• 제목/요약/키워드: Medical Engineering

검색결과 8,758건 처리시간 0.045초

의료기기의 Down-Time에 영향을 미치는 고장유형에 관한 연구 (A Study on Breakdown Patterns which influence Down-Time of Medical Equipment)

  • 서기홍;한규돈;김홍규;이호석;임효순;권혁남
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.100-101
    • /
    • 1998
  • In this paper, we've studied on the Breakdownpatterns which hove an effect on Down-Time of Medical Equipment. This study is based on the statistics of MMS(Maintenance Management System) accumulated since the opening of Samsung Medical Center. We hope that this paper, which is acquired through the analysis about the seasonal feature, the work pattern feature and the period used, is useful to reduce a term of Down-Time and to retrench hospital management cost.

  • PDF

의료기기 구입을 위한 의료기기(醫療機器)비교표 작성방법 및 활용방안 (HOW TO COMPOSE AND UTILIZE COMPARISION CHART OF MEDICAL EQUIPMENT FOR PURCHASING)

  • 김원규;강희숙;박민수;김태종;권혁남
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.108-109
    • /
    • 1998
  • As the need of enhanced medical treatment grows up, Purchasing step which include medical engineer's opinion has to be required. On this procedure, Medical Engineer Departments has used $\ulcorner$comparision chart$\lrcorner$. In this paper, How to compose and utilize comparison chart for purchasing of medical equipment by medical engineer in the hospital. It is made through the technical and objective investigation. From these points, We think that it can be available for proper installation and improved maintenance.

  • PDF

The Effect of Pulsatile Flow on Ultrafiltration In-Vitro Study and Comparison with Roller Pump

  • Lee K.;Jeong J. H.;Mun C. H.;Lee J. C.;Min B. G.
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.337-341
    • /
    • 2005
  • Blood pulsation has been reported to have an advantageous effect on extracorporeal blood circulation. However, the study of pulsatile blood flow in renal replacement therapy is very limited. The in-vitro experimental results of pulsatile blood flow on ultrafiltration, when compared with the conventional roller pump, are described in this paper. Methods: Blood flow rate (QB) and transmembrane pressure (TMP) were considered as regulating factors that have an influence on ultrafiltration. Experiments were performed under the condition of equal TMP and OB in both pulsatile and roller pump groups, Several kinds of hollow fiber dialyzers were tested using distilled water containing chemicals as a blood substitute. Mean TMP (mTMP) varied from 10 to 90mmHg while the QB was 200ml/min. Results: Ultrafiltration rate (QUF) was found to be linearly proportional to TMP, whereas QB had little influence on QUF. In addition, QUF was higher in the pulsatile group than the roller pump group at the identical TMP. Conclusion: In the controlled test, QUF increased solely as a consequence of blood pulsation, which implies that the pulse frequency represents an additional and important clinical variable during renal replacement therapy.

The Optimum TE in fMRI at 1.5T and 3.0T MRIs

  • Kim, Tae;Suh, Tae-Suk;Choe, Bo-Young;Lee, Hyoung-Koo;Shinn, Kyung-Sub;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 1999년도 Japanese Journal of Medical Physics
    • /
    • pp.431-432
    • /
    • 1999
  • PDF

주요국의 의료기기 품목 분류체계 조사분석을 통한 국내 의료기기 품목 신설 및 세분화 연구 (A Study on the Improvement of Domestic Medical Device Classification System through the Analysis of Major Foreign Countries)

  • 손지민;유강현;김유림;권경민;이희성;장원석
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권1호
    • /
    • pp.41-52
    • /
    • 2023
  • With the international change in the medical device market owing to the development of innovative medical engineering and the use of various raw materials, a systematic and rational medical device classification system is needed to safely manage newly developed medical devices. This study aims to improve the domestic medical device classification system by proposing product establishment and segmentation. It is based on medical device products from the United States and Europe that are only available in foreign systems and are more subdivided than domestic products. This study analyzes and compares the domestic and foreign medical device classification systems by examining laws, guidelines, and analysis reports in Korea, the United States, and Europe. In accordance with product establishment and segmentation criteria, products subject to improvement are presented. This study contributes to safely managing medical devices that do not fit with the current classification system and to solving the confusion caused by the lack of international harmony in product classification systems.

공적개발원조(ODA) 의료기기 관리 사례연구: 탄자니아 의용공학 교육 프로그램 컨설팅 (A Case Study of the Official Development Assistance Medical Device Management: Consultation for a Medical Engineering Education Program in Tanzania)

  • 윤문수;채명신;이명근;홍승연
    • 보건의료산업학회지
    • /
    • 제11권3호
    • /
    • pp.129-144
    • /
    • 2017
  • Objectives : To review a Tanzanian medical engineering education program and determine improvement measures for the Official Development Assistance (ODA) healthcare projects. Methods : A consultation of the Tanzanian medical engineering education program funded by the National Research Foundation of Korea (NRFK) was reviewed. An on site survey, an environmental analysis, and in-depth interviews were performed. Results : Survey results highlighted a lack of medical device education and the low operating rate of medical equipment. The need to establish educational program was thus confirmed. The expansion of healthcare facilities appeared to be limited within the current medical management system. A master coursework plan for Tanzania medical engineering was developed. Conclusions : The needs of medical engineering education were recognized. A plan and curriculum were developed. The medical engineering education program should be planned and budgeted prior to the ODA healthcare program.

Siderophore Production by Rhizosphere Biological Control Bacteria Brevibacillus brevis GZDF3 of Pinellia ternata and Its Antifungal Effects on Candida albicans

  • Sheng, Miaomiao;Jia, Huake;Zhang, Gongyou;Zeng, Lina;Zhang, Tingting;Long, Yaohang;Lan, Jing;Hu, Zuquan;Zeng, Zhu;Wang, Bing;Liu, Hongmei
    • Journal of Microbiology and Biotechnology
    • /
    • 제30권5호
    • /
    • pp.689-699
    • /
    • 2020
  • Brevibacillus brevis GZDF3 is a gram-positive, plant growth-promoting rhizosphere bacterium (PGPR) isolated from the rhizosphere soil of Pinellia ternata (an important herb in traditional Chinese medicine). The GZDF3 strain produces certain active compounds, such as siderophores, which are the final metabolite products of non-ribosomal peptide synthetase (NRPS) and independent non-ribosomal peptide synthetase (NIS) activity. With the present study, we attempted to investigate the siderophore production characteristics and conditions of Bacillus sp. GZDF3. The antibacterial activity of the siderophores on pathogenic fungi was also investigated. Optimal conditions for the synthesis of siderophores were determined by single factor method, using sucrose 15 g/l, asparagine 2 g/l, 32℃, and 48 h. The optimized sucrose asparagine medium significantly increased the production of siderophores, from 27.09% to 54.99%. Moreover, the effects of different kinds of metal ions on siderophore production were explored here. We found that Fe3+ and Cu2+ significantly inhibited the synthesis of siderophores. The preliminary separation and purification of siderophores by immobilized-metal affinity chromatography (IMAC) provides strong antibacterial activity against Candida albicans. The synergistic effect of siderophores and amphotericin B was also demonstrated. Our results have shown that the GZDF3 strain could produce a large amount of siderophores with strong antagonistic activity, which is helpful in the development of new biological control agents.