관리 시스템의 개발)

  • Yi, S.W.;Choi, J.H.;Lee, J.H.;Lee, J.J.;Om, K.S.;Ahn, J.M.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.243-244
    • /
    • 1998
  • The second telemetry is designed for supplying additional function which the first telemetry system doesn't have and as a part system of the External Management System (EMS). It makes a patient and an animal move more freely with wireless communication at a distance of free activity from the PC and can get most data from the first telemetry to send to the PC. Recently, our laboratory is developing a RF system for the second telemetry.

  • PDF

A study on the performance of the polymer valve in Total Artificial Heart (인공심장용 폴리머 밸브의 역류 특성 분석)

  • Lee, J.J.;Choi, J.H.;Lee, J.H.;Yi, S.W.;Om, K.S.;Ahn, J.M.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.241-242
    • /
    • 1998
  • For the aritificial heart valve, two types of valves-polymer and mechanical valve- are generally used. The polymer valve is used as a new low-cost artificial valve. Among the several properties of the artificial valve, the low-regurgitation property is important because it can provide better cardiac output characteristic. So in this study we analyzed and compared the regurgitation property of the mechanical valve which is generally used nowdays and the polymer valve which was made in our group. As results, the polymer valve showed the better regurgitation property compared to the mechanical valve approximately by 3 times, and increased the cardiac output by 10%.

  • PDF

Antimicrobial Effect of Medical Adhesive Composed of Aldehyded Dextran and ${\varepsilon}$-Poly(L-Lysine)

  • Lee, Jeong-Hyun;Kim, Hye-Lee;Lee, Mi-Hee;Taguchi, Hideaki;Hyon, Suong-Hyu;Park, Jong-Chul
    • Journal of Microbiology and Biotechnology
    • /
    • v.21 no.11
    • /
    • pp.1199-1202
    • /
    • 2011
  • Infection of surgical wounds is a severe problem. Conventional tissue reattachment methods have limits of incomplete sealing and high susceptibility to infection. Medical adhesives have several advantages over traditional tissue reattachment techniques, but still have drawbacks, such as the probability of infection, low adhesive strength, and high cytotoxicity. Recently, a new medical adhesive (new-adhesive) with high adhesive strength and low cytotoxicity, composed of aldehyded dextran and ${\varepsilon}$-poly(L-lysine), was developed. The antimicrobial activity of the new-adhesive was assayed using agar media and porcine skin. In the agar diffusion method, inoculated microorganisms that contacted the new-adhesive were inactivated, but this was not dependent on the amount of new-adhesive. Similar to the agar media results, the topical antimicrobial effect of new-adhesive was confirmed using a porcine skin antimicrobial assay, and the effect was not due to physical blocking based on comparison with the group whose wounds were wrapped.

Development of a Biometric Authentication System Based on Electroencephalography (뇌파 기반 개인 인증 시스템 개발)

  • Choi, Ga-Young;Kim, Eun-Ji;Kang, Ye-Na;Park, Su-Bin;Park, Su-Jin;Choi, Soo-In;Hwang, Han-Jeong
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.43-47
    • /
    • 2018
  • Traditional electroencephalography (EEG)-based authentication systems generally use external stimuli that require user attention and relatively long time for authentication. The aim of this study is to investigate the feasibility of biometric authentication based on EEG without using any external stimuli. Seventeen subjects took part in the experiment and their EEGs were measured while repetitively closing and opening their eyes. For identifying each subject, we calculated inter- and intra-subject cross-correlation using changes in alpha activity (8-13 Hz) during eyes closed as compared to eyes open. In order to optimize the number of recording electrodes, we calculated authentication accuracy by progressively reducing the number of electrodes used in the analysis. Significant increase in alpha activity was observed for all subjects during eyes closed, focusing on occipital areas, and spatial patterns of changed alpha activity were considerably different between the subjects. A mean authentication accuracy of 92.45% was obtained, which was retained over 75% when using only 8 electrodes placed around occipital areas. Our results could demonstrate the feasibility of the proposed novel authentication method based on resting state EEGs.

Real- Time Estimation of the Ventricular Relaxation Time Constant

  • Chun Honggu;Kim Hee Chan;Sohn Daewon
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.87-93
    • /
    • 2005
  • A new method for real-time estimating left ventricular relaxation time constant (T) from the left ventricular (LV) pressure waveform, based on the isovolumic relaxation model, is proposed. The presented method uses a recursive least squares (RLS) algorithm to accomplish real-time estimation. A new criterion to detect the end-point of the isovolumic relaxation period (IRP) for the estimation of T is also introduced, which is based on the pattern analysis of mean square errors between the original and reconstructed pressure waveforms. We have verified the performance of the new method in over 4,600 beats obtained from 70 patients. The results demonstrate that the proposed method provides more stable and reliable estimation of τ than the conventional 'off-line' methods.

Three-Dimensional Medical Visualization Method on PC (PC기반의 3차원 의학영상 가시화 방법에 관한 연구)

  • Lee, J.H.;Lee, S.H.;Lee, T.S.;Choi, I.T.;Park, S.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.259-260
    • /
    • 1998
  • In this paper, we present a 3D visualization method of medical image on PC. Using morphological method, we used to segment 2D medical images (X-ray CT, MRI). Presented method is treating in some detail two operations : dilation and erosion. Also known as an isosurface, using a constant density surface make a target organ in 3D. In the whole procedure for visualization. The medical images are implemented by using Visual C++ 5.0 in activeX and IDL(interactive data language) under PC environment.

  • PDF

ESTIMATION OF RHYTHMIC VARIATIONS IN R-R INTERVAL DURING SLEEP

  • Han, J.M.;Lee, J.M.;Nam, Y.H.;Park, H.J.;Park, K.S.;Jeong, Do-Un
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.195-196
    • /
    • 1998
  • Nonlinear energy operator(NEO) is usually used to estimate energy content of linear oscillator. We applied the modified nonlinear energy operator (MNEO) to detect R-peak of ECG and analyzed variation of R-R interval during sleep with nonlinear methods, piecewise correlation dimension and approximate entropy (ApEn) which estimate complexity of time series. ApEn applied to R-R interval reveals trends as sleep state changes.

  • PDF

A Measurement System for Rounded Shoulder Posture using a Wearable Stretch Sensor

  • Nguyen, Manh Thang;Dang, Quoc Khanh;Kim, Younghoon;Chee, Youngjoon
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.10-15
    • /
    • 2018
  • In this paper, we present a wearable measurement system for monitoring rounded shoulders. The system contains a shoulder correction band and a stretch sensor that can correct and measure shoulder posture, respectively. The capacitance of the stretch sensor changes linearly according to changes in the shoulders. To verify measurement, a motion analysis system was used as the reference to compare the change in the rounded angles of the shoulders and the change in the stretch sensor's capacitance. The results indicated that there is a high correlation between the two changes and the system can be used as a monitoring device for rounded shoulders.