• 제목/요약/키워드: Medical Engineering

검색결과 8,937건 처리시간 0.041초

LPS로 유도된 급성 간독성에 대한 구기자 추출물의 보호 효과 (The Preventive Effects of Lycii fructus Extract Against LPS-induced Acute Hepatotoxicity)

  • 강금석;권륜희;김인덕;이동근;이재화;이상현;하종명;하배진
    • 약학회지
    • /
    • 제51권5호
    • /
    • pp.296-300
    • /
    • 2007
  • The purpose of this study was to investigate the preventive effects of Lycii fructus Extract (LFE) against the acute hepatotoxicity-inducing lipopolysaccharide (LPS) in the liver. LFE of 100 mg/kg concentration was intraperitoneally administered into rats at dose of 1.5 ml/kg for 20 days. On the day 21, 1.5 ml/kg of LPS dissolved in saline was injected 4 hours before anesthetization. We examined the levels of glutamate oxaloacetate transaminase (GOT), glutamate pyruvate transaminase (GPT), lactate dehydrogenase (LDH) in serum of rats, superoxide dismutase (SOD) in mitochondrial fraction, and malondialdehyde (MDA), catalase (CAT), glutathione peroxidase (GPx) in liver homogenate. LPS-treatment markedly increased the levels of GOT, GPT, LDH and MDA, and significantly decreased those of SOD, CAT and GPx. But LFE-pretreatment decreased the levels of GOT, GPT, LDH and MDA, by 17.7%, 27.5%, 40.7% and 56.9%, respectively and increased those of SOD, CAT and GPx, by 90.5%, 78.9% and 83.8%, respectively. These results showed that the LFE had the preventive effects against the acute hepatotoxicity-inducing LPS in the liver.

자가 안면영상 촬영장치 개발 및 검증 (Development and Evaluation of an Self-Operated Face Capturing System)

  • 전영주;도준형;김장웅;김상길;이혜정;이유정;김근호;김종열
    • 한국한의학연구원논문집
    • /
    • 제17권2호
    • /
    • pp.115-120
    • /
    • 2011
  • Objectives : The purpose of this study is to develop an apparatus which can take a facial image by self-operated capturing technique. The user can obtain one's facial image immediately after adjusting facial tilt and focusing distance. The system has been designed for classifying Sasang typology based on facial image. Methods : The system is composed of a Webcam, one-way glass mirror and mini LCD. The Webcam takes a facial image which is displayed on the mini LCD. Then the user can see and adjust to the right position in the real time through the image mirror-reflected from the mini LCD. The optical sensor is used to estimate the proper focusing distance. To verify the performance of the system, 11 characteristic points on the facial image are used and compared with high performance DSLR camera(D700) by applying the coefficient of variance and Bland-Altman Plot. Results : The developed system and D700 show enough agreement with the small coefficient of variance to analyse constitutional types with a facial im mage. However, the result of Bland-Altman plot shows that the width parameters have distortions owing to short focusing distance. Conclusions : The system is expected to be utilized on u-healthcare services for home environment after improving the distortion in the width parameters.

Experimental Applications of in situ Liver Perfusion Machinery for the Study of Liver Disease

  • Choi, Won-Mook;Eun, Hyuk Soo;Lee, Young-Sun;Kim, Sun Jun;Kim, Myung-Ho;Lee, Jun-Hee;Shim, Young-Ri;Kim, Hee-Hoon;Kim, Ye Eun;Yi, Hyon-Seung;Jeong, Won-Il
    • Molecules and Cells
    • /
    • 제42권1호
    • /
    • pp.45-55
    • /
    • 2019
  • The liver is involved in a wide range of activities in vertebrates and some other animals, including metabolism, protein synthesis, detoxification, and the immune system. Until now, various methods have been devised to study liver diseases; however, each method has its own limitations. In situ liver perfusion machinery, originally developed in rats, has been successfully adapted to mice, enabling the study of liver diseases. Here we describe the protocol, which is a simple but widely applicable method for investigating the liver diseases. The liver is perfused in situ by cannulation of the portal vein and suprahepatic inferior vena cava (IVC), with antegrade closed circuit circulation completed by clamping the infrahepatic IVC. In situ liver perfusion can be utilized to evaluate immune cell migration and function, hemodynamics and related cellular reactions in each type of hepatic cells, and the metabolism of toxic or other compounds by changing the composition of the circulating media. In situ liver perfusion method maintains liver function and cell viability for up to 2 h. This study also describes an optional protocol using density-gradient centrifugation for the separation of different types of hepatic cells, allowing the determination of changes in each cell type. In summary, this method of in situ liver perfusion will be useful for studying liver diseases as a complement to other established methods.

의료용 표시기의 안전성 및 성능 평가를 위한 시험 항목 및 시험방법(안)연구 (Development of Standards of Tattoo Machine for Safety and Performance Evaluation)

  • 김영균;조승관;이태우;여창민;정병조;권영미;차지훈;허찬희;박기정;김동섭;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권2호
    • /
    • pp.151-157
    • /
    • 2011
  • Tattooing is a performance for decorative and cosmetic marking by placing permanent ink into the skin. As the cultural meaning of tattoo in Korea is changing, the tattoo machines are widely spread n permanent cosmetic market. Though the use of the tattoo machine was increased, the evaluation standards of tattoo machine were not existed. Korea Food and Drug Association regulated the electrical and mechanical safety standards which were founded on the IEC 601-1 second edition. Also they regulated he biological safety standards which were derived from the ISO 10993 series, however, these general valuations of common medical device were insufficient for evaluating tattoo machine. We developed the standards of tattoo machine for safety and performance evaluation for tattoo machine by preliminary hazard analysis in ISO 14971. The evaluation criteria of tattoo machines are focused on the mechanical invasion. We suggested the additional evaluation items of the needle speed, length, vibration with general valuation criteria of common medical device. We anticipate that this research may be a primary stage to figure a standard regulation and evaluation for tattoo machine.

3D 프린팅 기술의 의료기기 수리 적용에 대한 국내 규제 이슈 및 기술적 적합성 평가 (Regulation Issues in Korea and Technical Feasibility Evaluation of 3D Printing-Based Medical Device Repair)

  • 윤성욱;남경원
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권2호
    • /
    • pp.75-83
    • /
    • 2020
  • In large-scale hospitals, the department of biomedical engineering should always provide quick repair service for damaged medical devices to guarantee continuous patient treatment. However, in actual circumstances, there are so many time-consuming issues that delays device repair for weeks or even months; therefore, it is required to prepare alternative ways for quick repair service. In this study, we first mentioned about the regulation issues in Korea about the 3D printing-based medical device repair, and then introduced the results of our preliminary study that evaluated the feasibility of 3D printing-based medical device repair before real-field application. Results of the study demonstrated that, in all of the 23 cases, parts for repair that were manufactured by 3D-printing were successfully fixed and connected to the main body of the original device, and showed sufficient rigidity for protecting internal parts of the device. Considering the experimental results, medical device repair by applying 3D printing technology can be a promising alternative in cases when regular repair process is not available or takes too much time.

Multi-Electrode Array를 이용한 뇌 해마의 Total Activity 추산 (Total Activity Estimation of Hippocampal Slice Using Multi-Electrode Array)

  • 이정찬;김지은;조정연;손민숙;박경모;박지호
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.409-417
    • /
    • 2006
  • Research on neural circuit is a difficult area due to complexity and inaccessibility. Due to recent developments, the research using multi-electrode array of cells or tissues has become an important research area. However, there are some difficulties to decode the submerged meaning from huge and complex neural data. Moreover, it needs a harmonic collaboration between informatics and bioscience. In this paper, we have developed a custom-designed signal processing technique for multi-electrode array measured neural responses induced by electrical stimuli to the hippocampal tissue slices of the rat brain. The raw data from hippocampal slice using the multi-electrode array system were saved in a computer. Then we estimated characteristic points in each channel and calculated the total activity. To estimate the points, we used the Polynomial Fitting Approximation Method. Using the calculated total activity, we could provide the histogram or pseudo-image matrix to help interpretation of results.

ASIC을 이용한 고속의료영상처리보드의 개발을 위한 기초연구 (Researches of the Real-time Medical Imaging Precessing Board using ASIC architecture)

  • 서지현;박홍민;하태환;남상희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.299-300
    • /
    • 1998
  • Recently the development of medical modality like as MRI, 3D US, DR etc is very active. Therefore it is more required not only the enhancement of quality in medical service but the improvement of medical system based on quantization, minimization, and optimization of high speed. Especially, as the changing into the digital modality system, it gets to start using ASIC(Application Specific Integrated Circuit) to realize one board system. It requires the implementation of hardware debugging and effective speedy algorithm with more speed and accuracy in order to support and replace existing device. If objected image could be linked to high speed process board with special interface and pre-processed using FPGA, it can be used in real time image processing and protocol of HIS(Hospital Information System). This study can support the basic circuit design of medical image board which is able to realize image processing basically using digitalized medical image, and to interface between existing device and image board containing image processing algorithm.

  • PDF

신체자세 안정도의 정량분석에 관한 연구 (Quantitative analysis of body postural stability)

  • 차은종;김경아;이태수;이경무;김남균;김연희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.39-43
    • /
    • 1997
  • Posturography stands or quantitative assessment of body postural stability analysis. The present study developed a balance plate system to monitor patient's center of pressure (COP) movement and to analyze its stability. An equilateral triangular shaped plate was made of duralumin and forces were measured on the three vertices of the plate using industrial load cells. Specially designed electronic circuit picked up force signals ed into data acquisition system to calculate the cartesian coordinates of COP. COP calculation error was less than 2%. The force signals enabled to compute stability measures, which consisted of a variety of clinical parameters related to postural stability. Clinical experiments were carefully designed and performed on 40 normal subjects. The results were that 1) postural stability decreased with age and 2) the best parameters were those of posture deviation measures. A customized PC-based software package was developed to apply the present technique with a great convenience to monitoring and analyzing postural stability in an accurate and quantitative way.

  • PDF

효율적인 헬스케어서비스 제공을 위한 HL7 메시지 개선에 관한 연구 (The Study on HL7 Message Improvement for Supporting of Efficient Healthcare Service)

  • 허성욱;최성욱;김관형;오암석
    • 한국정보통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.1388-1394
    • /
    • 2014
  • 최근 고령화의 가속화로 인하여 의료비 부담이 증가하고 있으며 의료서비스의 질을 높이고 의료비용을 감소시키기 위한 연구가 계속되고 있다. 특히, U-헬스는 스마트기기의 확산, 무선통신, 센싱 기술과 함께 의료서비스와의 융합으로 더욱 지능화된 의료서비스가 이루어지고 있으며 아울러, 의료분야에서의 활용범위가 점점 확대되고 있다. 따라서 본 논문에서는 기존의 HL7 표준 메시지 전송 구조를 분석하고 신속한 처리를 위한 HL7 메시지의 처리개선 방안을 제시하고자 한다.

Efficacy of Motion Correction in fMRI

  • Kumazawa, Seiji;Yamamoto, Toru;Yamamoto, Tsuyoshi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 1999년도 Japanese Journal of Medical Physics
    • /
    • pp.182-185
    • /
    • 1999
  • PDF