• Title/Summary/Keyword: Medical Direction

Search Result 1,194, Processing Time 0.026 seconds

Study on the development of convergence subjects for departments of emergency medical technology in preparation for the fourth industry revolution (4차 산업혁명 시대 응급구조(학)과 융복합 교과목 개발을 위한 연구)

  • Jung, Sang-Woo;Koh, Bong-Yeun;Lee, Jung-Eun;Hong, Sung-Gi;Kim, Soo-Tae
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.2
    • /
    • pp.71-97
    • /
    • 2021
  • Purpose: This study aimed to examine the development and improvement direction of university education according to job type and investigate the types of knowledge required for employment after graduation for departments of emergency medical technology in preparation for the era of the fourth industrial revolution in a converged society. Methods: From June 3 to June 10, 2019, data were collected through structured questionnaires from 90 paramedics working in firefighting, hospitals, different industries, and emergency patient transportation. Data were analyzed using the software SPSS version 18.0. Results: For employment after graduation in departments of emergency medical technology, character and sincerity education should be strengthened. To prepare for the fourth industrial revolution, educational innovations such as improving the field practice system and devising a convergence curriculum are needed. Preparation for the fourth industrial revolution should be accomplished through the development of convergence subjects such as forensic science, information and communications technology, and safety engineering. Ninety percent of the study respondents indicated their need for convergence subjects. Conclusion: The demands of future society should be responded to flexibly by holding and conducting convergence subjects. Furthermore, preparations should be made in anticipation of a shortage of 120,000 college freshmen for the 2024-2025 school year by increasing the competitiveness of departments of emergency medical technology.

Network pharmacology prediction to discover the potential pharmacological action mechanism of Rhizoma Dioscoreae for liver regeneration

  • Wei Liu;Wenyu Wang;Chenglong Tian;Ming-Zhong Sun;Shuqing Liu;Qinlong Liu
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.28 no.5
    • /
    • pp.479-491
    • /
    • 2024
  • Improving liver regeneration (LR) remains a medical issue, and there is currently a lack of safe and effective drugs for LR. Rhizoma Dioscoreae (SanYak, SY) is a traditional Chinese medicine. However, the underlying action mechanism of SY treatment for LR is yet to be fully elucidated. To explore the mechanism by which SY affects LR, we have conducted a series of methods for network pharmacological analysis, molecular docking, and in vivo experimental validation in mice. Overall, 9 compounds and 30 predicted target genes of SY were found to be associated with the therapeutic effects of LR. Compared with the model group, hematoxylin and eosin staining revealed that the mice with preoperative drug intervention possessed fewer postoperative hepatocyte bubbles and relatively regular morphology. Furthermore, the serum alanine transaminase and aspartate aminotransferase levels were reduced, immunohistochemistry revealed elevated proliferating cell nuclear antigen positivity rate, and Western blotting demonstrated that the phospho-protein kinase B (AKT)/AKT ratio was downregulated and that vascular endothelial growth factor A (VEGFA) expression levels were upregulated. This study explored dioscin, the main active ingredient of SY, and its potential therapeutic effects on LR. It repairs damaged liver following surgery and promotes liver cell proliferation. The action mechanism comprises reducing AKT phosphorylation levels and upregulating VEGFA expression levels. Thus, this study provides a new direction for further research on the mechanism of SY promoting LR.

The Influence of the Number of Electrodes, the Position and Direction of a Single Dipole on the Relation Between S/N ratio and EEG Dipole Source Estimation Errors (뇌전위의 단일 쌍극자 모델에서 전극의 개수, 쌍극자의 위치 및 방향이 S/N과 쌍극자 추정 오차사이의 관계에 미치는 영향에 관한 시뮬레이션 연구)

  • 김동우;배병훈
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.71-76
    • /
    • 1994
  • In the source localization using single dipole model, the influence of the number of electrodes, the position and direction of a single dipole on the relation between S/W ratio and dipole parameter estimation errors is important. Monte Carlo simulation was used to investigate this influence. The forward problem was calculated using three spherical shell model, and dipole parameters were optimized by means of simplex method. As the number of electrodes became large, as the dipole went from midbrain to cortex, and as the direction of dipole changed from radial to tangential, the average and standard deviation of estimation errors became small.

  • PDF

Joint mobilization techniques of the shoulder joint dysfunction (견관절 장애와 관절 가동운동)

  • Kim, Suhn-Yeop;Doo, Jung-Hee
    • Physical Therapy Korea
    • /
    • v.2 no.2
    • /
    • pp.108-118
    • /
    • 1995
  • The techniques of joint mobilization and traction are used to improve joint mobility or to decrease pain by restoring accessory movements to the shoulder joints and thus allowing full, nonrestriced, pain-free range of motion. In the glenohumeral joint, the humeral head would be the convex surface, while the glenoid fossa would be the concave surface. The medial end of the clavicle is concave anterioposteriorly and convex superioinferiorly, the articular surface of the sternum is reciprocally curved. The acromioclavicular joint is a plane synovial joint between a small convex facet on lateral end of the clavicle and a small concave facet on the acromion of the scapula. The relationship between the shape of articulating joint surface and the direction of gliding is defined by the Convex-Concave Rule. If the concave joint surface is moving on a stationary convex surface, gliding occur in the same direction as the rolling motion. If the convex surface is moving on a stationary concave surface, gliding will occur in an opposite direction to rolling. Hypomobile shoulder joints are treated be using a gliding technique.

  • PDF

Anatomy of the diaphyseal nutrient foramen in the long bones of the pectoral limb of German Shepherds

  • Sim, Jeoung-Ha;Ahn, Dongchoon
    • Korean Journal of Veterinary Research
    • /
    • v.54 no.3
    • /
    • pp.179-184
    • /
    • 2014
  • This study investigated the anatomy of the nutrient foramen (NF) in German Shepherds by recording the number, site, position, and direction of penetration of the nutrient canal (NC) in the humerus, radius, and ulna of 50 individuals. The site index of the nutrient foramen (SI) was calculated as the ratio of the length to the NF site from the proximal end to the greatest length of the bone. The NF diameter was measured using different sized needles. Most humeri had only one NF on the caudal surface, particularly on the lateral supracondylar crest, or distal cranial surface. All radii had one NF, usually on the caudal surface, while most ulnae had one NF located on either the cranial or lateral surfaces. The SI and NF diameters were 58.0~59.5% and 0.73~0.78 mm in the humerus, 30.4~30.9% and 0.74~0.76 mm in the radius, and 29.3~29.8% and 0.67~0.68 mm in the ulna, respectively. With the exception of the relatively proximal NF of the radius, the direction of penetration followed Berard's rule. This study provides novel information on the location and diameter of the NF and direction of the NC in the long bones of the pectoral limb of German Shepherds.

Activities of Upper Limb Muscles Related to the Direction of Elastic Tape Application in Healthy Adults: A Randomized Trial of Parallel-Aligned Versus Cross-Aligned Tape Application

  • Oh, Duck-Won;Chon, Seung-Chul
    • Physical Therapy Korea
    • /
    • v.20 no.4
    • /
    • pp.9-15
    • /
    • 2013
  • The purpose of this study was to evaluate the differences in electromyographic (EMG) activities of upper limb muscles between cross- and parallel-aligned taping and to compare the effects of these 2 taping methods in healthy adults. Thirty subjects, who volunteered for this study, were tested under 3 taping conditions in random order: (1) no taping, (2) cross-aligned taping, and (3) parallel-aligned taping. EMG activities of the biceps brachii, triceps brachii, flexor carpi ulnaris, and extensor carpi radialis muscles were measured. All muscles showed significant differences in EMG activity among the 3 conditions (p<.05). In the post hoc test, biceps brachii and triceps brachii muscles showed significant differences in EMG activity between the no taping and the cross-aligned taping conditions and between the no taping and the parallel-aligned taping conditions. Additionally, the EMG activities of the flexor carpi radialis and extensor carpi radialis muscles appeared to be significantly different between the no taping and parallel-aligned taping conditions. These findings demonstrate that taping may be helpful for decreasing muscle activity, regardless of the direction of tape application. This study provides useful information to future researchers regarding the effects of taping on muscle activity.

Analysis on the Effect of Field Width in the Delineation of Planning Target Volume for TomoTherapy (토모테라피에서 계획용표적체적 설정 시 필드 폭 영향 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mee-Sun;Jung, Jae-Uk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.323-331
    • /
    • 2010
  • The Hi-Art system for TomoTherapy allows only three (1.0 cm, 2.5 cm, 5.0 cm) field widths and this can produce different dose distribution around the end of PTV (Planning target volume) in the direction of jaw movement. In this study, we investigated the effect of field width on the dose difference around the PTV using DQA (Delivery quality assurance) phantom and real clinical patient cases. In the analysis with DQA phantom, the calculated dose and irradiated films showed that the more dose was widely spreaded out in the end region of PTV as increase of field width. The 2.5 cm field width showed a 1.6 cm wider dose profile and the 5.0 cm field width showed a 4.2 cm wider dose profile compared with the 1.0 cm field width in the region of 50% of maximum dose. The analysis with four patient cases also showed the similar results with the DQA phantom which means that more dose was irradiated around the superior and inferior end of PTV as an increase of field width. The 5.0 cm field width produced the remarkable high dose distribution around the end region of PTV and we could evaluate the effect quantitatively with the calculation of DVH (Dose volume histogram) of the virtual PTVs which were delineated around the end of PTV in the direction of jaw variation. From these results, we could verify that the margin for PTV in the direction of table movement should be reduced compared with the conventional margin for PTV when the large field such as 5.0 cm was used in TomoTherapy.

The Study of Appropriate X-ray Tube Angle for the Anterior-posterior Chest Radiography Using S-align Function (S-align 기능을 이용한 흉부 전·후 방향 검사 시 적절한 X선관 각도에 관한 연구)

  • Park, Myeong-Ju;Joo, Young-Cheol;Kim, Min-Suk;Yuk, Jeong-Won;Kim, Han-Yong;Kim, Dong-Hwan
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.299-304
    • /
    • 2022
  • This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 kVp, 160 mA, 50 ms, and the distance between the central X-ray and the image receptor was set to 180 cm and 110 cm, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5~25°, TCE 5~15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 mm, 54.13±0.37 mm, 16.16±0.46 mm, 9.81±0.35 mm, 2.75±0.30 mm, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 mm. T 0°, TCA 5~25°, TCE 5~15° were 15.72±0.38 mm, 24.10±0.50 mm, 29.24±0.86 mm, 34.35±0.35 mm, 41.06±1.08 mm, 48.07±0.38 mm, 12.85±0.25 mm, 7.92±0.36 mm, 3.01±0.39 mm, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using 'S-align' function is considered necessary.

Study on Quality Improvement Activities in Korean Hospitals (국내 의료기관의 질 향상 사업주제)

  • Chae, Yoo Mi;Lee, Sun Hee;Choi, Kui-Son
    • Quality Improvement in Health Care
    • /
    • v.8 no.2
    • /
    • pp.232-243
    • /
    • 2001
  • Background : the hospitals in Korea are in a situation of a severe competition than the past. This situation was resulted from the increase in the number of hospitals and also from the government policy controlling the medical insurance fee. Moreover, consumer's desire for the high quality medical service g\has been significantly increased. Many programs to improve the quality of medical services are being performed in hospitals since the middle of 1990's. Studies up to now reported that more than 10 programs are being performed per hospital in Korea. So far studies have been performed to measure only the number of such programs in a hospital. The purposes of this study are to examine a specific area involved in the programs designed to improve the medical service quality and to suggest a future direction of the such programs. In addition, we hope that the results from this study could assist the programs for the medical service quality. Methods : A mailed questionnaire survey of the QI staffs at hospitals with 400 beds or more was conducted between September 15 and October 30, 2000. Of the 108 hospitals eligible for inclusion in our study, 69 participated, yielding a response rate of 63.9%. Excluding 7 hospital which are not responsed about activities of hospital then 62 hospitals were used for the analysis. Result : The total number of programs was 1,081 from the 62 hospitals participated in the survey. The highest number (24.8 programs) was found in the hospital having more than 800 beds and performing the programs more than 5 years. The 1,081 programs were consisted of 445 from the medical examination area, 343 from the medical examination support area, and 296 from the management area. Conclusion : This study showed the present situation of hospitals in Korea regarding to the quality improvement programs. The results from this study suggest that the pattern of the program for the medical service improvement is being changed to service process and result-centered programs from the structural area.

  • PDF

Image-Guided Radiotherapy for Target Localization in Prostate Cancer with Implanted Markers

  • Suh, Ye-Lin;Park, Sung-Ho;Ahn, Seung-Do;Kim, Jong-Hoon;Lee, Sang-Wook;Shin, Seong-Soo;Choi, Eun-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.68-70
    • /
    • 2005
  • To precisely localize target in prostate cancer, image-guided radiotherapy was performed using the $ExacTrac^{\circledR}$ x-ray system (Brainlab, Germany) with implanted markers. For three prostate cancer patients, three gold markers were implanted into prostate. Orthogonal portal images were acquired every treatment and CT scans were repeated 3~5 times during the course of treatment. After correcting setup errors calculated by the system, the position of the implanted markers and the distance between them were detected in daily portal images and in CT images, and analyzed retrospectively. Deviation of the relative position of the implanted markers and the distance between them were less than 1 mm in lateral, longitudinal, and vertical direction for three patients, both in portal images and CT images. This study reveals that image-guided radiotherapy using the $ExacTrac^{\circledR}$ system is useful to verify positioning errors and localize prostate target with implanted markers, reducing the planning target volume (PTV) margin as well as irradiation to rectum and bladder.

  • PDF